Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precise timing electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

A New Cathode Material for a Li–O 2 Battery Based on Lithium Superoxide

Li–O 2 batteries suffer from large charge overpotentials due to the high charge transfer resistance of Li 2 O 2 discharge products. A potential solution to this problem is the development of LiO 2 -based batteries that possess low charge overpotentials due to the lower charge transfer resistance of LiO 2 . In this report, IrLi nanoparticles were synthesized and implemented for the first time as a LiO 2 battery cathode material. The IrLi nanoparticle synthesis was achieved by a temperature- and time-optimized thermal reaction between a precise ratio of iridium nanoparticles and lithium metal. Li–O 2 batteries employing the IrLi-rGO cathodes were cycled up to 100 cycles at moderate current densities with sustained low cell charge potentials (<3.5 V). Further, various characterization techniques, including SEM, DEMS, TEM, Raman, and titration, were used to demonstrate the LiO 2 discharge product and the absence of Li 2 O 2 . On the basis of first-principles calculations, it was concluded that the formation of crystalline LiO 2 can be stabilized by epitaxial growth on the (111) facets of IrLi nanoparticles present on the cathode surface. These findings demonstrate that, in addition to the previously studied Ir 3 Li intermetallic, the IrLi intermetallic also provides a means by which LiO 2 discharge products can be stabilized and confirms the importance of templating for the formation process.

25 ENERGY STORAGE↗

Mysterious SiB 3 : Identifying the Relation between α- and β-SiB 3

Binary silicon boride SiB 3 has been reported to occur in two forms, as disordered and nonstoichiometric α-SiB 3–x , which relates to the α-rhombohedral phase of boron, and as strictly ordered and stoichiometric β-SiB 3 . Similar to other boron-rich icosahedral solids, these SiB 3 phases represent potentially interesting refractory materials. However, their thermal stability, formation conditions, and thermodynamic relation are poorly understood. Here, we map the formation conditions of α-SiB 3–x and β-SiB 3 and analyze their relative thermodynamic stabilities. α-SiB 3–x is metastable (with respect to β-SiB 3 and Si), and its formation is kinetically driven. Pure polycrystalline bulk samples may be obtained within hours when heating stoichiometric mixtures of elemental silicon and boron at temperatures 1200–1300 °C. At the same time, α-SiB 3–x decomposes into SiB6 and Si, and optimum time-temperature synthesis conditions represent a trade-off between rates of formation and decomposition. The formation of stable β-SiB 3 was observed after prolonged treatment (days to weeks) of elemental mixtures with ratios Si/B = 1:1–1:4 at temperatures 1175–1200 °C. The application of high pressures greatly improves the kinetics of SiB 3 formation and allows decoupling of SiB 3 formation from decomposition. Quantitative formation of β-SiB 3 was seen at 1100 °C for samples pressurized to 5.5–8 GPa. β-SiB 3 decomposes peritectoidally at temperatures between 1250 and 1300 °C. The highly ordered nature of β-SiB 3 is reflected in its Raman spectrum, which features narrow and distinct lines. In contrast, the Raman spectrum of α-SiB 3–x is characterized by broad bands, which show a clear relation to the vibrational modes of isostructural, ordered B 6 P. The detailed composition and structural properties of disordered α-SiB 3–x were ascertained by a combination of single-crystal X-ray diffraction and 29 Si magic angle spinning NMR experiments. Notably, the compositions of polycrystalline bulk samples (obtained at T ≤ 1200 °C) and single crystal samples (obtained from Si-rich molten Si–B mixtures at T > 1400 °C) are different, SiB 2.93(7) and SiB 2.64(2) , respectively. The incorporation of Si in the polar position of B 12 icosahedra results in highly strained cluster units. This disorder feature was accounted for in the refined crystal structure model by splitting the polar position into three sites. The electron-precise composition of α-SiB 3–x is SiB 2.5 and corresponds to the incorporation of, on average, two Si atoms in each B 12 icosahedron. Accordingly, α-SiB 3–x constitutes a mixture of B 10 Si 2 and B 11 Si clusters. The structural and phase stability of α-SiB 3–x were explored using a first-principles cluster expansion. The most stable composition at 0 K is SiB 2.5 , which however is unstable with respect to the decomposition β-SiB 3 + Si. Modeling of the configurational and vibrational entropies suggests that α-SiB 3–x only becomes more stable than β-SiB 3 at temperatures above its decomposition into SiB 6 and Si. Hence, we conclude that α-SiB 3–x is metastable at all temperatures. Density functional theory electronic structure calculations yield band gaps of similar size for electron-precise α-SiB 2.5 and β-SiB 3 , whereas α-SiB 3 represents a p-type conductor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the Kaon Production Normalization in the NuMI Target Using Uncontained Charged-Current Muon Neutrino Interactions in the NOvA Far Detector

