Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

A high speed sequential decoder

The performance and theory of operation for the High Speed Hard Decision Sequential Decoder are delineated. The decoder is a forward error correction system which is capable of accepting data from binary-phase-shift-keyed and quadriphase-shift-keyed modems at input data rates up to 30 megabits per second. Test results show that the decoder is capable of maintaining a composite error rate of 0.00001 at an input E sub b/N sub o of 5.6 db. This performance has been obtained with minimum circuit complexity.

Lum, H., Jr.↗

Segmented mirror coarse phasing with a dispersed fringe sensor: experiments on NGST's wavefront control testbed

A piston sensing and control algorithm for the segmented mirror coarse phasing using a dispersed fringe sensor (DFS) has been developed for Next Generation Space Telescope (NGST) wavefront sensing and control. The DFS can detect residual piston errors as large as order of a depth-of-focus and can phase the segment mirrors with an accuracy less than 0.1 micron, which is within the capture range of the fine phasing for NGST. A series of experiments has been carried out on the NGST's Wavefront Control Testbed (WCT) to validate the modeling results, evaluate the DFS performance, and systematically explore the factors that affect the DFS performance. This paper reports the testbed results for several critical issues of DFS performance, including DFS dynamic range, accuracy, fringe visibility, and the effects of segment mirror aberrations.

Space↗

Advantages of estimating rate corrections during dynamic propagation of spacecraft rates: Applications to real-time attitude determination of SAMPEX

This paper describes real-time attitude determination results for the Solar, Anomalous, and Magnetospheric Particle Explorer (SAMPEX), a gyroless spacecraft, using a Kalman filter/Euler equation approach denoted the real-time sequential filter (RTSF). The RTSF is an extended Kalman filter whose state vector includes the attitude quaternion and corrections to the rates, which are modeled as Markov processes with small time constants. The rate corrections impart a significant robustness to the RTSF against errors in modeling the environmental and control torques, as well as errors in the initial attitude and rates, while maintaining a small state vector. SAMPLEX flight data from various mission phases are used to demonstrate the robustness of the RTSF against a priori attitude and rate errors of up to 90 deg and 0.5 deg/sec, respectively, as well as a sensitivity of 0.0003 deg/sec in estimating rate corrections in torque computations. In contrast, it is shown that the RTSF attitude estimates without the rate corrections can degrade rapidly. RTSF advantages over single-frame attitude determination algorithms are also demonstrated through (1) substantial improvements in attitude solutions during sun-magnetic field coalignment and (2) magnetic-field-only attitude and rate estimation during the spacecraft's sun-acquisition mode. A robust magnetometer-only attitude-and-rate determination method is also developed to provide for the contingency when both sun data as well as a priori knowledge of the spacecraft state are unavailable. This method includes a deterministic algorithm used to initialize the RTSF with coarse estimates of the spacecraft attitude and rates. The combined algorithm has been found effective, yielding accuracies of 1.5 deg in attitude and 0.01 deg/sec in the rates and convergence times as little as 400 sec.

Challa, M. S.↗

Digital Filters for Digital Phase-locked Loops

An s/z hybrid model for a general phase locked loop is proposed. The impact of the loop filter on the stability, gain margin, noise equivalent bandwidth, steady state error and time response is investigated. A specific digital filter is selected which maximizes the overall gain margin of the loop. This filter can have any desired number of integrators. Three integrators are sufficient in order to track a phase jerk with zero steady state error at loop update instants. This filter has one zero near z = 1.0 for each integrator. The total number of poles of the filter is equal to the number of integrators plus two.

