Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Holographic Imaging of Evolving Laser-Plasma Structures

In the 1870s, English photographer Eadweard Muybridge captured motion pictures within one cycle of a horse’s gallop, which settled a hotly debated question of his time by showing that the horse became temporarily airborne. In the 1940s, Manhattan project photographer Berlin Brixner captured a nuclear blast at a million frames per second, and resolved a dispute about the explosion’s shape and speed. In this project, we developed methods to capture detailed motion pictures of evolving, light-velocity objects created by a laser pulse propagating through matter. These objects include electron density waves used to accelerate charged particles, laser-induced refractive index changes used for micromachining, and ionization tracks used for atmospheric chemical analysis, guide star creation and ranging. Our “movies”, like Muybridge’s and Brixner’s, are obtained in one shot, since the laser-created objects of interest are insufficiently repeatable for accurate stroboscopic imaging. Our high-speed photographs have begun to resolve controversies about how laser-created objects form and evolve, questions that previously could be addressed only by intensive computer simulations based on estimated initial conditions. Resolving such questions helps develop better tabletop particle accelerators, atmospheric ranging devices and many other applications of laser-matter interactions. Our photographic methods all begin by splitting one or more “probe” pulses from the laser pulse that creates the light-speed object. A probe illuminates the object and obtains information about its structure without altering it. We developed three single-shot visualization methods that differ in how the probes interact with the object of interest or are recorded. (1) Frequency-Domain Holography (FDH). In FDH, there are 2 probes, like “object” and “reference” beams in conventional holography. Our “object” probe surrounds the light-speed object, like a fleas swarming around a sprinting animal. The object modifies the probe, imprinting information about its structure. Meanwhile, our “reference” probe co-propagates ahead of the object, free of its influence. After the interaction, object and reference combine to record a hologram. For technical reasons, our recording device is a spectrometer (a frequency-measuring device), hence the name “frequency-domain” holography. We read the hologram electronically to obtain a “snapshot” of the object’s average structure as it transits the medium. Our published work shows numerous snapshots of electron density waves (“laser wakes”) in ionized gas (“plasma”), analogous to a water wake behind a boat. Such waves are the basis of tabletop particle accelerators, in which charged particles surf on the light-speed wave, gaining energy. Comparing our snapshots to computer simulations deepens understanding of laser wakes. FDH takes snapshots of objects that are quasi-static --- i.e. like Muybridge’s horse standing still on a treadmill. If the object changes shape, FDH images blur, as when a subject moves while a camera shutter is open. Many laser-generated objects of interest do evolve as they propagate. To overcome this limit of FDH, we developed .... (2) Frequency-Domain Tomography (FDT). In FDT, 5 to 10 probe pulses are fired simultaneously across the object’s path at different angles, like a crossfire of bullets. The object imprints a “streaked” record of its evolution on each probe, which we record as in FDH, then recover a multi-frame “movie” of the object’s evolving structure using algorithms of computerized tomography. When propagation distance exceeds a few millimeters, reconstructed FDT images distort. This is because the lenses that image probes to detector have limited depth of field, like cameras that cannot focus simultaneously on both nearby and distant objects. But some laser-generated objects of interest propagate over meters. For these applications we developed … (3) Multi-Object-Plane Phase-Contrast Imaging (MOP-PCI). In MOP-PCI, we image FDT-like probes to the detector from multiple “object planes” --- like recording an event simultaneously with several cameras, some focused on nearby, others on distant, objects. To increase sensitivity, we exploit a phase-contrast imaging technique developed by Dutch Nobel laureate Fritz Zernike in the 1930s. Using MOP-PCI we recorded single-shot movies of laser pulse tracks through more than 10 cm of air. We plan to record images of meter-long tracks of electron bunches propagating through plasma in an experiment at the Stanford Linear Accelerator Center (SLAC). This will help SLAC scientists understand, optimize and scale small plasma-based particle accelerators that have applications in medicine, industry, materials science and high-energy physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The rotation of Uranus