aNOvA is a long-baseline neutrino oscillation experiment that uses the NuMI beam from Fermilab. Its physics goals include providing constraints to the neutrino mass hierarchy and the CP-violating phase $\delta$ by precision measurements of the electron (anti)neutrino appearance in a muon (anti)neutrino beam. Similarly, new limits on the values of $\sin^2{\theta_{23}}$ and $\Delta m^{2}_{32}$ will be achieved by measurements of the muon (anti)neutrino disappearance probabilities. A combined analysis measurement will allow a better resolution of the $\theta_{23}$ octant. The NuMI beam is produced by the collision of high energy protons into a target, giving rise to kaon and pion mesons that decay to neutrinos of a specific flavor. This thesis presents a measurement of the kaon production normalization scale using uncontained charged-current muon neutrinos at the Far Detector. Because the neutrino beam is not pure in flavor, it contains an admixture of other different n eutrino flavors that become a source of background. %in oscillation analysis. Therefore, it is of paramount importance for accelerator experiments, such as NOvA, to have a reliable flux prediction of the neutrino beam in order to achieve its physics goals. One method to constrain the flux is to constrain and measure each flux component independently. The kaon component contributes to the intrinsic $\nu_{e}$ contamination of the beam, a key background for the $\nu_{e}$-appearance analysis. We observed that the uncontained sample in the 10-20 GeV region corresponds to the kaon component of the NuMI beam at the Far Detector. We also found a 60-80\% correlation between the Near Detector $\nu_{e}$ background and the Far Detector $\nu_{\mu}$ uncontained signal. The data used for this analysis was collected from October 2014 to February 2017, corresponding to $7.99 \times 10^{20}$ protons-on-target (POT). The ratio between the Far Detector data and the simulation is fitted to a lin e in the 10-20 GeV energy region. Calibration, energy scale,! final state interactions and neutrino flux (e.g. beam transport and hadron production shape only) systematic uncertainties are considered. The kaon production normalization scale is measured to be $S_{K} = 1.07 \pm 0.16$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Calibration System of the E989 Experiment at Fermilab

