Search NASA⌕ Search

SEARCH · Search NASA

Results for “Generating Site”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

System Study: Emergency Power System 1998-2014

This report presents an unreliability evaluation of the emergency power system (EPS) at 104 U.S. commercial nuclear power plants. Demand, run hours, and failure data from fiscal year 1998 through 2014 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. An extremely statistically significant increasing trend was observed for EPS system unreliability for an 8-hour mission. A statistically significant increasing trend was observed for EPS system start-only unreliability.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of an In-Situ Method for Cable Condition Monitoring in Nuclear Power Plants (SBIR Phase IIB Final Report)

This is the final report of a Small Business Innovation Research (SBIR) project that Analysis and Measurement Services Corporation (AMS) has conducted for the U.S. Department of Energy (DOE) over a seven-and-a-half year period (February 2013 through April 2020 with the awards of Phase I, Phase II and Phase IIB projects). The goal of the project was to design, develop, validate, and demonstrate a technique for in-situ testing of cable insulation polymers that will identify, locate, and provide the degree of aging for cables commonly used in nuclear power plants. During the Phase I project, AMS established that the frequency domain reflectometry (FDR) technique can successfully identify and measure cable insulation degradation that can be trended with aging. In Phase II, AMS performed extensive cable aging studies to correlate FDR measurements with other laboratory condition monitoring techniques and developed aging condition categories to quantify the severity of insulation degradation. In Phase IIB, the project expanded the research to include a wider variety of cable polymers that are used in the commercial nuclear power industry. This work also involved developing acceptance criteria to objectively assess age-related cable degradation while sharing the results of this research with industry, academia, and national laboratories to advance the state of the art in cable aging management technologies. The products developed under this research project provide the nuclear industry with an effective condition monitoring tool to support safe and long-term plant operation. Throughout the project, collaborations and support were received from a variety of industry organizations and individuals including DOE National Laboratories as well as nuclear plant utilities and several other industry experts and cable manufacturers. Contributions from these organizations included the donation of new cables, naturally aged cables, and research collaboration. The validation and commercialization of the products of this project were achieved through opportunities to test and demonstrate the technologies’ capabilities on-site at nuclear power generation and research facilities as well as in the laboratory alongside industry peers and cable testing service companies. The research resulted in a technology that can be used to identify, locate, and quantify age-related degradation in several types of cable polymers. This included developing software and hardware as well as the methodology for using the FDR technique to assess age-related degradation of installed cables. The technology developed under this project can provide nuclear plant management, engineers, and technicians with an in-situ electrical test method to determine if in-service cables need to be replaced, monitored on a periodic basis, or show no evidence of significant age-related degradation that may require action. Near the end of this Phase IIB project, the FDR product was sold to a nuclear power utility in South Korea. This sale of a dedicated aging assessment tool is the beginning of a comprehensive contract with the expectation of twelve (12) units sold to that country. Additionally, the FDR technology has been sold to several industry organizations including a nuclear research institute and the Diablo Canyon nuclear power plant. This technology is also being leased by other nuclear industry service companies for incorporation into aging management programs. The cable testing technology that was developed under this project was also integrated into a comprehensive cable aging assessment service that is being offered to the nuclear industry at the request of U.S. nuclear utilities and is currently part of onsite testing services provided by AMS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Climate Vulnerability Assessment and Resilience Planning for Idaho National Laboratory

Idaho National Laboratory’s (INL’s) mission is to discover, demonstrate, and secure innovative nuclear energy solutions, other clean energy options, and critical infrastructure. This INL’s Climate Vulnerability Assessment and Resilience Plan (VARP) was developed to enable and sustain that mission while ensuring the viability of operations considering expected climate change impacts. The VARP was developed according to the narrative requirements from the “Vulnerability Assessment and Resilience Planning Guidance, Version 1.2” document issued in February 2022. A prescribed process was used to identify mission-critical systems and components, determine historical and expected climate impacts, and develop resilient solutions. Experts from across INL, including operations staff, researchers, and climate scientists supplied input to the process. Analyses of climate modeling sources revealed that under scenarios of higher and lower greenhouse gas emissions (Representative Concentration Pathway (RCP) 4.5 and RCP 8.5), INL anticipates an increase in climate hazards, including drought, heat waves, wildfire, and precipitation. Increased frequency and duration of climatic hazards forecasts high impacts on certain mission-critical asset and infrastructure types. Utilizing the VARP Risk Assessment Tool, projected high climate hazard impacts across multiple asset and infrastructure types at the INL include energy generation and distribution systems, Site buildings, specialized or mission-critical equipment, and transportation and fleet infrastructure. Some of these mission-critical asset and infrastructure types maintain high adaptive capacity to climatic changes; however, others may need additional adaptive capacity to withstand increased frequency and duration of climate hazards. INL identified close to 300 resilient solutions that were consolidated into 11 solution categories to be tracked in the Department of Energy Sustainability Dashboard. The identified solutions are a starting point for future project development and analysis. These data are intended to inform decision makers on climate issues and potential solutions across INL and associated communities. The VARP is not intended to be a budget tool or project decision document on its own, but rather one of many tools used by decision makers to establish resilient priorities. This initial document provides the framework and foundation to resilient solutions. In the coming years, each solution needs to be fully developed, costed, and prioritized based on mission-critical risk and funding priorities.

