Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

X-59 Air Data Probe Calibration Wind Tunnel Test

NASA's aeronautical innovators are working with Lockheed Martin to design and build a supersonic X-plane, the X-59, under the the Low Boom Flight Demonstrator (LBFD) Project, that produces a gentle thump rather than a loud sonic boom. The plane will be used to collect human response data over select U.S. communities. The data from the X-59 test flights will be provided to U.S. and international regulators to potentially allow supersonic flight over land, drastically reducing travel time within the U.S. and around the world. Two wind tunnel tests were conducted in the NASA Glenn Research Center (GRC) 8- by 6-Foot Supersonic Wind Tunnel to calibrate the nose probe for the X-59. The probe was successfully tested and calibrated at 19 Mach numbers between Mach 0.25 and Mach 1.7. Most data were collected using continuous roll angle sweeps at a set Mach number and pitch angle. About 725 high quality data runs were recorded during testing to be used in the calibration of the probe. A backup nose probe was also run through the same test matrix as the primary probe. The probe will be the primary instrument for the flight test of the X-59 for determining angle of attack, angle of sideslip, airspeed, and pressure altitude of the aircraft in flight. Knowing the aircraft's speed and attitude is critical for flight safety and is also critical data for the Sonic Boom mission. Areas of interest for the test were sea level takeoff and landing at Mach 0.2, subsonic cruise at Mach 0.9, and supersonic cruise at Mach 1.4. During Phase I flight testing, the air data nose probe and air data system as a whole will be further calibrated in flight to account for additional installed effects of the airframe on the air data system.

X-59↗

X-59 Air Data Probe Calibration Wind Tunnel Test

NASA's aeronautical innovators are working with Lockheed Martin to design and build a supersonic X-plane, the X-59, under the the Low Boom Flight Demonstrator (LBFD) Project, that produces a gentle thump rather than a loud sonic boom. The plane will be used to collect human response data over select U.S. communities. The data from the X-59 test flights will be provided to U.S. and international regulators to potentially allow supersonic flight over land, drastically reducing travel time within the U.S. and around the world. Two wind tunnel tests were conducted in the NASA Glenn Research Center (GRC) 8- by 6-Foot Supersonic Wind Tunnel to calibrate the nose probe for the X-59. The probe was successfully tested and calibrated at 19 Mach numbers between Mach 0.25 and Mach 1.7. Most data were collected using continuous roll angle sweeps at a set Mach number and pitch angle. About 725 high quality data runs were recorded during testing to be used in the calibration of the probe. A backup nose probe was also run through the same test matrix as the primary probe. The probe will be the primary instrument for the flight test of the X-59 for determining angle of attack, angle of sideslip, airspeed, and pressure altitude of the aircraft in flight. Knowing the aircraft's speed and attitude is critical for flight safety and is also critical data for the Sonic Boom mission. Areas of interest for the test were sea level takeoff and landing at Mach 0.2, subsonic cruise at Mach 0.9, and supersonic cruise at Mach 1.4. During Phase I flight testing, the air data nose probe and air data system as a whole will be further calibrated in flight to account for additional installed effects of the airframe on the air data system.

X-59↗

Efficient Calibration of Expensive Computational Models

Accounting for uncertainty when calibrating expensive computational models is a common challenge faced by scientists and engineers. Often Bayesian techniques are adopted to estimate a probability density function over the model parameters given noisy empirical data. The methods used to perform this type of probabilistic calibration are computationally prohibitive in that they require a large number of evaluations of the expensive model. In these cases, surrogate modeling -- that is, using a fast-to-evaluate, lower fidelity stand-in for the original computational model -- may be the only option to alleviate this computational burden. However, the upfront cost of generating training data to build a surrogate model can itself be expensive. As such, it is important to be judicious when selecting training points at which the full-fidelity model is evaluated. Here, an active learning approach is proposed that enables efficient selection of training points using approximate samples of the calibrated parameter probability density function. In this way, the training points can be concentrated in regions where the calibration algorithm requires high model accuracy.

