Search NASA⌕ Search

SEARCH · Search NASA

Results for “high spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

In situ synthesis and macroscale alignment of CsPbBr 3 perovskite nanorods in a polymer matrix

Here, we report an in situ catalyst-free strategy to synthesize inorganic CsPbBr 3 perovskite nanorods in a polymer matrix (NRs-PM) with good dimensional control, outstanding optical properties and ultrahigh environmental stability. Polarization photoluminescence (PL) imaging with high spatial resolution was carried out for the first time on single nanorod (NR) and shows a relatively high local polarization ratio (~0.4) consistent with theoretical predictions based on a dielectric contrast model. We further demonstrate that macroscale alignment of the CsPbBr 3 nanorods can be achieved through mechanically stretching the NRs-PM films at elevated temperature, without deteriorating the optical quality of the NRs. In conclusion, a polarization ratio of 0.23 is observed for these aligned NRs-PM films, suggesting their potential as polarized down-converters to increase the light efficiency in liquid crystal display (LCD) backlights.

36 MATERIALS SCIENCE↗

Initial beam emission spectroscopy diagnostic system on HL-2A tokamak

A beam emission spectroscopy system is being developed and deployed on the HL-2A tokamak to measure local low wavenumber (k ⊥ ρ i < 1) density fluctuations by measuring the Doppler-shifted emission from a 50 kV deuterium heating neutral beam. High spatial resolution (Δr ≤ 1 cm, Δz ≤ 1.5 cm) measurements are achieved with customized in-vacuum optics. High frequency, high-gain preamplifiers sample the light intensity at a Nyquist frequency of 1 MHz and achieve a high S/N ratio via high optical throughput, low-noise preamplifiers, and high quantum efficiency photodiodes. A first set of 16 detector channels [configured in an 8 (radial) × 2 (poloidal) array] has been installed and tested at HL-2A, covering the radial range r/a = 0.8–1.1. The frequency and wavenumber spectra have been measured under different plasma conditions. Initial measurements have demonstrated the capability of measuring edge plasma density fluctuation spectra and the poloidal flow velocity fields with a high S/N ratio.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A SATELLITE AGNOSTIC APPROACH TO QUANTIFYING HAIL DAMAGE SWATHS ACROSS THE CENTRAL UNITED STATES AND OTHER AGRICULTURAL REGIONS

Intense thunderstorms can bring damaging winds and large hail to agricultural regions during the prime growing season. In certain cases, large swaths of damage from the wind and hail are left behind and visible to satellite remote sensing instruments. Often times, Earth observing optical remote sensing from low to high spatial resolutions are able to view these damaged swaths. With the large number of moderate to high-resolution instruments in orbit, these damaged areas have potential to be viewed daily. However, during the prime growing season, clouds frequently block the viewing of the land surface by these optical instruments. Space-borne synthetic aperture radar (SAR) instruments allow for the viewing of the land surface in most weather conditions, but instead measure backscatter as opposed to optical sensors measuring reflected or emitted radiation. Additionally, the number of SAR instruments with free and open data lags behind the number of optical sensors. This paper describes the development of a methodology that attempts to characterize hail damaged swaths, through independent use of multiple optical and SAR platforms. This satellite-agnostic approach will focus statistical analysis by comparing undamaged areas to suspected damaged areas by using commonly derived indices from optical instruments and SAR backscatter from multiple polarizations.

Jordan R Bell↗

High-Angular-Resolution Microbeam X-Ray Diffraction with CCD Detector

We have introduced a CCD-type two-dimensional X-ray detector for a microbeam X-ray diffraction system using synchrotron radiation, so that we can measure local reciprocal space maps (RSM) of samples rapidly. A local RSM of a strain-relaxed SiGe 004 grown on a Si (001) substrate was measured in higher-angular-resolution and faster than a conventional way. The measurement was achieved in 1 h 40 min. with the 2theta resolution of 80 murad and the spatial resolution of 1.4(h)x0.5(v) {mu}m{sup 2}. The introduction of the CCD enabled us to measure RSMs at many points in a sample, that is, the distribution of strain fields and lattice tilts can be revealed in high-angular- and high-spatial-resolution.

