Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

SU-C-207-01: Four-Dimensional Inverse Geometry Computed Tomography: Concept and Its Validation

Purpose: In past few years, the inverse geometry computed tomography (IGCT) system has been developed to overcome shortcomings of a conventional computed tomography (CT) system such as scatter problem induced from large detector size and cone-beam artifact. In this study, we intend to present a concept of a four-dimensional (4D) IGCT system that has positive aspects above all with temporal resolution for dynamic studies and reduction of motion artifact. Methods: Contrary to conventional CT system, projection data at a certain angle in IGCT was a group of fractionated narrow cone-beam projection data, projection group (PG), acquired from multi-source array which have extremely short time gap of sequential operation between each of sources. At this, for 4D IGCT imaging, time-related data acquisition parameters were determined by combining multi-source scanning time for collecting one PG with conventional 4D CBCT data acquisition sequence. Over a gantry rotation, acquired PGs from multi-source array were tagged time and angle for 4D image reconstruction. Acquired PGs were sorted into 10 phase and image reconstructions were independently performed at each phase. Image reconstruction algorithm based upon filtered-backprojection was used in this study. Results: The 4D IGCT had uniform image without cone-beam artifact on the contrary to 4D CBCT image. In addition, the 4D IGCT images of each phase had no significant artifact induced from motion compared with 3D CT. Conclusion: The 4D IGCT image seems to give relatively accurate dynamic information of patient anatomy based on the results were more endurable than 3D CT about motion artifact. From this, it will be useful for dynamic study and respiratory-correlated radiation therapy. This work was supported by the Industrial R&D program of MOTIE/KEIT [10048997, Development of the core technology for integrated therapy devices based on real-time MRI guided tumor tracking] and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

Design and implementation of wearable devices in machine tools monitoring system - 279

The world's fourth industrial revolution has finally opened after the term Industry 4.0 was proposed by Germany at the Hannover Industrial Fair in 2011, which combined industrial production with an unmanned plant to perform automated production. With the rise of Internet of Things (IoT), cloud computing, and wearing computerized devices has brought more convenience to mankind with the immediate accessibility of the Internet and technology. For example, the development of mobile devices and network technology has inspired the rapid development of wearable devices on mobile devices. Thus, to enhance the current prospects of Taiwan's unmanned machinery factory's monitoring and maintenance capabilities, this paper studies the use of Google glass Machine Tools Monitoring system, GMTM system, to be implemented in Taiwan's machinery factories. GMTM system, via the Internet, monitors sensor tools to collect tool work data to be transferred to cloud computing for analysis, processing and show the actual working conditions of each machine tool. Furthermore, the proposed system uses the monitoring data in the database to inform the factory supervisors the working status of each machine to determine whether there is a need for machine tool maintenance. This system combines real-time monitoring of material with the presentation of Google Glass wearable devices and iBeacon interior space positioning technology. GMTM system can improve the quality of machine tool production and productivity as well as enhance Taiwan's industrial competitiveness. (authors)

47 OTHER INSTRUMENTATION↗

Commissioning a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of the quadrupoles. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing such a system. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). A previous study investigated the error associated with each step by using a permanent quadrupole magnet on an optical mover system. The study reported an error of 11{micro}m for step 1 and a repeatability of 4{micro}m for step 2. However, the set up used a FARO arm to measure tooling balls and didn't allow to accurately check step 2 for errors; an uncertainty of 100{micro}m was reported. Therefore, even though the repeatability was good, there was no way to check that the error in step 2 was small. Following the recommendations of that study, we used a CMM (Coordinate Measuring Machine) instead of the FARO arm for measuring the tooling balls. In addition, a roller cam positioner system replaced the optical movers for moving the quadrupole. With the exception of the quadrupole itself, the system was identical to what will be used in fiducializing the undulator quadrupoles. In this study, we investigate the new vibrating wire set up, including the error associated with each step of fiducialization. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note is a continuation of previous work to study the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Stochastic formulation of patient positioning using linac-mounted cone beam imaging with prior knowledge

