At least 739 records · Page 41

Improvement program for polycarbonate capacitors

Hermetically sealed, wound, AC, polycarbonate capacitors incorporating design improvements recommended in a previous study were designed and built. A 5000 hour, 400 Hz ac life test was conducted using 384 of these capacitors to verify the adequacy of the design improvements. The improvements incorporated in the capacitors designed for this program eliminated the major cause of failure found in the preceding work, termination failure. A failure cause not present in the previous test became significant in this test with capacitors built from one lot of polycarbonate film. The samples from this lot accounted for 25 percent of the total test complement. Analyses of failed samples showed that the film had an excessive solvent content. This solvent problem was found in 37 of the total 46 failures which occurred in this test. The other nine were random failures resulting from causes such as seal leaks, foreign particles, and possibly wrinkles.

Bailey, R. R.↗

Selected reliability studies for the NERVA program

An investigation was made into certain methods of reliability analysis that are particularly suitable for complex mechanisms or systems in which there are many interactions. The methods developed were intended to assist in the design of such mechanisms, especially for analysis of failure sensitivity to parameter variations and for estimating reliability where extensive and meaningful life testing is not feasible. The system is modeled by a network of interconnected nodes. Each node is a state or mode of operation, or is an input or output node, and the branches are interactions. The network, with its probabilistic and time-dependent paths is also analyzed for reliability and failure modes by a Monte Carlo, computerized simulation of system performance.

Hoover, S. V.↗

Investigation of hollow cathode performance for 30-cm thrusters

A parametric investigation of 6.35 mm diameter mercury hollow cathodes was carried out in a bell jar. The parameters that were varied were the amount of initial emissive mix, the insert position, the emission current, the cathode temperature, the orifice diameter, and the mercury flow rate. Flow characteristic curves and performance as a function of time were obtained for the various cathodes of interest. Also presented are the results of a 3880 hr life test of a main cathode run at 15 amps emission current with no noticeable changes in keeper and collector voltages.

Mirtich, M. J.↗

Evaluation program for secondary spacecraft cells

The cycle life tests to determine the performance capabilities of packs of cells under different loads and temperature conditions are reported. Results are summarized, and the failure of 14 failed cells is analyzed. It was found that the main cause of failure was separator deterioration and migration of the negative plate material.

Harkness, J. D.↗

Investigation of a catalytic gas generator for the Space Shuttle APU

An investigation was conducted to establish the capability of a monopropellant hydrazine catalytic gas generator to meet the requirements specified for the Space Shuttle APU. Detailed analytical and experimental studies were conducted on potential problem areas including long-term nitriding effects on materials, design variables affecting catalyst life, vehicle vibration effects, and catalyst oxidation/contamination. A full-scale gas generator, designed to operate at a chamber pressure of 750 psia and a flow rate of 0.36 lbm/sec, was fabricated and subjected to three separate life test series. The objective of the first test series was to demonstrate the capability of the gas generator to successfully complete 20 simulated Space Shuttle missions in steady-state operation. The gas generator was then refurbished and subjected to a second series of tests to demonstrate the pulse-mode capability of the gas generator during 20 simulated missions. The third series of tests was conducted with a refurbished reactor to further demonstrate pulse-mode capability with a modified catalyst bed.

Emmons, D. L.↗

Systems design of long-life systems

A long-life system is defined as a system which cannot be life-tested in its operational environment. Another restriction is that preventive maintenance and repair shall be either impossible or economically disadvantageous. Examples of such systems include planetary spacecraft, communication satellites, undersea telephone cables, and nuclear power plants. The questions discussed are related to the implementation of system functions, approaches to determine the required level of system reliability, and aspects of tradeoffs between requirements and reliability.

Miles, R. F., Jr.↗

An aneroid pressure sensor for constant-level balloons

The pressure sensor for the Tropical Wind Energy conversion and Reference Level Experiment (TWERLE) is described. Key design features of the sensor are: capacitive coupling, reference at midrange, up-down counting, passive oven, storage at flight pressure and prelaunch calibration. Sensor specifications are given which are based on the production results of 440 units. Drift, as estimated from simulated life tests, is 1 mb per 6 months. The overall weight of the sensor, including thermal package, is 180 g.

