Search NASA⌕ Search

SEARCH · Search NASA

Results for “transient testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

DEVELOPMENT OF TRANSIENT FISSION GAS RELEASE CAPABILITIES TO STUDY HIGH BURNUP COMMERCIAL FUEL PERFORMANCE UNDER LOSS OF COOLANT ACCIDENT CONDITIONS

The contribution of transient fission gas release to the burst behaviour of high burnup fuel during a loss of coolant accident (LOCA) for commercial light water reactors is a complex phenomenon that is not fully understood. During the temperature ramp associated with a LOCA, there is significant, additional transient fission gas release in excess of steady state fission gas release from normal operation. The timing of this release and the various conditions that impact this release warrant further study. To better characterize this phenomenon, a system was developed to capture and characterize fission gas released from irradiated fuel during simulated LOCAs. This system is an upgrade to the existing Oak Ridge National Laboratory Severe Accident Test Station LOCA test apparatus and detects fission gas by gamma counting cryogenically cooled cold traps and by using an online gas mass spectrometer. The examined fuel can be pressurized or open to the furnace atmosphere. The design and operation of this new capability are discussed. Results from the first tests on high burnup fuel are presented. In the initial test, the LOCA relevant transient fission gas release was 5.3% for an unpressurized segment. Post-test microscopy on the tested samples is presented to demonstrate the likely radial source of transient fission gas release.

Harp, Jason↗

Short Communication: Observation of Initial Burst Release of Fission Gas from High-Burnup UO 2 Nuclear Fuel During Thermal Transient

A system was developed and tested to provide a deeper understanding of the fission gas release kinetics from nuclear fuel during thermal transients. Pressure, temperature, spectral data, and optical images were simultaneously collected during resistive sample heating, and all released gases were collected in liquid nitrogen-cooled charcoal traps. Standup testing was performed with a high-burnup nuclear fuel segment from rod section with an average local burnup of 77 GWd/tU. During heating, the segment released approximately 6 ± 2% of generated fission gas inventory after ramp heating to 460°C. Here, heating ceased when the sample ejected from the holder, as observed by constant imaging.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Control Performance of General Electric Fuel and Torque Regulator Operating on T31-3 Turbine-Propeller Engine in Sea-Level Test Stand

A .General Electric fuel and torque regulator was tested in conjunction with a T31-3 turbine-propeller engine in the sea-level static test stand at the NACA Lewis laboratory. The engine and control were operated over the entire speed range: 11,000 rpm, nominal flight idle, to 13,000 rpm, full power. Steady-state and transient data were recorded and are presented with a description of the four control loops being used in the system. Results of this investigation indicated that single-lever control operation was satisfactory under conditions of test. Transient data presented showed that turbine-outlet temperature did overshoot maximum operating value on acceleration but that the time duration of overshoot did not exceed approximately 1 second. This temperature limiting resulted from a control on fuel flow as a function of engine speed. Speed and torque first reached their desired values 0.4 second from the time of change in power-setting lever position. Maximum speed overshoot was 3 percent.

Oppenheimer, Frank L.↗

An improved prediction of residual stresses and distortion in additive manufacturing

In laser assisted additive manufacturing (AM) an accurate estimation of residual stresses and distortion is necessary to achieve dimensional accuracy and prevent premature fatigue failure, delamination and buckling of components. Since many process variables affect AM, experimental measurements of residual stresses and distortion are time consuming and expensive. Numerical thermo-mechanical models can be used for their estimation, but the quality of calculations depends critically on the accurate transient temperature field which affects both the residual stresses and distortion. Here in this study, a well-tested, three-dimensional, transient heat transfer and fluid flow model is used to accurately calculate transient temperature field for the residual stress and distortion modeling. The calculated residual stress distributions are compared with independent experimental results. It is shown that the residual stresses can be significantly minimized by reducing the layer thickness during AM. Inconel 718 components are found to be more susceptible to delamination than Ti-6Al-4V parts because they encounter higher residual stresses compared to their yield strength.

36 MATERIALS SCIENCE↗

Response of surge protection devices to fast rising pulses

Two types of lightning protection modules incorporating leadless (pill type) Zener like devices were evaluated with regard to their ability to suppress EMP induced transients. Two series of tests were performed to evaluate the ability of these modules to react to fast rate of rise ( 1Kv/ns) transients, and the attenuation introduced and the ability to limit damped sinusoid pulses which may be induced due to an EMP resulting from a nuclear detonation.