A historical review of the use of three independent techniques for measuring the rotational rate is presented. The approaches examined are: (1) using theoretical interior models together with observations of the oblateness and the gravitational moment; (2) studying periodic fluctuations in the brightness; and (3) spectrographically measuring the Doppler shifts (line tilts). Measurements of line tilts obtained using the Kitt Peak National Observation 4 meter telescope with a Cassegrain echelle to high obtain high spectral dispersion and large image are discussed and compared with results obtained by Muench and Hipplelein (1980) and by Hayes and Belton (1977). The possibility of using speckel imaging techniques to detect the motion of features across the disc in the 6091 methane band, and with more suitable image intensifiers, in the 7261 band is considered.

Goody, R. M.↗

A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT

Background: SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Methods: Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of {sup 99m}Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Results: Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image analysis also produced a similar accuracy, sensitivity, and specificity. CFR was normal in 6, each with CAD on SCA with an overall accuracy of 91%, sensitivity of 80%, and specificity of 100%. The mean CFR was significantly lower for SCA detected abnormal than for normal patients (3.86±1.06 vs 1.94±0. 0.67, P < 0.001). Conclusions: The visually assessed image findings in static and dynamic SPECT are subjective, and may not reflect direct physiologic measures of coronary lesion based on SCA. The CFR measured with dynamic SPECT is fully objective, with better sensitivity and specificity, available only with the data generated from the dynamic SPECT method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous Sensing Error Recovery and Tomographic Inversion Using an Optimization-Based Approach

Tomography can be used to reveal internal properties of a 3D object using any penetrating wave. Advanced tomographic imaging techniques, however, are vulnerable to both systematic and random errors associated with the experimental conditions, which are often beyond the capabilities of the state-of-the-art reconstruction techniques such as regularizations. Because they can lead to reduced spatial resolution and even misinterpretation of the underlying sample structures, these errors present a fundamental obstacle to full realization of the capabilities of next-generation physical imaging. In this work, we develop efficient and explicit recovery schemes of the most common experimental error: movement of the center of rotation during the experiment. We formulate new physical models to capture the experimental setup, and we devise new mathematical optimization formulations for reliable inversion of complex samples. We demonstrate and validate the efficacy of our approach on synthetic data under known perturbations of the center of rotation.

Nonlinear optimization↗

Radiation-induced Swelling and Microcracking in SiC Cladding for LWRs

After the Fukushima accident in 2011, SiC has attracted considerable attention as a potential material for fuel cladding that can offer increased accident tolerance in light water reactors (LWRs) compared to zircaloy cladding. Existing measurements on nuclear grade SiC/SiC composites made of high-purity, stoichiometric SiC have already shown very good radiation tolerance in various harsh environments. However, there are a number of challenges that need to be addressed before SiC composites can be successfully used in LWR technologies. One of them is irradiation-induced swelling, which can lead to development of significant stresses in the matrix, followed by microcracking and subsequent release of fission products. Models of irradiation-induced swelling had been largely empirical and therefore they cannot be used to predict the microstructural dependence of microcracking. Existing models are also limited by the lack of understanding of defects that form due to irradiation in the range of temperatures relevant to fuel cladding in LWRs (<1000°C). Many of the defects in this regime of temperature are too small to be detected with traditional transmission electron microscopy (TEM) techniques. In fact the defects observed in traditional TEM account only for 10-45% of the swelling measured in irradiated SiC. Here, we developed a multi-scale simulation methodology combined with state of the art experimental imaging techniques based on aberration corrected scanning transmission electron microscopy (STEM) to provide a scientific basis for predictive models of radiation swelling and microcracking in SiC. Specifically, we have developed a phase field fracture model that predicts microcrack initiation and growth in polycrystalline SiC. The model accounts for single crystal anisotropy, including anisotropy in the elastic constants and anisotropic surface energy. It also considers the reduced fracture strength of grain boundaries. The model was implemented using the MARMOT mesoscale nuclear materials tool. We have parameterized the model for SiC using molecular dynamics simulation results. The model has been verified using single crystal, bicrystal, and polycrystal examples. Swelling model has also been developed based on cluster dynamics simulations of defect evolution in SiC. We found that point defects and small defect clusters have a significant contribution to swelling. This finding is important because point defects and very small defect clusters are not visible in experiments (e.g., in TEM). Combined modeling and experiments can bring critical insights into how swelling depends on irradiation conditions and the microstructure. In situ nanoindentation tests and ex situ nanoindentation tests were performed on assynthesized 3C-SiC and 3C-SiC irradiated under different radiation conditions. Without radiation, bend contour movement and residual bend contours after indentation demonstrate some room temperature plastic flow and residual plastic deformation. Plastic deformation recovery is also observed on unirradiated samples during unloading. Radiation-induced embrittlement is demonstrated by differences in crack geometry in in situ tests, and is consistent with ex situ test results. Failure by single, straight, cracks indicates decreased fracture toughness due to irradiation in 3C-SiC. Future work includes coupling of the swelling and fracture models and development of a master equation that can be used in the BISON code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Machine learning-based multidomain processing for texture-based image segmentation and analysis