Levanon, N.↗

Technological development of high energy density capacitors

A study was conducted to develop cylindrical wound metallized film capacitors rated 2 micron F 500 VDC that had energy densities greater than 0.1J/g. Polysulfone (PS) and polyvinylidene (PVF2) were selected as dielectrics. Single film PS capacitors of 0.2J/g (uncased) were made of 3.75 micron material. Single film PVF2 capacitors of 0.19J/g (uncased) were made of 6.0 micron material. Corona measurements were made at room temperature, and capacitance and dissipation factor measurements were made over the ranges 25 C to 125 C and 120 Hz to 100 kHz. Nineteen of twenty PVF2 components survived a 2500 hour dc plus ac life test. Failure analyses revealed most failures occurred at wrinkles, but some edge failures were also seen. A 0.989g case was designed. When the case was combined with the PVF2 component, a finished energy density of 0.11J/g was achieved.

Parker, R. D.↗

Room-temperature-operation visible-emission semiconductor diode lasers

There were two main approaches taken to develop shorter wavelength lasers. (1) Based on (AlGa)As and liquid-phase epitaxy, significant new results were obtained: Properties of these laser diodes (power output, spectra, and beam patterns), materials considerations, laser theory, and growth problems are discussed. The design of (AlGa)As layers is discussed from the vertical point of view, and various design curves are given. Horizontal structural requirements are also discussed. Experimental results from measurements done as a function of hydrostatic pressure are correlated with other results. (2) The first heterojunction laser structures using GaAs sub l-x P sub x and In sub y Ga sub l-y P at compositions, where the lattice constants are matched, were grown using vapor-phase growth technology and are described in detail, including experimental device results. Threshold current densities from 3,000 to 5,000 A per sq cm. and emission wavelengths from 6,520 A to 6,640 A were obtained at 77 K. The limiting factor in these devices is nonradiative recombination at the heterojunctions. Life tests on facet-coated (AlGa)As CW diodes are reported.

Ladany, I.↗

Physical properties of thin-film field emission cathodes with molybdenum cones

Field emission cathodes fabricated using thin-film techniques and electron beam microlithography are described, together with effects obtained by varying the fabrication parameters. The emission originates from the tip of molybdenum cones that are about 1.5 micron tall with a tip radius around 500 A. Such cathodes have been produced in closely packed arrays containing 100 and 5000 cones as well as singly. Maximum currents in the range 50-150 microamp per cone can be drawn. Life tests with the 100-cone arrays drawing 2 mA total emission (or 3 A per sq cm) have proceeded in excess of 7000 hr with about a 10% drop in emission current. Studies are presented of the emission characteristics and current fluctuation phenomena. It is tentatively concluded that the emission arises from only one or a few atomic sites on the cone tips.

Spindt, C. A.↗

Evaluation of commercially-available spacecraft-type heat pipes

As part of an effort to develop reliable, cost effective spacecraft thermal control heat pipes, life tests on 30 commercially available heat pipes in 10 groups of different design and material combinations were conducted. Results for seven groups were reported herein. Materials are aluminum and stainless steel, and working fluids are methanol and ammonia. The formation of noncondensible gas was observed for times exceeding 11,000 hours. The heat transport capacities of the pipes were also determined.

Kaufman, W. B.↗

Technological development of cylindrical and flat shaped high energy density capacitors

Cylindrical wound metallized film capacitors rated 2 micron F 500 VDC that had an energy density greater than 0.3 J/g, and flat flexible metallized film capacitors rated at 2 micron F 500 VDC that had an energy density greater than 0.1 J/g were developed. Polysulfone, polycarbonate, and polyvinylidene fluoride (PVF2) were investigated as dielectrics for the cylindrical units. PVF2 in 6.0 micron m thickness was employed in the final components of both types. Capacitance and dissipation factor measurements were made over the range 25 C to 100 C, and 10 Hz to 10 kHz. No pre-life-test burning was performed, and six of ten cylindrical units survived a 2500 hour AC plus DC lift test. Three of the four failures were infant mortality. All but two of the flat components survived 400 hours. Finished energy densities were 0.104 J/g at 500 V and 0.200 J/g at 700 V, the energy density being limited by the availability of thin PVF2 films.