active learning↗

An Inverse Chance-constrained Approach to the Calibration of Robust Models

This paper proposes a strategy to calibrate computational models according to uncertain input-output data. To this end, uncertainty in the data is first quantified by creating adversarial data sets. Samples drawn from such sets are then mapped from the input-output space to the parameter space using an inverse mapping. This mapping minimizes the collective output spread of an ensemble of point predictions while satisfying a set of individual data-matching requirements. The distribution of the resulting parameter points, which often exhibits strong parameter dependencies, is then modeled using sliced-normals. The chance-constrained formulation used to learn this distribution enables the analyst to trade-off a greater likelihood for most of the data against a lower likelihood for some of the data thereby relaxing the conservatism of the calibrated model. This formulation not only neglects the worst-performing quantiles of each adversarial distribution but also eliminates the potentially serious effects that outliers might have on the resulting model. This calibration approach not only has a considerably lower computational cost than the standard forward approach but it also allows for the identification of suitable distribution classes, which in turn yield better calibrated models.

Calibration↗

Using Scattered Light From Nadir Port to Aid the Terra and Aqua MODIS Reflective Solar Band Calibration

The MODIS instruments on the Terra and Aqua spacecraft employ a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) system to calibrate their reflective solar bands (RSBs), covering a spectral range from 0.4 to 2.1 µm. The UV exposure of the SD, from its sun-view port as well as the scattered light (sunlight reflected from top-of-atmosphere), has led to a wavelength dependent degradation of the SD, with larger degradation observed at shorter wavelengths. The scatter off the diffuser onto the scan mirror is in the forward direction, whereas the scatter off the diffuser onto the SDSM fold mirror is in the backward direction. Since the outgoing angles (viewed by MODIS detectors) are the same as the scheduled SD calibration, the gain derived from scattering light facilitates monitoring the dependence of the SD’s degradation on incident angles. In this paper, we present a method that uses multiple orbits over each mission to obtain a SD response to the nadir port illumination. The SD degradation estimated from the nadir port illumination is compared with the degradation derived from the sun-illuminated SD. As both Terra and Aqua spacecraft continue to drift from their nominal orbits, the SD calibration mechanism has been adapted to these drifts, especially in terms of characterizing the transmission screen function. This paper also presents the utility of this scattering light data to support the RSB calibration in the post-nominal orbit drift era of operations.

MODIS↗

Further Development of the Tamped Richtmyer-Meshkov Instability Method and Application to Molybdenum Dynamic Strength Calibration and Tabulation

The high pressure and high strain rate dynamic strength of Mo is experimentally and computationally investigated in the 3–20 GPa stress, 50–600 C temperature, and 10 5 –10 6 /s strain rate regimes using a modified tamped Richtmyer-Meshkov instability (RMI) method. Modifications to the tamped RMI method include a method to determine loading states during strain, a new strength calibration function based on interface shape, and a robust uncertainty quantification method. These modifications improve fidelity of the tamped RMI method, allowing evaluation of the compensating effects of pressure hardening, strain rate hardening, strain hardening, and thermal softening. The new calibration function based on interface shape is not limited to sinusoidal corrugations and could be applied to additional interface shapes. Plate impact experiments are performed at Argonne National Laboratory’s Advanced Photon Source’s Dynamic Compression Sector operated by Washington State University (DCS), driving a planar shock front through a corrugated Mo-D 2 O or Mo-C 8 F 18 interface, forcing the corrugation to significantly deform. The extent of interfacial deformation, RMI growth, is experimentally observed using X-ray phase contrast imaging at the DCS. RMI jet lengths and jet shapes are extracted from the experimental radiographs, then used to calibrate numerical simulations performed with the Sandia National Laboratories (SNL) hydrocode CTH. Mo yield strength, Y, as a function of shock pressure, P, strain rate, $\dot{\varepsilon }$, accumulated strain, ϵ, relative volumetric compression, RD , and temperature, T , is determined for each impact experiment and presented. The calibrated Mo yield strength values range 1.2–1.8 GPa, with strength generally decreasing as the impact stress increases. This trend is likely caused by thermal softening or strain localization. The tabular yield strength versus loading condition data presented in this paper can be used to fit complex strength models.

