Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

In-tank, on-shot characterization of the OMEGA laser system focal spot

Direct-drive fusion implosion experiments using the 60-beam OMEGA Laser System require ~1% rms uniformity on target. Measurements from laser diagnostics indicate that beam-to-beam power variation has been sufficiently reduced such that the uniformity nearly meets this requirement; however, experimental results suggest otherwise. To better understand this discrepancy, a full-beam-in-tank diagnostic has been developed to characterize the on-shot, full-energy focal spot of a single beam inside the target chamber using a small sample of the beam from the final optic assembly. In this paper, we describe the diagnostic and present the results of commissioning experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The optimal optical readout for the x-ray light valve--Document scanners

The x-ray light valve (XLV) is a novel, potentially low-cost, x-ray detector that converts an x-ray exposure into an optical image stored in a liquid crystal cell. This optical image is then transferred from the liquid crystal cell to a computer through an optical-to-digital imaging readout system. Previously, CCD-based cameras were used for the optical readout, but recently it was proposed that an inexpensive optical scanner, such as an office document scanner, is a better match to the optical properties of the XLV. A methodology for characterizing a document scanner's ability to produce medical quality images from the XLV is outlined and tested on a particular scanner (Canon LiDE 30). This scanner was shown to have key characteristics of a medical device--a linear response, dynamic range sufficient for chest radiography (although not mammography) in a single pass, and an MTF and NPS that exceed the requirements for all medical applications of the scanner. This combination of criteria shows that a document scanner can be used as a digitization method for the XLV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Absolute Color Calibration of the Dark Energy Survey: A Spectrophotometric Sample of DA White Dwarfs in the Southern Sky

The Dark Energy Survey (DES), which is nearing the completion of the analysis of its full data set, is an imaging survey of one-quarter of the Southern sky down to an apparent magnitude of $i\sim24.5$. The survey observations were conducted between 2013 and 2019 with a 3-square-degree wide-field CCD mosaic camera (the Dark Energy Camera, or DECam) on the Blanco 4-meter telescope at the Cerro Tololo Interamerican Observatory in the Chilean Andes. The primary scientific goal of the DES was to measure properties of Dark Energy. In order to achieve its science goals, the DES had tight requirements on both its relative and absolute photometric calibrations. In this poster, we describe the sample of pure-hydrogen-atmosphere (“DA”) white dwarfs which were instrumental in working to establish the requirement on the absolute color calibration -- i.e., the calibration across the filter bands -- of the DES.

79 ASTRONOMY AND ASTROPHYSICS↗

H α IMAGING OF NEARBY SEYFERT HOST GALAXIES

We used narrowband (Δ λ = 70 Å) interference filters with the CCD imaging camera on the Nickel 1.0 m telescope at Lick Observatory to observe 31 nearby ( z < 0.03) Seyfert galaxies in the 12 μ m active galaxy sample. We obtained pure emission-line images of each galaxy, which reach down to a flux limit of 7.3 × 10{sup −15} erg cm{sup −2} s{sup −1} arcsec{sup −2}, and corrected these images for [N ii] emission and extinction. We separated the H α emission line of the “nucleus” (central 100–1000 pc) from that of the host galaxy. The extended H α emission is expected to be powered by newly formed hot stars, and indeed correlates well with other indicators of current star formation rates (SFRs) in these galaxies: extended 7.7 μ m polycyclic aromatic hydrocarbon, total far-infrared, and radio luminosity. Relative to what would be expected from recent star formation, there is a 0.8 dex excess of radio emission in our Seyfert galaxies. The H α luminosity we measured in the centers of our galaxies is dominated by the active galactic nucleus (AGN), and is linearly correlated with the hard X-ray luminosity. There is, however, an upward offset of 1 dex in this correlation for the Seyfert 1s, because their nuclear H α emission includes a strong additional contribution from the broad-line region. We found a correlation between SFR and AGN luminosity. In spite of selection effects, we concluded that the absence of bright Seyfert nuclei in galaxies with low SFRs is real, albeit only weakly significant. Finally, we used our measured spatial distributions of H α emission to determine what these Seyfert galaxies would look like when observed through fixed apertures (e.g., a spectroscopic fiber) at high redshifts. We found that although all of these Seyfert galaxies would be detectable emission-line galaxies at any redshift, most of them would appear to be dominated by (>67%) their H ii region emission. Only the most luminous AGNs (log( L {sub Hα}/erg s{sup −1}) > 41.5) would still be identified as such at z ∼ 0.3.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatial distribution read-out system for thermoluminescence sheets