The muon anomaly aµ is one of the most precise quantity known in physics experimentally and theoretically. The high level of accuracy permits to use the measurement of aµ as a test of the Standard Model comparing with the theoretical calculation. After the impressive result obtained at Brookhaven National Laboratory in 2001 with a total accuracy of 0.54 ppm, a new experiment E989 is under construction at Fermilab, motivated by the diff of aexp SM µ − aµ ∼ 3σ. The purpose of the E989 experiment is a fourfold reduction of the error, with a goal of 0.14 ppm, improving both the systematic and statistical uncertainty. With the use of the Fermilab beam complex a statistic of × 21 with respect to BNL will be reached in almost 2 years of data taking improving the statistical uncertainty to 0.1 ppm. Improvement on the systematic error involves the measurement technique of ωa and ωp, the anomalous precession frequency of the muon and the Larmor precession frequency of the proton respectively. The measurement of ωp involves the magnetic field measurement and improvements on this sector related to the uniformity of the field should reduce the systematic uncertainty with respect to BNL from 170 ppb to 70 ppb. A reduction from 180 ppb to 70 ppb is also required for the measurement of ωa; new DAQ, a faster electronics and new detectors and calibration system will be implemented with respect to E821 to reach this goal. In particular the laser calibration system will reduce the systematic error due to gain fl of the photodetectors from 0.12 to 0.02 ppm. The 0.02 ppm limit on systematic requires a system with a stability of 10−4 on short time scale (700 µs) while on longer time scale the stability is at the percent level. The 10−4 stability level required is almost an order of magnitude better than the existing laser calibration system in particle physics, making the calibration system a very challenging item. In addition to the high level of stability a particular environment, due to the presence of a 14 m diameter storage ring, a highly uniform magnetic field and the detector distribution around the storage ring, set specific guidelines and constraints. This thesis will focus on the final design of the Laser Calibration System developed for the E989 experiment. Chapter 1 introduces the subject of the anomalous magnetic moment of the muon; chapter 2 presents previous measurement of g-2, while chapter 3 discusses the Standard Model prediction and possible new physics scenario. Chapter 4 describes the E989 experiment. In this chapter will be described the experimental technique and also will be presented the experimental apparatus focusing on the improvements necessary to reduce the statistical and systematic errors. The main item of the thesis is discussed in the last two chapters: chapter 5 is focused on the Laser Calibration system while chapter 6 describes the Test Beam performed at the Beam Test Facility of Laboratori Nazionali di Frascati from the 29th February to the 7th March as a final test for the full calibrations system. An introduction explain the physics motivation of the system and the diff t devices implemented. In the final chapter the setup used will be described and some of the results obtained will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade

We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Consumption study and identification of methyl salicylate in spicy cassava chips

Spicy cassava chips is a popular snack. However, some news in electronic media reported addition of balsam which is a banned food additives in that product to give extra spicy flavor. This study aimed to determine ITB students’ pattern of consumption, health problems caused by spicy chips consumption, and knowledge about illicit use of food additives in that product, and identify the main content of balsam namely methyl salicylate in 10 samples of spicy cassava chips taken from inside and outside about ITB campus. A total of 300 questionnaires distributed to ITB students then data processing was performed. Spicy cassava chips sample macerated in 50 mL of methanol for 24 hours at room temperature, filtered and analyzed using gas chromatography capillary column with OV-1, nitrogen carrier gas and flame ionization detector. Based on questionnaires, 292 (97%) of 300 respondents had consumed spicy chips. A total of 247 (85%) from 292 respondents spicy chips consumed less than 3 times a week. A total of 195 respondents (67%) had experienced health problems after eating spicy chips. There were 137 (47%) of the 292 respondents who knew about the illicit addition of food additives into spicy chips; only 35 respondents (12%) who knew about balsam’s addition. There were 126 respondents (43%) who did not pay attention to their health because they will keep eating spicy chips despite the addition of banned food additives. Through the verification of the standard addition method in gas chromatography system with a hydrogen pressure of 1.5 bar, injector temperature 200 °C, detector temperature 230 °C, oven temperature 60 °C for 2 minutes and then increased to 230 °C with rate 6 °C/menit; linearity, limit of detection, limit of quantitation, accuracy, precision, and specificity parameters met the acceptance limits. From 10 spicy cassava chips samples which were analyzed, they did not reveal any content of methyl salicylate. Methyl salicylate contained in the positive control was 1.273 mg/mL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Half-life determination of heavy ions in a storage ring considering feeding and depleting background processes

