Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Fast six-channel pyrometer for warm-dense-matter experiments with intense heavy-ion beams

This paper describes a fast multi-channel radiation pyrometer that was developed for warmdense-matter experiments with intense heavy ion beams at Gesellschaft fur Schwerionenforschung mbH (GSI). The pyrometer is capable of measuring of brightness temperatures from 2000 K to 50000 K, at 6 wavelengths in visible and near-infrared parts of spectrum, with 5 nanosecond temporal resolution and several micrometers spatial resolution. The pyrometer's spectral discrimination technique is based on interference filters, which act as filters and mirrors to allow for simultaneous spectral discrimination of the same ray at multiple wavelengths.

02 PETROLEUM↗

ON THE ANALATICAL SOLUTIONS AND NUMERICAL VERIFICATIONS OF THE TWO-PHASE WATER FAUCET PROBLEM

The two-phase water faucet problem is one of the benchmark problems originally proposed by Ransom. The test consists of a vertical pipe, which is initially filled with a uniform column of liquid moving with an initial velocity and an annulus of gas sitting still. At the top boundary, liquid is supplied at the same velocity as the initial velocity, and the bottom of the pipe opens to the ambient. Due to the gravity effect, the liquid column accelerates and becomes thinner. With simplifications, such as massless gas phase and no wall and interfacial frictions, an analytical solution could be obtained for the transient liquid velocity and void fraction distribution. The test has been widely used for the purposes of code assessment, benchmark and numerical verifications. This exact solution was used in this work to verify the numerical accuracy of a high-resolution spatial discretization scheme. The high-resolution spatial discretization scheme is based on the commonly used staggered grid mesh, and slope limiter was introduced to achieve high resolutions in space. It was found that, at the steady state, an expected second-order spatial accuracy could not be achieved. A further investigation showed that this exact solution does not actually satisfy the commonly used two-fluid single pressure two-phase flow equations. More importantly, we have also found that a steady-state exact solution could be obtained for the water faucet problem. In this work, we have demonstrated the derivation of the steady-state exact solution for the water faucet problem. The exact solution was then used to verify a first-order and a high-resolution spatial discretization scheme, from which expected order of accuracy was achieved by doing mesh refinement.

42 ENGINEERING↗

Numerical case study of the aerosol–cloud interactions in warm boundary layer clouds over the eastern North Atlantic with an interactive chemistry module

The presence of warm boundary layer stratiform clouds over the eastern North Atlantic (ENA) region is commonly influenced by the Azores High, especially during the summer season. To investigate comprehensive aerosol–cloud interactions, this study employs the Weather Research and Forecasting model coupled with a chemistry component (WRF-Chem), incorporating aerosol chemical components that are relevant to the formation of cloud condensation nuclei (CCN) and accounting for aerosol spatiotemporal variation. This study focuses on aerosol indirect effects, particularly the long-range transport of aerosols, in the ENA region under three different weather regimes: a ridge with a surface high-pressure system, a post-trough with a surface high-pressure system, and a weak trough. The WRF-Chem simulations conducted at a near-large-eddy scale offer valuable insights into the model's performance, especially in terms of its ability to use high spatial resolution to capture mesoscale cloud features across various weather regimes. Our result shows that introducing 5 times more aerosols to either non-precipitating or precipitating clouds significantly increases ambient CCN numbers, resulting in, to varying degrees, higher liquid water path (LWP) values. The substantial aerosol–cloud interaction especially occurs in the precipitating clouds and demonstrates the susceptibility of the LWP to changes in CCN under different regimes. Conversely, thin, non-rain clouds at the edges of a cloud system are prone to evaporation, exhibiting an aerosol drying effect. The aerosols released during this process transition back to the accumulation mode, facilitating future activation. This dynamic behavior is not adequately represented in prescribed-aerosol simulations.

