Impact of Hybrid Energy Storage System (HESS) Topologies on Performance: Exploration for Hydropower Hybrids

We investigate the technical performance of six HESS topologies integrated with run-of-river (ROR) hydropower to provide frequency support. We choose ROR hydropower because there are 23 GW of installed ROR hydropower in the U.S. and integrating these plants with energy storage could boost their contribution to grid services. We focus on HESSs composed of batteries and ultracapacitors because batteries are cost effective for storing energy but degrade more quickly as a function of cycling. In contrast, ultracapacitors can be cycled millions of times and are cost effective for quick injections of power. We find that active HESS topologies demonstrate the best overall improvement to grid frequency during a contingency while adhering to the power ramping limits of the HESS devices. Future work will investigate other services to identify if one HESS topology performs best for all services of interest or, more likely, different HESS topologies are best suited for specific services.

13 HYDRO ENERGY↗

Impact of Wide-Area Oscillation Damping Control using Measurement-Driven Approach on System Separation - Saudi Grid Case Study

In any interconnected power grid, low-frequency oscillations is a major problem that can limit the power transfer capability and deteriorate power system security due to potential low-damped or even undamped oscillations. Synchronized measurements provided by PMUs enable the design and development of wide-area oscillation damping controllers (WADC) based on measurement-driven model to overcome the limitations of traditional controllers. This work focuses on the impact of a W ADC based on a measurement-driven approach on system separation for the Saudi Electricity Company (SEC) grid. A grid model is provided by SEC for this study. Modal analysis is performed to identify the oscillation mode of interest for which the controller is designed. Damping the dominant oscillation mode helps slightly to improve transient stability of the system. Considering bus frequency at different locations in SEC's system as the candidate observation signals, the optimal observation signal is chosen for the W ADC by using the FFT method. The system transfer function model is constructed by utilizing probing measurements. Then, the W ADC parameters are calculated based on the identified model. The performance of the designed W ADC is tested under different contingencies.

Altarjami, Ibrahim↗

Closure Strategy for Operable Unit III of the Monticello Mill Tailings Site

Multiple strategies and scenarios were evaluated to advance Operable Unit (OU) III of the Monticello Mill Tailings Site (MMTS) towards closure. MMTS is a former mill site that was used to process uranium and vanadium ore in southeastern Utah until 1960. Uranium is the primary contaminant of concern in OU III, which includes surface water in Montezuma Creek and groundwater present in a shallow alluvial aquifer along the creek valley for several miles downgradient of the former mill site. Surface remedial actions were completed in 2000. In 2004, the selected final remedy was monitored natural attenuation (MNA) and institutional controls, and a pump-and-treat system installed in the highest-concentration area as a contingency remedy. The pump-and-treat system was expanded in 2015, and average uranium concentrations have declined locally over time. However, monitoring data and column studies suggest that the system effectiveness will continue to decrease over time. Three closure strategies were considered: restoration of MNA; alternate concentration limits; and a technical impracticability (TI) waiver. The preferred closure strategy is to restore MNA and maintain institutional controls, without active remediation. The strategy includes demonstrating criteria for MNA acceptance, pump-and-treat termination, long-term monitoring, and eventual site delisting. Several potential scenarios for transitioning to the preferred closure strategy were identified. Recommended actions over the next few years include updating the conceptual site model, conducting numerical modeling to predict remedial performance and time frames, geochemical analyses to assess uranium transport, and summarizing the lines of evidence and basis for MNA.

remediation, uranium, groundwater, monitored natur↗

A Two-Step Restoration Scheme with DER Controllability for Resilient Distribution Systems

Modern distribution systems have increasing integration of distributed energy resources (DERs). A large number of distribution system DERs are interfaced through a power electronic converter. During grid contingency scenarios these resources have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid's restoration after an adverse event and hence enhancing resilience. In distribution systems, system restoration is an important problem, especially in face of high-impact low-frequency events. This paper proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in DERs for mitigating voltage problems. Simulation studies are performed on the IEEE-123 node feeder system to demonstrate the effectiveness of the proposed method for various cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Towards Learning-Based Architectures for Sensor Impact Evaluation in Building Controls