Atomic and molecular resolved atomic force microscopy (AFM) images offer unique insights into materials' properties such as local ordering, molecular orientation, and topological defects, which can be used to pinpoint physical and chemical interactions occurring at the surface. Utilizing machine learning for extracting underlying physical parameters increases the throughput of AFM data processing and eliminates inconsistencies intrinsic to manual image analysis, thus enabling the creation of reliable frameworks for qualitative and quantitative evaluation of experimental data. Here, we present a robust and scalable approach to the segmentation of AFM images based on flexible pre-selected classification criteria. The usage of supervised learning and feature extraction allows us to retain the consideration of specific problem-dependent features (such as types of periodical structures observed in the images and the associated numerical parameters: spacing, orientation, etc.). We highlight the applicability of this approach for the segmentation of molecular resolved AFM images based on the crystal orientation of the observed domains, automated selection of boundaries, and collection of relevant statistics. Finally, we outline a general strategy for machine learning-enabled analysis of nanoscale systems exhibiting periodic order that could be applied to any analytical imaging technique

36 MATERIALS SCIENCE↗

Whole Body MRI: Non-oncological Musculoskeletal Applications

Purpose of the Review: Whole-body MRI is an emerging imaging technique on continuous evolution, used in many oncologic indications and introduced more recently in rheumatologic and systemic disorders. In this article, we review the recent musculoskeletal applications of this technique outside the field of cancer. Recent Findings: Whole-body MRI, with its high sensitivity to bone marrow and soft-tissue alterations, and ability of extensive body coverage, is progressively regarded as an effective and powerful imaging tool for the detection, staging, and monitoring under treatment of many rheumatic diseases and systemic pathologies affecting the musculoskeletal system. Disease specific imaging protocols have been designed. Summary: Whole-body MRI is an appealing, non-irradiating tool emerging in musculoskeletal imaging. It is becoming the imaging of choice in several non-oncologic indications, and its application field is on continuous expansion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging collective behavior in an rf-SQUID metamaterial tuned by DC and RF magnetic fields

In this study, we examine the collective behavior of two-dimensional nonlinear superconducting metamaterials using a non-contact spatially resolved imaging technique. The metamaterial is made up of sub-wavelength nonlinear oscillators in a strongly coupled 27x27 planar array of radio-frequency Superconducting QUantum Interference Devices (rf SQUIDs). By using low-temperature laser scanning microscopy we image microwave currents in the driven SQUIDs while in non-radiating dark modes and identify the clustering and uniformity of like-oscillating meta-atoms. We follow the rearrangement of coherent patterns due to meta-atom resonant frequency tuning as a function of external dc and rf magnetic flux bias. We find that the rf current distribution across the SQUID array at zero dc flux and small rf flux reveals a low degree of coherence. By contrast, the spatial coherence improves dramatically upon increasing of rf flux amplitude, in agreement with simulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Physiological cross-sectional area of human leg muscles based on magnetic resonance imaging