54 ENVIRONMENTAL SCIENCES↗

Experimental Study of an Easily Controlled Ultra-High-Resolution Pixel-Matched Parallel-Hole Collimator with a Small Cadmium Zinc Telluride Pixelated Gamma Camera System

The aim of this study was to develop an easily controlled, ultra-high-resolution, tungsten parallel-hole collimator based on a small pixelated gamma camera system. A small cadmium zinc telluride (CZT) pixelated semiconductor detector (eValuator-2500 detector [eV product, Saxonburg, PA]) was evaluated. This detector is composed of an array of 51.2 × 0.8 × 3-mm{sup 3} individual CZT crystal elements. The ultra-high-resolution, pixel-matched, parallel-hole collimators consisted of six layers, with the same between the hole and pixel size. The basic characteristics of the imaging system, such as sensitivity and spatial resolution, was measured using a {sup 57}Co point source. The measured averages of sensitivity and spatial resolution varied depending on the septal heights of the ultra-high-resolution parallel-hole collimator and source-to-collimator distances. When the 30-mm septal height was at 1-cm source-to-collimator distance, the spatial resolution was approximately 0.85 mm. Using 5-mm septal height, over 0.3 cps/kBq sensitivity was achieved. One advantage of our system is the use of stacked collimators that can select the best combination of system sensitivity and spatial resolution. Our results demonstrated that the developed CZT–pixelated gamma camera system using an ultra-high-resolution parallel-hole collimator of various collimator geometric designs has potential as an effective instrument.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Operational Land Imager (OLI) and the Thermal Infrared Sensor (TIRS) on the Landsat Data Continuity Mission (LDCM)

The Landsat Data Continuity Mission (LDCM), a joint NASA and United States Geological Survey (USGS) mission, is scheduled for launch in December, 2012. The LDCM instrument payload will consist of the Operational Land Imager (OLI), provided by Ball Aerospace and Technology Corporation (BATC) under contract to NASA and the Thermal Infrared Sensor (TIRS), provided by NASA's Goddard Space Flight Center (GSFC). This paper will describe the design, capabilities and status of the OLI and TIRS instruments. The OLI will provide 8 channel multispectral images at a spatial resolution of 30 meters and panchromatic images at 15 meter spatial resolution. The TIRS is a 100 meter spatial resolution push-broom imager whose two spectral channels, centered at 10.8 and 12 microns, split the ETM+ thermal bands. The two channels allow the use of the "split-window" technique to aid in atmospheric correction. The TIRS focal plane consists of three Quantum Well Infrared Photodetector (QWIP) arrays to span the 185 km swath width. The OLI and TIRS instruments will be operated independently but in concert with each other. Data from both instruments will be merged into a single data stream at the (USGS)/Earth Resources Observation and Science (EROS) facility. The ground system, being developed by USGS, includes an Image Assessment System (lAS), similar to Landsat-7's, to operationally monitor, characterize and update the calibrations of the two sensors.

Reuter, Dennis↗

SU-G-IeP3-10: Molecular Imaging with Clinical X-Ray Sources and Compton Cameras

Purpose: The application of Compton cameras (CC) is a novel approach translating XFCT to a practical modality realized with clinical CT systems without the restriction of pencil beams. The dual modality design offers additional information without extra patient dose. The purpose of this work is to investigate the feasibility and efficacy of using CCs for volumetric x-ray fluorescence (XF) imaging by Monte Carlo (MC) simulations and statistical image reconstruction. Methods: The feasibility of a CC for imaging x-ray fluorescence emitted from targeted lesions is examined by MC simulations. 3 mm diameter water spheres with various gold concentrations and detector distances are placed inside the lung of an adult human phantom (MIRD) and are irradiated with both fan and cone-beam geometries. A sandwich design CC composed of Silicon and CdTe is used to image the gold nanoparticle distribution. The detection system comprises four 16×26 cm{sup 2} detector panels placed on the chest of a MIRD phantom. Constraints of energy-, spatial-resolution, clinical geometries and Doppler broadening are taken into account. Image reconstruction is performed with a list-mode MLEM algorithm with cone-projector on a GPU. Results: The comparison of reconstruction of cone- and fan-beam excitation shows that the spatial resolution is improved by 23% for fan-beams with significantly decreased processing time. Cone-beam excitation increases scatter content disturbing quantification of lesions near the body surface. Spatial resolution and detectability limit in the center of the lung is 8.7 mm and 20 fM for 50 nm diameter gold nanoparticles at 20 mGy. Conclusion: The implementation of XFCT with a CC is a feasible method for molecular imaging with high atomic number probes. Given constrains of detector resolutions, Doppler broadening, and limited exposure dose, spatial resolutions comparable with PET and molecular sensitivities in the fM range are realizable with current detector technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation into image quality and dose for different patient geometries with multiple cone-beam CT systems