Heavy-ion storage rings have relatively large momentum acceptance which allows for multiple ion species to circulate at the same time. This needs to be considered in radioactive decay measurements of highly charged ions, where atomic charge exchange reactions can significantly alter the intensities of parent and daughter ions. In this study, we investigate this effect using the decay curves of ion numbers in the recent 205 Tl 81+ bound-state beta decay experiment conducted using the Experimental Storage Ring at GSI Darmstadt. To understand the intricate dynamics of ion numbers, we present a set of differential equations that account for various atomic and nuclear reaction processes—bound state beta decay, atomic electron recombination and capture, and electron ionization. By incorporating appropriate boundary conditions, we develop a set of differential equations that accurately simulate the decay curves of various simultaneously stored ions in the storage ring: 205 Tl 81+ , 205 Pb 81+ , 205 Pb 82+ , 200 Hg 79+ , and 200 Hg 80+ . Through a quantitative comparison between simulations and experimental data, we provide insights into the detailed reaction mechanisms governing stored heavy ions within the storage ring. Our approach effectively models charge-changing processes, reduces the complexity of the experimental setup, and provides a simpler method for measuring the decay half-lives of highly charged ions in storage rings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A micron resolution optical scanner for characterization of silicon detectors

The emergence of high position resolution (∼10 μm) silicon detectors in recent times have highlighted the urgent need for the development of new automated optical scanners of micron level resolution suited for characterizing microscopic features of these detectors. More specifically, for the newly developed silicon photo-multipliers (SiPM) that are compact, possessing excellent photon detection efficiency with gain comparable to photo-multiplier tube. In a short time, since their invention the SiPMs are already being widely used in several high-energy physics and astrophysics experiments as the photon readout element. The SiPM is a high quantum efficiency, multi-pixel photon counting detector with fast timing and high gain. The presence of a wide variety of photo sensitive silicon detectors with high spatial resolution requires their performance evaluation to be carried out by photon beams of very compact spot size. We have designed a high resolution optical scanner that provides a monochromatic focused beam on a target plane. The transverse size of the beam was measured by the knife-edge method to be 1.7 μm at 1 − σ level. Since the beam size was an order of magnitude smaller than the typical feature size of silicon detectors, this optical scanner can be used for selective excitation of these detectors. The design and operational details of the optical scanner, high precision programmed movement of target plane (0.1 μm) integrated with general purpose data acquisition system developed for recording static and transient response photo sensitive silicon detector are reported in this paper. Entire functionality of scanner is validated by using it for selective excitation of individual pixels in a SiPM and identifying response of active and dead regions within SiPM. Results from these studies are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward quantifying capacity losses due to solid electrolyte interphase evolution in silicon thin film batteries

To understand the origins of failure and limited cycle life in lithium-ion batteries (LIBs), it is imperative to quantitatively link capacity-fading mechanisms to electrochemical and chemical processes. This is extremely challenging in real systems where capacity is lost during each cycle to both active material loss and solid electrolyte interphase (SEI) evolution, two indistinguishable contributions in traditional electrochemical measurements. Here, we have used a model system in combination with (1) precision measurements of the overall Coulombic efficiency via electrochemical experiments and (2) x-ray reflectivity measurements of the active material losses. The model system consisted of a 515 Å thick amorphous silicon (a-Si) thin film on silicon carbide in half-cell geometry using a carbonate electrolyte with LiPF6 salt. This approach allowed us to quantify the capacity lost during each cycle due to SEI evolution. Combined with electrochemical analysis, we identify SEI growth as the major contribution to capacity fading. Specifically, the continued SEI growth results in increasing overpotentials due to increased SEI resistance, and this leads to lower extent of lithiation when the cutoff voltage is reached during lithiation. Our results suggest that SEI grows more with increased time spent at low voltages where electrolyte decomposition is favored. Finally, we extracted a proportionality constant for SEI growth following a parabolic growth law. Our methodology allows for the quantitative determination of lithium-ion loss mechanisms in LIBs by separately tracking lithium ions within the active materials and the SEI and offers a powerful method of quantitatively understanding LIB loss mechanisms.