Simon, M.↗

Assessment of Governing Heat and Mass Transfer Coefficients for Cryogenic No-Vent Top-Off Modeling

No-vent fill / no-vent top-off (NVF/NVTO) is a method to enable the trans-fer of cryogenic propellants without the need to vent. Transferring propellants inmicrogravity environments is necessary to support the long-duration space missionsplanned for the coming decades. A key developmental milestone to developing thiscapability fully is the simulation and experimentation of NVF/NVTO in 1-g settings.This work seeks to advance the former by assessing the effectiveness of different heattransfer correlations used in a 1-g non-equilibrium model. Heat transfer correlationsfor natural convection and two-phase boiling heat transfer are compared against ex-perimental results for 34 different tests. Two distinct experiments, comprised of 21tests, are presented in detail here. These tests cover a variety of different injectionmethods, receiver tank geometries, receiver tank materials, cryogenic propellants, andinitial tank states. Overall for the cases tested in this work, the model was able topredict the pressure response within the receiver tank to a mean absolute percentageerror of 25.9%. The temperature response error rate was 29.5% and 24.9% for wall-gasand two-phase nodes, respectively. Compared to the worst case correlation set tested,the pressure prediction error rate represents a 31% improvement. For the cases pre-sented in this work, the mean pressure prediction error rate was 15.5%. Future workcould evaluate the effectiveness of this model against experiments conducted withdifferent propellants or different initial conditions. In its current form, however, themodel can still be used to help reduce design and testing time for 1-g experiments,enabling the quicker iteration that is necessary to meet the technological demands offuture space missions.

No-Vent Top Off↗

Three Dimensional Atmospheric Radiative Transfer-Applications and Methods Comparison

We review applications of 3D radiative transfer in the atmosphere, emphasizing the wide spectrum of scales important to remote sensing and modeling of cloud fields, and the characteristic scales introduced into observed radiances and fluxes by the distribution of photon pathlengths at conservative and absorbing wavelengths. We define the "plane-parallel bias", which is a measure of the importance of 3D cloud structure in large-scale models, and the "independent pixel errors" that quantify the significance of 3D effects in remote sensing, and emphasize their relative magnitude and scale dependence. A variety of approaches in current use in 3D radiative transfer, and issues of speed, accuracy, and flexibility are summarized. We also describe a recently initiated "International Intercomparison of 3-Dimensional Radiation Codes", or I3RC. I3RC is a 3-phase effort that has as its goals to: (1) understand the errors and limits of 3D methods; (2) provide "baseline" cases for future 3D code development; (3) promote sharing of 3D tools; (4) derive guidelines for 3D tool selection; and (5) improve atmospheric science education in 3D radiative transfer. Selected results from Phases 1 and 2 of I3RC are discussed. These are taken from five cloud fields: a 1D field of bar clouds, a 2D radar-derived field, a 3D Landsat-derived field, a stratiform cloud from the model of C. Moeng, and a convective cloud from the model of B. Stevens. Computations have been carried out for three monochromatic wavelengths (one conservative, one absorptive, and one thermal) and two solar zenith angles (0, 60 degrees).

Cahalan, Robert F.↗

Measurement and interpretation of crustal deformation rates associated with postglacial rebound

Analysis of Global Positioning System (GPS) data from two sites separated by horizontal distance of only approximately 2.2 m yielded phase residuals exhibiting a systematic elevation angle dependence. One of the two GPS antennas was mounted on an approximately 1 m high concrete pillar, and the other was mounted on a standard wooden tripod. We performed elevation angle cutoff tests with these data, and established that the vertical coordinate of site position was sensitive to the minimum elevation angle (elevation cutoff) of the data analyzed. For example, the vertical coordinate of site position changed by 9.7 plus or minus 0.8 mm when the minimum elevation angle was increased from 10 to 25. We performed simulations based on a simple (ray tracing) multipath model with a single horizontal reflector, and demonstrated that the elevation angle cutoff test results and the pattern of the residual versus elevation angle could be qualitatively reproduced if the reflector were located 0.1-0.2 m beneath the antenna phase center. We therefore, hypothesized that the source of the elevation-angle-dependent error were multipath reflections and scattering and that the horizontal surface of the pillar, located a distance of approximately 0.2 m beneath the antenna phase center, was the primary reflector. We tested this hypothesis by placing microwave absorbing material between the antenna and the pillar in a number of configurations and analyzed the changes in apparent position of the antenna. The results indicate that (1) the horizontal surface of the pillar is indeed the main reflector, (2) both the concrete and the metal plate embedded in the pillar are significant reflectors, and (3) the reflection can be reduced to a great degree by the use of microwave absorbing materials. These results have significant implications for the accuracy of global GPS geodetic tracking networks which use pillar-antenna configuration identical or similar to the one used here (at the Westford WFRD GPS site).

