Search NASASearch

SEARCH · Search NASA

Results for “wind energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,025 records · Page 41

A molecular conveyor belt-associated protein controls the rotational direction of the bacterial type 9 secretion system

ABSTRACT Many bacteria utilize the type 9 secretion system (T9SS) for gliding motility, surface colonization, and pathogenesis. This dual-function motor supports both gliding motility and protein secretion, where rotation of the T9SS plays a central role. Fueled by the energy of the stored proton motive force and transmitted through the torque of membrane-anchored stator units, the rotary T9SS propels an adhesin-coated conveyor belt along the bacterial outer membrane like a molecular snowmobile, thereby enabling gliding motion. However, the mechanisms controlling the rotational direction and gliding motility of T9SS remain elusive. Shedding light on this mechanism, we find that in the gliding bacteriumFlavobacterium johnsoniae, deletion of the C-terminus of the conveyor belt-associated protein GldJ controls and, in fact, reverses the rotational direction of T9SS from counterclockwise (CCW) to clockwise (CW). This suggests that the interface between the conveyor belt-associated protein GldJ and the T9SS ring protein GldK plays an important role in controlling the directionality of T9SS, potentially by modulating its interaction with the stator complex GldLM, which drives motor rotation. Combined with MD simulation of the T9SS stator units GldLM, we suggest a “tri-component gearset” model where GldJ controls the rotational direction of its driver, the T9SS, thus providing adaptive sensory feedback to influence the motility of the gliding bacterium. IMPORTANCE The type 9 secretion system (T9SS) is fundamental to bacterial gliding motility, pathogenesis, and surface colonization. Our findings reveal that the C-terminal region of the conveyor belt-associated protein GldJ functions as a molecular switch which is capable of reversing the rotational direction of T9SS. Through the coordinated actions of the T9SS stator units (akin to a driving motor), the GldK ring (the gear that converts rotational energy into linear movement), and GldJ, this machinery forms a smart conveyor belt system reminiscent of flexible or cognitive mechanical conveyors. Such advanced conveyors can alter their direction to adapt to shifting demands. Here, we show that the bacterial T9SS similarly adjusts its rotational bias based on feedback from the conveyor belt-associated protein GldJ. This dual-role feedback mechanism underscores an evolved, controllable biological snowmobile, offering new avenues for studying how bacteria fine-tune motility in dynamic environments.

Microbiology

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING

Assembly and Testing of Scintillator Tile Modules for the CMS High-Granularity Calorimeter Upgrade

The High-Granularity Calorimeter (HGCAL), part of the upgrade to the Compact Muon Solenoid (CMS) experiment, employs silicon and scintillator tile modules in the endcaps to maintain detector performance during the High-Luminosity Large Hadron Collider (HL-LHC) era, scheduled to operate from 2030 to 2040. The upgraded calorimeter will provide highly segmented three-dimensional imaging, energy measurements, and precise timing for particle shower reconstruction. Approximately half of the HGCal plastic scintillator tile modules (1,834 total) will be assembled at Fermilab using an automated pick-and-place (PnP) machine. Following assembly, each tile module undergoes quality control (QC) procedures such as electrical validation, thermal testing, and physics validation using cosmic rays. This poster/talk presents the QC procedures and results from the tile module production in 2026, demonstrating the performance and quality of the assembled tile modules.

Bazimya, Jean Luc [Grambling State U.]

Wettability of Two-Dimensional Carbon Allotropes from Molecular Simulations

Force-field Monte Carlo and Molecular Dynamics simulations are used to compare wetting behaviors of model carbon sheets mimicking neat graphene, its saturated derivative, graphane, and related planar allotropes penta-graphene, γ-graphyne, and ψ-graphene in contact with aqueous droplets or an aqueous film confined between parallel carbon sheets. Atomistic and area-integrated surface/water potentials are found to be essentially equivalent in capturing moderate differences between the wetting free energies of tested substrates. Despite notable differences in mechanical and electric properties of distinct allotropes, the predicted allotrope/water contact angles span a narrow window of weakly hydrophilic values. Contact angles in the range of 80 ± 10° indicate modest hydration repulsion incapable of competing with van der Waals attraction between carbon particles. Poor dispersibility in neat water is hence a common feature of studied materials.