Purpose: To provide quantitative and qualitative image quality metrics and imaging dose for modern Varian On-board Imager (OBI) (ver. 1.5) and Elekta X-ray Volume Imager (XVI) (ver. 4.5R) cone-beam computed tomography (CBCT) systems in a clinical adaptive radiation therapy environment by accounting for varying patient thickness. Methods: Image quality measurements were acquired with Catphan 504 phantom (nominal diameter and with additional 10 cm thickness) for OBI and XVI systems and compared to planning CT (pCT) (GE LightSpeed). Various clinical protocols were analyzed for the OBI and XVI systems and analyzed using image quality metrics, including spatial resolution, low contrast detectability, uniformity, and HU sensitivity. Imaging dose measurements were acquired in Wellhofer Scanditronix i'mRT phantom at nominal phantom diameter and with additional 4 cm phantom diameter using GafChromic XRQA2 film. Calibration curves were generated using previously published in-air Air Kerma calibration method. Results: The OBI system full trajectory scans exhibited very little dependence on phantom thickness for accurate HU calculation, while half-trajectory scans with full-fan filter exhibited dependence of HU calculation on phantom thickness. The contrast-to-noise ratio (CNR) for the OBI scans decreased with additional phantom thickness. The uniformity of Head protocol scan was most significantly affected with additional phantom thickness. The spatial resolution and CNR compared favorably with pCT, while the uniformity of the OBI system was slightly inferior to pCT. The OBI scan protocol dose levels for nominal phantom thickness at the central portion of the phantom were 2.61, 0.72, and 1.88 cGy, and for additional phantom thickness were 1.95, 0.48, and 1.52 cGy, for the Pelvis, Thorax, and Spotlight protocols, respectively. The XVI system scans exhibited dependence on phantom thickness for accurate HU calculation regardless of trajectory. The CNR for the XVI scans decreased with additional phantom thickness. The uniformity of the XVI scans was significantly dependent on the selection of the proper FOV setting for all phantom geometries. The spatial resolution, CNR, and uniformity for XVI were lower than values measured for pCT. The XVI scan protocol dose levels at the central portion of the phantom for nominal phantom thickness were 2.14, 2.15, and 0.33 cGy, and for additional phantom thickness were 1.56, 1.68, and 0.21 cGy, for the Pelvis M20, Chest M20, and Prostate Seed S10 scan protocols, respectively. Conclusions: The OBI system offered comparable spatial resolution and CNR results to the results for pCT. Full trajectory scans with the OBI system need little-to-no correction for HU calculation based on HU stability with changing phantom thickness. The XVI system offered lower spatial resolution and CNR results than pCT. In addition, the HU calculation for all scan protocols was dependent on the phantom thickness. The uniformity for each CBCT system was inferior to that of pCT for each phantom geometry. The dose for each system and scan protocol in the interior of the phantom tended to decrease by approximately 25% with 4 cm additional phantom thickness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Parallel-scanning tomosynthesis using a slot scanning technique: Fixed-focus reconstruction and the resulting image quality