Advanced control algorithms for building systems are known to have significant potential in reducing energy consumption while optimizing thermal comfort. The success of such algorithms is critically contingent on several different types of sensor systems, which are in turn, used for continuous monitoring, identification and estimation of several important building states, such as temperatures, humidity, air quality, power consumption and occupancy status. Nonidealities in any of these sensors can lead to significant performance degradation of the control functionalities, and may lead to unwanted sub-optimal building operation. In this paper, we provide a simulation example with a high-fidelity building model, for a particular use-case of advanced optimization-based control in buildings, i.e., occupancy-based controls. We show how imperfections in occupancy sensing can offset performance. Subsequently, we discuss a novel learning-based architecture to efficiently evaluate the impact of sensor nonidealities for building systems, in context of advanced control algorithms.

Bhattacharya, Saptarshi↗

Smart Planning Support for Nuclear Power Plant Work Planners

Operation and Maintenance costs of a nuclear power plant account for 60% of overall plant costs due to the nuclear industry?s risk-adverse culture (World Nuclear Association, 2020). The industry relies on highly conservative estimates to avoid risk and brute force reactions to manage the unexpected and keep a plant running safely. This approach has kept plants operating safer than any other power source available over the last six decades (Ritchie, 2020). However, these conservative methods have cost the nuclear industry in market competitiveness. The solution? Transform the conservative approaches to accurate, efficient, and still safe data-driven approaches that leverage advanced technologies available in the digital age of operation. This project endeavored to identify two key aspects to successfully incorporate historical work execution data. First, where in the work management process is that information most pertinent? Next, what variables are key to informing the best strategy for organizing the upcoming work? The Smart Planner uses data collected by dynamic work instructions to provide a basis for suggesting requirements of similar, upcoming work packages. Further, it curbs inefficiencies of the work management process by analyzing the likelihood of discovery work, offering suggestions to build a contingency package. All this taking place as the work planner builds work packages that meet the predetermined scope of work to be performed.

99 GENERAL AND MISCELLANEOUS↗

Simulating Impacts of Extreme Events on Grids with High Penetrations of Wind Power Resources

As extreme weather events become more frequent and intense, the demand for connecting grid operation and infrastructure planning with extreme event models will increase as well. We present a methodology for creating damage contingencies and scenarios for electric transmission grids during a hurricane strike. Included is an example case study: Hurricane Dolly damaging a synthetic 2000 bus test system during its landing in Southern Texas. Using WIND Toolkit meteorological data in conjunction with fragility curves for various electric grid elements, we generate stochastic damage scenarios that can be used for short- and long-term planning problems including emergency asset management. We perform statistical analysis of damages and quantify topological effects on example synthetic grid. Also, we investigate loss-of-load events during two-day economic dispatch experiment. Finally, we point out various shortcomings of our method and suggest how it can be improved.

data-driven forecasting↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation

This presentation discusses the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., the loss of a large generation unit). This NLM engine is particularly important for microgrid systems because it provides a high-speed, cost-optimal control solution to coordinate grid-forming inverters and to dispatch grid-following inverters and deferrable loads in microgrid systems to enhance grid resilience and reliability. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm with two sequential contingency events of lost generation units. The experimental results indicate that the NLM engine can maintain system stability, achieve the targeted system voltage and frequency, and balance load and generation to serve the critical facility with improved system resilience and reliability.

droop control↗

Transmission-Distribution Dynamic Co-Simulation of Electric Vehicles Providing Grid Frequency Response: Preprint