Voorhees, T. J. [Sandia National Lab. (SNL-CA), Li↗

Long-term thermal stability and calibration of Type-II fiber Bragg grating array inscribed in radiation-hardened fibers

This paper investigates the long-term thermal stability of Type-II fiber Bragg grating (FBG) arrays, inscribed by femtosecond laser in radiation-hardened fiber, for potential applications as multiplexed sensors in high-temperature energy systems. The thermal stability of FBG sensors was assessed through 16 thermal cycles from room temperature (RT) to 750 ℃ about two months, involving 100 FBG sensors. The results show that the absolute temperature drift of FBG sensors can be reduced to less than 0.4 pm/day after 54 h thermal annealing process at a constant temperature of 800 ℃. As temperature sensors, the FBGs demonstrated stable performance, achieving a standard deviation (STD) of 1.8 pm (corresponding to a temperature resolution of 0.118 ℃) post-annealing. Repeated thermal cycles revealed a random drift of 2.3 pm in the FBG wavelength at RT. Polynomial fitting was explored as a calibration method to convert FBG wavelength shifts into absolute temperature measurements. By optimizing calibration temperature points (RT, 200 ℃, 400 ℃, and 750 ℃), the study shows that cubic polynomial calibration using four points yields an average R2 of 0.9997 and an RMSE of 3.58 ℃ across the entire temperature range (RT to 750 ℃). This approach represents an 11.53-fold improvement over empirical slope calibration and a 1.34-fold improvement over four-point piecewise fitting. The findings indicate that Type-II FBGs inscribed in radiation-hardened fibers can function as accurate temperature sensors, with performance on par with or exceeding that of thermocouples. With their multiplexing capability, robust signal transmission over long lead cables, and immunity to electromagnetic interference, FBG sensors offer a promising alternative to traditional electronic sensors for energy system monitoring.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Calibrating cryogenic temperature of TEM specimens using EELS

Cryogenic Scanning/Transmission Electron Microscopy has been established as a leading method to image sensitive biological samples and is now becoming a powerful tool to understand materials' behavior at low temperatures. However, achieving precise local temperature calibration at low temperatures remains a challenge, which is especially crucial for studying phase transitions and emergent physical properties in quantum materials. In this study, we employ electron energy loss spectroscopy (EELS) to measure local cryogenic specimen temperatures. Here we use the temperature-dependent characteristics of aluminum's bulk plasmon peak in EEL spectra, which shifts due to changes in electron density caused by thermal expansion and contraction. We successfully demonstrate the versatility of this method by calibrating different liquid nitrogen cooling holders in various microscopes, regardless of whether a monochromated or non-monochromated electron beam is used. Temperature discrepancies between the actual temperature and the setpoint temperatures are identified across a range from room temperature to 100 K. This work demonstrates the importance of temperature calibrations at intermediate temperatures and presents a straightforward, robust method for calibrating local temperatures of cryogenically-cooled specimens in electron microscopes.

36 MATERIALS SCIENCE↗

AI Driven Experiment Calibration and Control

One critical step on the path from data taking to physics analysis is calibration. For many experiments this step is both time consuming and computationally expensive. The AI Experimental Calibration and Control project seeks to address these issues, starting first with the GlueX Central Drift Chamber (CDC). We demonstrate the ability of a Gaussian Process to estimate the gain correction factor (GCF) of the GlueX CDC accurately, and also the uncertainty of this estimate. Using the estimated GCF, the developed system infers a new high voltage (HV) setting that stabilizes the GCF in the face of changing environmental conditions. This happens in near real time during data taking and produces data which are already approximately gain-calibrated, eliminating the cost of performing those calibrations which vary ±15% with fixed HV. We also demonstrate an implementation of an uncertainty aware system which exploits a key feature of a Gaussian process.

