Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Topography restoration in white-light interferometry using an instrument transfer function evaluated with binary pseudo-random arrays

Accurate knowledge of the instrument transfer function (ITF) is vital for topography measurements using white-light interferometry (WLI). To this end, we derive a complete set of analytical expressions for the power spectral density (PSD) of a discretely sampled binary pseudo-random array (BPRA) as a theoretical benchmark. We then determine the ITF by comparing this theoretical PSD with the measured PSD of the BPRA. For the Zygo ZeGage Pro HR with a objective, the determined ITF closely matches the nominal modulation transfer function (MTF). Accordingly, we integrate the nominal MTF into Fourier-domain restoration filters and apply them to practical WLI topography data, yielding restored topographies that show improved agreement with atomic force microscopy measurements. Overall, our integrated BPRA-based ITF measurement and filtering methodology offers a robust yet practical means of characterizing WLI performance and enhancing the accuracy of surface measurements.

Hirose, Shigenobu [Japan Agency for Marine Earth S↗

PW2 Pumping: March 18 thru March 22, 2020

Processed Coherence-length-gated Microwave Photonics Interferometry (CMPI) distributed vertical strain on March 18 through March 22, 2020 at the hydromechanical test facility located at the Clemson University Simpson Station research facility in Central, South Carolina, USA. This includes ambient data in addition to a pumping test performed between 14:31-20:31 EST on 3/22/2020 from Pumping Well 2 (PW2). These data are from a strain ribbon that was deployed in the vadose zone at approximately 34.670130°N, -82.729524°E from the ground surface to a depth of 8m in saprolite containing weak reflectors pairs were placed every 0.85 m along the fiber. Each weak reflector pair forms a 15 cm cavity strain meter. Strain unit: meters/meter (strain). Sampling rate 0.1 Hz. Each column corresponds to the strain data taken at a depth d from the ground surface. c1: d = 1.00m c2: d = 1.85m c3: d = 2.70m c4: d = 3.55m (large demodulation error) c5: d = 4.40m c6: d = 5.25m c7: d = 6.10m (large demodulation error) c8: d = 6.95m

Distributed Strain Sensing↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Experimental upper limit on the estimated thermal noise at low frequencies in a gravitational wave detector

The mirror relative motion of a suspended Fabry-Perot cavity is studied in the frequency range 3-100 Hz. The experimental measurements presented in this paper have been performed at the Low Frequency Facility, a high finesse optical cavity 1 cm long suspended to a mechanical seismic isolation system like the one of the VIRGO gravitational wave antenna. Because of the radiation pressure between the two mirrors of the cavity, the dynamic behavior of the system is characterized by the optical spring stiffness. In the frequency region above 3 Hz, where seismic noise contamination is negligible, the mirror displacement noise is stationary and its statistical distribution is Gaussian. Using a simplified mechanical model of the suspended system and applying the fluctuation dissipation theorem, we show that the measured power spectrum is reproduced in the frequency region 3-90 Hz. Since the contribution coming from different sources of the system to the total noise budget turns out to be negligible, we conclude that the relative displacement power spectrum of this opto-mechanical system is compatible with a system at thermal equilibrium within its environment. In the region 3-10 Hz this measurement gives so far the best upper limit for the thermal noise of the suspension for a gravitational wave interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental study of high-energy single-pulse nanosecond discharges in pin-to-pin configuration

Single-pulse pin-to-pin nanosecond pulsed discharges in ambient air (gap distances of 3–7 mm) were investigated at high pulse energies (∼20–30 mJ deposited energy per 11 ns full width at half maximum pulse). A Michelson interferometry setup (532 nm continuous-wave laser) was employed to record time-resolved interferograms of the discharge, enabling spatially resolved calculation of the electron number density. An intensified charge-coupled device camera was used to capture the spatiotemporal evolution of the discharge (streamer formation and spark channel development), and Coherent Anti-Stokes Raman Spectroscopy (CARS) was used to measure post-discharge N 2 vibrational temperatures. Discharge current and voltage were monitored with a back-current shunt. The discharge was initiated with simultaneous cathode-directed and anode-directed streamers that bridge the gap within ∼1 ns and form a luminous, filamentary plasma channel immediately after breakdown. Laser interferometry measurements showed peak electron number densities of the order of 10 1 7–10 18 cm −3 , occurring about 15–20 ns after pulse arrival at the discharge gap. Shorter gap discharges yielded higher peak electron densities, consistent with the higher energy density in the smaller gaps. Spatially, the electron density was highest near the electrodes and decreased toward the midgap region, with 5 and 7 mm gaps exhibiting a pronounced drop in the central channel. CARS indicated initial vibrational temperatures of approximately 4000–6000 K in the spark core of ∼50 ns after the discharge onset, decaying on a ∼500 ns timescale as the plasma cooled and recombined.