This paper investigates the impacts of electric vehicles (EVs) on power system frequency regulation based on an open-source transmission-and-distribution (T&D) dynamic co-simulation framework. The development of a EV dynamic model based on appropriate WECC dynamic model is introduced first, then the T&D dynamic co-simulation platform is described. The advantage of the overall platform is that DERs such as distributed photovoltaic (DPV) and EV are modeled explicitly in both transmission and distribution simulators for frequency dynamics and voltage, respectively. In the case studies, EVs frequency responses (i.e., primary and/or secondary) are simulated after the system is exposed to N-1 contingency such as a generation trip. Various EV frequency regulation participation strategies are investigated as well to study their impacts on system frequency response. The studies shows that EVs have potential capability to provide effective frequency regulation services.

electric vehicle↗

Assessing the Technical Potential of Fast Frequency Response in Grid-Supportive Loads

Fast frequency response (FFR) is a critical tool for grid operators to manage contingency events in low-inertia systems. While large generators and loads are more commonly used, many smaller end use loads, in aggregate, can provide FFR across a large system. This work considers the technical potential of power electronics-based loads for autonomous FFR in low-inertia grids. We consider multiple factors that might influence the impact of FFR for various end use loads, with a focus on residential loads.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems: Preprint

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

Quarterly Management Document – FY22, 3rd Quarter, Multi-pass Hybrid Laser Arc Welding of Alloy 740H

During the 3rd quarter of FY22, progress was made on modeling and simulation of deep penetration laser welding of Alloy 740H. Advances in the modeling of residual stress development arising from the calculated temperature field of the solidifying weld pool were made to understand the development of solidification cracking. Additionally, preliminary modeling of the temperature field within the weld pool of a wobbling laser heat source was performed. The maximum temperature of the weld pool was found to vary with time. These result will allow modeling of deep penetration laser welding using a wobbling laser to mitigate weld defects and cracking. Also, additional characterization of hybrid laser arc welds indicated that these welds were not defect-free as originally thought and the current HLA welds would not be acceptable under criteria outlined in the ASME Boiler and Pressure Vessel Code, Section IX. Therefore, additional welding trails with variation of the welding parameters and HLA welding configurations are required to produce welds acceptable under the Section IX criteria. It was shown that considerable reduction of HLAW defects had been achieved with each successive welding campaign. Therefore additional variation of HLAW parameters may still yield the desired defect-free welds, however, options for alternate HLAW configurations as well as plate preheating are outlined as contingency plans to obtain suitable welds. These additional (unplanned) HLAW trial may prevent subsequent milestones from being achieved within the original budget.

36 MATERIALS SCIENCE↗

Study of Inverter Control Strategies on the Stability of Low-Inertia Microgrid Systems

This paper investigates the stability of low-inertia microgrid systems with two control strategies that have different percentages of grid-forming (GFM) inverters. The first control strategy has approximately 50% GFM inverters, and all the battery inverters are working in GFM control mode. Originally, the second control strategy has approximately 10% GFM inverters, with only two battery inverters working in GFM control mode and the rest working in grid-following (GFL) PQ control mode based on current control, which cannot stabilize the microgrid system. Then, the second control strategy is modified to change the GFM inverters from droop control to isochronous control and the GFL battery inverters from traditional current control to voltage control for power control. Both control strategies can maintain system stability; however, the first control strategy can better handle contingency events. The study indicates that 1) a microgrid system with a higher percentage of GFM inverters has better stability; and 2) a microgrid with a lower percentage of GFM inverters can have poor stability, but improved control strategies in inverters can improve system stability. This study improves the understanding of how different percentages of GFM inverters and inverter control strategies affect the system stability of low-inertia microgrids.

droop control↗

Impact of Open Communication Networks on Load Frequency Control with Plug-in Electric Vehicles by Cyber-Physical Dynamic Co-Simulation: Preprint

