Search NASA⌕ Search

SEARCH · Search NASA

Results for “Standard deviation modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Spinning no-scale $${\mathcal {F}}$$-SU(5) in the right direction

Abstract The Fermi National Accelerator Laboratory (FNAL) recently announced confirmation of the Brookhaven National Lab (BNL) measurements of the $$g-2$$ g - 2 of the muon that uncovered a discrepancy with the theoretically calculated Standard Model value. We suggest an explanation for the combined BNL+FNAL 4.2 $$\sigma $$ σ deviation within the supersymmetric grand unification theory (GUT) model No-Scale $${\mathcal {F}}$$ F - $$SU(5)$$ S U ( 5 ) supplemented with a string derived TeV-scale extra $$10+\overline{10}$$ 10 + 10 ¯ vector-like multiplet and charged vector-like singlet $$(XE,XE^c)$$ ( X E , X E c ) , dubbed flippons. We introduced these vector-like particles into No-Scale Flipped SU (5) many years ago, and as a result, the renormalization group equation (RGE) running was immediately shaped to produce a distinctive and rather beneficial two-stage gauge coupling unification process to avoid the Landau pole and lift unification to the string scale, in addition to contributing through 1-loop to the light Higgs boson mass. The flippons have long stood ready to tackle another challenge, and now do so yet again, where the charged vector-like “lepton”/singlet couples with the muon, the supersymmetric down-type Higgs $$H_d$$ H d , and a singlet S , using a chirality flip to easily accommodate the muonic $$g-2$$ g - 2 discrepancy in No-Scale $${\mathcal {F}}$$ F - $$SU(5)$$ S U ( 5 ) . Considering the phenomenological success of this string derived model over the prior 11 years that remains accommodative of all presently available LHC limits plus all other experimental constraints, including no fine-tuning, and the fact that for the first time a Starobinsky-like inflationary model consistent with all cosmological data was derived from superstring theory in No-Scale Flipped SU (5), we believe it is imperative to reconcile the BNL+FNAL developments within the model space.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Constraints on Lorentz Invariance Violation from Optical Polarimetry of Astrophysical Objects

Theories of quantum gravity suggest that Lorentz invariance, the fundamental symmetry of the Theory of Relativity, may be broken at the Planck energy scale. While any deviation from conventional Physics must be minuscule in particular at attainable energies, this hypothesis motivates ever more sensitive tests of Lorentz symmetry. In the photon sector, astrophysical observations, in particular polarization measurements, are a very powerful tool because tiny deviations from Lorentz invariance will accumulate as photons propagate over cosmological distances. The Standard-Model Extension (SME) provides a theoretical framework in the form of an effective field theory that describes low-energy effects due to a more fundamental quantum gravity theory by adding additional terms to the Standard Model Lagrangian. These terms can be ordered by the mass dimension d of the corresponding operator and lead to a wavelength, polarization, and direction dependent phase velocity of light. Lorentz invariance violation leads to an energy-dependent change of the Stokes vector as photons propagate, which manifests itself as a rotation of the polarization angle in measurements of linear polarization. In this paper, we analyze optical polarization measurements from 63 Active Galactic Nuclei (AGN) and Gamma-ray Bursts (GRBs) to search for Lorentz violating signals. We use both spectropolarimetric measurements, which directly constrain the change of linear polarization angle, as well as broadband spectrally integrated measurements. In the latter, Lorentz invariance violation manifests itself by reducing the observed net polarization fraction. Any observation of non-vanishing linear polarization thus leads to constraints on the magnitude of Lorentz violating effects. We derive the first set limits on each of the 10 individual birefringent coefficients of the minimal SME with d = 4 , with 95% confidence limits on the order of 10−34 on the dimensionless coefficients.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Planck intermediate results: XLIV. Structure of the Galactic magnetic field from dust polarization maps of the southern Galactic cap