Magnetic resonance imaging techniques were used to determine the physiological cross-sectional areas (PCSAs) of the major muscles or muscle groups of the lower leg. For 12 healthy subjects, the boundaries of each muscle or muscle group were digitized from images taken at 1-cm intervals along the length of the leg. Muscle volumes were calculated from the summation of each anatomical CSA (ACSA) and the distance between each section. Muscle length was determined as the distance between the most proximal and distal images in which the muscle was visible. The PCSA of each muscle was calculated as muscle volume times the cosine of the angle of fiber pinnation divided by fiber length, where published fiber length:muscle length ratios were used to estimate fiber lengths. The mean volumes of the major plantarflexors were 489, 245, and 140 cm3 for the soleus and medial (MG) and lateral (LG) heads of the gastrocnemius. The mean PCSA of the soleus was 230 cm2, about three and eight times larger than the MG (68 cm2) and LG (28 cm2), respectively. These PCSA values were eight (soleus), four (MG), and three (LG) times larger than their respective maximum ACSA. The major dorsiflexor, the tibialis anterior (TA), had a muscle volume of 143 cm2, a PCSA of 19 cm2, and an ACSA of 9 cm2. With the exception of the soleus, the mean fiber length of all subjects was closely related to muscle volume across muscles. The soleus fibers were unusually short relative to the muscle volume, thus potentiating its force potential.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Musculoskeletal↗

From pixels to patterns: Coupling Optical Coherence Tomography and machine learning for monitoring coastal wetland root systems

Coastal wetlands are crucial in shoreline stabilization, carbon sequestration, and storm protection. Yet, due to limitations in traditional destructive sampling techniques, the belowground biomass (live root mass) and necromass (dead and decaying roots) remain difficult to assess in coastal wetlands, limiting our understanding on coastal resilience, nutrient cycling, and soil structure. This study employs Optical Coherence Tomography (OCT) as a high-resolution imaging technique to analyze root biomass and necromass in the Terrebonne Basin, Louisiana. A Random Forest (RF) model was developed to classify root health states based on OCT-derived features, achieving an accuracy of 70% in distinguishing live from dead root segments. The results demonstrate that OCT, combined with ML, offers a promising novel approach to root analysis, providing fine-scale insights into root morphology and decay patterns that are not easily captured by conventional methods. This research lays the foundation for future integration of OCT with complementary imaging modalities such as X-ray Computed Tomography (XCT) and advanced ML algorithms to enhance classification accuracy and scalability. Future work aims to expand the dataset diversity across different wetland types and apply the methodology for large-scale, repeatable assessments of root biomass turnover and accumulation, with important implications for wetland monitoring, conservation, and restoration under changing environmental conditions.

AI/ML↗

MRI of cervical cancer with a surgical perspective: staging, prognostic implications and pitfalls

Learning objectives: Magnetic resonance imaging (MRI) of the pelvis is the most reliable imaging modality for staging, treatment planning, and follow-up of cervical cancer; and its findings may now be incorporated into the International Federation of Gynecology and Obstetrics Federation (FIGO) 2018 clinical staging of cervical cancer. It is imperative that radiologists are familiar with the imaging appearance of the different stages of cervical cancer as well as the post-treatment changes and imaging pitfalls given the respective clinical manifestations, treatment regimens, and prognosis of an accurate diagnosis. In addition to the different stages of cervical cancer, we address the imaging techniques for diagnosis, staging and treatment implications as well as the changes of the new FIGO staging system. Background: The use of MRI to diagnose and stage cervical cancer is steadily increasing and the new FIGO stagi ng system, previously based on clinical examination, now allows the staging or change of staging based on the imaging findings. MRI can evaluate the extent of disease because of its excellent contrast resolution for pelvic tissues and organs, high accuracy and detailed elaboration of the cervical/uterovaginal anatomy. Content: Relevant anatomy, including normal MRI appearance of the cervix, parametria and pelvic ligaments; different stages of cervical cancer on MRI with prognostic and therapeutic implications; MRI sequences, other imaging modalities used in the staging and follow-up, treatment of different stages and the appearance of the cervix and cervical cancer post-treatment. Since clinical implications and therapeutic strategies for cervical cancer treatment vary tremendously according to degree of tumor extension, familiarity with relevant MRI techniques and findings is essential for radiologists. Summary: It is important that radiologists interpreting pelvic MRI are aware with the different stages of cervical cancer to provide useful information regarding treatment and prognosis. Pitfalls regarding the interpretation of tumor extension can interfere with an accurate diagnosis and have significant therapeutic implications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Titanium porous-transport layers for PEM water electrolysis prepared by tape casting

