Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Instrumentation and Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Gain and offset calibration reduces variation in exposure-dependent SNR among systems with identical digital flat-panel detectors

Purpose: The conditions under which vendor performance criteria for digital radiography systems are obtained do not adequately simulate the conditions of actual clinical imaging with respect to radiographic technique factors, scatter production, and scatter control. Therefore, the relationship between performance under ideal conditions and performance in clinical practice remains unclear. Using data from a large complement of systems in clinical use, the authors sought to develop a method to establish expected performance criteria for digital flat-panel radiography systems with respect to signal-to-noise ratio (SNR) versus detector exposure under clinical conditions for thoracic imaging. Methods: The authors made radiographic exposures of a patient-equivalent chest phantom at 125 kVp and 180 cm source-to-image distance. The mAs value was modified to produce exposures above and below the mAs delivered by automatic exposure control. Exposures measured free-in-air were corrected to the imaging plane by the inverse square law, by the attenuation factor of the phantom, and by the Bucky factor of the grid for the phantom, geometry, and kilovolt peak. SNR was evaluated as the ratio of the mean to the standard deviation (SD) of a region of interest automatically selected in the center of each unprocessed image. Data were acquired from 18 systems, 14 of which were tested both before and after gain and offset calibration. SNR as a function of detector exposure was interpolated using a double logarithmic function to stratify the data into groups of 0.2, 0.5, 1.0, 2.0, and 5.0 mR exposure (1.8, 4.5, 9.0, 18, and 45 {mu}Gy air KERMA) to the detector. Results: The mean SNR at each exposure interval after calibration exhibited linear dependence on the mean SNR before calibration (r{sup 2} = 0.9999). The dependence was greater than unity (m = 1.101 {+-} 0.006), and the difference from unity was statistically significant (p < 0.005). The SD of mean SNR after calibration also exhibited linear dependence on the SD of the mean SNR before calibration (r{sup 2} = 0.9997). This dependence was less than unity (m = 0.822 {+-} 0.008), and the difference from unity was also statistically significant (p < 0.005). Systems were separated into two groups: systems with a precalibration SNR higher than the median SNR (N = 7), and those with a precalibration SNR lower than the median SNR (N = 7). Posthoc analysis was performed to correct for expanded false positive results. After calibration, the authors noted differences in mean SNR within both high and low groups, but these differences were not statistically significant at the 0.05 level. SNR data from four additional systems and one system from those previously tested after replacement of its detector were compared to the 95% confidence intervals (CI) calculated from the postcalibration SNR data. The comparison indicated that four of these five systems were consistent with the CI derived from the previously tested 14 systems after calibration. Two systems from the paired group that remained outside the CI were studied further. One system was remedied with a grid replacement. The nonconformant behavior of the other system was corrected by replacing the image receptor. Conclusions: Exposure-dependent SNR measurements under conditions simulating thoracic imaging allowed us to develop criteria for digital flat-panel imaging systems from a single manufacturer. These measurements were useful in identifying systems with discrepant performance, including one with a defective grid, one with a defective detector, and one that had not been calibrated for gain and offset. The authors also found that the gain and offset calibration reduces variation in exposure-dependent SNR performance among the systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magellan Mission

The Magellan spacecraft was launched from Cape Kennedy on 4 May 1989 and was inserted into orbit around Venus on 10 Aug. 1990. The Magellan spacecraft carries a radar instrument that makes synthetic aperture radar (SAR) images of the surface, measures the altitude of the Venusian surface directly below the spacecraft, and obtains radiometric observations of the surface. Radar and radiometric observations of the Venusian surface commenced on 15 Sep. 1990 and continued until 15 Sep. 1992. Gravity observations began on 24 Sep. 1992 and will continue until late May 1993. The radar observations produced SAR images and surface topography for 99 percent of the surface. These radar observations support the objective of improving the knowledge of the geological history of Venus by analysis of surface morphology and the processes that control them. The gravity observations that are being conducted now support the Magellan objective of improving the knowledge of the geophysics of Venus, principally its density distribution and dynamics. Also, Magellan generated more digital planetary image data than all previous planetary missions.