Using data from the Planck satellite, we study in this paper the statistical properties of interstellar dust polarization at high Galactic latitudes around the south pole (b < -60°). Our aim is to advance the understanding of the magnetized interstellar medium (ISM), and to provide a modelling framework of the polarized dust foreground for use in cosmic microwave background (CMB) component-separation procedures. We examine the Stokes I, Q, and U maps at 353 GHz, and particularly the statistical distribution of the polarization fraction (p) and angle (ψ), in order to characterize the ordered and turbulent components of the Galactic magnetic field (GMF) in the solar neighbourhood. The Q and U maps show patterns at large angular scales, which we relate to the mean orientation of the GMF towards Galactic coordinates (l 0 ,b 0 ) = (70° ± 5°,24° ± 5°). The histogram of the observed p values shows a wide dispersion up to 25%. The histogram of ψ has a standard deviation of 12° about the regular pattern expected from the ordered GMF. We build a phenomenological model that connects the distributions of p and ψ to a statistical description of the turbulent component of the GMF, assuming a uniform effective polarization fraction (p 0 ) of dust emission. To compute the Stokes parameters, we approximate the integration along the line of sight (LOS) as a sum over a set of N independent polarization layers, in each of which the turbulent component of the GMF is obtained from Gaussian realizations of a power-law power spectrum. We are able to reproduce the observed p and ψ distributions using a p 0 value of 26%, a ratio of 0.9 between the strengths of the turbulent and mean components of the GMF, and a small value of N. The mean value of p (inferred from the fit of the large-scale patterns in the Stokes maps) is 12 ± 1%. We relate the polarization layers to the density structure and to the correlation length of the GMF along the LOS. We emphasize the simplicity of our model (involving only a few parameters), which can be easily computed on the celestial sphere to produce simulated maps of dust polarization. Finally, our work is an important step towards a model that can be used to assess the accuracy of component-separation methods in present and future CMB experiments designed to search the B mode CMB polarization from primordial gravity waves.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of transport mechanism on the coarsening of bicontinuous structures: A comparison between bulk and surface diffusion

Here, coarsening of bicontinuous microstructures is observed in a variety of systems, such as nanoporous metals and mixtures that have undergone spinodal decomposition. To better understand the morphological evolution of these structures during coarsening, we compare the morphologies resulting from two different coarsening mechanisms, surface and bulk diffusion. We perform phase-field simulations of coarsening via each mechanism in a two-phase mixture at nominal volume fractions of 50%-50% and 36%-64%, and the simulated structures are characterized in terms of topology (genus density), the interfacial shape distribution, structure factor, and autocorrelations of phase and mean curvature. We observe self-similar evolution of morphology and topology and agreement with the expected power laws for dynamic scaling, in which the characteristic length scale increases over time proportionally to t 1/4 for surface diffusion and t 1/3 for bulk diffusion. While we observe the expected difference in the coarsening kinetics, we find that differences in self-similar morphology due to coarsening mechanism are relatively small, although typically they are larger at 36% volume fraction than at 50% volume fraction. In particular, we find that bicontinuous structures coarsened via surface diffusion have lower scaled genus densities than structures coarsened via bulk diffusion. We also compare the self-similar morphologies to those in literature and to two model bicontinuous structures, namely, constant-mean-curvature surfaces based on the Schoen G minimal surface and random leveled-wave structures. The average scaled mean curvatures of these model structures agree reasonably with those of the coarsened structures at both 36% and 50%, but we find substantial disagreements in the scaled genus densities and the standard deviations of mean curvature.

36 MATERIALS SCIENCE↗

Vacuum stability bounds on Higgs coupling deviations in the absence of new bosons

We analyze the constraints imposed by Higgs vacuum stability on models with new fermions beyond the Standard Model. We focus on the phenomenology of Higgs couplings accessible at the Large Hadron Collider. New fermions that affect Higgs couplings lead to vacuum instability of the Higgs potential. Above the scale of vacuum instability, bosonic states must stabilize the potential, implying a cut-off to the pure fermion model. Conservatively tuning the models to produce the maximal cut-off for a given Higgs coupling effect, we show that observing a deviation in the Htt, H-diphoton, or H-digluon coupling, larger than 20%, would require that new bosons exist in order to stabilize the Higgs potential below about 100 TeV. For generic parameter configurations, and unless the new fermions are made as light as they can possibly be given current experimental constraints, observing a 10% deviation in any of these couplings would suggest an instability cut-off below 10-100 TeV. Similarly, if new bosons are absent up to a high scale, then a deviation in the Hbb or Hττ coupling, larger than about 20%, should be accompanied by a sizable deviation in the Zbb or Zττ couplings that can be conclusively tested with electroweak precision measurements at planned lepton colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Model independent tests of the standard cosmological model