Davis, James L.↗

Pulse Shaped 8-PSK Bandwidth Efficiency and Spectral Spike Elimination

The most bandwidth-efficient communication methods are imperative to cope with the congested frequency bands. Pulse shaping methods have excellent effects on narrowing bandwidth and increasing band utilization. The position of the baseband filters for the pulse shaping is crucial. Post-modulation pulse shaping (a low pass filter is located after the modulator) can change signals from constant envelope to non-constant envelope, and non-constant envelope signals through non-linear device (a SSPA or TWT) can further spread the power spectra. Pre-modulation pulse shaping (a filter is located before the modulator) will have constant envelope. These two pulse shaping methods have different effects on narrowing the bandwidth and producing bit errors. This report studied the effect of various pre-modulation pulse shaping filters with respect to bandwidth, spectral spikes and bit error rate. A pre-modulation pulse shaped 8-ary Phase Shift Keying (8PSK) modulation was used throughout the simulations. In addition to traditional pulse shaping filters, such as Bessel, Butterworth and Square Root Raised Cosine (SRRC), other kinds of filters or pulse waveforms were also studied in the pre-modulation pulse shaping method. Simulations were conducted by using the Signal Processing Worksystem (SPW) software package on HP workstations which simulated the power spectral density of pulse shaped 8-PSK signals, end to end system performance and bit error rates (BERS) as a function of Eb/No using pulse shaping in an AWGN channel. These results are compared with the post-modulation pulse shaped 8-PSK results. The simulations indicate traditional pulse shaping filters used in pre-modulation pulse shaping may produce narrower bandwidth, but with worse BER than those in post-modulation pulse shaping. Theory and simulations show pre- modulation pulse shaping could also produce discrete line power spectra (spikes) at regular frequency intervals. These spikes may cause interference with adjacent channel and reduce power efficiency. Some particular pulses (filters), such as trapezoid and pulses with different transits (such as weighted raised cosine transit) were found to reduce bandwidth and not generate spectral spikes. Although a solid state power amplifier (SSPA) was simulated in the non-linear (saturation) region, output power spectra did not spread due to the constant envelope 8-PSK signals.

Tao, Jian-Ping↗

Baseband signal combiner for large aperture antenna array

The invention provides a means whereby the baseband output signals of all but one of the receivers associated with each of the antennas are summed and used as a correlation reference for the baseband signal not contained in the summed signal, thereby providing a plurality of correlation or alignment loops, each having an output signal related to the phase difference between its input baseband signal and the summed signal. The invention further provides a means for subtracting an output or error signal generated in one of the correlation loops whose baseband signal has a predetermined phase delay from all the other alignment loops, thereby avoiding interaction and reflection effects in the signal combiner. A variable phase delay means for each of the other baseband signals is controlled by its corresponding correlation loop.

Easterling, M. E.↗

Phase closure with a rotational shear interferometer

A simple and efficient way is proposed for achieving phase closure in an optical telescope (to enable recovering Fourier transform phases that would otherwise be corrupted by atmospheric and instrumental errors), by means of rotational shear interferometry. In a rotational shear interferometer, one images the telescope aperture onto the interferometer and then interferes the aperture with itself in a rotated orientation. To achieve the maximum frequency content permitted by the telescope, the shear has to be 180 deg, but better dynamic range and SNR are possible for lower frequencies. Drawbacks of the proposed method compared to radio astronomy are noted, and different approaches are indicated as to how to collect and use the phase closure data. Phase closure can be realized on existing telescopes and existing interferometers with special modifications. Although not all base lines are possible, the extra constraints provided by the closure phases greatly reduce the ambiguity now existing in phaseless image reconstruction.