Coherent anti-Stokes Raman spectroscopy↗

DENSITY OF WARM IONIZED GAS NEAR THE GALACTIC CENTER: LOW RADIO FREQUENCY OBSERVATIONS

We have observed the Galactic center (GC) region at 0.154 and 0.255 GHz with the Giant Metrewave Radio Telescope. A total of 62 compact likely extragalactic (EG) sources are detected. Their scattering sizes decrease linearly with increasing angular distance from the GC up to about 1 Degree-Sign . The apparent scattering sizes of the sources are more than an order of magnitude less than predicted earlier by the NE2001 model of Galactic electron distribution within 359. Degree-Sign 5 < l < 0. Degree-Sign 5 and -0. Degree-Sign 5 < b < 0. Degree-Sign 5 (Hyperstrong Scattering Region) of the Galaxy. High free-free optical depths ({tau}) are observed toward most of the extended non-thermal sources within 0. Degree-Sign 6 from the GC. Significant variation of {tau} indicates that the absorbing medium is patchy at an angular scale of {approx}10' and n{sub e} is {approx}10 cm{sup -3}, which matches the NE2001 model. This model predicts the EG sources to be resolved out from 1.4 GHz interferometric surveys. However, out of 10 EG sources expected in the region, 8 likely EG are present in the 1.4 GHz catalog. Ionized interfaces of dense molecular clouds to the ambient medium are most likely responsible for strong scattering and low radio frequency absorption. However, dense GC clouds traced by CS J = 1-0 emission are found to have a narrow distribution of {approx}0. Degree-Sign 2 across the Galactic plane. Angular distribution of most EG sources seen through the so-called Hyperstrong Scattering Region are random in b, and typically {approx}7 out of 10 sources will not be seen through the dense molecular clouds, which explains why most of them are not scatter broadened at 1.4 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Cross-polarized common-path temporal interferometry for high-sensitivity strong-field ionization measurements

Absolute density measurements of low-ionization-degree or low-density plasmas ionized by lasers are very important for understanding strong-field physics, atmospheric propagation of intense laser pulses, Lidar etc. A cross-polarized common-path temporal interferometer using balanced detection was developed for measuring plasma density with a sensitivity of ∼0.6 mrad, equivalent to a plasma density-length product of ∼2.6 × 10 13 cm −2 if using an 800 nm probe laser. By using this interferometer, we have investigated strong-field ionization yield versus intensity for various noble gases (Ar, Kr, and Xe) using 800 nm, 55 fs laser pulses with both linear (LP) and circular (CP) polarization. The experimental results were compared to the theoretical models of Ammosov-Delone-Krainov (ADK) and Perelomov-Popov-Terent’ev (PPT). We find that the measured phase change induced by plasma formation can be explained by the ADK theory in the adiabatic tunneling ionization regime, while PPT model can be applied to all different regimes. We have also measured the photoionization and fractional photodissociation of molecular (MO) hydrogen. By comparing our experimental results with PPT and MO-PPT models, we have determined the likely ionization pathways when using three different pump laser wavelengths of 800 nm, 400 nm, and 267 nm.

