Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

ISS Ammonia Leak Detection Through X-Ray Fluorescence

Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge coupled device) focal plane detector that reads out the position and energy of the X-rays, allowing a determination of the leak location. The effective area of the detection system is approximately 2 cm(exp2) at 1 keV. The Lobster astrophysics instrument, designed for monitoring the sky for Xray transients, gives high sensitivity along with large field of view (30×30deg) and good spatial resolution (1 arc min). This offers a significant benefit for detecting ISS ammonia leaks, since the goal is to localize small leaks as efficiently as possible.

Camp, Jordan↗

Modeling athermal phonons in novel materials using the G4CMP simulation toolkit

Understanding phonon and charge propagation in superconducting devices plays an important role in both performing low-threshold dark matter searches and limiting correlated errors in superconducting qubits. The Geant4 Condensed Matter Physics (G4CMP) package, originally developed for the Cryogenic Dark Matter Search (CDMS) experiment, models charge and phonon transport within silicon and germanium detectors and has been validated by experimental measurements of phonon caustics, mean charge-carrier drift velocities, and heat pulse propagation times. Here, in this work, we present a concise framework for expanding the capabilities for phonon transport to a number of other novel substrate materials of interest to the dark matter and quantum computing communities, including sapphire (Al 2 O 3 ), gallium arsenide (GaAs), lithium fluoride (LiF), calcium tungstate (CaWO 4 ), and calcium fluoride (CaF 2 ). We demonstrate the use of this framework in generating phonon transport properties of these materials and compare these properties with experimentally-determined values where available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searching for Hybrid Mesons with GlueX

Hybrid mesons consist of a quark-antiquark pair bound together by a gluonic field that is in an excited state. Measuring the spectrum of these states will provide valuable information on the gluonic degrees of freedom of QCD in the quark-confinement regime.A rich spectrum of hybrid meson states has been predicted, but only a few experiments have reported evidence of their existence. The GlueX experiment at Jefferson Lab is designed to search for and measure the spectrum of light-mass hybrid mesons, and it has began its physics run in Spring 2017. For the experiment, a 12 GeV electron beam incident on a diamond radiator is used to produce a linearly-polarized, coherent bremsstrahlung tagged-photon beam with a coherent peak at 9 GeV. The linearly-polarized photon beam is incident on a proton target located within the hermetic GlueX detector, which can detect many different final states to which the hybrid mesons are predicted to decay. Measurements with these initial data are discussed, including beam asymmetry measurements, the search for photoproduced Ξ baryons, and near-threshold charm production.

Dobbs, SEan↗

Symbol lock detection in the ARX 2 and Block 5 receivers

The performances of 5 symbol-lock detectors are compared. These detectors are the square-law detector with overlapping (SQOD) and nonoverlapping integrators, the absolute-value detectors with overlapping and nonoverlapping integrators, and the signal-power estimator detector (SPED). The analysis considers various scenarios in which the observation interval is much larger than or equal to the symbol-synchronizer loop bandwidth, and which were not considered in previous analyses. Also, the case of threshold setting in the absence of signal is considered. It is shown, that the SQOD outperforms all others when the threshold is set in the presence of a signal, independent of the relationship between loop bandwidth and observation period. On the other hand, the SPED outperforms all others when the threshold is set in the presence of noise only.