Britton, Thomas↗

Ex situ calibration of the scattered-light time-history diagnostic on the National Ignition Facility

The scattered-light time-history diagnostic (SLTD) suite measures time-resolved scattered light in three wavelength bands: stimulated Brillouin scattering (350–352 nm), stimulated Raman scattering (430–760 nm), and plasma emission at half the laser frequency (695–735 nm), at 15 locations around the National Ignition Facility (NIF) target chamber. The SLTD, along with the full-aperture backscatter station (FABS), collects scattered light from direct- and indirect-drive inertial confinement fusion experiments. The SLTD calibration was revisited after a discrepancy between FABS and SLTD measurements was observed on NIF polar direct-drive experiments. An integrated calibration of the SLTD was performed for the first time, and individual components were also calibrated for the wavelengths of 351, 527, and 532 nm. The optical transmission of the instrument was measured to be (1.12 ± 0.04) × 10 –7 and (1.96 ± 0.11) × 10 –7 for the wavelengths of 351 and 532 nm, respectively. The revised calibration at 351 nm brings the SLTD measured scattered energy in agreement with the FABS measured scattered energy after additionally accounting for the degradation of an optical element in FABS. Furthermore, this decreased the inferred absorption by 7% for a representative experiment. However, discrepancies remain between FABS and SLTD measurements in the SRS band (532 nm).

47 OTHER INSTRUMENTATION↗

Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates

Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.

Instruments & Instrumentation↗

Weak Lensing Mass Calibration of the ACT DR5 Galaxy Clusters with the DES Year 3 Weak Lensing Data

We use weak gravitational lensing measurements from Year 3 Dark Energy Survey data to calibrate the masses of 443 galaxy clusters selected via the Sunyaev-Zel'dovich effect from Atacama Cosmology Telescope Data Release 5 maps of the cosmic microwave background. We incorporate redshift and SZ measurements for individual clusters into a hierarchical model for the stacked lensing signals and perform Bayesian analyses to constrain the hydrostatic mass bias of the clusters. Our treatment of systematic uncertainties includes a prescription for measuring and accounting for the weak lensing boost factor, consideration of a miscentering effect, as well as marginalization over uncertainties in the source galaxy photometric redshift distributions and shear calibration. The resultant constraints on the normalization of the mass-observable relation have a precision of approximately 7%, with the mean WL halo mass of M $_{500c}$ = 5.4 × 10$^{14}$ M $_{⊙}$. We measure the bias between the true cluster mass and the mass estimated from the SZ signal based on an X-ray-calibrated scaling relation assuming hydrostatic equilibrium, to be 1 - b = 0.74$^{+0.06}$ $_{-0.05}$ over the full sample. When splitting the clusters into high (z = 0.43-0.70) and low (z = 0.15-0.43) redshift bins, we measure 1 - b = 0.58$^{+0.06}$ $_{-0.05}$ and 0.81$^{+0.08}$ $_{-0.06}$, respectively. When introducing additional freedom in redshift and mass to the hydrostatic bias model, we find that 1 - b decreases with redshift (with the power law of -1.8$^{+0.5}$ $_{-0.6}$, 99.95% confidence), consistent with findings from other recent studies, while we do not find any significant trend in mass. We also demonstrate that our result is robust against various systematics such as a scale cut, priors on baryonic and miscentering parameters, and degree of scatter in mass-observable relation. The weak-lensing mass calibration presented in this study will be a useful tool for using the ACT clusters as probes of astrophysics, and as a step towards using their abundance as a cosmological probe.

Shin, T. [Carnegie Mellon U.] (ORCID:0000000263895↗

The design, implementation, and performance of the LZ calibration systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators↗