A spatial distribution read-out system of thermoluminescence (TL) sheets is developed. This system consists of high gain image intensifier, a CCD-TV camera, a video image processor and a host computer. This system has been applied to artificial TL sheets (BaSO4:Eu doped) for detecting high energy electromagnetic shower and heavy nuclei tracks.

Yamamoto, I.↗

Monocular electro-optical stereo scanner

MEOSS is a single optics and single spectral band camera. Three CCD's working in pushbroom mode are mounted perpendicular to the flight direction on a common focal plate. Their oblique views of + and - 23 degrees forward and backward, as well as nadir oriented, lead to threefold stereoscopic images. This principle allows a nearly simultaneous generation of all three images of a stereo triplet. The time gap between the forward and aft looking images guarantees constant illumination conditions. The ground resolution of MEOSS will be 52 by 80 m ground pixel size, height resolution of 55 m and swath width of 255 km. The drifting ground coverage pattern of MEOSS is unique compared to polar orbiting satellites and will allow images of an area to be taken at different times of the day. A scene will consist of 3144 scan lines, with each having 3236 pixels. The data will be received by the Deep Space Network of JPL Goldstone and mailed to Goddard.

Vermillion, C.↗

Software manual for operating particle displacement tracking data acquisition and reduction system

The software manual is presented. The necessary steps required to record, analyze, and reduce Particle Image Velocimetry (PIV) data using the Particle Displacement Tracking (PDT) technique are described. The new PDT system is an all electronic technique employing a CCD video camera and a large memory buffer frame-grabber board to record low velocity (less than or equal to 20 cm/s) flows. Using a simple encoding scheme, a time sequence of single exposure images are time coded into a single image and then processed to track particle displacements and determine 2-D velocity vectors. All the PDT data acquisition, analysis, and data reduction software is written to run on an 80386 PC.

Wernet, Mark P.↗

A pointable, helicopter-based remote sensing data acquisition system for collecting bidirectional reflectance data

Discussed here is a new configuration of a helicopter-borne remote sensing system to support field measurements programs such as studies of forest decline damage associated with atmospheric deposition and the Forest Ecosystems Dynamics project. In this new configuration, the sensor payload is mounted externally on a hinged pallet located on the starboard side of the Bell Iroquois UH-1B (HUEY) helicopter. The sensor payload includes a set of bore-sighted instruments consisting of a Barnes Modular Multiband Radiometer (MMR), a Spectron Engineering (SE) 590 spectroradiometer, an Everest infrared temperature sensor, and a Sony CCD video camera with a 10x zoom lens. The system was tested and excellent data was acquired in 1990.

Williams, Darrel L.↗

Liquid jet breakup and atomization in rocket chambers under dense spray conditions

Two advanced diagnostic techniques were established and employed in this project. The first technique involves the use of a real-time x ray radiography system along with a high-speed CCD Xybion camera and an advanced digital image processor to investigate the breakup processes of the liquid core. The focus of this part of the project is to determine the inner structure of the liquid jet and via thin sheets of laser light, with the scatters light being photographed by a Xybion electronic camera synchronized to the laser pulse. This technique, which is capable of recording the breakup event occurring within 25 nano-seconds, enables us to freeze the motions of the jet and liquid droplets. The focus of this part of the project is to determine the outer structure of the liquid jet and to discover the configuration of the surface waves, the spray pattern, and the droplet size distribution in the non-dilute region. Results obtained by these two advanced diagnostic techniques will provide the much needed database for model development and accurate prediction of engine performance. The present work also represents a breakthrough in the area of advanced diagnostics of dense sprays.

