Search NASA⌕ Search

SEARCH · Search NASA

Results for “CMOS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Harnessing Artificial Intelligence for Medical Diagnosis and Treatment During Space Exploration Missions

From May 8th to June 9th, 2023, I had the opportunity to participate in an experiential learning experience at Johnson Space Center in Houston, TX with Exploration Medical Capability (ExMC), an element of the NASA Human Research Program. During this research experience, I was not only able to work on the above titled research project, but also gain an immense exposure to the field of aerospace medicine, make numerous connections within the field, tour NASA facilities, as well as travel to the Aerospace Medical Association Annual Conference (AsMA) in New Orleans. To briefly introduce my project, it is well understood that the medical capabilities available to crew medical officers (CMOs) on the International Space Station will be different than the capabilities available and needed during deep space exploration missions to the Moon, Mars, and beyond. Ground support is particularly limited due to distance, communication delays (or lack of communication), and lack of resupply. Therefore, to support medical care by CMOs on these missions, robust clinical decision support systems (CDSSs) must be designed. The recent publication and public launch of generative artificial intelligence (AI) tools based upon large language models (LLM) such as ChatGPT provides the opportunity to create a smart assistant for onboard triage, diagnosis, and treatment of medical conditions. Ultimately, the overall purpose of the project was to research what AI tools currently exist or are in development, and to see how they might be implemented onboard during exploration class spaceflights of the future. The ExMC element is actively developing several tools to be used in preparation for and during deep space exploration missions. One of those tools, known as IMPACT, is a probabilistic risk assessment model which can be used to propose a desired medical system (based on mass and volume) and suggest the clinical outcomes likely to occur for a design reference mission (DRM). The group recently presented the IMPACT model and a DRM of interest titled “Modified Long Duration Lunar Orbital and Lunar Surface” (mLDLOLS) at the recent AsMA conference. The mLDLOLS mock mission is a 9 month and 6-day deep space exploration mission consisting of time in Moon’s orbit (3 months on the Gateway space station), on the lunar surface (3 months within habitat), and another 3 months on Gateway before return to Earth. For this DRM, IMPACT ultimately outlined a preferred medical system that was then associated with medical conditions considered to be most likely based on frequency, most likely to cause astronaut task time loss (TTL), most likely to cause return to definitive care (RTDC), and most likely cause loss of crew life (LOCL). IMPACT also highlighted the medical capabilities/skills that would be required to care for those medical conditions, such as performing a history of present illness or musculoskeletal exam with ultrasound. The primary objective of the project was to perform a survey of the AI tools and systems applicable to the conditions outlined for the proposed mLDLOLS mission. Using PubMed (including most relevant MeSH terms) and Google Scholar, we then created a robust annotated bibliography organized by condition. The 56-page and over 500 reference annotated bibliography was subsequently used to create a review outline that would become the basis for drafting of a future publication. For the review outline, we took those medical conditions researched within the annotated bibliography (condition-based approach) and deployed a systems-based approach, combining those medical conditions and related tools into ten categories. These categories included general/all-purpose CDSSs, tools to diagnose or manage respiratory, dermatologic, neurologic, auditory and vestibular, ophthalmic, musculoskeletal, infection-associated, and gynecologic conditions, as well as tools that could be deployed in the setting of trauma/emergency. With the completion of the 30-page outline, we then began drafting the review paper. To conclude the research experience, I presented the findings from our survey to the ExMC Clinical and Science team. With these objectives, I ultimately learned about the number of AI tools that exist today to assist medical professionals with the triage, diagnosis, and management of several medical conditions. These tools can span from chatbot assistants to help triage knee pain to vision transformer models that can identify ophthalmic conditions based on ocular surface images captured with a cell phone. We also highlighted the current gaps that exist in the literature alongside the advancements that are needed to make the desired CDSS for deep space exploration missions. With this experience, I certainly confirmed an existing career goal and identified several additional skills needed to become an aerospace medical doctor including knowledge of critical care in an extreme medicine setting, aerospace engineering and human integration systems, artificial intelligence, machine learning, and risk models. I also identified numerous transferable skills for this career goal including the basic knowledge of medicine (MD), deployment of the scientific method for critical thought about new scientific questions (PhD), review of published literature, including creating an annotated bibliography (PhD), as well as detailed scientific writing (PhD). The results of my research will likely guide the design of an all-encompassing onboard medical assistant for use during deep space exploration missions of the future. I plan on sharing the outcomes from this experience with my peers at a student seminar in the Fall semester on August 30th. During the seminar, I will detail the project, my experience at NASA and AsMA, as well as offer best practice guidelines for students entertaining similar experiences or careers. In conclusion, I would like to thank the WVU School of Medicine, Research and Graduate Education office, as well as NASA ExMC for the unwavering support of this life-changing experience.