Purpose: In this work, a novel stochastic framework for patient positioning based on linac-mounted CB projections is introduced. Based on this formulation, the most probable shifts and rotations of the patient are estimated, incorporating interfractional deformations of patient anatomy and other uncertainties associated with patient setup. Methods: The target position is assumed to be defined by and is stochastically determined from positions of various features such as anatomical landmarks or markers in CB projections, i.e., radiographs acquired with a CB-CT system. The patient positioning problem of finding the target location from CB projections is posed as an inverse problem with prior knowledge and is solved using a Bayesian maximum a posteriori (MAP) approach. The prior knowledge is three-fold and includes the accuracy of an initial patient setup (such as in-room laser and skin marks), the plasticity of the body (relative shifts between target and features), and the feature detection error in CB projections (which may vary depending on specific detection algorithm and feature type). For this purpose, MAP estimators are derived and a procedure of using them in clinical practice is outlined. Furthermore, a rule of thumb is theoretically derived, relating basic parameters of the prior knowledge (initial setup accuracy, plasticity of the body, and number of features) and the parameters of CB data acquisition (number of projections and accuracy of feature detection) to the expected estimation accuracy. Results: MAP estimation can be applied to arbitrary features and detection algorithms. However, to experimentally demonstrate its applicability and to perform the validation of the algorithm, a water-equivalent, deformable phantom with features represented by six 1 mm chrome balls were utilized. These features were detected in the cone beam projections (XVI, Elekta Synergy) by a local threshold method for demonstration purposes only. The accuracy of estimation (strongly varying for different plasticity parameters of the body) agreed with the rule of thumb formula. Moreover, based on this rule of thumb formula, about 20 projections for 6 detectable features seem to be sufficient for a target estimation accuracy of 0.2 cm, even for relatively large feature detection errors with standard deviation of 0.5 cm and spatial displacements of the features with standard deviation of 0.5 cm. Conclusions: The authors have introduced a general MAP-based patient setup algorithm accounting for different sources of uncertainties, which are utilized as the prior knowledge in a transparent way. This new framework can be further utilized for different clinical sites, as well as theoretical developments in the field of patient positioning for radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The pursuit of net-positive sustainability for industrial decarbonization with hybrid energy systems

We report signatories of the Paris Agreement are set to miss their climate targets. The net-zero pledges announced to date across many countries and private industries are insufficient to achieve carbon neutrality, which requires implementation of far-reaching and significantly scaled-up climate-positive actions. All technology options that pertain to deep decarbonization and carbon removal must be part of the mitigation portfolio. Transformative action plans must be established in which every individual/organization around the globe is an actor of changes in relation to net-zero goals. Such plans must involve governmental policy support but also encourage voluntary efforts to boost innovations, investments, initiatives, and behavioral changes. Recognition of these efforts is made quantifiable with the concepts of carbon handprint and net positivity. This paper presents a carbon handprint perspective on characterizing the environmental benefits of hybrid energy systems (HESs)—a widely applicable solution to cleaner production leveraging the capabilities of a portfolio of low-carbon energy sources—that provide heat and electricity to industrial processes. First, the carbon handprint and net positivity concepts and their calculation approach are introduced. The state of the art of HES-enabled industrial cogeneration is then surveyed, and the greenhouse gas emission intensities of different energy sources that power HESs are compared. Next, drawing on a case study about a US chemical facility's voluntary initiative to explore replacing its fossil fuel–based cogeneration infrastructure with a clean energy–generated HES, several technically viable scenarios are evaluated—especially those with small modular nuclear reactors—to illustrate how the positive-thinking handprint approach helps encourage and inform the search for widespread influence pathways in pursuit of net-positive sustainability. Finally, current knowledge gaps in the case study are identified, and opportunities to scale up the proposed handprint-based analysis are outlined with consideration of an expanded role of HESs in fulfilling climate objectives.It is envisioned that like-minded decision makers in the industry sector and beyond will adopt this perspective and act synergistically to enhance their environmental stewardship through voluntary actions and make greater contributions to the planet's climate future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Position Papers for Inverse Methods for Complex Systems under Uncertainty Workshop