Shihabi, M.↗

Design and Calibration of Autonomous Coherent Doppler Lidar for Space Missions

Developed a new algorithm for the simulation of three dimensional homogeneous turbulent velocity fields. For typical atmospheric conditions it is impossible to produce a simulated velocity field that simultaneously satisfy a given spatial correlation and the corresponding spatial spectrum because of spectral aliasing. The new algorithms produce a turbulent velocity field which has accurate spatial correlations which is required for performance predictions from space-based systems. Developed a new algorithm for extracting the spatial statistics of the atmospheric velocity field using coherent Doppler lidar. The performance of the algorithm was compared with past methods and the new algorithm produces useful results for space-based data, which was not possible before. Developed new methods for verification of the errors in ground-based and space-based Doppler lidar wind measurements. These new methods do not require independent in situ data. This is an important issue for the verification of space-based Doppler lidar measurements of the global wind field. The performance of the new algorithm was compared with past results for both space-based and ground-based operation. The new algorithm has the best performance and is the only algorithm that performed satisfactory for spacebased operation. The performance of coherent Doppler lidar for a space missions with various scanning geometries was determined using computer simulation which contained the effects of random instrumental velocity errors, wind shear, wind variability along the range-gate and from shot-to-shot, and random variations in atmospheric aerosol backscatter over the measurement volume. The bias in the velocity estimates was small and the accuracy in the is typically less than 0.5 m/s for high signal conditions. For a large number of shot per velocity estimate, the threshold signal level for acceptable estimates is proportional to the number of shots to the minus one half power. This agrees with previous results determined for ground-based measurements. The use of multi-element optical detectors for autonomous operation of coherent Doppler lidar was shown to be a very promising technique. Optimal detector geometries were determined by computer simulation of performance: for ground-based testing with a fixed calibration target and for space-based operation using the random surface returns. The effects of refractive turbulence on ground-based calibration of coherent Doppler lidar was determined by computer simulations and compared with theoretical predictions. New techniques were required to correctly predict performance for the focused beam geometry commonly used for verification of space-based operation. An improved velocity estimator was evaluated for space-based applications were signal shot measurements are used to produce vector wind measurements. This permits more accurate measurements when the signal level is not known a priori or not available from multiple shot measurements. The average Doppler lidar signal spectrum including the effects of velocity turbulence was derived and calculated. This permits new estimation algorithms for turbulence based on spectral estimates. In situ atmospheric measurements were conducted and analyzed using an instrumented kite-platform. This work helps provide the required in situ data for verification of Doppler lidar velocity statistics.

Frehlich, Rod G.↗

Discrete Data Qualification System and Method Comprising Noise Series Fault Detection

A Sensor Data Qualification (SDQ) function has been developed that allows the onboard flight computers on NASA s launch vehicles to determine the validity of sensor data to ensure that critical safety and operational decisions are not based on faulty sensor data. This SDQ function includes a novel noise series fault detection algorithm for qualification of the output data from LO2 and LH2 low-level liquid sensors. These sensors are positioned in a launch vehicle s propellant tanks in order to detect propellant depletion during a rocket engine s boost operating phase. This detection capability can prevent the catastrophic situation where the engine operates without propellant. The output from each LO2 and LH2 low-level liquid sensor is a discrete valued signal that is expected to be in either of two states, depending on whether the sensor is immersed (wet) or exposed (dry). Conventional methods for sensor data qualification, such as threshold limit checking, are not effective for this type of signal due to its discrete binary-state nature. To address this data qualification challenge, a noise computation and evaluation method, also known as a noise fault detector, was developed to detect unreasonable statistical characteristics in the discrete data stream. The method operates on a time series of discrete data observations over a moving window of data points and performs a continuous examination of the resulting observation stream to identify the presence of anomalous characteristics. If the method determines the existence of anomalous results, the data from the sensor is disqualified for use by other monitoring or control functions.

Fulton, Christopher↗

The CMOS Pseudo-Thyristor: a zero-static current discriminator circuit

We report a very low power discriminator circuit for pixelized detectors, called the Pseudo-Thyristor is described in this document. It is a positive feedback topology using regular PMOS and NMOS field-effect transistors (FET's) with zero static current. When a small charge is injected into the circuit, it flips rapidly due to the positive feedback and outputs a logic transition for further digitization. Simulation shows that in a 65 nm process, it is possible to achieve a detecting threshold below 5 fC while maintain the average power consumption below 10 micro-Watts when the hit occupancy is <10% for 40 MHz operation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Triangular-barrier quantum rod photodiodes: Their fabrication and detector characteristics