25 ENERGY STORAGE↗

A novel liquid argon purity monitor based on 207 Bi

A novel liquid argon purity monitor based on a 207 Bi radioactive source, emitting monochromatic internal-conversion electrons, is presented. This new monitor allows for a very precise and fast measurement of the electronegative impurities concentration in liquid argon. It can be operated continuously in liquid argon TPC experiments without interfering with the main detector operation. Different drift lengths can be assembled for the proposed device, to assess a large range of liquid argon purities while minimizing systematic uncertainties. Two prototypes have been built and successfully operated in dedicated test stands. The results and performance are reported.

double-phase↗

Multihelix rotating shield brachytherapy for cervical cancer

Purpose: To present a novel brachytherapy technique, called multihelix rotating shield brachytherapy (H-RSBT), for the precise angular and linear positioning of a partial shield in a curved applicator. H-RSBT mechanically enables the dose delivery using only linear translational motion of the radiation source/shield combination. The previously proposed approach of serial rotating shield brachytherapy (S-RSBT), in which the partial shield is rotated to several angular positions at each source dwell position [W. Yang et al., “Rotating-shield brachytherapy for cervical cancer,” Phys. Med. Biol. 58, 3931–3941 (2013)], is mechanically challenging to implement in a curved applicator, and H-RSBT is proposed as a feasible solution. Methods: A Henschke-type applicator, designed for an electronic brachytherapy source (Xoft Axxent™) and a 0.5 mm thick tungsten partial shield with 180° or 45° azimuthal emission angles and 116° asymmetric zenith angle, is proposed. The interior wall of the applicator contains six evenly spaced helical keyways that rigidly define the emission direction of the partial radiation shield as a function of depth in the applicator. The shield contains three uniformly distributed protruding keys on its exterior wall and is attached to the source such that it rotates freely, thus longitudinal translational motion of the source is transferred to rotational motion of the shield. S-RSBT and H-RSBT treatment plans with 180° and 45° azimuthal emission angles were generated for five cervical cancer patients with a diverse range of high-risk target volume (HR-CTV) shapes and applicator positions. For each patient, the total number of emission angles was held nearly constant for S-RSBT and H-RSBT by using dwell positions separated by 5 and 1.7 mm, respectively, and emission directions separated by 22.5° and 60°, respectively. Treatment delivery time and tumor coverage (D{sub 90} of HR-CTV) were the two metrics used as the basis for evaluation and comparison. For all the generated treatment plans, the D{sub 90} of the HR-CTV in units of equivalent dose in 2 Gy fractions (EQD2) was escalated until the D{sub 2cc} (minimum dose to hottest 2 cm{sup 3}) tolerance of either the bladder (90 Gy{sub 3}), rectum (75 Gy{sub 3}), or sigmoid colon (75 Gy{sub 3}) was reached. Results: Treatment time changed for H-RSBT versus S-RSBT by −7.62% to 1.17% with an average change of −2.8%, thus H-RSBT treatments times tended to be shorter than for S-RSBT. The HR-CTV D{sub 90} also changed by −2.7% to 2.38% with an average of −0.65%. Conclusions: H-RSBT is a mechanically feasible delivery technique for use in the curved applicators needed for cervical cancer brachytherapy. S-RSBT and H-RSBT were clinically equivalent for all patients considered, with the H-RSBT technique tending to require less time for delivery.