With the increasing electrification of the transportation sector, vehicle to grid (V2G) control technologies are promising to improving system frequency stability. However, these control technologies might require non-traditional communication supports. This paper investigates the impacts of electric vehicles (EVs) V2G on power system frequency regulation considering communication variations through transmission-distribution-communication (TDC) dynamic simulation. The simulation model is built based on our previously developed open-source transmission-and-distribution (T&D) dynamic co-simulation framework. Here, we add the communication variation functions (i.e. delay and packet loss) to complete the TDC simulation framework. In the case studies, practical communication variation scenarios are considered when the system experiencing an N-1 generation trip contingency. The considered scenarios include communication delay and packet loss using both homogeneous and heterogeneous assumptions. The delay and packet loss rate are the same in all communication channels in the homogeneous case but varies in the heterogeneous case. The results show the communication delay has an obvious impact on the frequency recovery compared to the communication packet drop. The impacts of the standard deviations of communication delay time and packet drop rate are not significant. The outcomes of this work can help improve the EV frequency regulation services and provide robust and effect supports to the grid.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

FECM/NETL Unconventional Shale Well Economic Model (UShWEM)

FECM/NETL Unconventional Shale Well Economic Model (UShWEM) is an Excel-based model that evaluates the economics of an unconventional shale well on a per-well and per-pad basis. The model calculates the net cash flow, internal rate of return (IRR), net present value (NPV), earnings before interest, taxes, depreciation, and amortization (EBITDA), payout month and year, and breakeven price (for either oil- or gas-wells). The model can be used to estimate the economics of a well or pad over its lifetime (development through site reclamation) based on (1) the capital and operating costs associated with well/pad development and operations, (2) the revenue associated with oil, gas, and condensate production streams, and (3) accounting for relevant tax policies and asset depreciation applicable for oil and gas operations. The main input for the model is the completion design and production data. Key financial considerations in the model include oil, gas, and condensate market prices, tax-related settings, royalty rates, the discount rate, minimum economic hurdle (IRR) [if performing break-even analysis], and project contingency. The financial consideration can be adjusted to reflect the level of granularity the user requires as input when calculating the economics for a well or pad development. In addition, the model affords users the option to provide their user inputs for all cost categories considered. As a result, the model can be used to generate a multitude of scenario cases for sensitivity analysis of the various financial considerations, as well as production and cost profiles. To make this seamless, the model has the capability for key economic outputs to be exported in large batches through macros-enabled functions on its “Model Output Summary” and “Multi-Well Cost Analysis. The spreadsheet model includes macros and user-defined functions, so the user must enable Excel’s macro capability for the model to function correctly.

Sheriff, Alana↗

A Unified Metric for Fast Frequency Response in Low-Inertia Power Systems: Preprint

Future power system with more inverter-based resources (IBRs) is vulnerable to the frequency-decline contingency. Fast frequency response (FFR) provided by IBRs is a good candidate to arrest the frequency excursion. Diverse types of FFRs have been integrated into the power system. Without a unified quantification of FFRs, it is hard for the grid operators to fully leverage the FFR capabilities of IBRs. This work introduces potential unified metrics of prevailing FFRs. We utilized the metric-to-frequency (M2F) mapping to validate the accuracy of the metrics. The results show the proposed metric to be simple yet accurate.

effective inertia↗

Cyber risk assessment and investment optimization using game theory and ML-based anomaly detection and mitigation for wide-area control in smart grids