Electromagnetic energy calibration of the SoLid detector with horizontal muons

SoLid is a neutrino experiment at very-short baselinesearching for active-to-sterile oscillations of reactorantineutrinos. The detection principle is based on the pairing oftwo types of solid scintillators: polyvinyl toluene and $^{6}$Li:ZnS(Ag), which is a new technology used in this field ofPhysics. In addition to good neutron-gamma discrimination, thissetup allows the detector to be highly segmented; the basicdetection unit is a 5 cm cube. High segmentation provides numerousadvantages including precise localisation of the Inverse Beta Decay(IBD) products, the derivation of an antineutrino energy estimatorbased on the isolated positron energy, and a powerful backgroundreduction tool that relies on the topological signature of thesignal. Finally, the system is read out by a network ofwavelength-shifting fibres coupled to photosensors. A relativeelectromagnetic calibration is performed with horizontal cosmicmuons. This source poses the simplest calibration problem in which asingle detection unit is involved. In addition, large muon energydeposits allow us to perform a calibration at the most detailedlevel (i.e. per fibre) and to accurately define the fraction ofenergy escaping to neighbouring detection cells. A statisticalprecision at the sub-percent level is reached. The paper alsodiscusses two methods to calibrate the absolute energy scale andpresents their implementation and results. The first method relieson horizontal muons, though the precision is limited to around 10%because of the uncertainty in the energy distribution of suchmuons. A novel, alternative method based on the radioactiveamericium-beryllium source is proposed. It takes advantage of theelectron-positron pair-production process and provides a calibrationpoint at 3.4 MeV (i.e. in the core of the IBD positronspectrum). The paper is concluded with various cross-check includinga determination of the energy spectrum of the standard cosmogenicbackground candle: $^{12}$B.

Abreu, Y. [Antwerp U.]↗

Deep-field analytical calibration

The next generation of imaging surveys, including the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST), Euclid, and the Nancy Grace Roman Space Telescope, will provide unprecedented constraints on cosmology using weak gravitational lensing. To fully exploit this statistical power, shear measurement methods must achieve sub- per cent accuracy while mitigating systematic biases from noise, the point-spread function (PSF), blending, and shear-dependent detection. The analytical calibration framework (AnaCal) has demonstrated such accuracy but requires adding noise to images, reducing effective depth. We introduce Deep-Field Analytical Calibration (DEEP-FIELD AnaCal), an extension of AnaCal that uses deep-field images to compute shear responses while preserving the statistical power of wide-field data. We validate DEEP-FIELD AnaCal on isolated and blended galaxy image simulations with LSST-like conditions, finding it meets the stringent requirement of multiplicative bias $|m| < 3\times 10^{-3}$ at 99.7 per cent confidence. Compared to standard AnaCal applied to wide-field images, DEEP-FIELD AnaCal increases the effective galaxy number density from 17 to 30 arcmin$^{-2}$ for simulated 10-yr LSST data. With deep fields $10\times$ longer than the wide field, we find pixel noise variance in shear estimation is reduced by 30 per cent and overall uncertainty by $\sim 25~{{\ \rm per\ cent}}$. Finally, using the LSST Deep Drilling Fields strategy, we assess sample variance and find an equivalent calibration uncertainty of $\lesssim 0.3~{{\ \rm per\ cent}}$. These results demonstrate that DEEP-FIELD AnaCal offers a promising path to achieve the required shear calibration for upcoming weak lensing surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. Here, we demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inverter Model Validation and Calibration Using Phasor Measurement Unit Data

As the penetration of inverter-based renewable energy resources increases in the power grid, especially at the distribution and microgrid levels, the need to accurately represent them in planning studies increases as well. However, due to the lack of well-established standard procedures, and vendor reluctance towards the detailed sharing of proprietary models, automated dynamic model validation and parameter calibration tools for inverter based resources (IBRs) remain scarce. This work presents a model validation and parameter calibration platform for representing IBRs with generic phasor-domain models. Phasor measurements of power system events are used for continuous validation using the data playback method, and model parameters are re-calibrated if a significant mismatch between measurements and model response is observed. Unique features of the proposed platform include- (a) an iterative Bayesian optimization approach towards parameter calibration to address a possible mismatch between the structures of generic models implemented in simulation softwares and actual commercial inverters, (b) error metrics designed to account for a possible mismatch between the time resolution of simulation and measurements, and (c) analysis of the measurement-simulation mismatch to provide guidance to engineering personnel regarding model shortcomings. The performance of the platform has been illustrated using both simulated data and field measurements to validate/calibrate inverter models in GridLAB-D.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