Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Design of a heat pipe governed thermal control system for the Solar Electric Propulsion Stage /SEPS/

A 2200-w capacity spacecraft heat rejection system designed for the SEPS and utilizing heat pipe radiator panels has been investigated. The total thermal control system consists of two radiator panels connected to the heat source by variable conductance heat pipes (VCHP's). The system was designed to operate in the 223 to 333 temperature range. The radiators have an emittance of 0.88 at their operational temperature and a fin efficiency of approximately 80 percent. The radiators are thermally isolated from the SEPS and environment by multilayer insulation and thermal shields. Butane was selected as the working fluid for the VCHP because of its low freezing point (135), which is necessary to prevent diffusion freezeout of the liquid during the cold outbond missions. Helium was selected for the control gas. This paper describes the VCHP system, discusses the system design parameters and presents the results of the analyses.

Ruttner, L. E.↗

Heat Pipe Technology: A bibliography with abstracts

This bibliography lists 149 references with abstracts and 47 patents dealing with applications of heat pipe technology. Topics covered include: heat exchangers for heat recovery; electrical and electronic equipment cooling; temperature control of spacecraft; cryosurgery; cryogenic, cooling; nuclear reactor heat transfer; solar collectors; laser mirror cooling; laser vapor cavitites; cooling of permafrost; snow melting; thermal diodes variable conductance; artery gas venting; and venting; and gravity assisted pipes.

Source record↗

Heat pipes for spacecraft temperature control: An assessment of the state-of-the-art

Various heat pipe temperature control techniques are critically evaluated using characteristic features and properties, including heat transport capability, volume and mass requirements, complexity and ease of fabrication, reliability, and control characteristics. Advantages and disadvantages of specific approaches are derived and discussed. Using four development levels, the state of-the-art of the various heat pipe temperature control techniques is assessed. The need for further research and development is discussed and suggested future efforts are projected.

Kirkpatrick, J. P.↗

Prediction of cryogenic heat pipe performance

A 304 stainless steel heat pipe with slab type capillary structure and nitrogen as the working fluid was studied in the temperature range of 60 K to 120 K. The pipe was 1.27 cm in outside diameter and 9.14 cm in total length. In the transient studies, described in detail in this report, saddles were included at evaporator and condenser ends and a radiator was included at the condenser end.

Colwell, G. T.↗

Design and analysis of a cryogenic variable conductance axial grooved heat pipe

An investigation to adapt axial grooved designs to the gammit of heat pipe thermal control techniques, with particular emphasis on those suited for cryogenic applications was conducted. In addition to considering both active and passive gas control, diode designs utilizing liquid or gas blockage, or a liquid trap, are evaluated. The use of the liquid trap as a secondary heat pipe for forward mode operation during diode shutdown is also studied. This latter function is basically that of a thermal switch. Finally, a system capable of hybrid functions consisting of gas-controlled variable conductance and liquid trap diode shutdown or thermal switching is defined.

Source record↗

Thermal Analysis of Axially Grooved Heat Pipes

The liquid viscous drag and the evaporator film coefficient were determined analytically for a heat pipe with axial rectangular grooves under zero-g conditions. The liquid pressure drop and the evaporator film coefficient for an axially grooved heat pipe were found to be expressed by the functions of the meniscus angle, which makes it possible to predict its performance analytically. The performance near its capillary pumping limit is influenced by the contact angle.

Kamotani, Y.↗

Heat pipes for spacecraft temperature control: An assessment of the state-of-the-art

Spacecraft applications that require the efficient cooling of high-powered components, the precise temperature control of sensitive electronic and optical components, and the protection of cooled components from temporary, adverse environmental conditions are increasing. Heat pipes using gas, vapor, liquid, or voltage control to provide variable conductance or diode thermal behavior have been and are continuing to be developed to meet increasingly difficult requirements. The various control techniques are critically evaluated using characteristic features and properties, including heat transport capability, volume and mass requirements, complexity and ease of fabrication, reliability, and control characteristics. As a result, advantages and disadvantages of specific approaches are derived and discussed. Using four development levels, the state-of-the-art of the various heat pipe temperature control techniques is assessed.

Groll, M.↗

Analysis of axially grooved heat pipe condensers

In an analytical study of the thermal behavior of the condenser section of a heat pipe with axial rectangular grooves under zero-g condition, the condensation rate was determined by studying the motion of the thin liquid film on the land area between grooves. It was found that the local condensation rate depends, among other factors, on the curvature of the liquid meniscus and on the shape of the land top. Computed overall heat transfer rate compares favorably with available experimental data. The liquid meniscus variation along the heat pipe length in the condenser section was also determined.

Kamotani, Y.↗

Graded-porosity heat-pipe wicks

To maximize the capacity of a nonarterial heat pipe, a wick is considered whose porosity is allowed to vary axially along its length. At every axial location the porosity is set no lower than required to maintain the wick in a nearly saturated state under the maximum heat-transport rate. The result is a wick whose permeability is everywhere as high as possible. The differential equation that governs the optimum porosity variation is solved numerically between a condenser-end boundary condition that just prevents a liquid slug or puddle in the vapor spaces and an evaporator-end boundary condition that just prevents circumferential groove dry-up. Experimental performance measurements for an ammonia heat pipe are presented.