The dark energy problem has led to speculation that not only may {Lambda}CDM be wrong, but that the Friedmann-Lemaitre-Robertson-Walker models themselves may not even provide the correct family of background models. We discuss how direct measurements of H(z) can be used to formulate tests of the standard paradigm in cosmology. On their own, such measurements can be used to test for deviations from flat {Lambda}CDM. When combined with supernovae distances, Hubble rate measurements provide a test of the Copernican principle and the homogeneity assumption of the standard model, which is independent of dark energy or a metric based the theory of gravity. A modification of this test also provides a model independent observable for flatness which decorrelates curvature determination from dark energy. We investigate these tests using Hubble rate measurements from age data, as well as from a Hubble rate inferred from recent measurements of the baryon acoustic oscillations. While the current data are too weak to say anything significant, these tests are exciting prospects for the future.

79 ASTRONOMY AND ASTROPHYSICS↗

CT, MR, and ultrasound image artifacts from prostate brachytherapy seed implants: The impact of seed size

Purpose: To investigate the effects of brachytherapy seed size on the quality of x-ray computed tomography (CT), ultrasound (US), and magnetic resonance (MR) images and seed localization through comparison of the 6711 and 9011 {sup 125}I sources. Methods: For CT images, an acrylic phantom mimicking a clinical implantation plan and embedded with low contrast regions of interest (ROIs) was designed for both the 0.774 mm diameter 6711 (standard) and the 0.508 mm diameter 9011 (thin) seed models (Oncura, Inc., and GE Healthcare, Arlington Heights, IL). Image quality metrics were assessed using the standard deviation of ROIs between the seeds and the contrast to noise ratio (CNR) within the low contrast ROIs. For US images, water phantoms with both single and multiseed arrangements were constructed for both seed sizes. For MR images, both seeds were implanted into a porcine gel and imaged with pelvic imaging protocols. The standard deviation of ROIs and CNR values were used as metrics of artifact quantification. Seed localization within the CT images was assessed using the automated seed finder in a commercial brachytherapy treatment planning system. The number of erroneous seed placements and the average and maximum error in seed placements were recorded as metrics of the localization accuracy. Results: With the thin seeds, CT image noise was reduced from 48.5 {+-} 0.2 to 32.0 {+-} 0.2 HU and CNR improved by a median value of 74% when compared with the standard seeds. Ultrasound image noise was measured at 50.3 {+-} 17.1 dB for the thin seed images and 50.0 {+-} 19.8 dB for the standard seed images, and artifacts directly behind the seeds were smaller and less prominent with the thin seed model. For MR images, CNR of the standard seeds reduced on average 17% when using the thin seeds for all different imaging sequences and seed orientations, but these differences are not appreciable. Automated seed localization required an average ({+-}SD) of 7.0 {+-} 3.5 manual corrections in seed positions for the thin seed scans and 3.0 {+-} 1.2 manual corrections in seed positions for the standard seed scans. The average error in seed placement was 1.2 mm for both seed types and the maximum error in seed placement was 2.1 mm for the thin seed scans and 1.8 mm for the standard seed scans. Conclusions: The 9011 thin seeds yielded significantly improved image quality for CT and US images but no significant differences in MR image quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Belle II Detector: status and proposed US contributions