The ability to solve inverse problems – inferring unknown parameters, structures, or states of a system from observed data – is essential for advancing scientific discovery and innovation capabilities for the DOE mission. Basic research needs and challenges are particularly acute in emerging areas such as the interactive, data-driven, modeling and simulation of digital twins; decision support for experiments at DOE scientific user facilities; and for other complex systems and workflows. Inverse problems are at the heart of understanding and controlling complex systems due to factors such as observational data with varying modalities and fidelities, inherent uncertainties in physical measurements and numerical models, and the computational demands of rapid and high-fidelity simulations. The convergence of recent scientific computing trends – scientific machine learning, artificial intelligence, and computing advances such as exascale computing – is creating unprecedented opportunities. These advancements offer the potential to revolutionize how we approach inverse problems to extract actionable insights with the required level of accuracy and computational efficiency. This workshop and the Call for Position Papers are vital steps in bringing together experts to collectively explore and identify the new computational and mathematical directions needed in inverse methods for complex systems under uncertainty.

97 MATHEMATICS AND COMPUTING↗

Intraoperative Localization of Tantalum Markers for Proton Beam Radiation of Choroidal Melanoma by an Opto-Electronic Navigation System: A Novel Technique

Purpose: External beam proton radiation therapy has been used since 1975 to treat choroidal melanoma. For tumor location determination during proton radiation treatment, surgical tantalum clips are registered with image data. This report introduces the intraoperative application of an opto-electronic navigation system to determine with high precision the position of the tantalum markers and their spatial relationship to the tumor and anatomical landmarks. The application of the technique in the first 4 patients is described. Methods and Materials: A navigated reference base was attached noninvasively to the eye, and a navigated pointer device was used to record the spatial position of the tantalum markers, the tumor, and anatomical landmarks. Measurement accuracy was assessed on ex vivo porcine eye specimen by repetitive recording of the tantalum marker positions. The method was applied intraoperatively on 4 patients undergoing routine tantalum clip surgery. The spatial position information delivered by the navigation system was compared to the geometric data generated by the EYEPLAN software. Results: In the ex vivo experiments, the maximum repetition error was 0.34 mm. For the intraoperative application, the root mean square error of paired-points matching of the marker positions from the navigation system and from the EYEPLAN software was 0.701-1.25 mm. Conclusions: Navigation systems are a feasible tool for accurate localization of tantalum markers and anatomic landmarks. They can provide additional geometric information, and therefore have the potential to increase the reliability and accuracy of external beam proton radiation therapy for choroidal melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensor Placement Optimization Study for the Built Environment: Next Steps Report

Systems of fixed-position radiation sensors can provide information that assists emergency responders following nuclear incidents. First responder organizations that implement systems of fixed-position sensors face numerous decisions regarding sensor selection, quantity, and placement. Researchers at Pacific Northwest National Laboratory (PNNL) have evaluated the performance of several hypothetical sensor systems during a simulated activation of a radiological dispersal device. Due to technical limitations, PNNL’s analysis was limited to a single location and number of scenarios. This document describes additional research and analysis that would result in improved guidance to first responder organizations considering installation of radiation monitoring systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DIY XES-development of an inexpensive, versatile, and easy to fabricate XES analyzer and sample delivery system

The application of X-ray emission spectroscopy (XES) has grown substantially with the development of X-ray free-electron lasers, third and fourth generation synchrotron sources, and high-power benchtop sources. By providing the high X-ray flux required for XES, these sources broaden the availability and application of this method of probing electronic structure. As the number of sources increase, so does the demand for X-ray emission detection and sample delivery systems that are cost effective and customizable. In this work, we present a detailed fabrication protocol for von Hamos X-ray optics and give details for a 3D-printed spectrometer design. Additionally, we outline an automated, externally triggered liquid sample delivery system that can be used to repeatedly deliver nanoliter droplets onto a plastic substrate for measurement. These systems are both low cost, efficient, and easy to recreate or modify depending on the application. A low cost multiple X-ray analyzer system enables measurement of dilute samples, whereas the sample delivery limits sample loss and reproducibly replaces spent sample with fresh sample in the same position. While both systems can be used in a wide range of applications, the design addresses several challenges associated specifically with time-resolved XES (TRXES). As an example application, we show results from TRXES measurements of photosystem II, a dilute, photoactive protein.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Observational Understanding of Connected Lighting Systems

