Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

In situ focus characterization by ablation technique to enable optics alignment at an XUV FEL source

In situ focus characterization is demonstrated by working at an extreme ultraviolet (XUV) free-electron laser source using ablation technique. Design of the instrument reported here allows reaching a few micrometres resolution along with keeping the ultrahigh vacuum conditions and ensures high-contrast visibility of ablative imprints on optically transparent samples, e.g., PMMA. This enables on-line monitoring of the beam profile changes and thus makes possible in situ alignment of the XUV focusing optics. A good agreement between focal characterizations retrieved from in situ inspection of ablative imprints contours and from well-established accurate ex situ analysis with Nomarski microscope has been observed for a typical micro-focus experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of techniques for advanced optical contamination measurement with internal reflection spectroscopy, phase 1, volume 1

The feasibility of monitoring volatile contaminants in a large space simulation chamber using techniques of internal reflection spectroscopy was demonstrated analytically and experimentally. The infrared spectral region was selected as the operational spectral range in order to provide unique identification of the contaminants along with sufficient sensitivity to detect trace contaminant concentrations. It was determined theoretically that a monolayer of the contaminants could be detected and identified using optimized experimental procedures. This ability was verified experimentally. Procedures were developed to correct the attenuated total reflectance spectra for thick sample distortion. However, by using two different element designs the need for such correction can be avoided.

Hayes, J. D.↗

Spectrally resolved phase-shifting interference microscopy: technique based on optical coherence tomography for profiling a transparent film on a patterned substrate

Spectrally resolved white-light phase-shifting interference microscopy has been used for measurements of the thickness profile of a transparent thin-film layer deposited upon a patterned structure exhibiting steps and discontinuities. We describe a simple technique, using an approach based on spectrally resolved optical coherence tomography, that makes it possible to obtain directly a thickness profile along a line by inverse Fourier transformation of the complex spectral interference function.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using Bit Errors To Diagnose Fiber-Optic Links

Technique for diagnosis of fiber-optic digital communication link in local-area network of computers based on measurement of bit-error rates. Variable optical attenuator inserted in optical fiber to vary power of received signal. Bit-error rate depends on ratio of peak signal power to root-mean-square noise in receiver. For optimum measurements, one selects bit-error rate between 10 to negative 8th power and 10 to negative 4th power. Greater rates result in low accuracy in determination of signal-to-noise ratios, while lesser rates require impractically long measurement times.

Bergman, L. A.↗

Demonstration of the stabilization technique for nonplanar optical resonant cavities utilizing polarization

Based on our previously developed scheme to stabilize nonplanar optical resonant cavities utilizing polarization caused by a geometric phase in electromagnetic waves traveling along a twisted path, we report an application of the technique for a cavity installed in the Accelerator Test Facility, a 1.3-GeV electron beam accelerator at KEK, in which photons are generated by laser-Compton scattering. We successfully achieved a power enhancement of 1200 with 1.4% fluctuation, which means that the optical path length of the cavity has been controlled with a precision of 14 pm under an accelerator environment. In addition, polarization switching utilizing a geometric phase of the nonplanar cavity was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Separating and combining single-mode and multimode optical beams

Techniques for combining initially separate single mode and multimode optical beams into a single "Dual Mode" fiber optic have been developed. Bi-directional propagation of two beams that are differentiated only by their mode profiles (i.e., wavefront conditions) is provided. The beams can be different wavelengths and or contain different modulation information but still share a common aperture. This method allows the use of conventional micro optics and hybrid photonic packaging techniques to produce small rugged packages suitable for use in industrial or military environments.

47 OTHER INSTRUMENTATION↗

Imaging of the magnetic field structure in megagauss plasmas by combining pulsed polarimetry with an optical Kerr effect shutter technique

Pulsed polarimetry in combination with a high speed photographic technique based on the optical Kerr effect is described. The backscatter in a pulsed polarimeter is directed through a scattering cell and photographed using an {approx}1 ps shutter, essentially freezing the intensity pattern. The image provides both the local electron density and magnetic field distributions along and transverse to the laser sightline. Submillimeter spatial resolution is possible for probing wavelengths in the visible due to the high densities and strong optical activity. Pulsed polarimetry is thereby extended to centimeter-sized plasmas with n{sub e}>10{sup 19}-10{sup 20} cm{sup -3} and B>20-100 T (MG) produced by multiterawatt, multimega-ampere electrical drivers, wire Z pinches, and liner imploded magnetized plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Elemental and layer based analysis of optical properties: A new technique applied to four MAX-phases

Here we present here a novel technique to calculate partial contributions to the optical properties by atoms, elements, and layers. Following the same methodology as the calculation of the partial density of states from the density of states, we have decomposed the optical properties into the partial optical properties. Using this technique the differences of elemental resolved optical properties as well as layer-resolved optical properties are displayed for both the 211 and 312 phases of TiSiC and TiAlC MAX-phase materials.