47 OTHER INSTRUMENTATION↗

Shock initiation of low density polymer bonded explosive LX-14: A study of two morphologies

A series of six shock initiation experiments have been carried out on low density LX-14 powder in order to simulate a shock insult on the heavily damage polymer bonded explosive, LX-14. Two distinct morphologies were studied (tap density molding powder and machined swarf), both at the same density of 0.942 g/cm 3 , or 50.1% theoretical maximum density. The purpose of these experiments was to provide data to help make an assessment of the effects that damage has on the material sensitivity to a planar shock. This was achieved primarily by providing shock sensitivity data in the form of a Pop plot, and also reactants equation of state data, which aids in the determination of input conditions for both the experiments performed in this work and also future experiments of this material type. The experiments were of a cut-back format, consisting of four sample heights on each shot and diagnosed with optical velocimetry. The experiments were carried out at the Technical Area 40 Chamber 9 gas gun facility at the Los Alamos National Laboratory, where the LX-14 targets were subjected to Al 6061 and Oxygen Free High Conductivity copper impactors launched to velocities up to 2.14 km/s. Time corrected reactive growth wave profiles are presented in this paper along with the derivation of the following Hugoniot parameters for this explosive, where the molding powder and machine swarf are represented by the following linear equations, respectively, U s = 1.64 (±0.64)u p + 2.25 (±0.49) and U s = 0.87 (±.0.60)u p + 4.08 (±0.49). The results show that the steady increase in shock sensitivity with increasing void fraction reaches an inflection point beyond which the shock sensitivity begins to decease. This inflection point lies between 65% and 50% of the theoretical maximum density of the LX-14. In both cases, the damaged LX-14 was not as sensitive as expected, with a relative shock sensitivity of the molding powder being less than the pressed LX-14, and the machined swarf having a shock sensitivity that is comparable to pressed LX-14.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase Doppler Interferometry for Efficient Cloud Drop Size Distribution, Number Density, and LWC Measurements

Threats to aviation safety as a result of super-cooled large drops (SLD) has been addressed by the FAA rules change (14 CFR Part 25) with the additional icing certification requirement. SLD clouds often consist of bi-modal drop size spectra leading to significant problems in simulating and characterizing these conditions in situ and in icing wind tunnels. Legacy instrumentation for measuring drop size distributions and liquid water content are challenged under these conditions. The large size range measurement problem is addressed with the development of the Phase Doppler Interferometer, Flight Probe Dual-Range (PDI FPDR). The method is described in this report along with the measurement capabilities including the dynamic measurement range and overall working size range. The PDI instrument bases drop size measurements on the light wavelength as the measurement length scale. The light wavelength is a much more robust scale, especially as compared to the light scattering intensity. Additionally, methods for accurately characterizing the sample volume in situ based on measured drop velocity and transit time are reviewed, given the importance of this parameter for merging results and measuring LWC. Droplet coincidence in the sample volume can be problematic so this condition is treated with an innovative signal parsing approach. Measurement examples acquired in the NASA IRT are provided. Measurements of LWC showed good agreement with the Artium Particle Imaging (PI) instrument but diverged from the tunnel calibration results for larger MVD values.

42 ENGINEERING↗

Insect Wing Displacement Measurement Using Digital Holography

Insects in flight have been studied with optical non destructive techniques with the purpose of using meaningful results in aerodynamics. With the availability of high resolution and large dynamic range CCD sensors the so called interferometric digital holographic technique was used to measure the surface displacement of in flight insect wings, such as butterflies. The wings were illuminated with a continuous wave Verdi laser at 532 nm, and observed with a CCD Pixelfly camera that acquire images at a rate of 11.5 frames per second at a resolution of 1392x1024 pixels and 12 Bit dynamic range. At this frame rate digital holograms of the wings were captured and processed in the usual manner, namely, each individual hologram is Fourier processed in order to find the amplitude and phase corresponding to the digital hologram. The wings displacement is obtained when subtraction between two digital holograms is performed for two different wings position, a feature applied to all consecutive frames recorded. The result of subtracting is seen as a wrapped phase fringe pattern directly related to the wing displacement. The experimental data for different butterfly flying conditions and exposure times are shown as wire mesh plots in a movie of the wings displacement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Second Harmonic Generation Electric Field Triplet Interferometry for Absolute Phasing

