Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fermilab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

The Fermilab Holometer: A program to measure Planck scale indeterminacy

We propose an experiment at Fermilab to study a conjectured effect called "holographic noise" that may arise from new Planck scale physics: the measured positions of bodies may wander randomly from ideal geodesics of classical relativity, in measurement-dependent directions, by about a Planck length per Planck time. The experiment will search for this holographic jitter in the relation of mass-energy and space-time by looking for correlated phase noise between two neighboring 40 meter interferometers. The goal of the experiment is to provide convincing evidence for or against the hypothesis that relative transverse positions of bodies display this particular new kind of quantum noise, whose power spectrum is independent of frequency and has a spectral density determined only by the Planck time. A positive result of the experiment would be a major step forward in understanding the emergence of space time and mass-energy from a unified theory of spacetime and quantum mechanics. A negative result will impact the macroscopic interpretation of unified theories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Emittance Measurements of the Fermilab Linac Beam Using the MTA Beamline

The MTA beam line has been specifically designed to facilitate measurements of the Fermilab Linac beam emittance and properties utilizing a long, 10m, element-free straight. Linac beam is extracted downstream of the 400-MeV electrostatic chopper located in the Booster injection line. This chopper cannot be utilized for MTA beam, and therefore the entire Linac beam pulse is directed into the MTA beamline. Pulse length manipulation is provided by the 750-keV electrostatic chopper at the upstream end of the Linac and, using this device, beam can be delivered from 8 μsec up to the full 50 μsec Linac pulse length. The 10 m emittance measurement straight exploits and begins at the 12' shield wall that separates the MTA Experimental Hall and beamline stub from the Linac enclosure. A quadrupole triplet has been installed upstream of the shield wall in order to focus a large, 1.5-2' (~95% width) beam through the shield wall and onto a profile monitor located at the exit of the shielding. Another profile monitor has been installed upstream of the shield wall, ~5 m upstream of the central, or focal-point monitor. With the triplet, a small, 0.2-0.5' spot size was produced for the initial measurement reported here. As will be shown in this report, a small, approximate beam waist located near a center profile monitor reduces the number of unknown linear optical parameters to two Courant-Snyder parameters, β and ε, since, α, or the rotation of the phase ellipse can be determined by propagating the beam envelope from this waist (using the simple linear transfer matrix that describes a drift).

43 PARTICLE ACCELERATORS↗

Fermilab’s Muon Campus: Status, Experiments, and Future

The Fermilab Muon Campus, repurposed Tevatron-era Antiproton Source facilities, is currently the home to the g-2 and Mu2e muon experiments. Collecting data since 2017, the g-2 experiment is wrapping up a final run before the Muon Campus transitions to Mu2e operation. Currently in the commissioning process, the Mu2e experiment is expected to begin calibration and data collection in fiscal year 2024. A majority of the Muon Campus is shared between the two experiments, however the modes of operation for each are significantly different. An 8 GeV primary proton beam strikes a target to produce a 3.1 GeV/c secondary muon beam for g-2, while the Mu2e experiment uses the Delivery Ring, formerly the Antiproton Accumulator Ring, for a pulsed, resonantly extracted, 8 kW, 8 GeV proton beam incident on a target in the experiment's target hall to produce a muon beam for the experiment. The design and current state of the Muon Campus and the current and future plans of the g-2 and Mu2e experiments, including the transition between operating modes, will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Beam Energy in the Fermilab's Linac taken at the transfer Line

Linac is the first machine in the Accelerator chain at Fermilab where 𝐻− particles are accelerated from 35 keV to 400 MeV and travel to the Booster where they are stripped. of the extra electrons to become protons. The Booster requires stable beam energy at injection. The Linac extraction energy tuning has been performed using two Beam Velocity Monitors (a.k.a Griffin detectors) to maintain stable relative energy between the Booster and the Linac. Our goal is to control the Linac energy parameters using Machine Learning techniques to increase reliability and quality of beam delivered from Linac. The first step is to understand the data from the Linac extraction diagnostics; and develop reliable, accurate methods for energy measurement and control before implementing machine learning. There were two methods of energy measurement implemented, and the results of these are compared. The first method was time of flight measurements using the Phase probes inside B eam Position Monitors (BPM) that provide the beam’s phase of arrival data. The second method used the relation between beam position data from the BPMs and dispersion values from the 400MeV MAD-X model to calculate momentum variation. The results of these two energy measurement methods compare well as the Linac energy is varied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Report from the Fermilab Proton Intensity Upgrade Central Design Group