Conference proceedings for the 2012 American Physical Society, Division of Particles and Fields (DPF2012) conference. Paper is on the US contibutions to the Belle II detector upgrade. High precision flavor physics measurements are an essential complement to the direct searches for new physics at the LHC. Such measurements will be performed using the upgraded Belle II detector and upgraded KEKB accelerator. The status of the Belle II detector and proposed role of the US Belle II collaborators are presented in this article. The B factory experiments, Belle at the KEKB collider at KEK and BaBar at the PEP II collider at SLAC, were built to measure the large mixing-induced CP violation in the B0 system predicted by the theory of Kobayashi and Maskawa. The successful confirmation of the prediction led to the Nobel Prize for both theorists. The B factories were built to answer the question Is the CKM description in the Standard Model correct? Most B factory results are in good agreement with the expectations from the Standard Model (SM) and confirm the CKM structure of quark mixing and CP violation, but some measurements show tensions with the SM prediction. The Super B factories will address the question In what way is the Standard Model wrong? Much larger datasets are needed for high-precision measurements to search for significant deviations from the SM which are expected to exist. The SuperKEKB and Belle II detector are being constructed to perform these high precision studies with a dataset 50ab{sup -1}. The SuperKEKB accelerator will operate at an instantaneous luminosity of 8 x 10{sup 35}cm{sup -2}s{sup -1}, a factor of 40 times higher than the luminosity of the KEKB accelerator at the end of the Belle physics program. The increased luminosity will derive primarily from shrinking the beam size at the interaction point (nano beams) utilizing new final focus quadrapole magnets in combination with a factor of 2 increase in beam currents. To counteract the increase in the beam-beam parameter due to the reduced beta functions, the beam emittance must also be reduced; this will be achieved with a new electron source and a new damping ring.

43 PARTICLE ACCELERATORS↗

Time-integrated activity coefficient estimation for radionuclide therapy using PET and a pharmacokinetic model: A simulation study on the effect of sampling schedule and noise

Purpose: The aim of this study was to investigate the accuracy of PET-based treatment planning for predicting the time-integrated activity coefficients (TIACs). Methods: The parameters of a physiologically based pharmacokinetic (PBPK) model were fitted to the biokinetic data of 15 patients to derive assumed true parameters and were used to construct true mathematical patient phantoms (MPPs). Biokinetics of 150 MBq {sup 68}Ga-DOTATATE-PET was simulated with different noise levels [fractional standard deviation (FSD) 10%, 1%, 0.1%, and 0.01%], and seven combinations of measurements at 30 min, 1 h, and 4 h p.i. PBPK model parameters were fitted to the simulated noisy PET data using population-based Bayesian parameters to construct predicted MPPs. Therapy simulations were performed as 30 min infusion of {sup 90}Y-DOTATATE of 3.3 GBq in both true and predicted MPPs. Prediction accuracy was then calculated as relative variability v{sub organ} between TIACs from both MPPs. Results: Large variability values of one time-point protocols [e.g., FSD = 1%, 240 min p.i., v{sub kidneys} = (9 ± 6)%, and v{sub tumor} = (27 ± 26)%] show inaccurate prediction. Accurate TIAC prediction of the kidneys was obtained for the case of two measurements (1 and 4 h p.i.), e.g., FSD = 1%, v{sub kidneys} = (7 ± 3)%, and v{sub tumor} = (22 ± 10)%, or three measurements, e.g., FSD = 1%, v{sub kidneys} = (7 ± 3)%, and v{sub tumor} = (22 ± 9)%. Conclusions: {sup 68}Ga-DOTATATE-PET measurements could possibly be used to predict the TIACs of {sup 90}Y-DOTATATE when using a PBPK model and population-based Bayesian parameters. The two time-point measurement at 1 and 4 h p.i. with a noise up to FSD = 1% allows an accurate prediction of the TIACs in kidneys.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Is the assumption of normality or log-normality for continuous response data critical for benchmark dose estimation?

Continuous responses (e.g. body weight) are widely used in risk assessment for determining the benchmark dose (BMD) which is used to derive a U.S. EPA reference dose. One critical question that is not often addressed in dose–response assessments is whether to model the continuous data as normally or log-normally distributed. Additionally, if lognormality is assumed, and only summarized response data (i.e., mean ± standard deviation) are available as is usual in the peer-reviewed literature, the BMD can only be approximated. In this study, using the “hybrid” method and relative deviation approach, we first evaluate six representative continuous dose–response datasets reporting individual animal responses to investigate the impact on BMD/BMDL estimates of (1) the distribution assumption and (2) the use of summarized versus individual animal data when a log-normal distribution is assumed. We also conduct simulation studies evaluating model fits to various known distributions to investigate whether the distribution assumption has influence on BMD/BMDL estimates. Our results indicate that BMDs estimated using the hybrid method are more sensitive to the distribution assumption than counterpart BMDs estimated using the relative deviation approach. The choice of distribution assumption has limited impact on the BMD/BMDL estimates when the within dose-group variance is small, while the lognormality assumption is a better choice for relative deviation method when data are more skewed because of its appropriateness in describing the relationship between mean and standard deviation. Additionally, the results suggest that the use of summarized data versus individual response data to characterize log-normal distributions has minimal impact on BMD estimates. - Highlights: • We investigate to what extent the distribution assumption can affect BMD estimates. • Both real data analysis and simulation study are conducted. • BMDs estimated using hybrid method are more sensitive to distribution assumption. • Summarized continuous data are adequate for BMD estimation.

