At least 757 records · Page 42

Multi-level Hybrid Cache: Impact and Feasibility

Storage class memories, including flash, has been attracting much attention as promising candidates fitting into in today's enterprise storage systems. In particular, since the cost and performance characteristics of flash are in-between those of DRAM and hard disks, it has been considered by many studies as an secondary caching layer underneath main memory cache. However, there has been a lack of studies of correlation and interdependency between DRAM and flash caching. This paper views this problem as a special form of multi-level caching, and tries to understand the benefits of this multi-level hybrid cache hierarchy. We reveal that significant costs could be saved by using Flash to reduce the size of DRAM cache, while maintaing the same performance. We also discuss design challenges of using flash in the caching hierarchy and present potential solutions.

99 GENERAL AND MISCELLANEOUS↗

Optimal energy storage portfolio for high and ultrahigh carbon-free and renewable power systems

Achieving 100% carbon-free or renewable power systems can be facilitated by the deployment of energy storage technologies at all timescales, including short-duration, long-duration, and seasonal scales; however, most current literature focuses on cost assessments of energy storage for a given timescale or type of technology. In this work, we use an optimization framework with high spatial and temporal resolution to simultaneously assess the variable renewable power deployment and the optimal storage portfolio for seven independent system operators in the United States. Results indicate that achieving high (75–90%) and ultrahigh (>90%) energy mixes requires combining several flexibility options, including renewable curtailment, short-duration, long-duration, and seasonal storage. For instance, carbon-free and renewable energy mix targets of up to 80% are achieved with economic curtailment and a combination of short- and long-duration energy storage for the performance and cost assumptions used. After that, there is a point between 80% and 95% where seasonal storage becomes cost-competitive, depending on the specific power system. Moreover, our results indicate that storage-to-storage operation—one storage device used to charge another storage device—and the decoupling of charging and discharging storage power capacity are cost-effective options for the integration of high and ultrahigh shares of carbon-free or renewable power sources. Additionally, the results from this study show that an 85% carbon-free or renewable energy mix can be achieved at a cost of avoided CO 2 emissions of US$66.0 per tonne or less, regardless of the power system.

25 ENERGY STORAGE↗

An emerging network storage management standard: Media error monitoring and reporting information (MEMRI) - to determine optical tape data integrity

Sophisticated network storage management applications are rapidly evolving to satisfy a market demand for highly reliable data storage systems with large data storage capacities and performance requirements. To preserve a high degree of data integrity, these applications must rely on intelligent data storage devices that can provide reliable indicators of data degradation. Error correction activity generally occurs within storage devices without notification to the host. Early indicators of degradation and media error monitoring 333 and reporting (MEMR) techniques implemented in data storage devices allow network storage management applications to notify system administrators of these events and to take appropriate corrective actions before catastrophic errors occur. Although MEMR techniques have been implemented in data storage devices for many years, until 1996 no MEMR standards existed. In 1996 the American National Standards Institute (ANSI) approved the only known (world-wide) industry standard specifying MEMR techniques to verify stored data on optical disks. This industry standard was developed under the auspices of the Association for Information and Image Management (AIIM). A recently formed AIIM Optical Tape Subcommittee initiated the development of another data integrity standard specifying a set of media error monitoring tools and media error monitoring information (MEMRI) to verify stored data on optical tape media. This paper discusses the need for intelligent storage devices that can provide data integrity metadata, the content of the existing data integrity standard for optical disks, and the content of the MEMRI standard being developed by the AIIM Optical Tape Subcommittee.

Podio, Fernando↗

Bacteriorhodopsin films for optical signal processing and data storage

This report summarizes the research results obtained on NASA Ames Grant NAG 2-878 entitled 'Investigations of Bacteriorhodopsin Films for Optical Signal Processing and Data Storage.' Specifically we performed research, at Texas Tech University, on applications of Bacteriorhodopisin film to both (1) dynamic spatial filtering and (2) holographic data storage. In addition, measurements of the noise properties of an acousto-optical matrix-vestor multiplier built for NASA Ames by Photonic Systems Inc. were performed at NASA Ames' Photonics Laboratory. This research resulted in two papers presented at major optical data processing conferences and a journal paper which is to appear in APPLIED OPTICS. A new proposal for additional BR research has recently been submitted to NASA Ames Research Center.