Ryan A. Lacinski↗

Ultrananocrystalline diamond films with optimized dielectric properties for advanced RF MEMS capacitive switches

An efficient deposition process is provided for fabricating reliable RF MEMS capacitive switches with multilayer ultrananocrystalline (UNCD) films for more rapid recovery, charging and discharging that is effective for more than a billion cycles of operation. Significantly, the deposition process is compatible for integration with CMOS electronics and thereby can provide monolithically integrated RF MEMS capacitive switches for use with CMOS electronic devices, such as for insertion into phase array antennas for radars and other RF communication systems.

36 MATERIALS SCIENCE↗

Highly-­laminated, high-­saturation-flux-­density, magnetic cores for on-­chip inductors in power converter applications

The objective of this project is development of a manufacturing process to realize thick highly-laminated metallic magnetic cores with suppressed eddy current losses for power applications and demonstration of integrated magnetic components using the process. The continual reduction in size and increase in functionality of portable electronic devices drives the development of ultracompact electrical power converters and therefore their associated inductors, which typically occupy the largest volume within the converter. This inductor size reduction can be achieved by increasing both the converter switching frequency as well as inductor operating flux density by utilizing appropriate magnetic core materials. Magnetically soft metallic alloys (e.g., NiFe and CoNiFe) are good core material candidates due to their superior magnetic properties (e.g., high saturation flux density and low coercivity) compared to conventional ferrite. However, to minimize eddy current losses, the core thickness is limited to the skin depth (typically less than 3 µm for 10 MHz operation); cores of this thickness are likely insufficient for handling high power (> 10W). Therefore, there is great interest in the development of highly-laminated metallic alloy cores with single lamination thickness in the sub-micron range to achieve suppressed eddy-current losses and high power handling capacity simultaneously. During the project, highly-laminated metallic alloy cores comprising up to 2000 layers of permalloy (Ni 80 Fe 20 ) or CoNiFe materials with single lamination thickness less than 1 µm have been fabricated based on automated multilayer electrodeposition technology compatible with CMOS manufacturing. The developed highly-laminated metallic cores preserve the high saturation flux density and low coercivity characteristics of metallic alloys, while suppressing eddy-current losses less than 1 W/cm3 at operation flux density of 0.5 T and frequency over 1 MHz. The developed highly-laminated metallic alloy cores have been further integrated into microfabricated windings to realize compact, on-chip inductors. Utilizing CMOS-compatible integration techniques, circular (toroid) and bar-shape (solenoid) microinductors have been fabricated exhibiting a constant inductance higher than 1 µH up to 50 MHz with peak quality factor as high as 35 at 5 MHz. The microfabricated inductor with highly-laminated core was tested in a power converter and demonstrated a converter efficiency of 93% at 5.5 MHz and 42 W under 100V input and 35V output operation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Sub-Threshold Low-Power Integrated Bandpass Filter for Highly-Integrated Spectrum Analyzers

Low-power analog filter banks provide frequency analysis with minimal power and space requirements, making them viable solutions for integrated remote audio- and vibration-sensing applications. Compared with their digital counterparts, analog filter banks are better suited to achieve the lower power consumption necessary for IoT applications, while maintaining high dynamic range and a wide operational frequency range. In this work, the design and implementation of a sub-threshold complementary metal-oxide semiconductor (CMOS) integrated low-power tunable analog filter channel for signal spectrum analysis and signal discrimination is presented. Project specifications required a programmable, high-order, monolithic bandpass filter channel with small chip area, low power consumption, high dynamic range, and wide operational frequency range. The 8th-order filter channel presented in this work provides an effective Q-factor of 4.5 and a minimum dynamic range (DR) of approximately 85 dB, while allowing for tuning across a range of center frequencies from 2 kHz to 100 kHz, with power consumption of a single 8th-order filter channel measured at 256 µW nominally at the highest center frequency. An integrated analog Gm-C filter topology was selected for this application. Functionally, the high-Q bandpass filter transfer function is implemented via four cascaded 2nd-order filter cells, resulting in a single 8th-order filter channel, fabricated in 130-nm 1.2-V CMOS technology, suitable for use in monolithic integrated spectral analysis (MISA1) applications.