60 APPLIED LIFE SCIENCES↗

Cosmological parameter estimation: impact of CMB aberration

The peculiar motion of an observer with respect to the CMB rest frame induces an apparent deflection of the observed CMB photons, i.e. aberration, and a shift in their frequency, i.e. Doppler effect. Both effects distort the temperature multipoles a{sub lm}'s via a mixing matrix at any l. The common lore when performing a CMB based cosmological parameter estimation is to consider that Doppler affects only the l = 1 multipole, and neglect any other corrections. In this paper we reconsider the validity of this assumption, showing that it is actually not robust when sky cuts are included to model CMB foreground contaminations. Assuming a simple fiducial cosmological model with five parameters, we simulated CMB temperature maps of the sky in a WMAP-like and in a Planck-like experiment and added aberration and Doppler effects to the maps. We then analyzed with a MCMC in a Bayesian framework the maps with and without aberration and Doppler effects in order to assess the ability of reconstructing the parameters of the fiducial model. We find that, depending on the specific realization of the simulated data, the parameters can be biased up to one standard deviation for WMAP and almost two standard deviations for Planck. Therefore we conclude that in general it is not a solid assumption to neglect aberration in a CMB based cosmological parameter estimation.

79 ASTRONOMY AND ASTROPHYSICS↗

Active learning enables generation of molecules that advance the known Pareto front

Although generative models hold promise for discovering molecules with optimized desired properties, they often fail to suggest synthesizable molecules that improve upon the properties of the structures represented in the training distribution. We find that this limitation arises not only from the molecule generation process itself, but also from the poor generalization capabilities of molecular property predictors. We address this challenge by creating a closed-loop molecule generation pipeline with iterative retraining on new quantum chemical simulation data. Compared against static, single-pass generative modeling approaches, only our closed-loop iterative workflow generates molecules with properties extending beyond the training distribution (up to 0.44 standard deviations beyond the original range) and achieves a 79% improvement in out-of-distribution molecule classification accuracy. Furthermore, by conditioning molecular generation on thermodynamic stability data obtained during the iterative loop, the proportion of stable and hence potentially synthesizable molecules generated is 3.5x higher than the next-best model.

Chemistry↗

Dependency of EBT2 film calibration curve on postirradiation time

Purpose: The Ashland Inc. product EBT2 film model is a widely used quality assurance tool, especially for verification of 2-dimensional dose distributions. In general, the calibration film and the dose measurement film are irradiated, scanned, and calibrated at the same postirradiation time (PIT), 1-2 days after the films are irradiated. However, for a busy clinic or in some special situations, the PIT for the dose measurement film may be different from that of the calibration film. In this case, the measured dose will be incorrect. This paper proposed a film calibration method that includes the effect of PIT. Methods: The dose versus film optical density was fitted to a power function with three parameters. One of these parameters was PIT dependent, while the other two were found to be almost constant with a standard deviation of the mean less than 4%. The PIT-dependent parameter was fitted to another power function of PIT. The EBT2 film model was calibrated using the PDD method with 14 different PITs ranging from 1 h to 2 months. Ten of the fourteen PITs were used for finding the fitting parameters, and the other four were used for testing the model. Results: The verification test shows that the differences between the delivered doses and the film doses calculated with this modeling were mainly within 2% for delivered doses above 60 cGy, and the total uncertainties were generally under 5%. The errors and total uncertainties of film dose calculation were independent of the PIT using the proposed calibration procedure. However, the fitting uncertainty increased with decreasing dose or PIT, but stayed below 1.3% for this study. Conclusions: The EBT2 film dose can be modeled as a function of PIT. For the ease of routine calibration, five PITs were suggested to be used. It is recommended that two PITs be located in the fast developing period (1∼6 h), one in 1 ∼ 2 days, one around a week, and one around a month.