Biochemistry & Molecular Biology

Multi-purpose quantum laboratories from superconducting circuits

Superconducting circuits (SCs) are the cornerstone of modern quantum technology, enabling scalable computing through coherent control of macroscopic quantum states. Through a legacy that predates modern quantum computing, SCs have emerged as high-precision instruments for discovery. In this review, we highlight the role of SCs as general-purpose quantum laboratories, outlining the emerging landscape of correlated matter-circuit science. We review and unify the capabilities of superconducting quantum hardware across condensed matter, high energy and quantum information sciences. We trace the technical evolution of these architectures, illustrating how their foundational development has culminated in a toolkit for resolving the complexities of macroscopic quantum states.

Arora, Arpit [UCLA, Los Angeles (main); UCLA; Haim

Surface analysis insight note: Illustrating the effect of adventitious contamination on Pt photoemission peak intensities

Adventitious carbon contaminations are not only omnipresent and used for charge referencing of XPS spectra but also can alter the apparent presence of the element peaks that span over the large spectral window of binding energies. This Insight note describes the effect of an adventitious contamination layer on Pt and presents, in brief, the approach whereby the component spectra are derived for ion beam cleaned Pt samples that can then utilize linear mathematics to peak fit said spectra thus quantifying the amount of each component including that assigned to the contamination itself of Pt metal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Electrostatic‐Attraction‐Driven Self‐Assembled Graphene‐Disordered Rocksalt Composite Cathode for Lithium‐Ion Batteries

Disordered rocksalt cathodes hold promise for achieving high-capacity lithium-ion batteries while using low-cost, earth-abundant elements. However, their electrochemical performance remains critically limited by their poor electronic conductivity. Conventional strategies such as high-energy ball milling with excess carbon additives can improve conductivity but remain challenging to scale and often produce defects and increase surface area, thereby accelerating capacity degradation. Herein, we report an alternative approach of electrostatic-attraction-driven self-assembly to fabricate Li 1.2 Mn 0.6 Ti 0.2 O 1.8 F 0.2 (LMTOF) particles uniformly wrapped with electronically conductive graphene sheets without associated materials degradation. The graphene-wrapped LMTOF demonstrates significantly improved cycling stability (89% capacity retention after 100 cycles) and superior rate capability compared with an LMTOF-carbon composite electrode fabricated using the conventional high-energy ball-milling process. Post-cycling analysis reveals reduced oxygen evolution, suppressed unwanted side reactions, and improved structural integrity for the graphene-LMTOF composite. This work highlights the advantages of solution-based carbon wrapping and offers a scalable strategy to prepare high-performance DRX cathodes for lithium-ion batteries.

carbon composite

International Space Station Lithium-Ion Battery Start-Up and Cycling

The International Space Station (ISS) primary Electric Power System (EPS) was originally designed to use Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the ISS is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries were designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. In 2010, the ISS Program began the development of Lithium-Ion (Li-Ion) batteries to replace Ni-H2 batteries approaching the end of their useful life and concurrently funded a Li-Ion ORU (Orbital Replacement Unit) and cell life testing project. The first set of 6 Li-ion battery replacements was launched in December 2016 and deployed in January 2017. This paper will discuss the Li-ion battery on-orbit cycling and the status of the Li-Ion cell and ORU life cycle testing.