Long, Gavin B.↗

A Sub-Threshold Low-Power Integrated Bandpass Filter for Highly-Integrated Spectrum Analyzers

Low-power analog filter banks provide frequency analysis with minimal power and space requirements, making them viable solutions for integrated remote audio- and vibration-sensing applications. Compared with their digital counterparts, analog filter banks are better suited to achieve the lower power consumption necessary for IoT applications. In this work, the design and implementation of a sub-threshold complementary metal-oxide semiconductor (CMOS) integrated low-power tunable bandpass filter channel for signal spectrum analysis and signal discrimination is presented, including performance improvements to stability and precise matching between filter stages. The 8 th -order filter channel achieves an effective Q-factor of 4.5 and dynamic range of 60 dB, has an operational frequency range from 2 kHz to 100 kHz, and consumes 256 µW nominally at the highest center frequency. An integrated analog Gm-C filter topology is selected for this application. Functionally, the high-Q bandpass filter transfer function is implemented via four cascaded 2 nd -order filter cells and is fabricated in 130-nm 1.2-V CMOS technology, making it suitable for use in monolithic integrated spectral analysis (MISA) applications.

Long, Gavin↗

Final Report for Grant

This is the final report for this project. The major objectives were to develop full models and standard cells of CMOS silicon photomultipliers (SiPM) for neutron detection applications. Specifically, the research seeks to replace photomultiplier tubes, used in neutron detection applications, with SiPMs containing integrated readout electronics fabricated in standard CMOS processes. The detectors improve on the detection efficiency, readout speed, resolution (sensitivity), and spatial resolution of current systems. In particular, this work involved collaboration with the instrument and detector group at ORNL who build detectors based on discrete commercially available PMTs and SiPMs. The SiPM detectors developed in this work are based on Perimeter Gated Single Photon Avalanche Diodes (PGSPAD). These devices have tunable breakdown voltage which affects other performance characteristics of the detectors. The ability of the detectors to have integrated readout and tune the noise floor and dynamic range in addition to offering a method for non-uniformity compensation in a compact form significantly impacts the imaging research field and includes the nuclear sciences field, circuits and systems field in addition to varied fields such as geography and biology/medicine.

42 ENGINEERING↗

Piezoelectric deformable photonic devices

A CMOS-compatible actuator platform for implementing phase, amplitude, and frequency modulation in silicon nitride photonic integrated circuits via piezo-optomechanical coupling using tightly mechanically coupled aluminum nitride actuators is disclosed. The platform, which may be fabricated in a CMOS foundry, enables scalable active photonic integrated circuits for visible wavelengths, and the piezoelectric actuation functions without performance degradation down to cryogenic operating temperatures. A number of devices are possible, including ring modulator devices, phase shifter devices, Mach-Zehnder interferometer devices, directional coupler devices (including tunable directional coupler devices), and acousto-optic modulator and frequency shifter devices, each of which can employ the same AlN actuator platform. As all of these devices can be built on the same AlN actuator platform, numerous optical functions can be implemented on a single die.

Eichenfield, Matt↗

Magnetoelectric inverter

A magneto-electric (ME) inverter includes two anti-ferromagnetic spin orbit read (AFSOR) circuit elements, each AFSOR circuit element has a CMOS inverter; and an AFSOR device with a ME base layer; a semiconductor channel layer on the ME base layer and comprising a source terminal and a drain terminal, where the source terminal is coupled to an output of the CMOS inverter; and a gate electrode on the semiconductor channel layer. The gate electrode of a second AFSOR device of the two AFSOR circuit elements is coupled to the drain terminal of a first AFSOR device of the two AFSOR circuit elements.

Gaul, Nishtha Sharma↗

Neutron counting with cameras

A research project is presented in which we aim at counting individual neutrons with CCD-like cameras. We explore theoretically a technique that allows us to use imaging detectors as counting detectors at lower counting rates, and transits smoothly to continuous imaging at higher counting rates. As such, the hope is to combine the good background rejection properties of standard neutron counting detectors with the absence of dead time of integrating neutron imaging cameras as well as their very good spatial resolution. Compared to Xray detection, the essence of thermal neutron detection is the nuclear conversion reaction. The released energies involved are of the order of a few MeV, while X-ray detection releases energies of the order of the photon energy, which is in the 10 KeV range. Thanks to advances in camera technology which have resulted in increased quantum efficiency, lower noise, as well as increased frame rate up to 100 fps for CMOS-type cameras, this more than 100-fold higher available detection energy implies that the individual neutron detection light signal can be significantly above the noise level, as such allowing for discrimination and individual counting, which is hard to achieve with X-rays. The time scale of CMOS-type cameras doesn't allow one to consider time-of-flight measurements, but kinetic experiments in the 10 ms range are possible. The theory is next confronted to the first experimental results. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Modeling of the Charge Readout of a SiMOS Quantum Dot with a Single Electron Transistor and CryoCMOS