36 MATERIALS SCIENCE↗

Aberration-Coreected Electron Microscopy at Brookhaven National Laboratory

The last decade witnessed the rapid development and implementation of aberration correction in electron optics, realizing a more-than-70-year-old dream of aberration-free electron microscopy with a spatial resolution below one angstrom [1-9]. With sophisticated aberration correctors, modern electron microscopes now can reveal local structural information unavailable with neutrons and x-rays, such as the local arrangement of atoms, order/disorder, electronic inhomogeneity, bonding states, spin configuration, quantum confinement, and symmetry breaking [10-17]. Aberration correction through multipole-based correctors, as well as the associated improved stability in accelerating voltage, lens supplies, and goniometers in electron microscopes now enables medium-voltage (200-300kV) microscopes to achieve image resolution at or below 0.1nm. Aberration correction not only improves the instrument's spatial resolution but, equally importantly, allows larger objective lens pole-piece gaps to be employed thus realizing the potential of the instrument as a nanoscale property-measurement tool. That is, while retaining high spatial resolution, we can use various sample stages to observe the materials response under various temperature, electric- and magnetic- fields, and atmospheric environments. Such capabilities afford tremendous opportunities to tackle challenging science and technology issues in physics, chemistry, materials science, and biology. The research goal of the electron microscopy group at the Dept. of Condensed Matter Physics and Materials Science and the Center for Functional Nanomaterials, as well as the Institute for Advanced Electron Microscopy, Brookhaven National Laboratory (BNL), is to elucidate the microscopic origin of the physical- and chemical-behavior of materials, and the role of individual, or groups of atoms, especially in their native functional environments. We plan to accomplish this by developing and implementing various quantitative electron microscopy techniques in strongly correlated electron systems and nanostructured materials. As a first step, with the support of Materials Science Division, Office of Basic Energy Science, US Department of Energy, and the New York State Office of Science, Technology, and Academic Research, recently we acquired three aberration-corrected electron microscopes from the three major microscope manufacturers, i.e., JEOL, Hitachi, and FEI. The Hitachi HD2700C is equipped with a probe corrector, the FEI Titan 80-300 has an imaging corrector, while the JEOL2200MCO has both. All the correctors are of the dual-hexapole type, designed and manufactured by CEOS GmbH based on the design due to Rose and Haider [3, 18]. All these three are one-of-a-kind in the US, designed for specialized capabilities in characterizing nanoscale structure. In this chapter, we review the performance of these state-of-the art instruments and the new challenges associated with the improved spatial resolution, including the environment requirements of the laboratory that hosts these instruments. Although each instrument we describe here has its own strengths and drawbacks, it is not our intention to rank them in terms of their performance, especially their spatial resolution in imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MAGNETO-FRICTIONAL MODELING OF CORONAL NONLINEAR FORCE-FREE FIELDS. I. TESTING WITH ANALYTIC SOLUTIONS

We report our implementation of the magneto-frictional method in the Message Passing Interface Adaptive Mesh Refinement Versatile Advection Code (MPI-AMRVAC). The method aims at applications where local adaptive mesh refinement (AMR) is essential to make follow-up dynamical modeling affordable. We quantify its performance in both domain-decomposed uniform grids and block-adaptive AMR computations, using all frequently employed force-free, divergence-free, and other vector comparison metrics. As test cases, we revisit the semi-analytic solution of Low and Lou in both Cartesian and spherical geometries, along with the topologically challenging Titov–Démoulin model. We compare different combinations of spatial and temporal discretizations, and find that the fourth-order central difference with a local Lax–Friedrichs dissipation term in a single-step marching scheme is an optimal combination. The initial condition is provided by the potential field, which is the potential field source surface model in spherical geometry. Various boundary conditions are adopted, ranging from fully prescribed cases where all boundaries are assigned with the semi-analytic models, to solar-like cases where only the magnetic field at the bottom is known. Our results demonstrate that all the metrics compare favorably to previous works in both Cartesian and spherical coordinates. Cases with several AMR levels perform in accordance with their effective resolutions. The magneto-frictional method in MPI-AMRVAC allows us to model a region of interest with high spatial resolution and large field of view simultaneously, as required by observation-constrained extrapolations using vector data provided with modern instruments. The applications of the magneto-frictional method to observations are shown in an accompanying paper.