International Space Station

Manufacturing Research in Support of Saturn V

Research achievements applicable to the production of Saturn V components a r e described in this report. Leakage at the mechanical connections in high-pressure lines has been minimized or eliminated through the use of precisely flared tubes. Flaring to close tolerance is done with a n orbital flaring adapter, and the forming operation is precisely controlled with an electronic control console. A technique of “aging” or heat-treatment hardening of aluminum materials has been used to form cylindrical-tank segments and double-contoured gore segments precisely, and to remove weld distortions). The control of weld porosity has been improved as a result of research which demonstrated the close correlation between electrical energy input per inch of weld and weld porosity and metallurgical quality. Based on this information, the gas metallic arc method has been used successfully for two-pass welding, and thinner gage aluminum has been welded (LOX tunnel to fuel bulkhead) with an MSFC designed gas metallic arc unit.

COMPOSITE MATERIAL

Nuclear Security Risks for HALEU Fuels

There is growing interest in high-assay low-enriched uranium (HALEU) for use in advanced nuclear reactors as a high-energy fuel source. The primary objectives of this report are to identify the security risks that directly result from HALEU and to identify the gaps and challenges it presents from a theft and sabotage perspective. This study focuses on HALEU security risks for the front end of the fuel cycle and includes a review of the supply chain, fuel fabrication, and transport for terrestrial reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

RTE: A Computer Code for Rocket Thermal Evaluation

The numerical model for a rocket thermal analysis code (RTE) is discussed. RTE is a comprehensive thermal analysis code for thermal analysis of regeneratively cooled rocket engines. The input to the code consists of the composition of fuel/oxidant mixture and flow rates, chamber pressure, coolant temperature and pressure. dimensions of the engine, materials and the number of nodes in different parts of the engine. The code allows for temperature variation in axial, radial and circumferential directions. By implementing an iterative scheme, it provides nodal temperature distribution, rates of heat transfer, hot gas and coolant thermal and transport properties. The fuel/oxidant mixture ratio can be varied along the thrust chamber. This feature allows the user to incorporate a non-equilibrium model or an energy release model for the hot-gas-side. The user has the option of bypassing the hot-gas-side calculations and directly inputting the gas-side fluxes. This feature is used to link RTE to a boundary layer module for the hot-gas-side heat flux calculations.

Mohammad H N Naraghi

Multifaceted Considerations for Fission Surface Power Radiation Shielding Design

The purpose of the Fission Surface Power (FSP) nuclear system is to provide energy on the Moon and Mars for supporting their exploration and colonization. The FSP design and deployment can leverage the past research and development work in areas, such as reactor design, but such crucial components as radiation shielding and instrumentation still need material and manufacturing studies, modeling, and testing. The shielding components are needed for the protection of humans, electronics, and sensitive components. They are essential system components, but they are often the heaviest components of the system for which each kilogram matters. Different material combinations and layouts are possible. The studies presented were focused on the evaluation of several options. The initial analysis included their performance assessment, initial temperature distribution evaluation and manufacturability considerations. Several feasible shield design options were identified and discussed in this paper, as well.

Fission Surface Power

Long‐Life Lithium‐Metal Batteries with an Ultra‐High‐Nickel Cathode and Electrolytes with Bi‐Anion Activity

Abstract Anion chemistry in electrolytes can greatly dictate the nature and quality of passivation layers on both cathode and anode surfaces. This will be more significant when it comes to highly reactive Li‐metal anode and aggressive high‐nickel cathodes. Herein, a competitive bi‐anion activity is found in electrolytes with the co‐existence of two anions, which leads to a controlled Li‐salt decomposition kinetics and entirely favorable interphasial chemistry on both Li‐metal anode and ultrahigh‐nickel cathode. The proposed bi‐anion localized high‐concentration electrolytes are demonstrated to exhibit superior electrochemical compatibility toward Li metal and long‐term cycling stabilities under both 4.4 and 4.6 V in Li‐metal batteries with ultrahigh‐nickel cathode. This study sheds fresh light on dendrite‐free Li‐metal anodes and provides guidance to achieve high‐energy‐density batteries.