Eninger, J. E.↗

Flight data analysis and further development of variable-conductance heat pipes

The work focuses on the mathematical modeling of three critical mechanisms of heat-pipe operation: (1) the effect that excess liquid has on heat-pipe performance; (2) the calculation of the dryout limit of circumferential grooves; (3) an efficient mathematical model for the calculation of the viscous-inertial interaction in the vapor flow. These mathematical models are incorporated in the computer program GRADE II, which is described.

Eninger, J. E.↗

Development of a curved pipe capability for the NASTRAN finite element program

A curved pipe element capability for the NASTRAN structural analysis program is developed using the NASTRAN dummy element feature. A description is given of the theory involved in the subroutines which describe stiffness, mass, thermal and enforced deformation loads, and force and stress recovery for the curved pipe element. Incorporation of these subroutines into NASTRAN is discussed. Test problems are proposed. Instructions on use of the new element capability are provided.

Jeter, J. W., Jr.↗

Development of a thermal diode heat pipe for cryogenic applications

The paper describes the development of a cryogenic thermal diode heat pipe for space flight applications. The diode has ethane working fluid, and uses the liquid blockage technique with an internal blocking orifice, to accomplish shutoff in the reverse mode. The pipe is 0.635 cm OD by 75.82 cm long including a 2.54 cc excess liquid reservoir. Experimental data are presented for forward mode throughput vs tilt, film coefficients, and reverse mode characteristics. Transport capacity is 1000 w-cm at 2.5 cm tilt. Evaporator and condenser film coefficients were 0.92 and 1.64 w/sq cm K, respectively.

Quadrini, J. A.↗

Investigation of counterflow shear effects in heat pipes

The entrainment-shear performance limit in heat pipes is investigated. The entrainment heat flux limit is defined as the condition where the Weber number is greater than or equal to one. In this analysis, the critical value for the entrainment Weber number is between 2pi and 3pi. Performance degradation due to vapor-liquid shearing stress is predicted. Preliminary qualitative experiments were conducted to observe the shear stress wave formation phenomena. The equations presented may be used to predict and minimize the vapor-liquid shear stress performance effects in axial groove and puddle flow artery heat pipes.

Feldman, K. T., Jr.↗

The multistage heat pipe radiator - An advancement in passive cooling technology

Mathematical models were developed for one-, two-, and three-stage radiator systems to determine optimum stage areas and system performance as a function of such parameters as insulation effectiveness, cold stage temperature, and heat load to the cold and intermediate stages. This study shows that multistage radiator systems can be optimized on the basis of weight or projected area, and that cold stage temperatures as low as 15 K are theoretically possible with present technology levels for insulation emittance. For the baseline design, analyses were performed to determine optimum radiator fin geometry and heat pipe spacing as a function of temperature, material properties, and heat pipe weight. In addition, a ground test system was designed for the baseline design with heat rejection requirements of 10 MW at 35 K on the cold stage and 100 MW at the second stage.

Wilson, D. E.↗

Axially grooved heat pipes - 1976

This paper summarizes the 'state-of-the-art' of axially grooved heat pipes. Applications are identified and the related heat pipe design and performance are defined. Recent developments in the analysis, design and fabrication of axially grooved hardware are also discussed. A mathematical model which predicts the hydrodynamic behavior and accounts for liquid recession, liquid/vapor shear interaction and 1-g puddle flow is also presented. Performance data for various fluids in the 100-500 K range is compared to predictions from the Groove Analysis Program (GAP). Finally, a simplified closed form solution which accounts for gravity effects, self-priming and composite pumping by the grooves as well as all of the hydrodynamic losses is also discussed.

Brennan, P. J.↗

Flutter of articulated pipes at finite amplitude

The plane motion of an articulated pipe made of two segments is examined and the flow velocity at which flutter manifests itself is sought. The pressure in the reservoir feeding the pipe is kept constant. In contrast to previous works, the flow velocity is not taken as a prescribed parameter of the system but is left to follow the laws of motion. This approach requires a nonlinear formulation of the problem and the equations of motion are solved using Krylov-Bogoliubov's method. A graph of the amplitude of the limit cycles, as a function of the fluid-system mass ratio, is presented and conclusions are drawn as to the necessity of considering nonlinearities in the analysis.

Rousselet, J.↗

Gravity flow rate of solids through orifices and pipes

Lock-hopper systems are the most common means for feeding solids to and from coal conversion reactor vessels. The rate at which crushed solids flow by gravity through the vertical pipes and valves in lock-hopper systems affects the size of pipes and valves needed to meet the solids-handling requirements of the coal conversion process. Methods used to predict flow rates are described and compared with experimental data. Preliminary indications are that solids-handling systems for coal conversion processes are over-designed by a factor of 2 or 3.

Gardner, J. F.↗

Accelerated life tests of specimen heat pipe from Communication Technology Satellite (CTS) project

A gas-loaded variable conductance heat pipe of stainless steel with methanol working fluid identical to one now on the CTS satellite was life tested in the laboratory at accelerated conditions for 14 200 hours, equivalent to about 70 000 hours at flight conditions. The noncondensible gas inventory increased about 20 percent over the original charge. The observed gas increase is estimated to increase operating temperature by about 2.2 C, insufficient to harm the electronic gear cooled by the heat pipes in the satellite. Tests of maximum heat input against evaporator elevation agree well with the manufacturer's predictions.

Tower, L. K.↗