Thompson, Thomas W.↗

Development of Thermal Infrared Sensor to Supplement Operational Land Imager

The thermal infrared sensor (TIRS) is a quantum well infrared photodetector (QWIP)-based instrument intended to supplement the Operational Land Imager (OLI) for the Landsat Data Continuity Mission (LDCM). The TIRS instrument is a far-infrared imager operating in the pushbroom mode with two IR channels: 10.8 and 12 m. The focal plane will contain three 640 ~512 QWIP arrays mounted onto a silicon substrate. The readout integrated circuit (ROIC) addresses each pixel on the QWIP arrays and reads out the pixel value (signal). The ROIC is controlled by the focal plane electronics (FPE) by means of clock signals and bias voltage value. The means of how the FPE is designed to control and interact with the TIRS focal plane assembly (FPA) is the basis for this work. The technology developed under the FPE is for the TIRS focal plane assembly (FPA). The FPE must interact with the FPA to command and control the FPA, extract analog signals from the FPA, and then convert the analog signals to digital format and send them via a serial link (USB) to a computer. The FPE accomplishes the described functions by converting electrical power from generic power supplies to the required bias power that is needed by the FPA. The FPE also generates digital clocking signals and shifts the typical transistor-to-transistor logic (TTL) to }5 V required by the FPA. The FPE also uses an application- specific integrated circuit (ASIC) named System Image, Digitizing, Enhancing, Controlling, And Retrieving (SIDECAR) from Teledyne Corp. to generate the clocking patterns commanded by the user. The uniqueness of the FPE for TIRS lies in that the TIRS FPA has three QWIP detector arrays, and all three detector arrays must be in synchronization while in operation. This is to avoid data skewing while observing Earth flying in space. The observing scenario may be customized by uploading new control software to the SIDECAR.

Shu, Peter↗

Event-driven readout development: testing of the EDWARD65P1 chip with integrated event generators

Building on a prototype readout integrated circuit for segmented silicon sensors with the EDWARD event-driven readout architecture, the front-end in each pixel was replaced by a hardware generator to verify readout performance, ensuring no data loss, consistent priority handling, and speed verification. Here, this generator produces Poisson-distributed readout requests with individually tunable rates per pixel via a digitally controlled oscillator. The resulting EDWARD65P1 test ASIC is a 32×32 pixel matrix with a 100 μm pitch, equipped with digital event generators simulating radiation hits at user-defined rates. Test results for this new design are presented.

47 OTHER INSTRUMENTATION↗

Knowledge-based imaging-sensor fusion system

An imaging system which applies knowledge-based technology to supervise and control both sensor hardware and computation in the imaging system is described. It includes the development of an imaging system breadboard which brings together into one system work that we and others have pursued for LaRC for several years. The goal is to combine Digital Signal Processing (DSP) with Knowledge-Based Processing and also include Neural Net processing. The system is considered a smart camera. Imagine that there is a microgravity experiment on-board Space Station Freedom with a high frame rate, high resolution camera. All the data cannot possibly be acquired from a laboratory on Earth. In fact, only a small fraction of the data will be received. Again, imagine being responsible for some experiments on Mars with the Mars Rover: the data rate is a few kilobits per second for data from several sensors and instruments. Would it not be preferable to have a smart system which would have some human knowledge and yet follow some instructions and attempt to make the best use of the limited bandwidth for transmission. The system concept, current status of the breadboard system and some recent experiments at the Mars-like Amboy Lava Fields in California are discussed.

Westrom, George↗

ALICE inner tracking system readout electronics prototype testing with the CERN "Giga Bit Transceiver''

The ALICE Collaboration is preparing a major detector upgrade for the LHC Run 3, which includes the construction of a new silicon pixel based Inner Tracking System (ITS). The ITS readout system consists of 192 readout boards to control the sensors and their power system, receive triggers, and deliver sensor data to the DAQ. To prototype various aspects of this readout system, an FPGA based carrier board and an associated FMC daughter card containing the CERN Gigabit Transceiver (GBT) chipset have been developed. Furthermore, this contribution describes laboratory and radiation testing results with this prototype board set.

47 OTHER INSTRUMENTATION↗

Demonstration of thermal control, microstructure control, defect mitigation and process parameter database generation for Ti-6Al-4V Direct Digital Manufacturing - Understanding defect mitigation and process parameter database generation for direct digital manufacturing

Researchers from Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory (ORNL) worked with Applied Optimization (AO) to understand and evaluate the propensity for defect formation in builds manufactured using DM3D-POM laser direct metal deposition. The main aim of this collaboration was to understand the character of powder jet behavior as a function of the nozzle parameters such as cover gas, carrier gas, and shaping gas. In order to evaluate the sensitivities of the parameters used in model, various experiments were performed with in-situ monitoring of the powder stream characteristics using a high speed camera. A wide variety of conditions while keeping the hopper motor rpm constant, including laser power and travel speed were explored. The cross sections of the deposits were characterized using optical microscopy.