Ribak, Erez↗

Inference of Ice Cloud Properties from High-spectral Resolution Infrared Observations

The theoretical basis is explored for inferring the microphysical properties of ice crystal from high-spectral resolution infrared observations. A radiative transfer model is employed to simulate spectral radiances to address relevant issues. The extinction and absorption efficiencies of individual ice crystals, assumed as hexagonal columns for large particles and droxtals for small particles, are computed from a combination of the finite- difference time-domain (FDTD) technique and a composite method. The corresponding phase functions are computed from a combination of FDTD and an improved geometric optics method (IGOM). Bulk scattering properties are derived by averaging the single- scattering properties of individual particles for 30 particle size distributions developed from in situ measurements and for additional four analytical Gamma size distributions for small particles. The non-sphericity of ice crystals is shown to have a significant impact on the radiative signatures in the infrared (IR) spectrum; the spherical particle approximation for inferring ice cloud properties may result in an overest&ation of the optical thickness and an inaccurate retrieval of effective particle size. Furthermore, we show that the error associated with the use of the Henyey-Greenstein phase function can be as larger as 1 K in terms of brightness temperature for larger particle effective size at some strong scattering wavenumbers. For small particles, the difference between the two phase functions is much less, with brightness temperatures generally differing by less than 0.4 K. The simulations undertaken in this study show that the slope of the IR brightness temperature spectrum between 790-960/cm is sensitive to the effective particle size. Furthermore, a strong sensitivity of IR brightness temperature to cloud optical thickness is noted within the l050-1250/cm region. Based on this spectral feature, a technique is presented for the simultaneous retrieval of the visible optical thickness and effective particle size from high spectral resolution infrared data under ice cloudy con&tion. The error analysis shows that the uncertainty of the retrieved optical thickness and effective particle size has a small range of variation. The error for retrieving particle size in conjunction with an uncertainty of 5 K in cloud'temperature, or a surface temperature uncertainty of 2.5 K, is less than 15%. The corresponding e m r in the uncertainty of optical thickness is within 5-2096, depending on the value of cloud optical thickness. The applicability of the technique is demonstrated using the aircraft-based High- resolution Interferometer Sounder (HIS) data from the Subsonic Aircraft: Contrail and Cloud Effects Special Study (SUCCESS) in 1996 and the First ISCCP Regional Experiment - Arctic Clouds Experiment (FIRE-ACE) in 1998.

Huang, Hung-Lung↗

Non-planar tests using the wind tunnel free-flight technique.

Results from the first bi-planar wind tunnel free-flight test program designed to investigate the difference between planar and nonplanar dynamic stability are presented. The test provides perhaps the best free-flight angular documentation of arbitrary nonplanar motion yet obtained. Two widely different configurations, a blunt 60-deg cone and a sharp 10-deg half-angle cone, were tested. Comparisons between the angular motion from raw data and the analytical fits indicate a phasing difference. An examination of possible causes discounts experimental errors as an explanation and points strongly toward an inadequacy of the theoretical force model.

Jaffe, P.↗

Frequency selection and calibration of a water vapor radiometer

The calibration coefficients of existing water vapor radiometers are dependent upon meteorology profiles. This is shown to be due mainly to incorrect frequency pairs. By properly selecting an optimum frequency pair, the dependency can be reduced to a relatively small amount which can be handily adjusted by surface measurement alone. Hence, a universal calibration equation is applicable to all environmental conditions - site, seasonal and diurnal variations. Optimum frequency pairs are systematically searched. Error analysis indicates that calibration for the water vapor phase delay accurate to less than 2 cm is possible at all elevation angles greater than 15 degrees.