Walkup, John F.↗

Assessment of Opportunities for New United States Pumped Storage Hydroelectric Plants Using Existing Water Features as Auxiliary Reservoirs

In this assessment of opportunities for new pumped storage hydroelectric plants performed in support of the U.S. Department of Energy Water Power Program, the characteristics of existing U.S. pumped storage hydroelectric plants (PSHs) are reviewed to define criteria for selecting candidate sites for new pumped storage plants. These characteristics are discussed and are presented in an appendix table. Candidate sites for new PSHs using existing U.S. hydroelectric plants, non-powered dams, greenfield hydroelectric plant sites, and natural waterbodies as base plant locations and natural waterbodies as auxiliary reservoirs are identified using criteria based on PSHs. Characteristics of the candidate sites are discussed and their characteristic features are provided in the appendix tables and spreadsheets.

13 HYDRO ENERGY↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Experimental Analysis of 10Gbps Transfers Over Physical and Emulated Dedicated Connections

Long haul data transfers require the optimization and balancing of performances of host and storage systems as well as network transport. An assessment of such transport methods requires a systematic generation of throughput profiles from measurements collected over different system parameters and connection lengths. We describe host and storage systems to support wide-area I/O transfers at 10 Gbps, and present measurements of memory and disk transfer throughputs over suites of physical and emulated connections of several thousands of miles. The physical connections are limited by the infrastructure and incur significant costs. The emulated connections could be of arbitrary lengths at significantly lower costs but only approximate the physical connections. We present a differential regression method to estimate the differences between the performance profiles of physical and emulated connections, and then to estimate 'physical' profiles from emulated measurements. We present a systematic analysis of wide-area memory and disk transfer throughput measurements, and establish that robust estimates of physical profiles can be generated using much less expensive emulated connections.

99 GENERAL AND MISCELLANEOUS↗

Single cell performance studies on the Fe/Cr Redox Energy Storage System using mixed reactant solutions at elevated temperature

Experimental studies in a 14.5 sq cm single cell system using mixed reactant solutions at 65 C are described. Systems were tested under isothermal conditions i.e., reactants and the cell were at the same temperature. Charging and discharging performance were evaluted by measuring watt-hour and coulombic efficiencies, voltage-current relationships, hydrogen evolution and membrane resistivity. Watt-hour efficiencies ranged from 86% at 43 ma/sq cm to 75% at 129 ma/sq cm with corresponding coulombic efficiencies of 92% and 97%, respectively. Hydrogen evolution was less than 1% of the charge coulombic capacity during charge-discharge cycling. Bismuth and bismuth-lead catalyzed chromium electrodes maintained reversible performance and low hydrogen evolution under normal and adverse cycling conditions. Reblending of the anode and cathode solutions was successfully demonstrated to compensate for osmotic volume changes. Improved performance was obtained with mixed reactant systems in comparison to the unmixed reactant systems.

Gahn, R. F.↗

Single cell performance studies on the FE/CR Redox Energy Storage System using mixed reactant solutions at elevated temperature

Experimental studies in a 14.5 sq cm single cell system using mixed reactant solutions at 65 C are described. Systems were tested under isothermal conditions, i.e., reactants and the cell were at the same temperature. Charging and discharging performance were evaluated by measuring watt-hour and coulombic efficiencies, voltage-current relationships, hydrogen evolution and membrane resistivity. Watt-hour efficiencies ranged from 86 percent at 43 ma/sq cm to 75 percent at 129 ma/sq cm with corresponding coulombic efficiencies of 92 percent and 97 percent, respectively. Hydrogen evolution was less than 1 percent of the charge coulumbic capacity during charge-discharge cycling. Bismuth amd bismuth-lead catalyzed chromium electrodes maintained reversible performance and low hydrogen evolution under normal and adverse cycling conditions. Reblending of the anode and cathode solutions was successfully demonstrated to compensate for osmotic volume changes. Improved performance was obtained with mixed reactant systems in comparison to the unmixed reactant systems. Previously announced in STAR as N83-25042