While the porous-transport layer (PTL) is a key component in PEM electrolyzers, it is one of the most underexplored due to limited available structures. In this work, we present a novel PTL design for PEM water electrolyzers enabled by a cost-effective, scalable tape-casting technique. Here, a precise control of the PTL pore structure is achieved by incorporating poreformers of various sizes, and by varying the titanium and poreformer ratio. The structures are characterized with SEM and synchrotron X-ray computed tomography imaging techniques. Comprehensive electrochemical performance analysis demonstrates that higher titanium loading provides improved contact at the catalyst-layer/PTL interface but suffers from severe mass-transport losses due to gas bubbles. We solve this mass-transport problem by mixing in large poreformer beads that produce a highly porous structure with excellent gas removal properties yet still maintaining mechanical integrity. The PTL fabricated with 60:40 Ti:PMMA ratio and 60 μm PMMA bead size outperformed the standard commercial Ti powder-based PTL by 62 mV at 4 A/cm 2 .

25 ENERGY STORAGE↗

Ptychography at all wavelengths

Ptychography is a computational imaging technique that operates across multiple wavelength regimes, from electron (picometres) to X-ray (~0.1 nm), extreme ultraviolet (~10 nm) and visible light (micrometres). By reconstructing both amplitude and phase from diffraction patterns, ptychography enables high-resolution, quantitative imaging without conventional limitations imposed by lens-based optics. Ptychography has enabled advances across a range of scales: achieving deep-sub-angstrom resolution with electron microscopy, becoming an indispensable tool at X-ray synchrotron facilities worldwide and overcoming the trade-offs between resolution and field-of-view in optical imaging. This Primer provides a unified treatment of ptychography across these wavelength regimes. First, we discuss theoretical foundations, reconstruction algorithms, experimental considerations and wavelength-specific challenges. We then give examples of raw and processed data from various configurations and wavelengths. Next, we highlight key applications of ptychography in life sciences, materials science and industry. We also discuss data standards, open-source software implementations and best practices for ensuring reproducibility across different wavelength regimes. Finally, we consider limitations and future opportunities for ptychography. Together with accompanying datasets and code implementations, this Primer aims to serve newcomers and experienced practitioners in the field, facilitating broader adoption of ptychography across different disciplines.

47 OTHER INSTRUMENTATION↗

Short-circuit current density imaging of crystalline silicon solar cells via lock-in thermography: Robustness and simplifications

Spatially resolved determination of solar cell parameters is beneficial for loss analysis and optimization of conversion efficiency. One key parameter that has been challenging to access by an imaging technique on solar cell level is short-circuit current density. This work discusses the robustness of a recently suggested approach to determine short-circuit current density spatially resolved based on a series of lock-in thermography images and options for a simplified image acquisition procedure. For an accurate result, one or two emissivity-corrected illuminated lock-in thermography images and one dark lock-in thermography image have to be recorded. The dark lock-in thermography image can be omitted if local shunts are negligible. Furthermore, it is shown that omitting the correction of lock-in thermography images for local emissivity variations only leads to minor distortions for standard silicon solar cells. Hence, adequate acquisition of one image only is sufficient to generate a meaningful map of short-circuit current density. Beyond that, this work illustrates the underlying physics of the recently proposed method and demonstrates its robustness concerning varying excitation conditions and locally increased series resistance. Experimentally gained short-circuit current density images are validated for monochromatic illumination in comparison to the reference method of light-beam induced current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-D-BRF-04: Experimental Investigations On Ion Radiography with Beam Scanning Using a Range Telescope