The electric power grid is increasingly becoming susceptible to cyber attacks that exploit vulnerabilities in the smart grid control, information, and physical layers. Successful cyber attacks can have catastrophic impacts on the social and economic well-being of any nation all over the globe. It has, thus, become imperative to secure the smart grid against such adversarial actions to ensure stable, secure, and reliable operation of the grid. The existing research and industry practices prove to be inadequate in terms of providing pragmatic and effective defense methodologies and measures for long-term cybersecurity planning and real-time cybersecurity for grid operation. For example, existing works lack models that incorporate uncertain behavior of cyber-attackers and pragmatic defense measures for cyber risk assessment and cybersecurity investment optimization which often provide unreliable and strictly qualitative solutions to these problems. At the same time, with the growing number of cyber incidents in the grid, there still exists a need to develop attack-resilient algorithms for wide-area monitoring, protection, and control (WAMPAC) applications like the wide-area voltage control systems (WAVCS) for Flexible AC Transmissions Systems (FACTS) that lack in scalable and feasible solutions from the cybersecurity perspective. This dissertation proposes novel models and methodologies for: (1) Cybersecurity planning, and (2) Cybersecurity for system operation. The cybersecurity planning is achieved through cyber risk assessment and cybersecurity resource investment optimization for long-term cybersecurity of the grid using game theory and attack-defense trees. Cybersecurity for system operation consists of development of cyber anomaly detection and mitigation algorithms for flexible AC transmission system (FACTS) controller-based wide-area voltage control systems (WAVCS) using machine learning (ML), and software defined networking-based moving target defense network routing for achieving real-time cyber-physical security for grid operations. This is followed by hardware-in-the-loop (HIL) implementation and evaluation of these attack prevention, detection, and mitigation algorithms and methodologies showcasing their feasibility in a close to real-world environment. For cybersecurity planning, a novel approach involving a combination of game theory and attack defense trees (ADT) for optimal cybersecurity resource allocation in the smart grid is proposed. This methodology involves modeling of the cyber-physical smart grid substations as ADTs, defining attacker costs, defense costs, and attack probabilities for attack access points. Using game theoretical formulation, optimal defense strategies for the defender of the system to invest cybersecurity resources in the grid are obtained. Additionally, a game-theoretic framework is developed for quantitative cyber-physical risk assessment of the grid under a dynamically changing cyber threat space and uncertain behavior of cyber attackers which is further used to optimize investments in the smart grid's cybersecurity resources. The attacker, defender, and the smart grid system are modeled while incorporating attacker-stochasticity and federal guidelines for smart grid cybersecurity. This allows quantification of threat, vulnerabilities, and attack impact of the grid for quantitative risk assessment. The defender's budget to invest in the security resources in the grid is optimized based on the strategies leading to minimum system risk. The evaluation of the proposed solutions highlight the feasibility for practical implementation of these methodologies and algorithms in the smart grid, while taking the federal requirements and guidelines for smart grid security into consideration. For achieving cybersecurity for system operation, attack prevention, detection, and mitigation algorithms and methodologies are developed specifically for FACTS-based WAVCS. Anomaly detection and mitigation in the WAVCS are achieved using algorithms based on machine learning which involves offline training and testing of ML models with CPS datasets incorporating physics-based features that allow accurate distinction between system faults and cyber attacks. For attack prevention, a methodology based on software defined network (SDN)-based moving target defense (MTD) network routing is proposed that enables prevention of Denial of Service (DoS) type attacks on the smart grid communication system. Subsequently, these methodologies and algorithms are implemented and evaluated on an HIL testbed that allows for real-time attack prevention, detection, and mitigation of emulated cyber attacks on the WAVCS in a close to real-world environment. The results show highly accurate and efficient performance of the implemented algorithms and methodologies with the smart grid system operating within the NERC's system operation limits even in the presence of DoS and data integrity cyber attacks. This work opens up future research opportunities in other directions such as (1) Expanding cybersecurity planning methodologies to real-time cyber contingency analysis with different game formulations; and (2) Applying the cybersecurity for system operation algorithms to broader categories of wide-area control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Constraint Violations as a Result of Ambient Adjusted Transmission Line Ratings

Ambient Adjusted Ratings allow transmission line current ratings to be increased above static ratings while requiring minimal weather monitoring. However, Ambient Adjusted Ratings are still contingent on static parameters that may not match real world conditions. This poster examines how simulation methods can estimate the extent to which using Ambient Adjusted Ratings could result in the violation of a transmission line's thermal constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