Gahn, R. F.↗

Evolving Requirements for Magnetic Tape Data Storage Systems

Magnetic tape data storage systems have evolved in an environment where the major applications have been back-up/restore, disaster recovery, and long term archive. Coincident with the rapidly improving price-performance of disk storage systems, the prime requirements for tape storage systems have remained: (1) low cost per MB, (2) a data rate balanced to the remaining system components. Little emphasis was given to configuring the technology components to optimize retrieval of the stored data. Emerging new applications such as network attached high speed memory (HSM), and digital libraries, place additional emphasis and requirements on the retrieval of the stored data. It is therefore desirable to consider the system to be defined both by STorage And Retrieval System (STARS) requirements. It is possible to provide comparative performance analysis of different STARS by incorporating parameters related to (1) device characteristics, and (2) application characteristics in combination with queuing theory analysis. Results of these analyses are presented here in the form of response time as a function of system configuration for two different types of devices and for a variety of applications.

Gniewek, John J.↗

Performance Evaluation of Lower-Energy Energy Storage Alternatives for Full-Hybrid Vehicles; NREL (National Renewable Energy Laboratory)

Automakers have been mass producing hybrid electric vehicles (HEVs) for well over a decade, and the technology has proven to be very effective at reducing per-vehicle fuel use. However, the incremental cost of HEVs such as the Toyota Prius or Ford Fusion Hybrid remains several thousand dollars higher than the cost of comparable conventional vehicles, which has limited HEV market penetration. The b b b b battery energy storage device is typically the component with the greatest contribution toward this cost increment, so significant cost reductions/performance improvements to the energy storage system (ESS) can correspondingly improve the vehicle-level cost/benefit relationship. Such an improvement would in turn lead to larger HEV market penetration and greater aggregate fuel savings. The United States Advanced Battery Consortium (USABC) and the U.S. Department of Energy (DOE) Energy Storage Program managers asked the National Renewable Energy Laboratory (NREL) to collaborate with a USABC Workgroup and analyze the trade-offs between vehicle fuel economy and reducing the decade-old minimum energy requirement for power-assist HEVs. NREL’s analysis showed that significant fuel savings could still be delivered from an ESS with much lower energy storage than the previous targets, which prompted USABC to issue a new set of lower-energy ESS (LEESS) targets that could be satisfied by a variety of technologies. With support from DOE, NREL has developed an HEV test platform for in-vehicle performance and fuel economy validation testing of the hybrid system using such LEESS devices. This presentation describes development of the vehicle test platform, and laboratory as well as in-vehicle evaluation results with alternate energy storage configurations as compared to the production battery system. The alternate energy storage technologies considered include lithium-ion capacitors -- i.e., asymmetric electrochemical energy storage devices possessing one electrode with battery-type characteristics (lithiated graphite) and one with ultracapacitor-type characteristics (carbon) -- and electrochemical double-layer capacitors.

33 ADVANCED PROPULSION SYSTEMS↗

Implementing efficient data compression and encryption in a persistent key-value store for HPC

Recently, persistent data structures, like key-value stores (KVSs), which are stored in a high-performance computing (HPC) system’s nonvolatile memory, provide an attractive solution for a number of emerging challenges like limited I/O performance. Data compression and encryption are two well-known techniques for improving several properties of such data-oriented systems. This article investigates how to efficiently integrate data compression and encryption into persistent KVSs for HPC with the ultimate goal of hiding their costs and complexity in terms of performance and ease of use. Our compression technique exploits deep memory hierarchy in an HPC system to achieve both storage reduction and performance improvement. Our encryption technique provides a practical level of security and enables sharing of sensitive data securely in complex scientific workflows with nearly imperceptible cost. We implement the proposed techniques on top of a distributed embedded KVS to evaluate the benefits and costs of incorporating these capabilities along different points in the dataflow path, illustrating differences in effective bandwidth, latency, and additional computational expense on Swiss National Supercomputing Centre’s Grand Tavé and National Energy Research Scientific Computing Center’s Cori.