Kuo, Kenneth K.↗

The 3-D image recognition based on fuzzy neural network technology

Three dimensional stereoscopic image recognition system based on fuzzy-neural network technology was developed. The system consists of three parts; preprocessing part, feature extraction part, and matching part. Two CCD color camera image are fed to the preprocessing part, where several operations including RGB-HSV transformation are done. A multi-layer perception is used for the line detection in the feature extraction part. Then fuzzy matching technique is introduced in the matching part. The system is realized on SUN spark station and special image input hardware system. An experimental result on bottle images is also presented.

Hirota, Kaoru↗

A conceptual design study for a two-dimensional, electronically scanned thinned array radiometer

A conceptual design for the Two-Dimensional, Electronically Steered Thinned Array Radiometer (ESTAR) is described. This instrument is a synthetic aperture microwave radiometer that operates in the L-band frequency range for the measurement of soil moisture and ocean salinity. Two auxiliary instruments, an 8-12 micron, scanning infrared radiometer and a 0.4-1.0 micron, charge coupled device (CCD) video camera, are included to provided data for sea surface temperature measurements and spatial registration of targets respectively. The science requirements were defined by Goddard Space Flight Center. Instrument and the spacecraft configurations are described for missions using the Pegasus and Taurus launch vehicles. The analyses and design trades described include: estimations of size, mass and power, instrument viewing coverage, mechanical design trades, structural and thermal analyses, data and communications performance assessments, and cost estimation.

Mutton, Philip↗

A fuzzy structural matching scheme for space robotics vision

In this paper, we propose a new fuzzy structural matching scheme for space stereo vision which is based on the fuzzy properties of regions of images and effectively reduces the computational burden in the following low level matching process. Three dimensional distance images of a space truss structural model are estimated using this scheme from stereo images sensed by Charge Coupled Device (CCD) TV cameras.

Naka, Masao↗

Active Flow Control: Instrumentation Automation and Experimental Technique

In investigating the potential of a new actuator for use in an active flow control system, several objectives had to be accomplished, the largest of which was the experimental setup. The work was conducted at the NASA Langley 20x28 Shear Flow Control Tunnel. The actuator named Thunder, is a high deflection piezo device recently developed at Langley Research Center. This research involved setting up the instrumentation, the lighting, the smoke, and the recording devices. The instrumentation was automated by means of a Power Macintosh running LabVIEW, a graphical instrumentation package developed by National Instruments. Routines were written to allow the tunnel conditions to be determined at a given instant at the push of a button. This included determination of tunnel pressures, speed, density, temperature, and viscosity. Other aspects of the experimental equipment included the set up of a CCD video camera with a video frame grabber, monitor, and VCR to capture the motion. A strobe light was used to highlight the smoke that was used to visualize the flow. Additional effort was put into creating a scale drawing of another tunnel on site and a limited literature search in the area of active flow control.

Gimbert, N. Wes↗

Analytical Tools for Cloudscope Ice Measurement

The cloudscope is a ground or aircraft instrument for viewing ice crystals impacted on a sapphire window. It is essentially a simple optical microscope with an attached compact CCD video camera whose output is recorded on a Hi-8 mm video cassette recorder equipped with digital time and date recording capability. In aircraft operation the window is at a stagnation point of the flow so adiabatic compression heats the window to sublimate the ice crystals so that later impacting crystals can be imaged as well. A film heater is used for ground based operation to provide sublimation, and it can also be used to provide extra heat for aircraft operation. The compact video camera can be focused manually by the operator, and a beam splitter - miniature bulb combination provide illumination for night operation. Several shutter speeds are available to accommodate daytime illumination conditions by direct sunlight. The video images can be directly used to qualitatively assess the crystal content of cirrus clouds and contrails. Quantitative size spectra are obtained with the tools described in this report. Selected portions of the video images are digitized using a PCI bus frame grabber to form a short movie segment or stack using NIH (National Institute of Health) Image software with custom macros developed at DRI. The stack can be Fourier transform filtered with custom, easy to design filters to reduce most objectionable video artifacts. Particle quantification of each slice of the stack is performed using digital image analysis. Data recorded for each particle include particle number and centroid, frame number in the stack, particle area, perimeter, equivalent ellipse maximum and minimum radii, ellipse angle, and pixel number. Each valid particle in the stack is stamped with a unique number. This output can be used to obtain a semiquantitative appreciation of the crystal content. The particle information becomes the raw input for a subsequent program (FORTRAN) that synthesizes each slice and separates the new from the sublimating particles. The new particle information is used to generate quantitative particle concentration, area, and mass size spectra along with total concentration, solar extinction coefficient, and ice water content. This program directly creates output in html format for viewing with a web browser.