Zelik, J. A.↗

The 1.1 micrometer and visible emission semiconductor diode lasers

In (AlGa)As, the first of three alloy systems studied, Continuous Wave (CW) operation was obtained at room temperature at a wavelength as low as 7260 A. Reliability in this system was studied in the incoherent mode. Zinc doped devices had significant degradation, whereas Ge or Ge plus Zi doped devices had none. The Al2O3 facet coatings were shown to significantly reduce facet deterioration in all types of lasers, longer wavelength units of that type having accumulated (at the time of writing) 22,000 hours with little if any degradation. A CL study of thin (AlGa)As layers revealed micro fluctuation in composition. A macro-scale fluctuation was observed by electroreflectance. An experimental and theoretical study of the effect of stripe width on the threshold current was carried out. Emission below 7000 A was obtained in VPE grown Ga(AsP) (In,Ga)P with CW operation at 10 C. Lasers and LED's were made by LPE in (InGa) (AsP). Laser thresholds of 5 kA/cm2 were obtained, while LED efficiences were on the order of 2%. Incoherent life test over 6000 hours showed no degradation.

Ladany, I.↗

Evaluation of commercially-available spacecraft-type heat pipes

As part of an effort to develop reliable, cost effective spacecraft thermal control heat pipes, Lewis Research Center of NASA is conducting life tests on 30 commercially-available heat pipes in 10 groups of different design and material combinations. Materials are aluminum and stainless steel, and working fluids are methanol and ammonia. The formation of noncondensible gas is observed for times exceeding 11,000 hours. The heat transport capacities of the pipes are also determined. Considerable gas is found in two groups of methanol pipes; one group shows no gas. One group of ammonia pipes has no observable gas. Another group has much gas. Manufacturers' processing schedules are examined for differences explaining the presence of gas. Heat transport capacity is found to be severely reduced in some pipes containing gas.

Kaufman, W. B.↗

Performance characteristics of high-conductivity channel electron multipliers

The paper describes a new type of continuous channel multiplier (CEM) fabricated from a low-resistance glass to produce a high-conductivity channel section and thereby obtain a high count-rate capability. The flat-cone cathode configuration of the CEM is specifically designed for the detection of astigmatic exit images from grazing-incidence spectrometers at the optimum angle of illumination for high detection efficiencies at XUV wavelengths. Typical operating voltages are in the range of 2500-2900 V with stable counting plateau slopes in the range 3-6% per 100-V increment. The modal gain at 2800 V was typically in the range (50-80) million. The modal gain falls off at count rates in excess of about 20,000 per sec. The detection efficiency remains essentially constant to count rates in excess of 2 million per sec. Higher detection efficiencies (better than 20%) are obtained by coating the CEM with MgF2. In life tests of coated CEMs, no measurable change in detection efficiency was measured to a total accumulated signal of 2 times 10 to the 11th power counts.

Timothy, J. G.↗

Ninth Conference on Space Simulation

The papers presented in this conference provided an international dialogue and a meaningful exchange in the simulation of space environments as well as the evolution of these technological advances into other fields. The papers represent a significant contribution to the understanding of space simulation problems and the utilization of this knowledge. The topics of the papers include; spacecraft testing; facilities and test equipment; system and subsystem test; life sciences, medicine and space; physical environmental factors; chemical environmental factors; contamination; space physics; and thermal protection.

Source record↗

Long-term storage effects-up-date

The long-term effects of storing batteries over a period of years prior to their use in a synchronous orbit application are discussed. A previous experiment is discussed where life testing was performed on cells after having stored the battery for a period of three years with the cell shorted and at a temperature on the order of 5-10 C. The test consisted of performing a sequence of 10 simulated eclipse seasons (equivalent in cycling of five years in synchronous orbit). Results of this test indicated very little degradation and change in the physical and chemical conditions of the cell. The program was extended for an additional year (battery was stored for four years) under the same conditions and testing. The results of the four year storage (one exception) indicate that no further change occurred that is significant from the three year test.

Scott, W. R.↗

Dynamics of cell degradation

The use of chemical and physical data as a supplement to linear regression models in the prediction of cell failure is discussed. Principal factors to be considered are the positive thickness and weight, and the negative thickness. A model for cell degradation and failure in accelerated life test cells is presented and predictions based on a teardown analysis are included.

Mcdermott, P. P.↗