Purpose: Ion beams exhibit a finite range and an inverted depth-dose profile, the Bragg peak. These favorable properties allow superior tumordose conformality, but introduce sensitivity to range uncertainties. Hence, imaging techniques play an increasingly important role to support the treatment planning and the in-vivo monitoring of the actual ion beam treatment. Methods: This work presents the experimental investigations carried out to address the feasibility of ion transmission imaging at the Heidelberg Ion Therapy center using an active raster scanning beam delivery system and a prototype range telescope set-up based on a stack of 61 parallel-plate ionization chambers (PPIC) interleaved with 3 mm absorber plates of PMMA. Results: An extensive characterization of the set-up in terms of beam parameters and settings of the read-out electronics was performed and results will be presented. A data processing method to increase the range resolution (MIRR) of the PPIC stack was developed. In this approach, the position of the maximum of the Bragg curve is deduced from the ratio of measured signals in adjacent PPIC channels. MIRR evaluation is based on Bragg curves obtained from Monte Carlo simulations and validated with experimental data acquired with the PPIC stack using ion beams. MIRR was applied to the carbon ion radiography of an anthropomorphic Alderson head phantom yielding a resolution of 0.8 mm water equivalent thickness (WET) compared to the nominal value of 3.495 mm WET given by the thickness of the absorber slabs in the PPIC stack. An absolute comparison of the Alderson phantom carbon ion transmitted image with an X-ray digitally reconstructed radiography, both converted into WET, will also be shown. Conclusion: The obtained results are very promising and motivate further developments of the system towards an eventual clinical use.This work is supported by the German Research Foundation and the German Academic Exchange Service. This work is supported by the German Research Foundation (DFG) and the German Academic Exchange Service (DAAD)

07 ISOTOPE AND RADIATION SOURCES↗

Bridging New Observational Capabilities and Process-Level Simulation: Insights into Aerosol Roles in the Earth System

The spatial distribution of ambient aerosol particles significantly impacts aerosol–radiation–cloud interactions, which contribute to the largest uncertainty in global anthropogenic radiative forcing estimations. However, the atmospheric boundary layer and lower free troposphere have not been adequately sampled in terms of spatiotemporal resolution, hindering a comprehensive characterization of various atmospheric processes and impeding our understanding of the Earth system. To address this research data gap, we have leveraged the development of uncrewed aerial systems (UAS) and advanced measurement techniques to obtain mesoscale spatial data on aerosol microphysical and optical properties around the U.S. Southern Great Plains (SGP) atmospheric observatory. Our study also benefits from state-of-the-art laboratory facilities that include three-dimensional molecular imaging techniques enabled by secondary ion mass spectrometry and nanogram-level chemical composition analysis via micronebulization aerosol mass spectrometry. Through our study, we have developed a framework for observation–modeling integration, enabling an examination of how various assumptions about the organic–inorganic components mixing state, inferred from chemical analysis, affect clouds and radiation in observation-constrained model simulations. By integrating observational constraints (derived from offline chemical analysis of the aerosol surface using collected samples) with in situ UAS observations, we have identified a prominent role of organic-enriched nanometer layers located at the surface of aerosol particles in determining profiles of aerosol optical and hygroscopic properties over the SGP observatory. Furthermore, we have improved the agreement between predicted clouds and ground-based cloud lidar measurements. This UAS–model–laboratory integration exemplifies how these new advanced capabilities can significantly enhance our understanding of aerosol–radiation–cloud interactions.