Arnott, W. Patrick↗

On the Temporal Evolution of Red Sprites, Runaway Theory Versus Data

The results of numerical simulations of red sprite discharges, namely the temporal evolutions of optical emissions, are presented and compared with observations. The simulations are done using the recently recalculated runaway avalanche rates. The temporal evolution of these simulations is in good agreement with ground-based photometer and CCD TV camera observations of red sprites. Our model naturally explains the "hairline" of red sprites as a boundary between the region where the intensity of optical emissions associated with runaway breakdown has a maximum and the region where the intensity of optical emissions caused by conventional breakdown and ambient electron heating has a maximum. We also present for the first time simulations of red sprites with a daytime conductivity profile.

Yukhimuk, V.↗

Real-Time Visualization of Tissue Ischemia

A real-time display of tissue ischemia which comprises three CCD video cameras, each with a narrow bandwidth filter at the correct wavelength is discussed. The cameras simultaneously view an area of tissue suspected of having ischemic areas through beamsplitters. The output from each camera is adjusted to give the correct signal intensity for combining with, the others into an image for display. If necessary a digital signal processor (DSP) can implement algorithms for image enhancement prior to display. Current DSP engines are fast enough to give real-time display. Measurement at three, wavelengths, combined into a real-time Red-Green-Blue (RGB) video display with a digital signal processing (DSP) board to implement image algorithms, provides direct visualization of ischemic areas.

Bearman, Gregory H.↗

Videogrammetric Model Deformation Measurement System User's Manual

The purpose of this manual is to provide the user of the NASA VMD system, running the MDef software, Version 1.10, all information required to operate the system. The NASA Videogrammetric Model Deformation system consists of an automated videogrammetric technique used to measure the change in wing twist and bending under aerodynamic load in a wind tunnel. The basic instrumentation consists of a single CCD video camera and a frame grabber interfaced to a computer. The technique is based upon a single view photogrammetric determination of two-dimensional coordinates of wing targets with fixed (and known) third dimensional coordinate, namely the span-wise location. The major consideration in the development of the measurement system was that productivity must not be appreciably reduced.

Dismond, Harriett R.↗

Search for Near-Earth Objects with Small Aphelion Distances

An essential component of our ability to efficiently find NEOs at small solar elongation is a focal reducer, whose construction is being separately funded by a grant from NSF. This focal reducer will increase the field of view of the 8k CCD mosaic camera from 19 arc min to about 32 arc min at the Cassegrain focus of the University of Hawaii 2.24-m telescope. As of January, all but one of the lenses for the focal reducer were in hand. The final lens had been delayed due to problems with the availability of the rather exotic material out of which the manufacturer was to fabricate the lens. Perhaps as a result of their rush to deliver that final lens, it developed a crack during the annealing process at the manufacturer, thus they had to start over. The total delay in delivery of that last lens was nearly ten months, and therefore the focal reducer was not completed on schedule and could not be used on the telescope this semester. A postdoctoral research associate was recruited to handle the day-to-day operations. The closing date for applications was 2002 December 3 1, and seven were received. One applicant was not qualified, and two were marginal. Of the four qualified candidates, Fabrizio Bernardi stood out as being best qualified. He was a student of Andrea Carusi and had worked on the CINEOS project in Italy, which includes a component of searching for NEOs at small solar elongations.

Tholen, David J.↗