We have fabricated a GaAs-based triangular-barrier photodiode, in which self-assembled InGaAs quantum rods (Q-rods) are embedded in its barrier region. Transport study at 100 K has shown that electrons start to flow mainly through Q-rods when a bias is set above a threshold. Upon illumination, photo-generated holes are found to accumulate in the middle portion of Q-rods and efficiently lower the local barrier height, yielding the responsivity as high as 10{sup 5} A/W at the incident light of 1 fW.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Search for the rare decay of the W boson into a pion and a photon in proton-proton collisions at $ \sqrt{s}$=13TeV

A search is performed for the rare decay W ± → π ± γ in proton-proton collisions at s = 13 TeV . Data corresponding to an integrated luminosity of 137 fb - 1 were collected during 2016 to 2018 with the CMS detector. This analysis exploits a novel search strategy based on W boson production in top quark pair events. An inclusive search for the W ± → π ± γ decay is not optimal at the LHC because of the high trigger thresholds. Instead, a trigger selection is exploited in which the W boson originating from one of the top quarks is used to tag the event in a leptonic decay. The W boson emerging from the other top quark is used to search for the W ± → π ± γ signature. Such decays are characterized by an isolated track pointing to a large energy deposit, and by an isolated photon of large transverse momentum. The presence of b quark jets reduces the background from the hadronization of light-flavor quarks and gluons. The W ± → π ± γ decay is not observed. An upper exclusion limit is set to this branching fraction, corresponding to 1.50 × 10 - 5 at 95% confidence level, whereas the expected upper exclusion limit is 0.85 - 0.29 + 0.52 × 10 - 5 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The hard X-ray burst spectrometer on the solar maximum mission

The primary scientific objective of the spectrometer is to provide a greater understanding of the role of energetic electrons in solar flares. This will be achieved by observations of high energy X-rays in the energy range from 20 to 200 keV with time resolution of 0.128s on a continuous basis and as short as 1 ms for limited intervals. The X-ray detector is an actively shielded CsI(Na) crystal with a thickness of 0.635 cm and a sensitive area of 71 sq cm. In the first year after launch, it is expected that approximately 1000 flares above the sensitivity threshold of 0.2 photons/(sq cm s) lasting for one second, will be detected.

Orwig, L. E.↗

Temperature Evolution of Excitonic Absorptions in Cd(1-x)Zn(x)Te Materials

The studies consist of measuring the frequency dependent transmittance (T) and reflectance (R) above and below the optical band-gap in the UV/Visible and infrared frequency ranges for Cd(l-x),Zn(x),Te materials for x=0 and x=0.04. Measurements were also done in the temperature range from 5 to 300 K. The results show that the optical gap near 1.49 eV at 300 K increases to 1.62 eV at 5 K. Finally, we observe sharp absorption peaks near this gap energy at low temperatures. The close proximity of these peaks to the optical transition threshold suggests that they originate from the creation of bound electron-hole pairs or excitons. The decay of these excitonic absorptions may contribute to a photoluminescence and transient background response of these back-illuminated HgCdTe CCD detectors.

Quijada, Manuel A.↗

CUORE: The first bolometric experiment at the ton scale for the search for neutrino-less double beta decay

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most massive bolometric experiment searching for neutrino-less double beta (0νββ) decay. The detector consists of an array of 988 TeO 2 crystals (742 kg) arranged in a compact cylindrical structure of 19 towers. Here, this paper will describe the CUORE experiment, including the cryostat, and present the detector performance during the first year of running. Additional detail will describe the effort made in improving the energy resolution in the 130 Te 0νββ decay region of interest (ROI) and the suppression of backgrounds. A description of work to lower the energy threshold in order to give CUORE the sensitivity to search for other rare events, such as dark matter, will also be provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The faint limit of the Hubble Space Telescope faint object spectrograph and rejection of the cosmic-ray background