47 OTHER INSTRUMENTATION↗

A high-overtone bulk acoustic wave resonator-oscillator-based 4.596 GHz frequency source: Application to a coherent population trapping Cs vapor cell atomic clock

This article reports on the design and characterization of a high-overtone bulk acoustic wave resonator (HBAR)-oscillator-based 4.596 GHz frequency source. A 2.298 GHz signal, generated by an oscillator constructed around a thermally controlled two-port aluminum nitride-sapphire HBAR resonator with a Q-factor of 24 000 at 68 °C, is frequency multiplied by 2–4.596 GHz, half of the Cs atom clock frequency. The temperature coefficient of frequency of the HBAR is measured to be −23 ppm/ °C at 2.298 GHz. The measured phase noise of the 4.596 GHz source is −105 dB rad{sup 2}/Hz at 1 kHz offset and −150 dB rad{sup 2}/Hz at 100 kHz offset. The 4.596 GHz output signal is used as a local oscillator in a laboratory-prototype Cs microcell-based coherent population trapping atomic clock. The signal is stabilized onto the atomic transition frequency by tuning finely a voltage-controlled phase shifter implemented in the 2.298 GHz HBAR-oscillator loop, preventing the need for a high-power-consuming direct digital synthesis. The short-term fractional frequency stability of the free-running oscillator is 1.8 × 10{sup −9} at one second integration time. In locked regime, the latter is improved in a preliminary proof-of-concept experiment at the level of 6.6 × 10{sup −11} τ{sup −1/2} up to a few seconds and found to be limited by the signal-to-noise ratio of the detected CPT resonance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An integer- N frequency synthesizer for flexible on-chip clock generation

A low-power integer-N frequency synthesizer for flexible on-chip clock generation has been designed in a 65 nm CMOS process. The circuit can be programmed to generate two independent low-jitter clocks between 30 MHz and 3 GHz that are locked to a 10–50 MHz reference input. The design uses a phase-locked loop (PLL) with a dual-tuned LC voltage-controlled oscillator (VCO), programmable feedback divider, and dual output dividers. The total power consumption from 1.2 V and 0.8 V supplies is 4.0 mW. In conclusion, experimental results confirm the functionality of the proposed synthesizer over a wide range of output frequencies.

47 OTHER INSTRUMENTATION↗

Avionics/crew station integration

The U.S. Navy has been encouraging advanced development concepts aimed at increasing the aircraft instrumentation performance for multi-platform applications of 1990's weapons systems. The three areas covered by the Navy's research and development effort are: System Integration, Technology, and Human Factors. The System Integration objectives are to produce a system architecture easily adaptable to many platforms. Technology objectives are to determine the state of the art for displays, electronics, and controls. The Human Factors objectives are to determine the proper human-machine interfaces so that the ultimate crew station will be capable of providing the pilot with the proper display and controls performance to satisfy the diverse requirements of a fighter, attack, ASW, fixed-wing, rotary-wing, and V/STOL platforms in both a one-man crew or two-man crew matrix. All data/control interface among units of this crew station and other platform subsystems will be via digital data buses and video multiplex buses. No individual discrete signal, data, or control lines will be needed. This paper discusses the six interfaces necessary to ensure the optimum development of this crew station, the predicted platform mission improvements, and the requisite life-cycle cost considerations. This concept will serve as a basis for planning the integration of the necessary hardware and software features in current and future weapons systems.

Mulley, W. G.↗

Computerized procedure systems: procedure edition and maintenance challenges - 232

Very few nuclear power plants are using computerized procedures to guide the control room operation. A CPS implementation consists of two processes: digitalization and computerization. The former deals with the transformation of paper-based procedure into a digital data; the latter is referred to as the addition to that data of extra information that is meaningful for decision-making. This information may include real-time data (plant parameter values and binary process values to indicate equipment states), provide access to trends and historical data, etc. In order to be efficient and to optimize the digitalization and computerization processes, these set of aids should be implemented at the same time as operating procedures are digitalized There are references of plants having successfully implemented Computerized Procedures Systems (CPS) for emergency procedures, but when questioned about normal or abnormal operating procedures, operators and plant management seem reluctant to take that step. Given that a CPS is meant, by design concept, to increase operation crew efficiency by facilitating the procedures execution and reducing human error, why are we reluctant to enjoy CPS benefits in the most common plant status (i.e. normal operation)? Although there are many answers to this question, one is shared by most of the users: CPSs are not designed for editing and maintaining procedures easily and reliably. Normal operating procedures, in opposition to the emergency procedures, are often reviewed. Nowadays, these edition activities are performed easily with a word processor software and using paper, but what is required when dealing with a CPS? (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Deciphering the Precision of Stereo IKONOS Canopy Height Models for U.S. Forests with G-LiHT Airborne LiDAR