79 ASTRONOMY AND ASTROPHYSICS↗

High-resolution imaging of NGC 2346 with GSAOI/GeMS: Disentangling the planetary nebula molecular structure to understand its origin and evolution

We present high spatial resolution (≈60–90 mas) images of the molecular hydrogen emission in the planetary nebula (PN) NGC 2346. The data were acquired during the system verification of the Gemini Multi-conjugate Adaptive Optics System + Gemini South Adaptive Optics Imager. At the distance of NGC 2346, 700 pc, the physical resolution corresponds to ≈56 AU, which is slightly higher than an [N ii] image of NGC 2346 that was obtained with the Hubble Space Telescope/WFPC2. With this unprecedented resolution, for the first time we were able to study the structure of the H{sub 2} gas within the nebula in detail. We found it to be composed of knots and filaments, which at a lower resolution had appeared to be a uniform torus of material. We explain how the formation of the clumps and filaments in this PN are consistent with a mechanism in which a central hot bubble of nebular gas surrounding the central star has been depressurized, and the thermal pressure of the photoionized region drives the fragmentation of the swept-up shell.

79 ASTRONOMY AND ASTROPHYSICS↗

Image sharpening for mixed spatial and spectral resolution satellite systems

Two methods of image sharpening (reconstruction) are compared. The first, a spatial filtering technique, extrapolates edge information from a high spatial resolution panchromatic band at 10 meters and adds it to the low spatial resolution narrow spectral bands. The second method, a color normalizing technique, is based on the ability to separate image hue and brightness components in spectral data. Using both techniques, multispectral images are sharpened from 30, 50, 70, and 90 meter resolutions. Error rates are calculated for the two methods and all sharpened resolutions. The results indicate that the color normalizing method is superior to the spatial filtering technique.

Hallada, W. A.↗

An Electrochemical Gelation Method for Patterning Conductive PEDOT:PSS Hydrogels

Abstract Due to their high water content and macroscopic connectivity, hydrogels made from the conducting polymer PEDOT:PSS are a promising platform from which to fabricate a wide range of porous conductive materials that are increasingly of interest in applications as varied as bioelectronics, regenerative medicine, and energy storage. Despite the promising properties of PEDOT:PSS‐based porous materials, the ability to pattern PEDOT:PSS hydrogels is still required to enable their integration with multifunctional and multichannel electronic devices. In this work, a novel electrochemical gelation (“electrogelation”) method is presented for rapidly patterning PEDOT:PSS hydrogels on any conductive template, including curved and 3D surfaces. High spatial resolution is achieved through use of a sacrificial metal layer to generate the hydrogel pattern, thereby enabling high‐performance conducting hydrogels and aerogels with desirable material properties to be introduced into increasingly complex device architectures.

Feig, Vivian Rachel↗

Thermal neutron imaging detector with wavelength shifting fiber and digital readout

Here, we developed a large area, digital thermal neutron imaging detector. The detector uses a 6 LiF/ZnS(Ag) neutron-sensitive scintillator combined with wavelength shifting fiber technology. The signals from fiber channels are amplified, integrated, and digitized using individual analog-to-digital converters for each channel. The neutron position is determined from the digitized signal using a least-squares gaussian-fitting algorithm. The detector size was 77 × 38 cm 2 (2926 cm 2 ), it provided 1.3 mm resolution, and its resolution can further be improved. The detector was designed for a powder diffraction neutron scattering beamline and provided substantial improvement of d-space resolution compared with existing detectors. This detector may have broader applications due to its large area and high spatial resolution extended over its large area.