We report second harmonic generation (SHG) electric field triplet interferometry performed using three mutually coherent ultrafast pulses in a common path with controllable relative phases, namely, the light fields of a sample signal (SI), a reference oscillator (RO), and a local oscillator (LO). The ROLO phase determined from the interference of the light fields produced by two quartz wafers is subtracted from the phase determined from the SIROLO interferogram to yield the signal phase, ϕ SI . The new method also calibrates the measured SHG intensity from a given sample internally by sending the fundamental light field reflected from the sample into one of the quartz wafers in the ROLO element. The approach avoids having to exchange the sample against a reference material with a known χ(2) value or known phase and accounts on-the-fly for situations where the reflected fundamental light field intensity changes with experimental conditions. The new method is successfully benchmarked against z-cut α-quartz, fused silica held at its point of zero charge, and hematite nanolayers in air, across three different interferometers. Furthermore, the approach should be applicable for other second-order nonlinear spectroscopies, such as vibrational or electronic sum-frequency generation.

Interfaces↗

IONIZATION SOURCE OF A MINOR-AXIS CLOUD IN THE OUTER HALO OF M82

The M82 ''cap'' is a gas cloud at a projected radius of 11.6 kpc along the minor axis of this well-known superwind source. The cap has been detected in optical line emission and X-ray emission and therefore provides an important probe of the wind energetics. In order to investigate the ionization source of the cap, we observed it with the Kyoto3DII Fabry-Perot instrument mounted on the Subaru Telescope. Deep continuum, H{alpha}, [N II]{lambda}6583/H{alpha}, and [S II]{lambda}{lambda}6716,6731/H{alpha} maps were obtained with subarcsecond resolution. The superior spatial resolution compared to earlier studies reveals a number of bright H{alpha} emitting clouds within the cap. The emission line widths ({approx}< 100 km s{sup -1} FWHM) and line ratios in the newly identified knots are most reasonably explained by slow to moderate shocks velocities (v{sub shock} 40-80 km s{sup -1}) driven by a fast wind into dense clouds. The momentum input from the M82 nuclear starburst region is enough to produce the observed shock. Consequently, earlier claims of photoionization by the central starburst are ruled out because they cannot explain the observed fluxes of the densest knots unless the UV escape fraction is very high (f{sub esc} > 60%), i.e., an order of magnitude higher than observed in dwarf galaxies to date. Using these results, we discuss the evolutionary history of the M82 superwind. Future UV/X-ray surveys are expected to confirm that the temperature of the gas is consistent with our moderate shock model.

79 ASTRONOMY AND ASTROPHYSICS↗

INTERFEROMETRIC OBSERVATIONS OF NITROGEN-BEARING MOLECULAR SPECIES IN THE STAR-FORMING CORE AHEAD OF HH 80N

We present Very Large Array NH{sub 3} and Plateau de Bure Interferometer NH{sub 2}D and HN{sup 13}C observations of the star-forming core ahead of HH 80N, the optically obscured northern counterpart of the Herbig-Haro objects HH 80/81. The main goal is to determine the kinematical information of the high density regions of the core (n ∼> 10{sup 5} cm{sup –3}) missed in previous works due to the depletion of the species observed (e.g., CS). The obtained maps show different kinematical signatures between the eastern and western parts of the core, suggesting a possible dynamical interaction of the core with the HH 80/81/80N outflow. The analysis of the position-velocity (P-V) plots of these species rules out a previous interpretation of having a molecular ring-like structure with a radius of 6 × 10{sup 4} AU traced by CS infalling onto a central protostar found in the core (IRS1). A high degree of NH{sub 3} deuteration, with respect to the central part of the core harboring IRS1, is derived in the eastern part, where a dust condensation (SE) is located. This deuteration trend of NH{sub 3} suggests that SE is in a pre-stellar evolutionary stage, earlier than that of IRS1. Since SE is the closest condensation to the HH 80N/81/80N outflow, in a case of outflow-core dynamical interaction, it should be perturbed first and be the most evolved condensation in the core. Therefore, the derived evolutionary sequence for SE and IRS1 makes outflow triggered star formation on IRS1 unlikely.