Wu, S. C.↗

Some aspects of stratospheric chemical response to solar particle precipitations. I - Potential roles of N2/A3Sigma/ and ion-chemistry

Large amounts of long lived N2(A3Sigma) are created by the energy degradation of precipitating solar particles. Laboratory data suggest that in the stratosphere N2(A3Sigma) are efficiently converted into N2O. Through reactions with O(1D), N2O may gradually release NO and thereby influence the long term aspects of stratospheric chemical response. During the daytime, negative ions may transform an active NO(x) into an inactive HNO3. At night both negative and positive ion chemistry generate HO(x). Omission of ionic chemistry results in considerable underestimation of O3 depletion during the initial phases of solar particle events, and thereby introduces significant error in the estimation of the nature of the prompt response.

Prasad, S. S.↗

A comparison of head and manual control for a position-control pursuit tracking task

Head control was compared with manual control in a pursuit tracking task involving proportional controlled-element dynamics. An integrated control/display system was used to explore tracking effectiveness in horizontal and vertical axes tracked singly and concurrently. Compared with manual tracking, head tracking resulted in a 50 percent greater rms error score, lower pilot gain, greater high-frequency phase lag and greater low-frequency remnant. These differences were statistically significant, but differences between horizontal- and vertical-axis tracking and between 1- and 2-axis tracking were generally small and not highly significant. Manual tracking results were matched with the optimal control model using pilot-related parameters typical of those found in previous manual control studies. Head tracking performance was predicted with good accuracy using the manual tracking model plus a model for head/neck response dynamics obtained from the literature.

Levison, W. H.↗

On the adequacy of the fixed locations of the surface-based international network for inferring interannual ozone variability

The influence of the geographical distribution and the number of the surface stations in the ozone detecting network on changes in global ozone inferred from the surface measurements is investigated by comparison with information obtained from satellite backscattered UV observations on the Nimbus 4 with nearly complete global coverage for the period 1970-1972. Results show that the geographical distribution of the stations does not properly represent different latitudes. While the number of stations in the north temperate zone appears adequate to represent monthly ozone averages to within 0.5% except during the early phase of the Northern Hemisphere spring maximum, the resultant error in the derived change in north temperature zone ozone between 1970-1972 is 0.5%. In the tropical and south temperate zones the smaller number of stations reduces precision, and the ozone averages for use in deriving seasonal variability and trends are uncertain by about 1%. However, in the south temperature zone, the average from the sample may differ as much as 5% in some months from the averages derived from the full set. It is concluded that the resulting uncertainty in the global averages is comparable in size to typical yearly changes.

Heath, D. F.↗

Near-field Testing of the 15-meter Model of the Hoop Column Antenna

The technical results from near-field testing of the 15-meter model of the hoop column antenna at the Martin Marietta Denver Aerospace facility are documented. The antenna consists of a deployable central column and a 15 meter hoop, stiffened by cables into a structure with a high tolerance repeatable surface and offset feed location. The surface has been configured to have four offset parabolic apertures, each about 6 meters in diameter, and is made of gold plated molybdenum wire mesh. Pattern measurements were made with feed systems radiating at frequencies of 7.73, 11.60, 2.27, 2.225, and 4.26 (all in GHz). This report (Volume 1) covers the testing from an overall viewpoint and contains information of generalized interest for testing large antennas. This volume discusses the deployment of the antenna in the Martin Facility and the measurements to determine mechanical stability and trueness of the reflector surface, gives the test program outline, and gives a synopsis of antenna electromagnetic performance. Three techniques for measuring surface mechanical tolerances were used (theodolites, metric cameras, and near-field phase), but only the near-field phase approach is included. The report also includes an error analysis. A detailed listing of the antenna patterns are provided for the 2.225 Ghz feed in Volume 3 of this report, and for all other feeds in Volume 2.

Hoover, J.↗