Chemistry

Revolutionizing thermal Management in Next-Generation AI data centers: Challenges and breakthrough innovations

Data centers (DCs) serve as critical infrastructure for powering the growth and evolution of AI. Next-generation AI DCs present unique challenges in thermal management driven by unprecedented computational demands. This paper provides a comprehensive summary of key stakeholder perspectives on technology gaps, infrastructure requirements, test bed needs, emerging opportunities, and preliminary solutions related to thermal management for AI DCs. It establishes six strategic pillars of thermal management for next generation AI DC: reliability, deployability, efficiency, resilience, measurability, and valorization. The discussion spans a range of critical topics, including advanced cooling technologies, thermal strategies for emerging modular and edge DCs, system-level optimization and control frameworks, infrastructure planning and grid integration designs, benchmarking approaches, and pathways for waste heat recovery and reuse. The proposed research, development, and demonstration efforts are aimed at accelerating the deployment of AI DCs while ensuring energy efficiency, reliability, safety, and regulatory compliance.

Wang, Pengtao [ORNL] (ORCID:0000000214713429)

High speed laser-induced refractive index change in ophthalmic HEMA hydrogel using a line focus

Laser-induced refractive index change (LIRIC) techniques typically focus femtosecond laser pulses to a tight spot to achieve the high intensities required to alter ophthalmic materials. A line-focus implementation using 800 nm pulses at 1 kHz repetition rate has been shown to greatly increase the effective writing speed of the process, but the high pulse energies used led to nonlinear propagation effects, presenting challenges for the fabrication of ophthalmic correctors. By taking advantage of the lower effective order of multiphoton absorption for 514 nm pulses, power levels may be reduced, allowing overlapped pulse writing. We demonstrate that this allows high-quality phase bars and devices to be made at high speeds.

Manning, Zachary A. [University of Rochester, NY (

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Impact of Advances in Anion Exchange Membranes and Ionomers on Alkaline Fuel Cells

Abstract The operation of low‐temperature electrochemical energy conversion systems (fuel cells, electrolyzers) at high pH values is of perennial interest due to the possibility of moving away from expensive platinum group metal catalysts and reducing cost. Historically, the anion exchange membranes (AEMs) and ionomers have been hampered by performance (ionic conductivity, mechanical strength) and chemical stability issues. In this context, select developments over the past decade in alternate AEM chemistries, water management methods, and production of membrane electrode assemblies (MEAs) that have enabled a significant leap in performance of alkaline fuel cells are examined. These developments are linked to performance improvements in alkaline H 2 /O 2 fuel cells and also consider developments in alkaline fuel cells using nitrogen‐containing fuels (ammonia, hydrazine), carbon‐containing fuels (alcohols, glycols), and boron‐containing fuels (sodium borohydride, ammonia borane). Finally, current challenges and bottlenecks are identified, and potential solutions are proposed.

Chemistry

Battery Systems for X-38 Crew Return Vehicle (CRV) and Deorbit Propulsion Stage (DPS)

A 28V 32 Ah cell Li/MnO2 and a 28V NiMH battery systems for the Deorbit Propulsion Stage (DPS) and the X-38 Crew Return Vehicle (CRV) are developed in Friwo-Silforkraft, Germany with the following objectives and approach: Provide safe battery designs for lowest volume and cost, and within schedule; Take advantage of less complex requests for V201 vs OPS CRV to simplify design and reduce cost; Use only existing commercial cell designs as building blocks for larger battery; Derive battery designs from the ASTRO-SPAS design which is the largest lithium battery design with Shuttle flight experience; Place maximum amount of battery energy on DPS; DPS battery is non rechargeable; and CRV batteries are rechargeable. This paper contains the following sections: a brief introduction on CRV requirements, CRV advantages over Soyuz, and X-38 programs; Battery objectives and approach; Battery requirements and groundrules (performance, on-orbit operation, etc); Design trades, solutions, redundancy plan, and margins; Envelope, size, and mass; Interfaces (structural, electrical & thermal); and Deviation from OPS CRV.

Darcy, Eric