As part of the Internet of Things (IoT), connected lighting systems provide additional control capabilities and nonlighting-related services (such as communications and data infrastructure) to reduce energy use while increasing both application efficiency and system value. But the positive or negative energy impact of implementing these systems is still largely unknown due to the variety of human factors associated with installation, maintenance, and use. These complications interfere with adoption and acceptance rates of products that will play a significant role in achieving energy savings long-term. Next Generation Lighting Systems, or NGLS, developed and implemented an observational research methodology for connected lighting systems. The methodology was implemented at an indoor (classroom/office) Living Lab at Parsons School of Design in New York City, and an outdoor (parking lot) Living Lab at Virginia Tech Transportation Institute in Blacksburg, Virginia. Although this report focuses on the approach to indoor installations, observational research in both settings provides insight to the type, scale, and frequency of issues across available products as experienced by installing contractors, end users, and other stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A real-time respiration position based passive breath gating equipment for gated radiotherapy: A preclinical evaluation

Purpose: To develop a passive gating system incorporating with the real-time position management (RPM) system for the gated radiotherapy. Methods: Passive breath gating (PBG) equipment, which consists of a breath-hold valve, a controller mechanism, a mouthpiece kit, and a supporting frame, was designed. A commercial real-time positioning management system was implemented to synchronize the target motion and radiation delivery on a linear accelerator with the patient's breathing cycle. The respiratory related target motion was investigated by using the RPM system for correlating the external markers with the internal target motion while using PBG for passively blocking patient's breathing. Six patients were enrolled in the preclinical feasibility and efficiency study of the PBG system. Results: PBG equipment was designed and fabricated. The PBG can be manually triggered or released to block or unblock patient's breathing. A clinical workflow was outlined to integrate the PBG with the RPM system. After implementing the RPM based PBG system, the breath-hold period can be prolonged to 15-25 s and the treatment delivery efficiency for each field can be improved by 200%-400%. The results from the six patients showed that the diaphragm motion caused by respiration was reduced to less than 3 mm and the position of the diaphragm was reproducible for difference gating periods. Conclusions: A RPM based PBG system was developed and implemented. With the new gating system, the patient's breath-hold time can be extended and a significant improvement in the treatment delivery efficiency can also be achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positive-Sequence Modeling of Droop-Controlled Grid-Forming Inverters for Transient Stability Simulation of Transmission Systems

Here, this paper describes a positive-sequence model to represent two widely reported droop-controlled grid-forming inverters for bulk power systems simulation study. Methods of how to develop the equivalent voltage source behind impedance to represent inverters with and without inner control loops, modeling of P-f and Q-V droop controls, active and reactive power limiting modeling, and modeling of fault current limiting controls are described in detail. The model is implemented in commercially available positive-sequence simulation tools and compared with detailed electromagnetic transient models in both a single-grid-forming-inverter infinite-bus system and a modified IEEE 39-bus system. Finally, the model is tested on the full US Western Electricity Coordinating Council (WECC) system. Study results show that the model has a good level of accuracy compared to the detailed EMT models, and at the same time also achieves a high computational efficiency, which is suitable for the bulk power system simulation study.

42 ENGINEERING↗

Hubbard model as an approximation to the entanglement in nanostructures

We investigate how well the one-dimensional Hubbard model describes the entanglement of particles trapped in a string of quantum wells. We calculate the average single-site entanglement for two particles interacting via a contact interaction and consider the effect of varying the interaction strength and the interwell distance. We compare the results with the ones obtained within the one-dimensional Hubbard model with on-site interaction. We suggest an upper bound for the average single-site entanglement for two electrons in M wells and discuss analytical limits for very large repulsive and attractive interactions. We investigate how the interplay between interaction and potential shape in the quantum-well system dictates the position and size of the entanglement maxima and the agreement with the theoretical limits. Finally, we calculate the spatial entanglement for the quantum-well system and compare it to its average single-site entanglement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ALD reactor for coating porous substrates

A system and method for improved atomic layer deposition. The system includes a top showerhead plate, a substrate and a bottom showerhead plate. The substrate includes a porous microchannel plate and a substrate holder is positioned in the system to insure flow-through of the gas precursor.