36 MATERIALS SCIENCE↗

Advanced flow-polishing and surface metrology of the SO56 X Ray Telescope

The surface finishing of X ray grazing incidence optics is a most demanding area of optical processing, both in terms of metrology and application of optical finishing techniques. An existing optical mirror was processed using a new removal technique that uses a jet of finely dispersed and extremely small particles that impact a surface, which under the correct conditions, produces an ultrasmooth surface, especially on aspheric curvatures. The surfaces of the SO56 mirror are tapered conical shapes that have a continuously changing radius with the primary mirror having a parabolic shape and the secondary mirror a hyperbolic shape. An optical ray trace that was conducted of a telescope used the measured parameters from the existing substrates to set up the prescription for the optical layout. The optimization indicated a wavefront performance of 0.10 A at 0.633 micron.

Source record↗

Metrology of X-ray optics utilizing shearing interferometric techniques

This paper will discuss the optical testing of extreme grazing incidence mirror systems and normal incidence high-precision mirror systems during fabrication processing of the optical substrates. The optical metrology is closely coupled with an advanced material removal process which will be discussed in terms of the optical metrology. Interferometric data will be presented of the optical surfaces. Surface roughness data will be shown and discussed.

Baker, Phillip C.↗

Sub-nanosecond laser-induced structural changes in the phase change material Ge2Sb2Te5 measured by an optical pump/x-ray probe technique

Phase-change alloys are characterized by reversible switching between amorphous and crystalline phases either by laser irradiation or by an electric programming current; the resulting changes in material properties can be used for non-volatile data storage. Switching typically occurs on nanosecond or less time scales. Considering the conflicting requirements for high-speed switching, yet long term data storage integrity, a deeper understanding of the switching processes in these materials is essential for insightful application development. Although, high-speed optical pump/probe observations have been made of reflectivity changes during the Ge{sub 2}Sb{sub 2}Te{sub 5} switching process, due to the nanosecond order time scales involved little is known about the corresponding changes in structure. In addition as the amorphous phase does not diffract, its structural analysis is not amenable to analysis by high-speed diffraction techniques. We have used synchrotron-based time-resolved x-ray absorption fine structure spectroscopy (XAFS), a technique equally suitable for amorphous and crystalline phases to elaborate details in structural changes in the phase-change process. We report on two experiments using high-speed pulsed lasers that serve as optical pumps to induced material changes followed by synchrotron produced x-ray burst that serve as a time resolved structural probe. The first experiment carried out at the Advanced Photon source focuses on changes due to heating in the amorphous phase. Our experimental results indicate that the maximum temperature reached during the re-amorphization process are less than the melting point indicated in the bulk phase diagram of Ge{sub 2}Sb{sub 2}Te{sub 5} reaching a maximum temperature of 620 C and in addition, do not share the same bond length distribution of a true melt. These findings strongly suggest the possibility of non-thermal melting. In the second experiment, we have obtained near-edge x-ray absorption data for a Ge{sub 2}Sb{sub 2}Te{sub 5} film in the process of transforming from the crystalline to the amorphous phase. This was accomplished by use of a second re-crystallizing laser in addition to the amorphous state induced fast pulsed laser. In the experiment presented here a 500 ps, 532 nm high-power pump laser was focused to a spot size of 20 {micro}m via the silica substrate onto a 50 {micro}m thick Ge{sub 2}Sb{sub 2}Te{sub 5} layer with a power density of approximately 60 mJ/cm{sup 2}; the layer was capped to prevent oxidation by air. Concentric to the laser beam, a 1 x 2.5 {micro}m x-ray pulse generated from a single electron bunch in the storage ring at Spring-8 was directed to the front side side of the sample. The relative delay of the laser with respect to the x-ray pulse was varied in steps of 500 ps in the current experiment. The presence of a 30 nm thick (ZnS){sub 0.85}(SiO{sub 2}){sub 0.15} layer above the Ge{sub 2}Sb{sub 2}Te{sub 5} layer caused the Ge{sub 2}Sb{sub 2}Te{sub 5} located below the layer spot to transform from a crystalline starting phase to an amorphous high-temperature phase and then back to a crystalline phase due to the trapped heat.

43 PARTICLE ACCELERATORS↗

Modulated FT- Raman Fiber-Optic Spectroscopy: A technique for Remotely Monitoring High-Temperature Reactions in Real-Time

A modification to a commercial FT-Raman spectrometer is presented for the elimination of thermal backgrounds in FT-Raman spectra. The modification involves the use of a mechanical chopper to modulate the CW laser, remote collection of the signal via fiber optics, and connection of a dual-phase digital signal processor lock-in amplifier between the detector and the spectrometer's collection electronics to demodulate and filter the optical signals. The resulting modulated FT-Raman fiber-optic spectrometer is capable of completely eliminating thermal backgrounds at temperatures exceeding 370 C. In addition, the signal/noise of generated Raman spectra is greater than for spectra collected with the conventional FT-Raman under identical conditions and incident laser power. This is true for both room-temperature and hot samples. The method allows collection of data using preexisting spectrometer software. The total cost of the modification (excluding fiber optics) is approximately $3000 and requires less than 2 h to implement. This is the first report of Fr-Raman spectra collected at temperatures in excess of 300 C in the absence of thermal backgrounds.