Single electron spin qubits trapped in SiMOS quantum dots are a promising technology for scaling to thousand- or million-qubit systems due to their compatibility with mature CMOS manufacturing processes. A readout system that combines a single electron transistor with a custom cryogenic CMOS amplification and digitization chain offers key advantages by avoiding the use of bulky RF components or room-temperature interconnects. We present design techniques and simulation results for an optimized qubit-SET cryoCMOS interface, culminating in the design of the QNDR1 ASIC, the first cryogenic readout ASIC designed under the Quandarum project, which targets the development of a many-channel spin qubit based detector for use in high energy physics.

Quinn, Adam [Fermilab] (ORCID:0009000605056371)↗

Sub-Microsecond Polarization Switching in (Al,Sc)N Ferroelectric Capacitors Grown on Complementary Metal-Oxide-Semiconductor-Compatible Aluminum Electrodes

In this work, the frequency-dependent ferroelectric properties of 45 nm (Al,Sc)N films sputter deposited on complementary metal–oxide–semiconductor (CMOS)-compatible Al metal electrodes are measured and compared. Low in-plane compressive stress (-10 ± 20 MPa) is observed in (Al,Sc)N thin films deposited on Al electrodes. The (Al,Sc)N films exhibit an imprint in the measured coercive fields (E c ) of -4.3/+5.3 MV cm -1 at 10 kHz. Using positive-up negative-down (PUND) measurements, ferroelectric switching is observed within ≈200 ns of an applied voltage pulse, which demonstrates the ability of ferroelectric (Al,Sc)N to achieve the fast read/write speeds desired in memory devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Timepix4 analog front-end design: Lessons learnt on fundamental limits to noise and time resolution in highly segmented hybrid pixel detectors

This manuscript describes the optimization of the front-end readout electronics for high granularity hybrid pixel detectors. The theoretical study aims at minimizing the noise and jitter. The model presented here is validated with both circuit post layout simulations and measurements on the Timepix4 Application Specific Integrated Circuit (ASIC). The analog front-end circuit and the procedure to optimize the dimensions of the main transistors are described with detail. The Timepix4 is the most recent ASIC designed in the framework of the Medipix4 Collaboration. It was manufactured in 65nm CMOS process, and consists of a four side buttable matrix of 448 × 512 pixels with 55µm pitch. The analog front-end has a gain of ~36mV/ke - when configured in High Gain Mode, and ~20mV/ke - when configured in Low Gain Mode. The Equivalent Noise Charge (ENC) is ~68e - rms and ~80e - rms in High Gain Mode and in Low Gain Mode respectively. In event driven mode the incoming hits can be time stamped within a ~ 200ps time bin and the chip can deal with a maximum flux of ~ 3.6MHzmm –2 s –1 . In photon counting mode, the chip can deal with up to ~ 5GHzmm –2 s –1 . The routine designed to optimize the Timepix4 front-end is then used to analyze the performance limits in terms of jitter and noise for Charge Sensitive Amplifiers in pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AstroPix: A pixelated HVCMOS sensor for space-based gamma-ray measurement

A next-generation medium-energy gamma-ray telescope targeting the MeV range would address open questions in astrophysics regarding how extreme conditions accelerate cosmic-ray particles, produce relativistic jet outflows, and more. One concept, AMEGO-X, relies upon the mission-enabling CMOS Monolithic Active Pixel Sensor silicon chip AstroPix. AstroPix is designed for space-based use, featuring low noise, low power consumption, and high scalability. Desired performance of the device include an energy resolution of 5 keV (or 10% FWHM) at 122 keV and a dynamic range per-pixel of 25–700 keV, enabled by the addition of a high-voltage bias to each pixel which supports a depletion depth of 500 μ m. This work reports on the status of the AstroPix development process with emphasis on the current version under test, version three (v3), and highlights of version two (v2). Version 3 achieves energy resolution of 10.4 ± 3.2% at 59.5 keV and 94 ± 6 μ m depletion in a low-resistivity test silicon substrate.