79 ASTRONOMY AND ASTROPHYSICS↗

Shock state distributions in porous tantalum and characterization with multipoint velocimetry

Heterogenous materials under shock compression can be expected to reach different shock states throughout the material according to local differences in microstructure and the history of wave propagation. Here, in this work, a compact, multiple-beam focusing optic assembly is used with high-speed velocimetry to interrogate the shock response of porous tantalum films prepared through thermal-spray deposition. The distribution of particle velocities across a shocked interface is compared to results obtained using a set of defocused interferometric beams that sampled the shock response over larger areas. The two methods produced velocity distributions along the shock plateau with the same mean, while a larger variance was measured with narrower beams. The finding was replicated using three-dimensional, mesoscopically resolved hydrodynamics simulations of solid tantalum with a pore structure mimicking statistical attributes of the material and accounting for radial divergence of the beams, with agreement across several impact velocities. Accounting for pore morphology in the simulations was found to be necessary for replicating the rise time of the shock plateau. The validated simulations were then used to show that while the average velocity along the shock plateau could be determined accurately with only a few interferometric beams, accurately determining the width of the velocity distribution, which here was approximately Gaussian, required a beam dimension much smaller than the spatial correlation lengthscale of the velocity field, here by a factor of ∼30×, with implications for the study of other porous materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Lapping Technique for Metallic, Alpha-Phase, Plutonium: Achieving and Measuring Nano-Meter Roughness and Sub-Micron Flatness

There are various processes and techniques by which one can achieve well polished (highly reflective) and smooth, flat (low roughness) surfaces on a wide variety of materials. Historically, precision lapping processes were first applied to optical materials for the production of lenses for telescopes and microscopes. These processes have been developed by a multitude of technicians over the centuries and reported in countless publications. These same grinding, lapping and polishing processes have been of great importance in the fabrication and structural characterization of countless optical materials and engineering structures, e.g. optics, Si wafers, precision machined surfaces, engineered devices, low-friction surfaces, mechanical systems, metallographic examination of microstructures, to name but a few. The development of lapping and polishing processes and techniques as applied to extremely hazardous and highly (chemically) reactive materials, such as metallic plutonium (Pu), has been limited. This is due in part due to the sensitive nature of the work as applied to nuclear applications, and limited access and need to work with these materials. For the limited information regarding polishing and lapping of Pu materials that has been documented, there has been virtually no quantitative assessment of qualities such as surface roughness and flatness on the nanometer scale. In this report we use the word “lapping” to refer to the traversing of a specimen surface across an abrasive surface in a controlled manner in order to achieve smooth/flat surfaces. We differentiate lapping from polishing, in that we define polishing as traversing of a sample surface across a non-abrasive surface that contains loose abrasive particles, e.g. diamond paste on nylon nap, in order to achieve a highly reflective surface. In this report, we will detail a simple and repeatable lapping process as applied to alpha-phase metallic Pu. We will provide quantitative measurements of the surface roughness and flatness. We will demonstrate the ability to achieve sub-10 nm surface roughness and to lap millimeter-size areas to a flatness of approximately 1.0 µm. Additionally, we will assess the current limitations and discuss any artifacts that arise as a result of our polishing processes applied to metallic Pu materials.

36 MATERIALS SCIENCE↗

Rippled shock propagation in a laser-driven target at multimegabar pressures

The evolution of non-uniform shocks produced by modulated laser irradiation or surface perturbations is relevant to studies of inertial confinement fusion and material properties at high-energy-density conditions. We present results from an experiment conducted at the OMEGA EP laser facility, where a 300 GPa shock was driven into a fused silica sample with pre-fabricated single-mode surface modulations. Using time-resolved optical velocimetry, we captured the continuous evolution of rippled shock motion, enabling a comprehensive mapping of the spatial amplitude history from formation to phase reversal in a single experiment. Initially, the ablation-driven shock inherits a fraction of the surface modulation amplitude from the sample, which subsequently grows before decaying, ultimately leading to the flattening of the rippled shock and a phase reversal. We find that two-dimensional inviscid hydrodynamic simulation of the experiment is able to qualitatively capture many aspects of the rippled shock evolution but over-predicts the initial amplitude growth. This experimental platform, capable of accommodating varying ripple wavelengths, lays the groundwork for a potential viscometry method at extreme pressures, where viscous effects manifest as differences in shock flattening times between rippled shocks of two distinct wavelengths propagating through the sample.