Mindel, I. N.↗

Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

International Conference on Envronmental Systems (ICES), Seattle WA NCTS 20964-15. The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earths magnetosphere as a laboratory tostudy the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10-4 Pa (10-6 torr)and the surrounding temperature achieving -180 C. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperatureversus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDAFLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 C of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 C and the heater power goal is to be within 5 of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.

Thermal↗

Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earth's magnetosphere as a laboratory to study the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10 (sup -4) pascals (10 (sup -6) torr) and the surrounding temperature achieving -180 degrees Centigrade. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperature versus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDA/FLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 degrees Centigrade of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 degrees Centigrade and the heater power goal is to be within 5 percent of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.

Correlation↗

Resource Prospector Propulsion System Cold Flow Testing

Resource Prospector (RP) is a NASA mission being led by NASA Ames Research Center with current plans to deliver a scientific payload package aboard a rover to the lunar surface. As part of an early risk reduction activity, Marshall Space Flight Center (MSFC) and Johnson Space Flight Center (JSC) have jointly developed a government-version concept of a lunar lander for the mission. The spacecraft consists of two parts, the lander and the rover which carries the scientific instruments. The lander holds the rover during launch, cruise, and landing on the surface. Following terminal descent and landing the lander portion of the spacecraft become dormant after the rover embarks on the science mission. The lander will be equipped with a propulsion system for lunar descent and landing, as well as trajectory correction and attitude control maneuvers during transit to the moon. Hypergolic propellants monomethyl hydrazine and nitrogen tetroxide will be used to fuel sixteen 70-lbf descent thrusters and twelve 5-lbf attitude control thrusters. A total of four metal-diaphragm tanks, two per propellant, will be used along with a high-pressure composite-overwrapped pressure vessel for the helium pressurant gas. Many of the major propulsion system components are heritage missile hardware obtained by NASA from the Air Force. In parallel with the flight system design activities, a simulated propulsion system based on flight drawings was built for conducting a series of water flow tests to characterize the transient fluid flow of the propulsion system feed lines and to verify the critical operation modes such as system priming, waterhammer, and crucial mission duty cycles. The primary objective of the cold flow testing was to simulate the RP propulsion system fluid flow operation through water flow testing and to obtain data for anchoring analytical models. The models will be used to predict the transient and steady state flow behaviors in the actual flight operations. All design and build efforts, including the analytical modeling, have been performed. The cold flow testing of the propulsion system was set up and conducted at a NASA MSFC test facility. All testing was completed in the summer of 2014, and this paper documents the results of that testing and the associated fluid system modeling efforts.

Williams, Hunter↗

Nonlinear Whirl Response of a High-Speed Seal Test Rotor With Marginal and Extended Squeeze-Film Dampers

Synchronous and nonsynchronous whirl response analysis of a double overhung, high-speed seal test rotor with ball bearings supported in 5.84- and 12.7-mm-long, un-centered squeeze-film oil dampers is presented. Test performance with the original damper of length 5.84 mm was marginal, with nonsynchronous whirling at the overhung seal test disk and high amplitude synchronous response above 32,000 rpm near the drive spline section occurring. A system critical speed analysis of the drive system and the high-speed seal test rotor indicated that the first two critical speeds are associated with the seal test rotor. Nonlinear synchronous unbalance and time transient whirl studies were conducted on the seal test rotor with the original and extended damper lengths. With the original damper design, the nonlinear synchronous response showed that unbalance could cause damper lockup at 33,000 rpm. Alford cross-coupling forces were also included at the overhung seal test disk for the whirl analysis. Sub-synchronous whirling at the seal test disk was observed in the nonlinear time transient analysis. With the extended damper length of 12.7 mm, the sub-synchronous motion was eliminated and the rotor unbalance response was acceptable to 45,000 rpm with moderate rotor unbalance. However, with high rotor unbalance, damper lockup could still occur at 33,000 rpm, even with the extended squeeze-film dampers. Therefore, the test rotor must be reasonably balanced in order for the un-centered dampers to be effective.