54 ENVIRONMENTAL SCIENCES↗

Prairie State Generating Company Static and Dynamic Modeling

A reservoir modeling study was conducted to assess the feasibility of storing 162.5 million tonnes (8.125 million tonnes annually) of industrially sourced carbon dioxide (CO 2 ) in the St. Peter – Everton and Knox storage complexes at the Prairie State Generating Company’s (PSGC) site near Marissa, Washington County, Illinois (PSGC site). Two separate models were constructed for the St. Peter – Everton and the Knox storage complexes. The St. Peter and Everton sandstones are the target storage units for the St. Peter – Everton storage complex. The Knox Group formations are the target storage units for the Knox storage complex. The Maquoketa Shale is the primary confining unit for both storage complexes. The static reservoir models used as input to the dynamic reservoir models of the storage complexes were developed from interpretations of logs (e.g., gamma ray, resistivity, porosity, photoelectric, and sonic), structure surfaces using data from 36 wells, thickness maps, well test data, seismic data, and permeability data in PetrelTM.

01 COAL, LIGNITE, AND PEAT↗

Wind for Schools: A Wind Powering America Project

This brochure serves as an introduction to Wind Powering America's Wind for Schools Project, including a description of the project, the participants, funding sources, and the basic configurations of the project.

17 WIND ENERGY↗

Fifty-Five Gallon Drum Standard Study [Slides]

This presentation covers a Fifty-Five Gallon Drum Standard Study. This lecture finds that decontamination and decommissioning and legacy wastes is similar across most Sites. Additionally, Information on legacy wastes vary with site and original waste generation date. Finally, this presentation concludes with the discovery that different goals and modeling assumptions lead to a wide range in fissile mass limits for 55-Gallon waste drums.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NAVAJO ELECTRIFICATION DEMONSTRATION PROJECT

The Navajo Electrification Demonstration Project (NEDP) is a multi-year project which addresses the electricity needs of the unserved and underserved Navajo Nation, the largest American Indian tribe in the United States. The program serves to cumulatively provide off-grid electricty for families living away from the electricty infrastructure, line extensions for unserved families living nearby (less than 1/2 mile away from) the electricity, and, under the current project called NEDP-4, the construction of a substation to increase the capacity and improve the quality of service into the central core region of the Navajo Nation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Failure and Redemption of Multifilter Rotating Shadowband Radiometer (MFRSR)/Normal Incidence Multifilter Radiometer (NIMFR) Cloud Screening: Contrasting Algorithm Performance at Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) and Southern Great Plains (SGP) Sites

Well-known cloud-screening algorithms, which are designed to remove cloud-contaminated aerosol optical depths (AOD) from AOD measurements, have shown great performance at many middle-to-low latitude sites around the world. However, they may occasionally fail under challenging observational conditions, such as when the sun is low (near the horizon) or when optically thin clouds with small spatial inhomogeneity occur. Such conditions have been observed quite frequently at the high-latitude Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) sites. A slightly modified cloud-screening version of the standard algorithm is proposed here with a focus on the ARM-supported Multifilter Rotating Shadowband Radiometer (MFRSR) and Normal Incidence Multifilter Radiometer (NIMFR) data. The modified version uses approximately the same techniques as the standard algorithm, but it additionally examines the magnitude of the slant-path line of sight transmittance and eliminates points when the observed magnitude is below a specified threshold. Substantial improvement of the multi-year (1999-2012) aerosol product (AOD and its Angstrom exponent) is shown for the NSA sites when the modified version is applied. Moreover, this version reproduces the AOD product at the ARM Southern Great Plains (SGP) site, which was originally generated by the standard cloud-screening algorithms. The proposed minor modification is easy to implement and its application to existing and future cloud-screening algorithms can be particularly beneficial for challenging observational conditions.

aerosol↗

CCPP-ARM Parameterization Testbed Model Forecast Data

Dataset contains the NCAR CAM3 (Collins et al., 2004) and GFDL AM2 (GFDL GAMDT, 2004) forecast data at locations close to the ARM research sites. These data are generated from a series of multi-day forecasts in which both CAM3 and AM2 are initialized at 00Z every day with the ECMWF reanalysis data (ERA-40), for the year 1997 and 2000 and initialized with both the NASA DAO Reanalyses and the NCEP GDAS data for the year 2004. The DOE CCPP-ARM Parameterization Testbed (CAPT) project assesses climate models using numerical weather prediction techniques in conjunction with high quality field measurements (e.g. ARM data).