Purpose: Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. Methods: The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitched images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)–(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of −100, −50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. Results: The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the distance from the IFP increased. A visual evaluation of the spatial resolution using the x-ray test pattern indicated that the resolution was 1.8 lp/mm at the IFP and 1.2 lp/mm at heights of −100 and 100 mm from the IFP. The authors demonstrated that a spatial resolution of 1.2–1.8 lp/mm could be obtained within heights of 200 mm of the IFP. The slice sensitivity varied between 11.1 and 13.8 mm for heights between −50 and 100 mm, and there was no critical change in the slice sensitivity within a height range of 150 mm around the IFP. The phantom results demonstrated that tomosynthesis and long-view images could be reconstructed. Conclusions: PS-TS-F provides tomosynthesis images while using low-cost systems that have no tomographic scanning function, such as tableside-controlled universal R/F systems or universal radiographic systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Decadal Pathfinder Data Sets of Global Land Biophysical Variables from AVHRR and MODIS and their Use in GCM Studies of Biogeophysics and Biogeochemistry

The problem of how the scale, or spatial resolution, of reflectance data impacts retrievals of vegetation leaf area index (LAI) and fraction absorbed photosynthetically active radiation (PAR) has been investigated. We define the goal of scaling as the process by which it is established that LAI and FPAR values derived from coarse resolution sensor data equal the arithmetic average of values derived independently from fine resolution sensor data. The increasing probability of land cover mixtures with decreasing resolution is defined as heterogeneity, which is a key concept in scaling studies. The effect of pixel heterogeneity on spectral reflectances and LAI/FPAR retrievals is investigated with 1 km Advanced Very High Resolution Radiometer (AVHRR) data aggregated to different coarse spatial resolutions. It is shown that LAI retrieval errors at coarse resolution are inversely related to the proportion of the dominant land cover in such pixel. Further, large errors in LAI retrievals are incurred when forests are minority biomes in non-forest pixels compared to when forest biomes are mixed with one another, and vice-versa. A physically based technique for scaling with explicit spatial resolution dependent radiative transfer formulation is developed. The successful application of this theory to scaling LAI retrievals from AVHRR data of different resolutions is demonstrated

Myneni, Ranga↗

A cryogenically cooled, ultra-high-energy-resolution, trap-based positron beam

A technique is described to produce a pulsed, magnetically guided positron beam with significantly improved beam characteristics over those available previously. A pulsed, room-temperature positron beam from a buffer gas trap is used as input to a trap that captures the positrons, compresses them both radially and axially, and cools them to 50 K on a cryogenic CO buffer gas before ejecting them as a pulsed beam. The total energy spread of the beam formed using this technique is 6.9 ± 0.7 meV FWHM, which is a factor of ∼5 better than the previous state-of-the-art, while simultaneously having sub-microsecond temporal resolution and millimeter spatial resolution. Possible further improvements in beam quality are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pan-sharpening for microscopy

Techniques for generating full-spatial resolution, full spectral resolution image(s) from a 3D spectral-data cube for any spectral value within a given spectral range are provided without requiring the acquisition of all full-spatial resolution, full spectral resolution data by an instrument. The 3D spectral-data cube is generated from a limited number of full-spatial resolution, sparse spectral resolution data and a sparse-spatial resolution, full-spectral resolution data of the same area of the sample. The use of the 3D spectral-data cube reduces the data acquisition time.

Ovchinnikova, Olga S.↗

Multimodal hard x-ray imaging with resolution approaching 10 nm for studies in material science

We report multimodal scanning hard x-ray imaging with spatial resolution approaching 10 nm and its application to contemporary studies in the field of material science. The high spatial resolution is achieved by focusing hard x-rays with two crossed multilayer Laue lenses and raster-scanning a sample with respect to the nanofocusing optics. Various techniques are used to characterize and verify the achieved focus size and imaging resolution. Here, the multimodal imaging is realized by utilizing simultaneously absorption-, phase-, and fluorescence-contrast mechanisms. The combination of high spatial resolution and multimodal imaging enables a comprehensive study of a sample on a very fine length scale. In this work, the unique multimodal imaging capability was used to investigate a mixed ionic-electronic conducting ceramic-based membrane material employed in solid oxide fuel cells and membrane separations (compound of Ce 0.8 Gd 0.2 O 2–x and CoFe 2 O 4 ) which revealed the existence of an emergent material phase and quantified the chemical complexity at the nanoscale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-Angular-Resolution Microbeam X-Ray Diffraction with CCD Detector