The faintest object which can be observed with the Hubble Space Telescope (HST) Faint Object Spectrograph (FOS) is set by the detector cosmic-ray background and not by object flux. We use data from Beaver and Lyons to show that 48% of the background counts are from cosmic rays which each generate a near instantaneous burst of two or more counts. Setting the FOS threshold parameter REJLIM = 1, which rejects all frames with more than one count increases the ratio of signal-to-dark counts (S/D) by a factor of 1.94, regardless of the frame time or the object signal, because half of the dark counts which arrive in single counts (from either cosmic-ray bursts or thermal dark current photoemission) are rejected at the same rate as the object signal. But the signal-to-noise ratio (SNR proportional to S/square root of S + D) increases by at most a factor of 1.35, and for realistic parameters and taking into account dead time, we expect a gain in SNR of only 1.18. If a diode has failed and now emits noise, no data at all will be recorded. The chance of this occurring is approximately = 10% , and for this reason we do not recommend the use of REJLIM. The two-point correlation function of dark counts per pixel has strong peaks every four pixels, caused by the action of quarter-stepping on the counts from large bursts. The counts from such bursts spread over at least 80-100 diodes, and we show that such bursts can be rejected during data reduction if the data are recorded in RAPID mode with individual exposures of about 35 seconds. The SNR of the spectrum can also be improved by weighting each exposure by its SNR (a function ofthe mean dark count rate at that time), since dark varies by a factor of 2 around an orbit. These two procedures together increase the SNR by a factor of 1.1.3 (a 28% gain in exposure time) in regions of a spectrum where the object is much fainter than the background. We find that the Ly-alpha and O I sky emission lines give at most 4 (counts/array/s/sq arcsec), and typically half this number. With a small frame time and a small entrance aperture, these counts cause REJLIM = 1 to reject only a few percent of the data. We discuss only the HST FOS blue side detector, but the same ideas apply to any photon counter which records bursts of noise, and the calculations resemble those for the loss of signal due to coincidences in photon counters. In the ideal photon counter the dark counts are readily distinguished from photons. One way to do this is to add detectors which records only dark current, so that every cosmic ray produces more than one count and the instrument can be operated in an anti-coincidence mode.

Tytler, David↗

Understanding the bias introduced in quantum dot blinking using change point analysis

Quantum dots are semiconductor crystals that are less than 100 nanometers in size; that is, between 1 billionth and 100 billionths of a meter. They can be composed of one semiconductor material or a core of one semiconductor surrounded by a shell of another. The quantum dots studied in this work consisted of a cadmium selenide core surrounded by a cadmium sulfide shell. When a quantum dot is illuminated with light, some of it can be absorbed and excites the quantum dot to a higher energy state. To relax back down to its resting state, light can be emitted in the form of fluorescence. The nature of the fluorescence that is emitted from a single quantum dot differs from that which is emitted from a bulk sample (usually a solid film or a solution of quantum dots). While in bulk samples the fluorescence over time fluctuates randomly about some average, maintaining a continuous average intensity, single quantum dot fluorescence switches between two or more intensities. This phenomenon is referred to as quantum dot blinking, and its origin is of significant relevance to solar cell, light emitting diode and biological tracking applications. Quantum dot blinking can be studied by exciting an isolated quantum dot with light and recording the ensuing fluorescence using sensitive detectors. This is done over many minutes, resulting in a fluorescence intensity (in counts per second) versus time trajectory. These trajectories must be further analyzed in order to understand the nature of the blinking behavior. Conventionally, a bin and threshold analysis is used, whereby the arrival times of fluorescent photons are binned to reduce the signal noise, and a threshold is used to separate the trajectory into periods of high and low fluorescence. In this study, the effects of bin size and threshold on the blinking kinetics were investigated, and the assumption that there is only one bright and one dark state was tested. To do so, a statistically rigorous method called change point analysis was needed which does not require binning and which can determine the number of intensity levels present. Blinking in 17 quantum dots was studied using both analysis methods. The primary parameter that was compared between the two methods is called a truncation time. Increasing the bin size was found to generally lead to a larger truncation time while increasing the threshold always decreased the truncation time. Using the change point analysis method, 12 out of 17 quantum dots were found to exhibit more than two intensity levels. Lastly, the assumption that only two intensity levels exist was found to significantly affect the blinking statistics: when individual levels were combined into one bright level, the truncation time would increase. The change point analysis method was found to be more suitable for studying multilevel blinking in quantum dots than the conventional bin and threshold method, since the effects of binning and thresholding can be alleviated and the two-level assumption relaxed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dark Matter Search Results from the PICO - 60 C 3 F 8 Bubble Chamber