6LiF/ZnS(Ag) scintillator↗

Radiation sensitive area detection device and method

A radiation sensitive area detection device for use in conjunction with an X ray, ultraviolet or other radiation source is provided which comprises a phosphor containing film which releases a stored diffraction pattern image in response to incoming light or other electromagnetic wave. A light source such as a helium-neon laser, an optical fiber capable of directing light from the laser source onto the phosphor film and also capable of channelling the fluoresced light from the phosphor film to an integrating sphere which directs the light to a signal processing means including a light receiving means such as a photomultiplier tube. The signal processing means allows translation of the fluoresced light in order to detect the original pattern caused by the diffraction of the radiation by the original sample. The optical fiber is retained directly in front of the phosphor screen by a thin metal holder which moves up and down across the phosphor screen and which features a replaceable pinhole which allows easy adjustment of the resolution of the light projected onto the phosphor film. The device produces near real time images with high spatial resolution and without the distortion that accompanies prior art devices employing photomultiplier tubes. A method is also provided for carrying out radiation area detection using the device of the invention.

Carter, Daniel C.↗

Using Sounder Data to Improve Cirrus Cloud Height Estimation from Satellite Imagers

Modern polar-orbiting meteorological satellites provide both imaging and sounding observations simultaneously. Most imagers, however, do not have H2O and CO2 absorption bands and therefore struggle to accurately estimate the height of optically thin cirrus clouds. Sounders provide these needed observations, but at a spatial resolution that is too coarse to resolve many important cloud structures. This paper presents a technique to merge sounder and imager observations with the goal of maintaining the details offered by the imager’s high spatial resolution and the accuracy offered by the sounder’s spectral information. The technique involves deriving cloud temperatures from the sounder observations, interpolating the sounder temperatures to the imager pixels, and using the sounder temperatures as an additional constraint in the imager cloud height optimal estimation approach. This technique is demonstrated using collocated VIIRS and Cross-track Infrared Sounder (CrIS) observations with the impact of the sounder observations validated using coincident CALIPSO/CALIOP cloud heights These comparisons show significant improvement in the cloud heights for optically thin cirrus. The technique should be generally applicable to other imager/sounder pairs.

Sounder Data↗

Managing age-related changes in device radiation-response.

Aging effects in silicon electronics are a concern for systems with prolonged service lives that contain electronics not easily accessible for testing and replacement. Such effects are especially difficult to assess for components that must be exposed to, and function in, transient radiation environments. A methodology has been developed that utilizes electrical parametric and non-destructive laser testing techniques, charge collection microscopy, and controlled-environment storage to permit periodic reassessment of the state of health of such electronics. The use of a scanned, focused laser, charge collection microscopy technique, developed to detect the onset of change and then track these changes in charge collection efficiency with micron resolution, will be described. These results are then used to direct subsequent failure analyses using high-sensitivity, high spatial resolution materials analysis techniques, (such as Time-of-Flight SIMS), in order to identify the underlying material driver of the aging. It will be shown how the results of this methodology are used to create finite-element, charge transport, device models of age-affected devices, and how the time-dependence of the underlying material change is incorporated into the device aging model, so as to predict the future rate, and end-state, of the identified device aging process. Lastly the model is validated using wavelength-dependent charge collection microscopy measurements of the device's response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Accuracy Tidal Flat Digital Elevation Model Construction Using TanDEM-X Science Phase Data