Few studies have evaluated the precision of IKONOS stereo data for measuring forest canopy height. The high cost of airborne light detection and ranging (LiDAR) data collection for large area studies and the present lack of a spaceborne instrument lead to the need to explore other low cost options. The US Government currently has access to a large archive of commercial high-resolution imagery, which could be quite valuable to forest structure studies. At 1 m resolution, we here compared canopy height models (CHMs) and height data derived from Goddard's airborne LiDAR Hyper-spectral and Thermal Imager (G-LiHT) with three types of IKONOS stereo derived digital surface models (DSMs) that estimate CHMs by subtracting National Elevation Data (NED) digital terrain models (DTMs). We found the following in three different forested regions of the US after excluding heterogeneous and disturbed forest samples: (1) G-LiHT DTMs were highly correlated with NED DTMs with R (sup 2) greater than 0.98 and root mean square errors (RMSEs) less than 2.96 m; (2) when using one visually identifiable ground control point (GCP) from NED, G-LiHT DSMs and IKONOS DSMs had R (sup 2) greater than 0.84 and RMSEs of 2.7 to 4.1 m; and (3) one GCP CHMs for two study sites had R (sup 2) greater than 0.7 and RMSEs of 2.6 to 3 m where data were collected less than four years apart. Our results suggest that IKONOS stereo data are a useful LiDAR alternative where high-quality DTMs are available.

IKONOS↗

Human Performance Measures for the Evaluation of Nuclear Power Plant Control Room Interfaces: A Systematic Review - 265

The purpose of this study was to review the literature related to measuring human performance in the design and evaluation of the human-system interface (HSI) of nuclear power plant (NPP) control rooms and synthesize lessons learned and future directions for research and practice in this field. The design and evaluation of digital or hybrid HSI requires comprehensive measurement of human performance to ensure quality and safety of the nuclear power process control. Human factors evaluation frameworks have been proposed to guide the measurement of human performance constructs. However, there are few guides for selecting appropriate measures for those constructs. A systematic review of empirical research literature was conducted. Studies were identified through academic publication databases and grey literature searches. Eligible studies were coded and information regarding human performance measures was extracted and analyzed. A total of 80 studies met the criteria. Human performance measures extracted from the reviewed studies included measures of: behavioral performance; workload; situation awareness; human-human or human-machine cooperation; other cognitive performance indicators; and system performance. Behavioral performance (speed and accuracy), workload, and situation awareness were the most frequently measured constructs with validated and domain-specific instruments. The results of the literature review provided an overview of the human performance constructs and their corresponding measures for NPP control room HSI evaluation. These results can be used as an initial guide to establish appropriate and comprehensive measurements of human performance for such evaluations. Future directions in measure development are also discussed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Imaging photomultiplier array with integrated amplifiers and high-speed USB interface

Multianode photomultiplier tube (PMT) arrays are finding application as convenient high-speed light sensitive devices for plasma imaging. This paper describes the development of a USB-based 'plug-n-play' 16-channel PMT camera with 16 bits simultaneous acquisition of 16 signal channels at rates up to 2 MS/s per channel. The preamplifiers and digital hardware are packaged in a compact housing which incorporates magnetic shielding, on-board generation of the high-voltage PMT bias, an optical filter mount and slits, and F-mount lens adaptor. Triggering, timing, and acquisition are handled by four field-programmable gate arrays (FPGAs) under instruction from a master FPGA controlled by a computer with a LABVIEW interface. We present technical design details and specifications and illustrate performance with high-speed images obtained on the H-1 heliac at the ANU.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ nanomechanical testing in focused ion beam and scanning electron microscopes

The recent interest in size-dependent deformation of micro- and nanoscale materials has paralleled both technological miniaturization and advancements in imaging and small-scale mechanical testing methods. Here we describe a quantitative in situ nanomechanical testing approach adapted to a dual-beam focused ion beam and scanning electron microscope. A transducer based on a three-plate capacitor system is used for high-fidelity force and displacement measurements. Specimen manipulation, transfer, and alignment are performed using a manipulator, independently controlled positioners, and the focused ion beam. Gripping of specimens is achieved using electron-beam assisted Pt-organic deposition. Local strain measurements are obtained using digital image correlation of electron images taken during testing. Examples showing results for tensile testing of single-crystalline metallic nanowires and compression of nanoporous Au pillars will be presented in the context of size effects on mechanical behavior and highlight some of the challenges of conducting nanomechanical testing in vacuum environments.