New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C 3 F 8 located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C 3 F 8 exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than one event per month. A blind analysis of an efficiency-corrected 1167-kg day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. In conclusion, these results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at 3.4×10 -41 cm 2 for a 30-GeV c -2 WIMP, more than 1 order of magnitude improvement from previous PICO results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and Comparison of the Light Output of Ni-doped 6LiF/ZnS for Use in Neutron Multiplicity Counting

Abstract–Alternatives to 3He for neutron detection have recently become attractive for safeguards applications. Pacific Northwest National Laboratory is developing a neutron multiplicity counter that is based on 6LiF/ZnS. Some of the properties of this material, such as the scintillation light decay time, can be tuned by doping the material with a small amount of nickel. This doping affects other properties of the material, in particular the time dependence of the scintillation light output. To determine whether the nickel-doped or undoped 6LiF/ZnS material would better suit the neutron multiplicity counter system, a series of experiments compared the use of undoped 6LiF/ZnS and a Ni-doped variant using both small samples and full-scale detectors made using the two materials. Both materials were manufactured by Eljen Technology of Sweetwater, Texas. The Ni-doped variant produced less light than the undoped material and had a shorter decay time. For all choices of detection threshold above the electronic noise, the decrease in light output did not affect the detection efficiency of the system.

Behling, Richard S.↗

Samarkand complex setup for investigation of cosmic ray variation in the energy range of 7 10 (9) - 10 (15) eV

The Samarkand complex setup is aimed at the study of cosmic ray variations in a wide energy range from 7 billion eV (which corresponds to the geomagnetic threshold in the region of Samarkand) up to approx 10 to the 15th power to 10 to the 16th power eV. The setup consists of four 6-counter sections of neutron supermonitor with counters SNM-15 and 48 scintillator detectors (1 sq m each) placed under and above the supermonitor. The effective area of the setup for recording neutrons and muons is 24 sq m. The setup can register time variations of the following cosmic ray components: (1) the total neutron counting rate, (2) counting rates for neutrons of different multiplicity, (3) soft-muon fluxes, (4) hard-muon fluxes at various zenith and azimuth angles, (5) electron-photon component, (6) extensive air showers (EAS) induced by primary particles in a wide energy range and accompanied or not accompanied by muons and neutrons.

Dorman, L. I.↗

MARIE Dose and Flux Measurements in Mars Orbit

We present results from the Martian Radiation Environment Experiment (MARIE), aboard the 2001 Mars Odyssey spacecraft in orbit around Mars. MARIE operated successfully from March 2002 through October 2003. At the time of this writing, the instrument is off due to a loss of communications during an extremely intense Solar Particle Event. Efforts to revive MARIE are planned for Spring 2004, when Odyssey's role as a communications relay for the MER rovers is completed. During the period of successful operation, MARIE returned the first detailed energetic charged particle data from Mars. Due to limitations of the instrument, normalizing MARIE data to flux or dose is not straightforward - several large corrections are needed. Thus normalized results (like dose or flux) have large uncertainties and/or significant model-dependence. The problems in normalization are mainly due to inefficiency in detecting high-energy protons (signal-to-noise problems force the trigger threshold to be higher than optimal), to the excessively high gains employed in the signal processing electronics (many ions deposit energy sufficient to saturate the electronics, and dE/dx information is lost), and to artifacts associated with the two trigger detectors (incomplete registration of dE/dx). Despite these problems, MARIE is efficient for detecting helium ions with kinetic energies above about 30 MeV/nucleon, and for detecting high-energy ions (energies above about 400 MeV/nucleon) with charges from 5 to 10. Fluxes of these heavier ions can be compared to fluxes obtained from the ACE/CRIS instrument, providing at least one area of direct comparison between data obtained at Earth and at Mars; this analysis will be presented as a work in progress. We will also present dose-rate data, with a detailed explanation of the many sources of uncertainty in normalization. The results for both flux and dose will be compared to predictions of the HZETRN model of the GCR.

Zeitlin, C.↗