54 ENVIRONMENTAL SCIENCES↗

Sensitivity to emotional ill health

The services of mental specialists, such as psychologists, psychiatrists, or psychiatric social workers are required to assure maximum human performance in Government facilities. Contemporary mental health programming covers emotionally generated problems at operational sites to complete disclaiming of the existence of such difficulties among workers. Frequent taking of sick leave or annual leave when work seems demanding or when a promotion does not materialize, chronic or repeated tardiness, requests for frequent transfers, work over-loading, accidental injuries, and alcoholism are all forms of stress responses and indicate a need for emotional counselling.

Felton, J. S.↗

Investigation of environmental indices from the Earth Resources Technology Satellite

The author has identified the following significant results. Land use, quality, and air quality trends are being deduced from both ERTS-1 MSS and computer compatible tapes. The data analysis plan and the preliminary data analysis phase were conducted in January 1973. Results from these two phases are: (1) Method of analysis has been selected and checked out. (2) Land use for two dates have been generated for one test site. (3) Water quality for one date has been produced partially. (4) Air quality for three has been produced and compared with ground truth. (5) One of the two DCP stations is in operation; the second station will be installed in March 1973. Land use classification exceeds pre-launch expectations. Water quality (turbidity) is not progressing as expected. Finally, mesoscale air quality results have shown correlation with NOAA/EPA turbidity network. If air quality correlations continue to show favorable results, a rapid means of global turbidity may be available from ERTS-1 MSS observations.

Greeley, R. S.↗

Solar heating and cooling buildings

Sunshine is available in differing amounts everywhere in the world and the easiest method of capturing it is by absorption in the form of thermal energy (heat). Therefore, it is logical to utilize it directly in the heating and cooling of buildings and avoid losses that would occur by conversion to some other form. It may be emphasized that of the total energy consumed annually in the U.S., about 25% is used for heating and cooling in buildings. It is generally agreed that of all the possible widespread uses of solar energy, this application has the highest probability of success in the near term. Although there are significant uncertainties associated with some technological and economic aspects, they do not loom as large as those associated with other potentially significant applications, such as electrical power generation. It may, however, be noted that solar electrical power generation at the building site, or at a centralized station is an excellent long term prospect. Approximately 25 experimental solar heated structures have been built in various parts of the world.

Source record↗

Hypersonic research engine project. Phase 2: Aerothermodynamic Integration Model (AIM) data reduction computer program, data item no. 54.16

The data reduction program used to analyze the performance of the Aerothermodynamic Integration Model is described. Routines to acquire, calibrate, and interpolate the test data, to calculate the axial components of the pressure area integrals and the skin function coefficients, and to report the raw data in engineering units are included along with routines to calculate flow conditions in the wind tunnel, inlet, combustor, and nozzle, and the overall engine performance. Various subroutines were modified and used to obtain species concentrations and transport properties in chemical equilibrium at each of the internal and external engine stations. It is recommended that future test plans include the configuration, calibration, and channel assignment data on a magnetic tape generated at the test site immediately before or after a test, and that the data reduction program be designed to operate in a batch environment.

Gaede, A. E.↗

Solar thermionic power systems for terrestrial applications

The results of a feasibility study which showed that a low-temperature, high-efficient thermionic power system can efficiently convert solar energy to electrical energy without heat transport, as required by most solar thermal systems are described. A 3-dimensional (2-axis tracking) 93 sq m parabolic solar concentrator, consisting of mirrors on a foam glass substrate and designed to a concentration ratio (mirror area/aperture area) of 2000 is considered for producing a design temperature of 1100 C at an efficiency of 74%. A tracking subsystem must track the sun at an accuracy of a nominal plus or minus 1.0 degree for maximum use of the sun's energy. Each complete solar thermionic power system unit rated at about 20 kWe peak can generate approximately 48,000 kWh/yr. In addition, a thermal energy conversion system can be cascaded within the thermionic power system so that the high quality waste heat can be further utilized to increase the net electrical output. Potential applications of a solar thermionic power generation system are remote sites, apartment house complexes, heating and cooling, hydrogen production and large power stations.

Shimada, K.↗