Mane, Anil U.↗

Application of 3D Code IBSimu for Designing an H{sup -}/D{sup -} Extraction System for the Texas A and M Facility Upgrade

A three dimensional ion optical code IBSimu is being developed at the University of Jyvaeskylae. So far the plasma modelling of the code has been restricted to positive ion extraction systems, but now a negative ion plasma extraction model has been added. The plasma model has been successfully validated with simulations of the Spallation Neutron Source (SNS) ion source extraction both in cylindrical symmetry and in full 3D, also modelling electron beam dumping and ion beam tilt. A filament-driven multicusp ion source has been installed at the Texas A and M University Cyclotron Institute for production of H{sup -} and D{sup -} beams as a part of the facility upgrade. The light ion beams, produced by the ion source, are accelerated with the K150 cyclotron for production and reacceleration of rare isotopes. The extraction system for the ion source was designed with IBSimu. The extraction features a water-cooled puller electrode with a permanent magnet dipole field for dumping the co-extracted electrons and a decelerating Einzel lens for adjusting the beam focusing for further beam transport. The ion source and the puller electrode are tilted at 4 degree angle with respect to the beam line. The extraction system can handle H{sup -} and D{sup -} beams with final beam energies from 5 keV to 15 keV using the same geometry, only adjusting the electrode voltages. So far, 24 {mu}A of H{sup -} and 15 {mu}A of D{sup -} have been extracted from the cyclotron.

43 PARTICLE ACCELERATORS↗

Unextendible product bases and extremal density matrices with positive partial transpose

In bipartite quantum systems of dimension 3x3, entangled states that are positive under partial transposition (PPT) can be constructed with the use of unextendible product bases (UPBs). As discussed in a previous publication, all the lowest rank entangled PPT states of this system seem to be equivalent, under SL x SL transformations, to states that are constructed in this way. Here we consider a possible generalization of the UPB constuction to low-rank entangled PPT states in higher dimensions. The idea is to give up the condition of orthogonality of the product vectors, while keeping the relation between the density matrix and the projection on the subspace defined by the UPB. We examine first this generalization for the 3x3 system where numerical studies indicate that one-parameter families of such generalized states can be found. Similar numerical searches in higher dimensional systems show the presence of extremal PPT states of similar form. Based on these results we suggest that the UPB construction of the lowest rank entangled states in the 3x3 system can be generalized to higher dimensions, with the use of nonorthogonal UPBs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lateral position detection and control for friction stir systems

Friction stir methods are disclosed for processing at least one workpiece using a rotary tool with rotating member for contacting and processing the workpiece. The methods include oscillating the rotary tool laterally with respect to a selected propagation path for the rotating member with respect to the workpiece to define an oscillation path for the rotating member. The methods further include obtaining force signals or parameters related to the force experienced by the rotary tool at least while the rotating member is disposed at the extremes of the oscillation. The force signals or parameters associated with the extremes can then be analyzed to determine a lateral position of the selected path with respect to a target path and a lateral offset value can be determined based on the lateral position. The lateral distance between the selected path and the target path can be decreased based on the lateral offset value.

42 ENGINEERING↗

Lateral position detection and control for friction stir systems

An apparatus and computer program are disclosed for processing at least one workpiece using a rotary tool with rotating member for contacting and processing the workpiece. The methods include oscillating the rotary tool laterally with respect to a selected propagation path for the rotating member with respect to the workpiece to define an oscillation path for the rotating member. The methods further include obtaining force signals or parameters related to the force experienced by the rotary tool at least while the rotating member is disposed at the extremes of the oscillation. The force signals or parameters associated with the extremes can then be analyzed to determine a lateral position of the selected path with respect to a target path and a lateral offset value can be determined based on the lateral position. The lateral distance between the selected path and the target path can be decreased based on the lateral offset value.

97 MATHEMATICS AND COMPUTING↗