61 RADIATION PROTECTION AND DOSIMETRY↗

Search for Higgs boson production in association with a high-energy photon via vector-boson fusion with decay into bottom quark pairs at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search is presented for the production of the Standard Model Higgs boson in association with a high-energy photon. With a focus on the vector-boson fusion process and the dominant Higgs boson decay into b-quark pairs, the search benefits from a large reduction of multijet background compared to more inclusive searches. Results are reported from the analysis of 132 fb –1 of pp collision data at $\sqrt{s}$ = 13 TeV collected with the ATLAS detector at the LHC. The measured Higgs boson signal yield in this final-state signature is 1.3 ± 1.0 times the Standard Model prediction. The observed significance of the Higgs boson signal above the background is 1.3 standard deviations, compared to an expected significance of 1.0 standard deviations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation of the IRI-2016 model with Indian NavIC data for future navigation applications

The position accuracy of Navigation with Indian Constellation (NavIC) system is affected by several sources of errors. Among them, the Ionospheric Time Delay (ITD) error is the most predominant one which depends upon the total electron content (TEC) present in the ionosphere. The ITD variations are more intense over low latitude regions due to the equatorial anomaly effects. Hence, modelling of ITD error is necessary. The International Reference Ionosphere (IRI)-2016 model is one of the standard global ionospheric models to estimate the Vertical TEC (VTEC). This paper discusses about the VTEC deviations due to the IRI-2016 model over low latitude Hyderabad station, Indian region using NavIC, Global Positioning System and Global Navigation Satellite System signals at corresponding Ionospheric Pierce Point latitude and longitudes for all months and various Kp indices during the low solar activity year 2017. In this work, cross correlation coefficient, the metric norm (L2N), Symmetric Kullbacke Leibler Distance metrics are used to evaluate the performance of IRI-2016 model TEC with NavIC, GPS and GLONASS data. From the results, it is found that TEC predicted by the IRI-2016 model produced smaller estimation errors with NavIC data over Indian region. The obtained results will be helpful for future updates of IRI model.

42 ENGINEERING↗

Pearson's Functions to Describe FSW Weld Geometry

Friction stir welding (FSW) is a relatively new joining technique particularly for aluminium alloys that are difficult to fusion weld. In this study, the geometry of the weld has been investigated and modelled using Pearson's functions. It has been demonstrated that the Pearson's parameters (mean, standard deviation, skewness, kurtosis and geometric constant) can be used to characterize the weld geometry and the tensile strength of the weld assembly. Pearson's parameters and process parameters are strongly correlated allowing to define a control process procedure for FSW assemblies which make radiographic or ultrasonic controls unnecessary. Finally, an optimisation using a Generalized Gradient Method allows to determine the geometry of the weld which maximises the assembly tensile strength.

36 MATERIALS SCIENCE↗

Uranium Concentration Measurement Technique Viability Analysis

This report incorporates experimental and modelling data in support of the uranium UV-vis concentration analysis technique as applied to uranium sulfate solutions, and a short literature survey on the ‘Industry Standard’ Davies-Gray titration method for uranium analysis. A preliminary screen of a suite of contaminants that could interfere with the UV-vis measurement has revealed ruthenium to be by far the most likely to negatively impact the analysis technique, and this element is worthy of a more detailed study. Other experimental work confirm technique reproducibility and solution uniformity over time, and the potential viability of adaption to online analysis, while the application of the Guide to Uncertainty Measurements (GUM) to the UV-vis technique has been explored for the first time. Preliminary modelling analysis using GUM Workbench indicate 0.5 % technique relative uncertainty at the equivalent of two standard deviations, with an associated uncertainty ‘budget’ which provides guidance as to where the technique can be further developed to lower uncertainties.

07 ISOTOPE AND RADIATION SOURCES↗