97 MATHEMATICS AND COMPUTING↗

Energy Storage Improves Power Plant Flexibility and Economic Performance

Most existing coal-fired power plants were designed for sustained operation at full load to maximize efficiency, reliability, and revenue, as well as to operate air pollution control devices at design conditions. Depending on plant type and design, these plants can adjust output within a fixed range in response to plant operating or market conditions. The need for flexibility driven by increased penetration of variable and non-dispatchable power generation, such as wind and solar, is shifting the traditional mission profile of thermoelectric power plants in three ways: more frequent shutdowns when market or grid conditions warrant, more aggressive load ramp rates (rate of output change), and a lower minimum sustainable load, which provides a wider operating range and helps avoid costly plant shutdowns. Recent studies have shown that the flexibility of a coal-fired power plant can be improved by energy storage. The objective of this work was to analyze a set of energy storage options and determine their impact on the flexibility and economics of a representative coal-fired power plant. The effect of three energy storage systems integrated with a coal power plant on plant flexibility and economics was investigated. The results obtained in this project show that energy storage systems integrated with a thermal power plant improve plant flexibility and participation in the energy and ancillary services markets, which improves plant financial performance.

20 FOSSIL-FUELED POWER PLANTS↗

Re-Designing the CSP Thermal Energy Storage System to Enable Higher-Temperature Performance at Reduced Cost (Final Technical Report)

Current commercial concentrating solar power (CSP) plants distinguish themselves from ordinary photovoltaic (PV) power plants by storing enough collected energy to enable generation for several hours after the sun goes down. CSP plants store this energy in the sensible heat of nitrate salts in large metallic storage tanks. Stainless-steel AISI 347H (SS347H) is needed for the hot tank operating at about 565 degrees C whereas carbon steel is sufficient for the cold-tank materials. Two-tank nitrate-salt thermal energy storage (TES) is presently in use in several trough-based CSP plants in Europe and in the U.S., operating up to about 390 degrees C. Three commercially operating tower-based CSP plants - Gemasolar in Spain, Crescent Dunes in Nevada, and Noor III in Morocco - use the same approach, storing nitrate salts at temperatures up to 580 degrees C. SS347H is many times more expensive than carbon steel and constitutes a significant cost element in today's CSP plants. Hence, CSP developers need to close the cost gap with PV-based solar plants by making cost reductions in every system of the plant. Redesigning the TES tanks is one opportunity for cost reduction.

14 SOLAR ENERGY↗

Structure-dependent performance of TiO 2 /C as anode material for Na-ion batteries

The performance of energy storage materials is highly dependent on their nanostructures. Herein, hierarchical rod-in-tube TiO 2 with a uniform carbon coating is synthesized as the anode material for sodium-ion batteries by a facile solvothermal method. This unique structure consists of a tunable nanorod core, interstitial hollow spaces, and a functional nanotube shell assembled from two-dimensional nanosheets. By adjusting the types of solvents used and reaction time, the morphologies of TiO 2 /C composites can be tuned to nanoparticles, microrods, rod-in-tube structures, or microtubes. Among these materials, rod-in-tube TiO 2 with a uniform carbon coating shows the highest electronic conductivity, specific surface area (336.4 m 2 g -1 ), and porosity, and these factors lead to the best sodium storage capability. Benefiting from the unique structural features and improved electronic/ionic conductivity, the as-obtained rod-in-tube TiO 2 /C in coin cell tests exhibits a high discharge capacity of 277.5 and 153.9 mAh g -1 at 50 and 5000 mA g -1 , respectively, and almost 100% capacity retention over 14,000 cycles at 5000 mA g -1 . In operando high-energy X-ray diffraction further confirms the stable crystal structure of the rod-in-tube TiO 2 /C during Na + insertion/extraction. Finally, this work highlights that nanostructure design is an effective strategy to achieve advanced energy storage materials.

25 ENERGY STORAGE↗