36 MATERIALS SCIENCE↗

A modular, programmable measurement system for physiological and spaceflight applications

The NASA-Ames Sensors 2000! Program has developed a small, compact, modular, programmable, sensor signal conditioning and measurement system, initially targeted for Life Sciences Spaceflight Programs. The system consists of a twelve-slot, multi-layer, distributed function backplane, a digital microcontroller/memory subsystem, conditioned and isolated power supplies, and six application-specific, physiological signal conditioners. Each signal condition is capable of being programmed for gains, offsets, calibration and operate modes, and, in some cases, selectable outputs and functional modes. Presently, the system has the capability for measuring ECG, EMG, EEG, Temperature, Respiration, Pressure, Force, and Acceleration parameters, in physiological ranges. The measurement system makes heavy use of surface-mount packaging technology, resulting in plug in modules sized 125x55 mm. The complete 12-slot system is contained within a volume of 220x150x70mm. The system's capabilities extend well beyond the specific objectives of NASA programs. Indeed, the potential commercial uses of the technology are virtually limitless. In addition to applications in medical and biomedical sensing, the system might also be used in process control situations, in clinical or research environments, in general instrumentation systems, factory processing, or any other applications where high quality measurements are required.

Hines, John W.↗

Test Cases for Flutter of the Benchmark Models Rectangular Wings on the Pitch and Plunge Apparatus

The supercritical airfoil was chosen as a relatively modem airfoil for comparison. The BOO12 model was tested first. Three different types of flutter instability boundaries were encountered, a classical flutter boundary, a transonic stall flutter boundary at angle of attack, and a plunge instability near M = 0.9 and for zero angle of attack. This test was made in air and was Transonic Dynamics Tunnel (TDT) Test 468. The BSCW model (for Benchmark SuperCritical Wing) was tested next as TDT Test 470. It was tested using both with air and a heavy gas, R-12, as a test medium. The effect of a transition strip on flutter was evaluated in air. The B64AOlO model was subsequently tested as TDT Test 493. Some further analysis of the experimental data for the BOO12 wing is presented. Transonic calculations using the parameters for the BOO12 wing in a two-dimensional typical section flutter analysis are given. These data are supplemented with data from the Benchmark Active Controls Technology model (BACT) given and in the next chapter of this document. The BACT model was of the same planform and airfoil as the BOO12 model, but with spoilers and a trailing edge control. It was tested in the heavy gas R-12, and was instrumented mostly at the 60 per cent span. The flutter data obtained on PAPA and the static aerodynamic test cases from BACT serve as additional data for the BOO12 model. All three types of flutter are included in the BACT Test Cases. In this report several test cases are selected to illustrate trends for a variety of different conditions with emphasis on transonic flutter. Cases are selected for classical and stall flutter for the BSCW model, for classical and plunge for the B64AOlO model, and for classical flutter for the BOO12 model. Test Cases are also presented for BSCW for static angles of attack. Only the mean pressures and the real and imaginary parts of the first harmonic of the pressures are included in the data for the test cases, but digitized time histories have been archived. The data for the test cases are available as separate electronic files. An overview of the model and tests is given, the standard formulary for these data is listed, and some sample results are presented.

Robert M Bennett↗

Intermediate frequency band digitized high dynamic range radiometer system for plasma diagnostics and real-time Tokamak control

An intermediate frequency (IF) band digitizing radiometer system in the 100-200 GHz frequency range has been developed for Tokamak diagnostics and control, and other fields of research which require a high flexibility in frequency resolution combined with a large bandwidth and the retrieval of the full wave information of the mm-wave signals under investigation. The system is based on directly digitizing the IF band after down conversion. The enabling technology consists of a fast multi-giga sample analog to digital converter that has recently become available. Field programmable gate arrays (FPGA) are implemented to accomplish versatile real-time data analysis. A prototype system has been developed and tested and its performance has been compared with conventional electron cyclotron emission (ECE) spectrometer systems. On the TEXTOR Tokamak a proof of principle shows that ECE, together with high power injected and scattered radiation, becomes amenable to measurement by this device. In particular, its capability to measure the phase of coherent signals in the spectrum offers important advantages in diagnostics and control. One case developed in detail employs the FPGA in real-time fast Fourier transform (FFT) and additional signal processing. The major benefit of such a FFT-based system is the real-time trade-off that can be made between frequency and time resolution. For ECE diagnostics this corresponds to a flexible spatial resolution in the plasma, with potential application in smart sensing of plasma instabilities such as the neoclassical tearing mode (NTM) and sawtooth instabilities. The flexible resolution would allow for the measurement of the full mode content of plasma instabilities contained within the system bandwidth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