Astrophysics instrumentation↗

Indium Tin Oxide Broadband Metasurface Absorber

Metamaterials have been designed to achieve a wide range of functionalities. Metamaterial absorbers are of particular interest for various applications such as infrared detectors, emissivity coatings, and photovoltaic cells. Various metamaterial platforms have been demonstrated to achieve perfect absorption and several attempts have been made to extend the absorption bandwidth of such devices. We demonstrate a broadband infrared absorber using an asymmetric Fabry–Perot cavity consisting of a monolithically fabricated two-layer metasurface. Superoctave optical absorption is achieved by tailoring the structure of the metasurface layers and the thickness of the cavity. Furthermore, the device yields absorptance of over 80% from λ = 4–16 μm, while maintaining the performance over a wide range of incident angles. In contrast to most metamaterial absorbers, our metasurface layers are made of customized indium tin oxide (ITO), conferring the advantage of CMOS compatibility compared to previous approaches using noble metals.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Advances in phosphor two-color ratio method thermography for full-field surface temperature measurements

We report thermographic phosphors can be employed for optical sensing of surface, gas phase, and bulk material temperatures through different strategies including the time-decay method, time-integrated method, and frequency-domain method. We focus on the time-integrated method, also known as the ratio method, as it can be more practical in many situations. This work advances the ratio method using two machine vision cameras with CMOS detectors for full-field temperature measurements of a solid surface. A phosphor calibration coupon is fabricated using aerosol deposition and employed for in situ determination of the temperature-versus-intensity ratio relationship. Algorithms from digital image correlation are employed to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. Detector nonlinearity is carefully characterized and corrected. Temperature-dependent, spatial non-uniformity of the full-field intensity ratio—posited to be caused by a blue-shift effect of the bandpass filter for non-collimated light and/or a wavelength-dependent transmission efficiency of the lens—is assessed and treated for cases where a standard flat-field correction fails to correct the non-uniformity. In sum, pixel-wise calibration curves relating the computed intensity ratio to temperature in the range of T = 300–430 K are generated, with an embedded error of less than 3 K. This work offers a full calibration methodology and several improvements on two-color phosphor thermography, opening the door for full-field temperature measurements in dynamic tests with deforming test articles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray Characterization of a Multichannel Smart-Pixel Array Detector

The Voxtel VX-798 is a prototype X-ray pixel array detector (PAD) featuring a silicon sensor photodiode array of 48 x 48 pixels, each 130 mu m x 130 mu m x 520 mu m thick, coupled to a CMOS readout application specific integrated circuit (ASIC). The first synchrotron X-ray characterization of this detector is presented, and its ability to selectively count individual X-rays within two independent arrival time windows, a programmable energy range, and localized to a single pixel is demonstrated. During our first trial run at Argonne National Laboratory's Advance Photon Source, the detector achieved a 60 ns gating time and 700 eV full width at half-maximum energy resolution in agreement with design parameters. Each pixel of the PAD holds two independent digital counters, and the discriminator for X-ray energy features both an upper and lower threshold to window the energy of interest discarding unwanted background. This smart-pixel technology allows energy and time resolution to be set and optimized in software. It is found that the detector linearity follows an isolated dead-time model, implying that megahertz count rates should be possible in each pixel. Measurement of the line and point spread functions showed negligible spatial blurring. When combined with the timing structure of the synchrotron storage ring, it is demonstrated that the area detector can perform both picosecond time-resolved X-ray diffraction and fluorescence spectroscopy measurements.

CMOS ASIC↗

Energy and Performance Benchmarking of a Domain Wall-Magnetic Tunnel Junction Multibit Adder

The domain wall (DW)-magnetic tunnel junction (MTJ) device implements universal Boolean logic in a manner that is naturally compact and cascadable. However, an evaluation of the energy efficiency of this emerging technology for standard logic applications is still lacking. In this work, we use a previously developed compact model to construct and benchmark a 32-bit adder entirely from DW-MTJ devices that communicates with DW-MTJ registers. The results of this large-scale design and simulation indicate that, while the energy cost of systems driven by spin-transfer torque (STT) domain wall motion is significantly higher than previously predicted, the same concept using spin-orbit torque (SOT) switching benefits from an improvement in the energy per operation by multiple orders of magnitude, attaining competitive energy values relative to a comparable CMOS sub-processor component. This result clarifies the path towards practical implementations of an all-magnetic processor system.

42 ENGINEERING↗