This document is the primary output of the Proton Intensity Upgrade Central Design Group (PIU CDG) which was convened in the summer of 2022. The Group was asked to study options and provide recommendations for upgrading the Fermilab Accelerator Complex including increased reliability and capability and a focus on increasing the proton intensity to the LBNF beamline. Several approaches and combinations of approaches were examined for capability, cost, schedule, risks, and necessary R&D

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automation and Quality Control for CMS Outer Tracker Module Assembly at Fermilab’s SiDet

Automation and quality control techniques for 2S and PS sensor modules for the CMS Outer Tracker for the HL-LHC era have been developed at the Silicon Detector facility at Fermilab. Examples include a laser scanning procedure to check manufacturing specifications for the 2S sensor modules, and an automated gluing process to accurately assemble PS sensor modules. Processes were verified and documented for the production stage of the Outer Tracker.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryogenic Plant Integration for the Colossus milli-Kelvin Platform at Fermilab

The Colossus platform at Fermilab will be the largest and most powerful 3He/4He dilution-cooled cryogenic system constructed to-date. Perhaps its primary innovation will be in the integration of a liquid helium cryogenics plant to cool the stages typically cooled by mechanical cryocoolers in commercially available cryogen-free dilution refrigerators. This design shift carries with it important implications for the future of cryogenics associated with quantum computing due to the inherently greater efficiencies of helium cryogenic plants when compared to the use of multitude of independent mechanical cryocoolers. Construction of Colossus is expected to begin in 2023 with a target of commencing operations in 2025.

Tatkowski, G.↗

Uniform Beam Simulation Technique for Beam Scans and Machine Learning Studies at Fermilab

Fermilab's neutrino facilities, including NuMI and the upcoming LBNF, use proton beams to produce positively and negatively charged pions and kaons. Detailed simulations are necessary to study particle interactions and beam propagation. To efficiently analyze beam scan effects, we propose a technique to generate multiple simulation samples with high statistics. These samples can be used to develop beamline simulation based machine learning applications. In this technique, we generate a uniformly distributed single simulation data sample. We calculate Gaussian weights for each beam configurations and apply them to post-processing measurements. In this poster, we demonstrate the proposed simulation technique. This technique reduces simulation time and computing resources significantly.

Wickremasinghe, Athula↗

Overview of the Muon 𝑔 − 2 Experiment at Fermilab

Searching for anomalies is one of the most interesting approaches to physics research. Many particle physicists look for discrepancies between experimental measurements and theoretical predictions because we know that identifying and understanding anomalies can be a major component of building a more fundamental description of nature. The Muon g-2 experiment at Fermilab measures the magnetic anomaly of the muon with extremely high precision. In 2021, the Muon g-2 Collaboration reported its first result at a precision of 460 ppb based on the first data-taking run comprising 6% of the total data set to be collected. This result is in good agreement with the previous measurement from Brookhaven National Laboratory, giving greater certainty to the world average of the experimental value. The next even higher precision Muon g-2 result will play an important role given the recent tensions between data-driven dispersive and lattice QCD calculations to predict the hadronic vacuum polarization contribution. I begin this talk with a review of muon g-2 physics and the experimental technique. Then I present a timeline including the past Run 1 result milestone, current status of Runs 2/3 analysis, and projections to finalize work on the final data from Runs 4/5/6. I conclude with a brief discussion of new ideas and future plans for the Muon g-2 experiment after the completion of Run 6.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Matter Search in the Muon g-2 experiment at Fermilab

Dark matter is one of the most interesting research topics in physics. Many particle physicists are trying to identify it because we know that dark matter could be a major component of a complete fundamental description of nature. The Muon g-2 Experiment at Fermilab measures the anomalous precession frequency of the muon. Oscillations of this precession frequency could be produced by dark matter coupling to muons. This talk will describe how we could observe DM signals in the Muon g-2 data. I will explain how we determine the Muon g-2 DM mass range sensitivity, and analysis strategies throughout the mass range. Finally, I will present the expected Muon g-2 experiment discovery/exclusion reach in selected DM model-dependent scenarios.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commissioning of new CVD/ALD Furnace at Fermilab