We have introduced a CCD-type two-dimensional X-ray detector for a microbeam X-ray diffraction system using synchrotron radiation, so that we can measure local reciprocal space maps (RSM) of samples rapidly. A local RSM of a strain-relaxed SiGe 004 grown on a Si (001) substrate was measured in higher-angular-resolution and faster than a conventional way. The measurement was achieved in 1 h 40 min. with the 2theta resolution of 80 murad and the spatial resolution of 1.4(h)x0.5(v) {mu}m{sup 2}. The introduction of the CCD enabled us to measure RSMs at many points in a sample, that is, the distribution of strain fields and lattice tilts can be revealed in high-angular- and high-spatial-resolution.

36 MATERIALS SCIENCE↗

Sensitivity of Optical Satellites to Estimate Windthrow Tree-Mortality in a Central Amazon Forest

Windthrow (i.e., trees broken and uprooted by wind) is a major natural disturbance in Amazon forests. Images from medium-resolution optical satellites combined with extensive field data have allowed researchers to assess patterns of windthrow tree-mortality and to monitor forest recovery over decades of succession in different regions. Although satellites with high spatial-resolution have become available in the last decade, they have not yet been employed for the quantification of windthrow tree-mortality. Here, we address how increasing the spatial resolution of satellites affects plot-to-landscape estimates of windthrow tree-mortality. We combined forest inventory data with Landsat 8 (30 m pixel), Sentinel 2 (10 m), and WorldView 2 (2 m) imagery over an old-growth forest in the Central Amazon that was disturbed by a single windthrow event in November 2015. Remote sensing estimates of windthrow tree-mortality were produced from Spectral Mixture Analysis and evaluated with forest inventory data (i.e., ground true) by using Generalized Linear Models. Field measured windthrow tree-mortality (3 transects and 30 subplots) crossing the entire disturbance gradient was 26.9 ± 11.1% (mean ± 95% CI). Although the three satellites produced reliable and statistically similar estimates (from 26.5% to 30.3%, p < 0.001), Landsat 8 had the most accurate results and efficiently captured field-observed variations in windthrow tree-mortality across the entire gradient of disturbance (Sentinel 2 and WorldView 2 produced the second and third best results, respectively). As expected, mean-associated uncertainties decreased systematically with increasing spatial resolution (i.e., from Landsat 8 to Sentinel 2 and WorldView 2). However, the overall quality of model fits showed the opposite pattern. We suggest that this reflects the influence of a relatively minor disturbance, such as defoliation and crown damage, and the fast growth of natural regeneration, which were not measured in the field nor can be captured by coarser resolution imagery. Our results validate the reliability of Landsat imagery for assessing plot-to-landscape patterns of windthrow tree-mortality in dense and heterogeneous tropical forests. Satellites with high spatial resolution can improve estimates of windthrow severity by allowing the quantification of crown damage and mortality of lower canopy and understory trees. However, this requires the validation of remote sensing metrics using field data at compatible scales.

54 ENVIRONMENTAL SCIENCES↗

The Soft X-ray Spectromicroscopy Beamline at SSRF

Commissioning of the soft x-ray spectromicroscopy beanmline at SSRF was formally started on Dec 26, 2008. Beamline performance has reached or surpassed the designing goals according to the measurements by domestic experts, especially for its high energy resolution and high spatial resolution. Since its first operation by users on May 6, 2009, tens of experiments have been conducted, and some preliminary exciting results have been acquired.