36 MATERIALS SCIENCE↗

A CATALOG OF NEAR-IR SOURCES FOUND TO BE UNRESOLVED WITH MILLIARCSECOND RESOLUTION

Calibration is one of the long-standing problems in optical interferometric measurements, particularly with long baselines which demand stars with angular sizes on the milliarcsecond scale and no detectable companions. While systems of calibrators have been generally established for the near-infrared in the bright source regime (K {approx}< 3 mag), modern large interferometers are sensitive to significantly fainter magnitudes. We aim to provide a list of sources found to be unresolved from direct observations with high angular resolution and dynamic range, which can be used to choose interferometric calibrators. To this purpose, we have used a large number of lunar occultations recorded with the ISAAC instrument at the Very Large Telescope to select sources found to be unresolved and without close companions. An algorithm has been used to determine the limiting angular resolution achieved for each source, taking into account a noise model built from occulted and unocculted portions of the light curves. We have obtained upper limits on the angular sizes of 556 sources, with magnitudes ranging from K{sub s} Almost-Equal-To 4 to 10, with a median of 7.2 mag. The upper limits on possible undetected companions (within Almost-Equal-To 0.''5) range from K{sub s} Almost-Equal-To 8 to 13, with a median of 11.5 mag. One-third of the sources have angular sizes {<=}1 mas, and two-thirds have sizes {<=}2 mas. This list of unresolved sources matches well the capabilities of current large interferometric facilities. We also provide available cross-identifications, magnitudes, spectral types, and other auxiliary information. A fraction of the sources are found to be potentially variable. The list covers parts of the Galactic Bulge and in particular the vicinity of the Galactic Center, where extinction is very significant and traditional lists of calibrators are often insufficient.

79 ASTRONOMY AND ASTROPHYSICS↗

GOODS-HERSCHEL: GAS-TO-DUST MASS RATIOS AND CO-TO-H{sub 2} CONVERSION FACTORS IN NORMAL AND STARBURSTING GALAXIES AT HIGH-z

We explore the gas-to-dust mass ratio (M{sub gas}/M{sub d}) and the CO luminosity-to-M{sub gas} conversion factor ({alpha}{sub CO}) of two well-studied galaxies in the Great Observatories Origins Deep Survey North field that are expected to have different star-forming modes, the starburst GN20 at z = 4.05 and the normal star-forming galaxy BzK-21000 at z = 1.52. Detailed sampling is available for their Rayleigh-Jeans emission via ground-based millimeter (mm) interferometry (1.1-6.6 mm) along with Herschel PACS and SPIRE data that probe the peak of their infrared emission. Using the physically motivated Draine and Li models, as well as a modified blackbody function, we measure the dust mass (M{sub dust}) of the sources and find (2.0{sup +0.7} {sub -0.6} x 10{sup 9}) M{sub sun} for GN20 and (8.6{sup +0.6} {sub -0.9} x 10{sup 8}) M{sub sun} for BzK-21000. The addition of mm data reduces the uncertainties of the derived M{sub dust} by a factor of {approx}2, allowing the use of the local M{sub gas}/M{sub d} versus metallicity relation to place constraints on the {alpha}{sub CO} values of the two sources. For GN20 we derive a conversion factor of {alpha}{sub CO} < 1.0 M{sub sun} pc{sup -2} (K km s{sup -1}){sup -1}, consistent with that of local ultra-luminous infrared galaxies, while for BzK-21000 we find a considerably higher value, {alpha}{sub CO} {approx}4.0 M{sub sun} pc{sup -2} (K km s{sup -1}){sup -1}, in agreement with an independent kinematic derivation reported previously. The implied star formation efficiency is {approx}25 L{sub sun}/M{sub sun} for BzK-21000, a factor of {approx}5-10 lower than that of GN20. The findings for these two sources support the existence of different disk-like and starburst star formation modes in distant galaxies, although a larger sample is required to draw statistically robust results.

79 ASTRONOMY AND ASTROPHYSICS↗