The new CVD/ALD furnace that we are commissioning at Fermilab will allow us to deposit thin films of superconducting materials on RF cavities on different shapes, 1 cell and 9 cells 1.3GHz and 1 cell and 5 cells 650MHz. This furnace is capable to perform two different types of deposition: chemical vapor deposition and atomic layer deposition. Different materials are under investigation to push accelerating superconducting RF cavities to support higher accelerating fields and to operate with lower power loss. The first tests are focusing on the alternative A15 superconductors as: Nb3Ge, Nd3Ga, Nb3Sn, V3Si. The furnace has two different sources of precursors: 1) chlorine furnace, where we can produce the precursors in-situ, so we can build our own precursors and test how the deposited material is affecting the cavity performance, 2) 6 different bubblers, 3 low temperature bubblers and 3 high temperature bubblers. The deposition chamber is a versatile chamber with two independ ent vacuum volumes, to ensure a higher cleanliness of the deposited material. The furnace is designed to have two different configurations: High temperature, up to 1400 C, and low temperature, up to 400 C.

Grassellino, Laura↗

The Mu2e Experiment at Fermilab

The Muon-to-Electron-Conversion (Mu2e) Experiment is a high-precision, intensity-frontier experiment being developed at Fermilab that will search for coherent, neutrino-less muon to electron conversion in the presence of an atomic nucleus. Such a process would exhibit charged lepton flavor violation (CLFV), which has not yet been observed. Continuing the search for CLFV, Mu2e will improve the sensitivity by four orders of magnitude over the present limits. In the search for beyond the standard model (BSM) physics, Mu2e is uniquely sensitive to a wide range of models by indirectly probing mass scales up to the energy scale of 10^4 TeV. While muon-to-electron-conversion is permissible in an extension of the standard model through neutrino oscillations, the rate is extremely low at about one event in 10^52. By design, the background for the experiment will be well-understood and kept at a sub-event level, which will mean the observation of muon-to-electron conversion is a dire ct confirmation of BSM physics. The physics motivation, the design, and the current status of the experiment will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the Top Plate and Anticryostat for High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory (FNAL) and Lawrence Berkeley National Laboratory (LBNL) are building a new High Field Vertical Magnet Test Facility (HFVMTF) for testing superconducting cables in high magnetic field. This facility will be located at Fermilab and will have a capability similar to EDIPO at PSI and FRESCA2 at CERN. The background magnetic field of 15T in HFVMTF will be produced by a magnet pro-vided by LBNL. The HFVMTF is jointly funded by the US DOE Offices of Science, High Energy Physics, and Fusion Energy Sciences. As a primary use it will be superconducting cable test facility, in high magnetic fields and wide range of temperatures. Complementary, this facility will be used to test high-field super-conducting magnet models and demonstrators, including hybrid magnets, produced by the US Magnet Development Program (MDP). The paper describes the status of Top Plates Assembly and Sample Insert Anticryostat, which will be a main interface component between cable test mode and magnet test mode at this facility.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fermilab Upgrades and a Future Muon Program

We provide a path for a future muon-based CLFV program could be performed at Fermilab and discuss synergies with Muon Collider efforts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HTS Magnet Activity at Fermilab

This presentation reports the progress of High Temperature Superconducting magnet development activities at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fermilab Main Injector and Recycler Operations in the Megawatt Era

Significant upgrades to Fermilab’s accelerator complex have accompanied the development of LBNF (the Long Baseline Neutrino Facility) and DUNE (Deep Underground Neutrino Experiment). These improvements will facilitate 1-MW operation of the NuMI (Neutrinos at the Main Injector) beam for the first time this year through changes to the Recycler slip-stacking procedure and shortening of the Main Injector ramp time. The modifications to the Recycler slip-stacking and efforts to reduce the duration of the Main Injector ramp will be discussed. Additionally, details regarding further shortening of the ramp time and the subsequent impacts on future accelerator operations are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