Proctor, Margaret P.↗

Transient Modelling of HTGR Thermal Load Follow in Modelica

The ability of nuclear power plants to load follow electrical power demand is particularly important as we move to higher variable renewable (VRE) energy production on low carbon energy grids. High temperature gas reactors (HTGRs) are capable of load following by adjusting thermal output, but their high temperatures and thermal inertia significantly impact the power transients they are able to follow. To aid investigation into new integrated energy systems with advanced reactors, it is necessary to have an open-source transient model of a full HTGR primary and secondary. This paper introduces two new open-source models for a HTGR and corresponding balance of plant (BOP) written for the HYBRID library developed at Idaho National Laboratory. A transient thermal load follow test case was taken by the work from Brits et al. to benchmark our open-source model against transient operation results from other proprietary codes that exist. The control scheme for the two new models in combination is discussed and a comparison of the response in transient load follow between the two codes performed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal hydraulic model of the molten salt reactor experiment with the NEAMS system analysis module

System analysis codes have a long history of providing best-estimate and conservative safety analysis for both light water and advanced reactor technologies, including molten salt reactors. As interest continues to expand with advanced reactor concepts, system analysis codes will need revisions to accommodate the behavior of these technologies. Legacy system analysis codes will need to be updated to the latest numerical techniques to shorten execution time and increase the accuracy of results. One example of a modern system analysis code that already encompasses these characteristics is the System Analysis Module (SAM). One key objective of this paper was to review available information for system code modeling of the Molten Salt Reactor Experiment (MSRE) from sources in the open literature and collect the information from these open sources in one place for the first time. This supports the potential objective of developing an open specification for system code analysis for MSRE steady state and transients with and without reactor kinetics. Data from actual MSRE tests will serve as the basis for code-to-code comparison exercises, including the MSRE zero power physics tests, the fuel pump start-up and coast down tests, and the natural circulation transient. The objective is to produce a code-to-code benchmark with a standardized set of comparison problems, recognizing the limitations of the original data. To demonstrate an initial application of this objective and the usefulness of compiling this open data, two Molten Salt Reactor Experiment (MSRE)-related models were developed to evaluate SAM for liquid fueled molten salt reactors. One model was the SAM MSRE hydraulic mockup, which provided experimental data for pressure drop measurements. The second model was the complete MSRE primary loop. The MSRE primary loop model incorporated a fluoride salt fuel/coolant with heat transfer in both the core and heat exchanger. For both the hydraulic mockup and MSRE primary loop models, a holistic 1-D system description was built using open documentation, an open description that can be readily modified and applied for any system analysis code. SAM results for the pressure drop of the hydraulic mockup model were within 6% with measurements. Coolant temperatures for the primary loop model matched the expected axial change in temperature from historical calculations. Using alternative coolant properties obtained from the literature, corresponding to salts with different actinide contents, returned similar trends in core temperature profiles. A thermal hydraulic demonstration of a loss-of-flow transient showed the importance of coupling SAM thermal hydraulic analysis to neutronics. Here, this coupling is essential for simulating MSR transients with system analysis codes.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

10 kW solar array switching unit performance test results

Solar array switching unit (SASU) technology is an attractive candidate for output power regulation of solar arrays. It offers greater efficiency, lower parts count, modularity and expandability. Since the SASU has switching frequencies upwards of 15 kHz, it was necessary to determine the performance characteristics of the SASU with a real solar array and to assess the impact of long lead lengths on the switching characteristics. To accommodate these requirements, TRW developed a 10 kW, 120 volt SASU which was tested for steady state and transient resistive and converter type loadings. The results of these tests are presented and discussed in this paper.