07 ISOTOPE AND RADIATION SOURCES↗

Imaging Single Atoms Using Secondary Electrons with an Aberration-Corrected Electron Microscope

Aberration correction has embarked on a new frontier in electron microscopy by overcoming the limitations of conventional round lenses, providing sub-angstrom-sized probes. However, improvement of spatial resolution using aberration correction so far has been limited to the use of transmitted electrons both in scanning and stationary mode, with an improvement of 20-40%. In contrast, advances in the spatial resolution of scanning electron microscopes (SEMs), which are by far the most widely used instrument for surface imaging at the micrometre-nanometre scale, have been stagnant, despite several recent efforts. Here, we report a new SEM, with aberration correction, able to image single atoms by detecting electrons emerging from its surface as a result of interaction with the small probe. The spatial resolution achieved represents a fourfold improvement over the best-reported resolution in any SEM. Furthermore, we can simultaneously probe the sample through its entire thickness with transmitted electrons. This ability is significant because it permits the selective visualization of bulk atoms and surface ones, beyond a traditional two-dimensional projection in transmission electron microscopy. It has the potential to revolutionize the field of microscopy and imaging, thereby opening the door to a wide range of applications, especially when combined with simultaneous nanoprobe spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution Cerenkov light imaging of induced positron distribution in proton therapy

Purpose: In proton therapy, imaging of the positron distribution produced by fragmentation during or soon after proton irradiation is a useful method to monitor the proton range. Although positron emission tomography (PET) is typically used for this imaging, its spatial resolution is limited. Cerenkov light imaging is a new molecular imaging technology that detects the visible photons that are produced from high-speed electrons using a high sensitivity optical camera. Because its inherent spatial resolution is much higher than PET, the authors can measure more precise information of the proton-induced positron distribution with Cerenkov light imaging technology. For this purpose, they conducted Cerenkov light imaging of induced positron distribution in proton therapy. Methods: First, the authors evaluated the spatial resolution of our Cerenkov light imaging system with a {sup 22}Na point source for the actual imaging setup. Then the transparent acrylic phantoms (100 × 100 × 100 mm{sup 3}) were irradiated with two different proton energies using a spot scanning proton therapy system. Cerenkov light imaging of each phantom was conducted using a high sensitivity electron multiplied charge coupled device (EM-CCD) camera. Results: The Cerenkov light’s spatial resolution for the setup was 0.76 ± 0.6 mm FWHM. They obtained high resolution Cerenkov light images of the positron distributions in the phantoms for two different proton energies and made fused images of the reference images and the Cerenkov light images. The depths of the positron distribution in the phantoms from the Cerenkov light images were almost identical to the simulation results. The decay curves derived from the region-of-interests (ROIs) set on the Cerenkov light images revealed that Cerenkov light images can be used for estimating the half-life of the radionuclide components of positrons. Conclusions: High resolution Cerenkov light imaging of proton-induced positron distribution was possible. The authors conclude that Cerenkov light imaging of proton-induced positron is promising for proton therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE BLACK HOLE MASSES AND STAR FORMATION RATES OF z>1 DUST OBSCURED GALAXIES: RESULTS FROM KECK OSIRIS INTEGRAL FIELD SPECTROSCOPY

We have obtained high spatial resolution Keck OSIRIS integral field spectroscopy of four z {approx} 1.5 ultra-luminous infrared galaxies that exhibit broad H{alpha} emission lines indicative of strong active galactic nucleus (AGN) activity. The observations were made with the Keck laser guide star adaptive optics system giving a spatial resolution of 0.''1 or <1 kpc at these redshifts. These high spatial resolution observations help to spatially separate the extended narrow-line regions-possibly powered by star formation-from the nuclear regions, which may be powered by both star formation and AGN activity. There is no evidence for extended, rotating gas disks in these four galaxies. Assuming dust correction factors as high as A(H{alpha}) = 4.8 mag, the observations suggest lower limits on the black hole masses of (1-9) x 10{sup 8} M{sub sun} and star formation rates <100 M{sub sun} yr{sup -1}. The black hole masses and star formation rates of the sample galaxies appear low in comparison to other high-z galaxies with similar host luminosities. We explore possible explanations for these observations, including host galaxy fading, black hole growth, and the shut down of star formation.

79 ASTRONOMY AND ASTROPHYSICS↗