Cooper, John B.↗

Spectrophotometry of comets at optical wavelengths

Techniques for spectrophotometry of comets are discussed, and results are reviewed for line and continuum spectrophotometry of comets at optical wavelengths. The techniques considered include photographic spectroscopy and spectrophotometry, photoelectric spectrophotometry, and methods based on the use of image dissector scanners, Fourier-transform instruments, and Fabry-Perot spectrometers. Results are summarized for the study of cometary emission features due to C2, CN, CH, OH, NH, C3, NH2, O, H, CO(plus), and H2O(plus). Relative abundances of various species in comets are examined, along with continuum spectrophotometry of the nuclei, comas, and tails of comets.

Ahearn, M. F.↗

Progress of a Cross-Correlation Based Optical Strain Measurement Technique for Detecting Radial Growth on a Rotating Disk

The modern turbine engine operates in a harsh environment at high speeds and is repeatedly exposed to combined high mechanical and thermal loads. The cumulative effects of these external forces lead to high stresses and strains on the engine components, such as the rotating turbine disks, which may eventually lead to a catastrophic failure if left undetected. The operating environment makes it difficult to use conventional strain gauges, therefore, non-contact strain measurement techniques is of interest to NASA and the turbine engine community. This presentation describes one such approach; the use of cross correlation analysis to measure strain experienced by the engine turbine disk with the goal of assessing potential faults and damage.

cross-correlation↗

Nonlinear optical microscopy reveals invading endothelial cells anisotropically alter three-dimensional collagen matrices

The interactions between endothelial cells (ECs) and the extracellular matrix (ECM) are fundamental in mediating various steps of angiogenesis, including cell adhesion, migration and sprout formation. Here, we used a noninvasive and non-destructive nonlinear optical microscopy (NLOM) technique to optically image endothelial sprouting morphogenesis in three-dimensional (3D) collagen matrices. We simultaneously captured signals from collagen fibers and endothelial cells using second harmonic generation (SHG) and two-photon excited fluorescence (TPF), respectively. Dynamic 3D imaging revealed EC interactions with collagen fibers along with quantifiable alterations in collagen matrix density elicited by EC movement through and morphogenesis within the matrix. Specifically, we observed increased collagen density in the area between bifurcation points of sprouting structures and anisotropic increases in collagen density around the perimeter of lumenal structures, but not advancing sprout tips. Proteinase inhibition studies revealed membrane-associated matrix metalloproteinase were utilized for sprout advancement and lumen expansion. Rho-associated kinase (p160ROCK) inhibition demonstrated that the generation of cell tension increased collagen matrix alterations. This study followed sprouting ECs within a 3D matrix and revealed that the advancing structures recognize and significantly alter their extracellular environment at the periphery of lumens as they progress.

60 APPLIED LIFE SCIENCES↗

Comparative study of laser produced Li plasma plumes from thin film and solid target

The evolution features of lithium ions and neutrals generated by two different schemes viz. the laser-blow-off (LBO) of multicomponent LiF-C thin film and conventional laser ablation (referred here as LPP) from solid lithium have been studied using optical emission spectroscopic technique. The optical signal emitted by Li I (at 670.8 nm) and Li II (548.4 nm) was monitored as a function of laser fluence, ambient gas pressure, and distance 'z' from the target. Apart from their similarities, some interesting differences were noticed in temporal profiles of the plumes generated by LPP and LBO both in vacuum as well as in the presence of the ambient gas. A comparative analysis of experimental results indicates that the ablation mechanism and subsequent laser-plume interaction were responsible for the observed differences in LPP and LBO plumes. Expansion features of the plume are discussed in the light of two different models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical Restoration of Lead Fluoride Crystals

Due to its relatively high resistance to high radiation, lead fluoride (PbF{sub 2}) crystals are becoming an increasingly popular material of choice for electromagnetic calorimetry, such as for experiments requiring the measurement of high-energy photons in Hall A of Jefferson Lab. For our studies we irradiated the PbF{sub 2} crystals using an electron linear accelerator (LINAC) followed by exposing the crystals to blue light so as to restore the nominal optical properties. This technique of optical bleaching with blue light affords an efficient and low-cost means for reversing the deleterious effects of optical transmission loss in radiation-damaged lead fluoride crystals. Whereas earlier experiments irradiated the PbF{sub 2} samples with 1.1 and 1.3 MeV gammas from {sup 60}Co, we used pulsed beams of energetic electrons from the tunable 25-MeV LINAC at Idaho Accelerator Center of Idaho State University in Pocatello, Idaho. A 20-MeV beam of electrons was targeted onto four separate 19 cm length samples of lead fluoride over periods of 1, 2, and 4 hours yielding doses between 7 kGy and 35 kGy. Samples were then bleached with blue light of wavelength 410-450 nm for periods between 19.5 and 24 hours. We performed this process twice - radiation, bleaching, radiation, and then followed by bleaching again - for each of these four PbF{sub 2} samples. We shall discuss the efficacy of blue light curing on samples that have undergone two cycles of electron irradiation and optical bleaching.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