Fleck, G. W.↗

EGR Control for Emisson Reduction Using Fast Response Sensors - Phase 1A

The overall objective of this project was to develop exhaust gas recirculation (EGR) control strategies using fast-response Particulate Matter (PM) sensors and NOx sensors to improve the quality of particulate and gaseous emissions from diesel engines. This project initially comprised three phases: (1) Phase IA - sensor requirements to meet PM sensor specifications, NOx sensor assessment, and initial model development for EGR control; (2) Phase IB - continue development on PM and NOx sensors, integrate the sensor signals into the control simulations, and finalize model development for control strategies; and (3) Phase II - validation testing of the control strategies. Only Phase 1A was funded by DOE and executed by Honeywell. The major objectives of Phase 1A of the project included: (1) Sensor validation and operation of fast-response PM and NOx sensors; (2) Control system modeling of low-pressure EGR controls, development of control strategies, and initial evaluation of these models and strategies for EGR control in diesel engines; (3) Sensor testing to understand applicability of fast-response PM sensors in determining loading rates of the particle trap; and (4) Model validation and sensor testing under steady-state and transient operational conditions of actual engines. In particular, specific objectives included demonstration of: (1) A PM sensor response time constant (T10 - T90) of better than 100 milliseconds (msec); (2) The ability to detect PM at concentrations from 0.2 to 2 Bosch smoke number (BSN) or equivalent; (3) PM sensor accuracy to within 20% BSN over the entire range of operation; and (4) PM sensor repeatability to within 10% over the PM entire sensor range equivalent to a BSN of 0.2 to 2.

33 ADVANCED PROPULSION SYSTEMS↗

Heat flux measurements

A new automated, computer controlled heat flux measurement facility is described. Continuous transient and steady-state surface heat flux values varying from about 0.3 to 6 MW/sq m over a temperature range of 100 to 1200 K can be obtained in the facility. An application of this facility is the development of heat flux gauges for continuous fast transient surface heat flux measurement on turbine blades operating in space shuttle main engine turbopumps. The facility is useful for durability testing at fast temperature transients.

Liebert, Curt H.↗

Improved Models for Simulation of Cryogenic Spray Cooling for Propellant Tank Chilldown

This paper presents advances in spray boiling models for cryogenic fluids that exhibit strong variation in thermodynamic properties; it accounts for the interaction of the spray droplets with walls and the complex heat transfer and boiling processes that play a vital role in chilling solid surfaces. The model has been developed by corroborating and validating it with test data in liquid nitrogen obtained at the University of Connecticut. The test data includes detailed visualization and plate temperature measurements for liquid nitrogen sprays impinging on a warm test plate and subsequent transient chilldown of the plate. Simulations of transient plate chilldown in liquid nitrogen were carried out and temperature histories at various locations on the plate were compared with test measurements. The final paper will present sensitivity studies and additional comparisons with test data.

Computational Fluid Dynamics, Cryogenic, Spray Chi↗

Improved Models for Simulation of Cryogenic Spray Cooling for Propellant Tank Chilldown

This paper presents advances in spray boiling models for cryogenic fluids that exhibit strong variation in thermodynamic properties; it accounts for the interaction of the spray droplets with walls and the complex heat transfer and boiling processes that play a vital role in chilling solid surfaces. The model has been developed by corroborating and validating it with test data in liquid nitrogen obtained at the University of Connecticut. The test data includes detailed visualization and plate temperature measurements for liquid nitrogen sprays impinging on a warm test plate and subsequent transient chilldown of the plate. Simulations of transient plate chilldown in liquid nitrogen were carried out and temperature histories at various locations on the plate were compared with test measurements to demonstrate the validity of the spray boiling models that have been developed for cryogens.

Boiling↗

Improved Models for Simulation of Cryogenic Spray Cooling for Propellant Tank Chilldown

This paper presents advances in spray boiling models for cryogenic fluids that exhibit strong variation in thermodynamic properties; it accounts for the interaction of the spray droplets with walls and the complex heat transfer and boiling processes that play a vital role in chilling solid surfaces. The model has been developed by corroborating and validating it with test data in liquid nitrogen obtained at the University of Connecticut. The test data includes detailed visualization and plate temperature measurements for liquid nitrogen sprays impinging on a warm test plate and subsequent transient chilldown of the plate. Simulations of transient plate chilldown in liquid nitrogen were carried out and temperature histories at various locations on the plate were compared with test measurements to demonstrate the validity of the spray boiling models that have been developed for cryogens.

Boiling↗

Heat flux measurements

This paper discusses a new automated, computer-controlled heat flux measurement facility. Continuous transient and steady-state surface heat flux values varying from about 0.3 to 6 MW/sq m over a temperature range of 100 to 1200 K can be obtained in the facility. An application of this facility is the development of heat flux gages for continuous fast transient surface heat flux measurement on turbine blades operating in Space Shuttle main engine turbopumps. The facility is also useful for durability testing at fast temperature transients.

Liebert, Curt H.↗