54 ENVIRONMENTAL SCIENCES↗

The development of optical microscopy techniques for the advancement of single-particle studies

Single particle orientation and rotational tracking (SPORT) has recently become a powerful optical microscopy tool that can expose many molecular motions. Unfortunately, there is not yet a single microscopy technique that can decipher all particle motions in all environmental conditions, thus there are limitations to current technologies. Within, the two powerful microscopy tools of total internal reflection and interferometry are advanced to determine the position, orientation, and optical properties of metallic nanoparticles in a variety of environments. Total internal reflection is an optical phenomenon that has been applied to microscopy to produce either fluorescent or scattered light. The non-invasive far-field imaging technique is coupled with a near-field illumination scheme that allows for better axial resolution than confocal microscopy and epi-fluorescence microscopy. By controlling the incident illumination angle using total internal reflection fluorescence (TIRF) microscopy, a new type of imaging probe called “non-blinking” quantum dots (NBQDs) were super-localized in the axial direction to sub-10-nm precision. These particles were also used to study the rotational motion of microtubules being propelled by the motor protein kinesin across the substrate surface. The same instrument was modified to function under total internal reflection scattering (TIRS) microscopy to study metallic anisotropic nanoparticles and their dynamic interactions with synthetic lipid bilayers. Utilizing two illumination lasers with opposite polarization directions at wavelengths corresponding to the short and long axis surface plasmon resonance (SPR) of the nanoparticles, both the in-plane and out-of-plane movements of many particles could be tracked simultaneously. When combined with Gaussian point spread function (PSF) fitting for particle super-localization, the binding status and rotational movement could be resolved without degeneracy. TIRS microscopy was also used to find the 3D orientation of stationary metallic anisotropic nanoparticles utilizing only long-axis SPR enhancement. The polarization direction of the illuminating light was rotated causing the relative intensity of p-polarized and s-polarized light within the evanescent field to change. The interaction of the evanescent field with the particles is dependent on the orientation of the particle producing an intensity curve. This curve and the in-plane angle can be compared with simulations to accurately determine the 3D orientation. Differential interference contrast (DIC) microscopy is another non-invasive far-field technique based upon interferometry that does not rely on staining or other contrast enhancing techniques. In addition, high numerical aperture condensers and objectives can be used to give a very narrow depth of field allowing for the optical tomography of samples, which makes it an ideal candidate to study biological systems. DIC microscopy has also proven itself in determining the orientation of gold nanorods in both engineered environments and within cells. Many types of nanoparticles and nanostructures have been synthesized using lithographic techniques on silicon wafer substrates. Traditionally, reflective mode DIC microscopes have been developed and applied to the topographical study of reflective substrates and the imaging of chips on silicon wafers. Herein, a laser-illuminated reflected-mode DIC was developed for studying nanoparticles on reflective surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MAPPING H-BAND SCATTERED LIGHT EMISSION IN THE MYSTERIOUS SR21 TRANSITIONAL DISK

We present the first near infrared (NIR) spatially resolved images of the circumstellar transitional disk around SR21. These images were obtained with the Subaru HiCIAO camera, adaptive optics, and the polarized differential imaging technique. We resolve the disk in scattered light at H-band for stellocentric 0.''1 {<=} r {<=} 0.''6 (12 {approx}< r {approx}< 75 AU). We compare our results with previously published spatially resolved 880 {mu}m continuum Submillimeter Array images that show an inner r {approx}< 36 AU cavity in SR21. Radiative transfer models reveal that the large disk depletion factor invoked to explain SR21's sub-mm cavity cannot be 'universal' for all grain sizes. Even significantly more moderate depletions ({delta} = 0.1, 0.01 relative to an undepleted disk) than those that reproduce the sub-mm cavity ({delta} {approx} 10{sup -6}) are inconsistent with our H-band images when they are assumed to carry over to small grains, suggesting that surface grains scattering in the NIR either survive or are generated by whatever mechanism is clearing the disk midplane. In fact, the radial polarized intensity profile of our H-band observations is smooth and steeply inwardly-increasing (r {sup -3}), with no evidence of a break at the 36 AU sub-mm cavity wall. We hypothesize that this profile is dominated by an optically thin disk envelope or atmosphere component. We also discuss the compatibility of our data with the previously postulated existence of a sub-stellar companion to SR21 at r {approx} 10-20 AU, and find that we can neither exclude nor verify this scenario. This study demonstrates the power of multiwavelength imaging of transitional disks to inform modeling efforts, including the debate over precisely what physical mechanism is responsible for clearing these disks of their large midplane grains.

79 ASTRONOMY AND ASTROPHYSICS↗