This study explored the feasibility of using TanDEM-X (TDX) interferometric observations of tidal flats for digital elevation model (DEM) construction. Our goal was to generate high-precision DEMs in tidal flat areas, because accurate intertidal zone data are essential for monitoring coastal environment sand erosion processes. To monitor dynamic coastal changes caused by waves, currents, and tides, very accurate DEMs with high spatial resolution are required. The bi- and monostatic modes of the TDX interferometer employed during the TDX science phase provided a great opportunity for highly accurate intertidal DEM construction using radar interferometry with no time lag (bistatic mode) or an approximately 10-s temporal baseline (monostatic mode) between the master and slave synthetic aperture radar image acquisitions. In this study, DEM construction in tidal flat areas was first optimized based on the TDX system parameters used in various TDX modes. We successfully generated intertidal zone DEMs with 57-m spatial resolutions and interferometric height accuracies better than 0.15 m for three representative tidal flats on the west coast of the Korean Peninsula. Finally, we validated these TDX DEMs against real-time kinematic-GPS measurements acquired in two tidal flat areas; the correlation coefficient was 0.97 with a root mean square error of 0.20 m.

Lee, Seung-Kuk↗

Studying of multi-shell gas-puff Z-pinches using x-ray spectroscopy with spatial resolution

Dynamics and parameters of gas-puff Z-pinch plasmas at stagnation were studied using x-ray spectroscopic diagnostics. In experiments on a 1 MA pulsed power generator, multilayer coaxial loads were made using a triple-nozzle gas-puff valve. High-luminosity spectrographs with spherically bent crystals made it possible to record spectra with high spatial resolution along the pinch axis and to record two-dimensional plasma images in separate spectral lines. Using various combinations of gases in the nozzles and adding small amounts of a gas tracer, the final structure and composition of the compressed plasma were determined. Furthermore, plasma parameters were estimated by modeling the spectra using the PrismSPECT program, but with the limitation that the spectra were time-integrated, so that spectra from different gases and at different positions may have been emitted at different times.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct measurements of slip irreversibility in a nickel-based superalloy using high resolution digital image correlation

Fatigue crack nucleation in crystalline materials typically develops due to highly localized cyclic slip. During a fatigue cycle, reverse slip differs locally from slip in the forward direction particularly in precipitate-containing materials such as superalloys. In this paper we report the first direct measurements of irreversibility at the scale of individual slip bands by high-resolution digital image correlation (DIC) in a polycrystalline nickel-based superalloy. Quantitative measurements of the slip irreversibility are challenging for regions of material that have a size that captures the microstructure and its variability. High spatial resolution at the nanometer scale during experimental measurements is needed to observe slip localization during deformation. Moreover, large fields are also needed to obtain the material response over statistically representative populations of microstructural configurations. Recently, high resolution scanning electron microscope (SEM) digital image correlation (DIC) has been extended for quantitative analysis of discontinuities induced by slip events using the Heaviside-DIC method. Therefore, this novel method provides quantitative measurements of slip localization at the specimen surface. In this paper, the Heaviside-DIC method is used to measure slip irreversibility and plastic strain accumulation in a nickel-based superalloy. The method detects bands with high levels of irreversibility early in cycling that ultimately form fatigue cracks upon further cycling. The local microstructural configurations that induce large amounts of plasticity and slip irreversibility are correlated to crack nucleation locations.

36 MATERIALS SCIENCE↗

High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography

X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-power small-spot liquid-metal-jet electron-impact source. Lastly, the tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of hard X-ray imaging using monolithic active pixel sensors (MAPS)

Silicon detectors have been widely used in high energy physics (HEP) experiments. The outstanding properties of silicon detectors include radiation hardness, small material budget, fine spatial resolution, high speed and low cost. In this paper, we report initial results of using a single-bit Monolithic Active Pixel Sensor (MAPS), a leading candidate for the next generation trackers in high luminosity colliders, for hard X-ray imaging. The MAPS responses to X-ray with different energies are obtained and compared with simulation. The observed cluster sizes are larger than that predicted by the Continuous Slowing Down Approximation (CSDA) model, indicating that the charge diffusion process might play an important in the MAPS response to low energy electrons. In conclusion, this work paves the way towards multiple layer ultrafast silicon sensor applications in synchrotrons and XFEL beamlines.

36 MATERIALS SCIENCE↗