60 APPLIED LIFE SCIENCES↗

Study of the Mu2e sensitivity to the $\mu^-\rightarrow e^+$ conversion process

The Mu2e experiment at Fermilab (Batavia, IL) will search for the coherent neutrinoless conversion of a muon into an electron in the electric field of an aluminum atom. The conversion process results in a monochromatic electron with energy slightly below the muon rest mass ($E_e= 104.97$ MeV). The experiment goal is to improve the previous measurement by four orders of magnitude and reach a single event sensitivity of $3 \times 10^{-17} $ on the conversion rate with respect to the muon capture rate. \\ The experiment will deliver a very intense pulsed negative muon beam to an aluminum target to achieve a total number of $10^{18}$ stopped muons in three years of running. Production and transport of the muons are accomplished with a sophisticated magnetic system comprised of a Production, a Transport and a Detector solenoid, with the last one hosting a Straw-tube Tracker and a Crystal Calorimeter. The entire detector region is surrounded by a Cosmic Ray Veto system. Mu2e is und er construction at the Muon Campus of Fermilab. \\ The INFN italian group is responsible for the design and construction of the crystal calorimeter, which plays a crucial role in the Mu2e measurement, providing particle identification capabilities fundamental for the rejection of the different background sources that can mimic a conversion electron. The calorimeter information allows also to improve the tracking performances it provides a fast standalone trigger for the experiment.\\ After a long R\&D phase, the final drawings see a calorimeter comprised of 1348 pure CsI crystals arranged in two annular disks. Each crystal is readout by two custom UV-extended Silicon Photomultipliers (SiPMs). Performances of the selected components were verified with an electron beam test, carried out in 2017 at the Beam Test Facility (BTF) at the National Laboratories of Frascati, on a large size prototype of 51 crystals and 102 SiPMs, confirming excellent energy ($\sigma_{E}/E = \mathcal{O }(10\%)$) and timing ($\sigma_{T} <500$ ps) resolutions in a! greement with the Mu2e specifications.\\ In the first chapters of this thesis, I describe my involvement in the calorimeter activities, with particular emphasis on the data analysis of the prototype energy response and resolution, that I was personally leading. Moreover, a description of the tuning of the simulation and the careful data-MC comparison is also reported.\\ An auxiliary measurement that can be performed with Mu2e is the search for a Lepton Number Violation (LNV) process where the negatively charged muon converts, without neutrinos, into a positron, $\mu ^{-} +N(A,Z) \rightarrow $ e$^+ +N(A,Z-2)$. At the moment of writing, Neutrinoless Double Beta Decay (0$\nu \beta \beta$) has set the most stringent limit on the LNV processes (T$^{0\nu \beta \beta}_{1/2} > 1.1 \times 10^{26} $ yr at 90$\%$ CL) with the GERDA experiment. In 0$\nu \beta \beta$ a pair of free electrons is created in the transformation from a nucleus $(A, Z)$ into its daughter $(A, Z + 2)$, namely: $(A,Z)\rightarrow (A, Z+2) =2 e^-$. Similar transitions could proceed through the emission of a pair of positrons, double electron capture (EC), or EC and single emission of a positron, with the nucleus changing from $(A, Z)$ to $(A, Z - 2)$. All these variations are equally interesting when discussing of new Physics, since they all manifest a non-conservation of the number of leptons.\\ Moreover, recent studies show that, because of flavor effect, off-diagonal processes, such as the $\mu^- -e^+$ conversion, can have their rate enhanced with respect to processes occurring in the $e-e$ sector.\\ Mu2e will search for $\mu^- + Al(27,13) \rightarrow e^+ +Na(27,11)$, only considering ground state transition, producing a conversion positron with energy $E_{e^+}= 92.32 $ MeV.\\ This thesis is focused on this search. In particular, I developed an algorithm to account for the radiative corrections to be applied to the conversion positrons that resulted in a few percent reduction in s ignal acceptance.\\ One of the most prominent background to ! this sear! ch is the Radiative Muon Capture (RMC) $ \mu+ N(Z,A)\rightarrow \gamma + \nu_{\mu} + N(Z-1,A)$. The produced photon can convert, virtually or in the detector materials (in the following referred as internal or external conversion respectively) in an electron-positron pair, producing positrons with energies approaching the expected conversion energy. Experimental results from previous experiments indicate the RMC endpoint ($\kmax$) to be of $\sim$ 90 MeV. A precise modeling of this background is relevant due to the proximity of the photon spectrum endpoint to the positron conversion energy. The calorimeter group is obviously interested to reconstruct the RMC distribution having also the opportunity to improve the current knowledge of the process. \\ A toy MC has been developed to evaluate the number of $e^+$ from external RMC background in the signal window. Knowing this value and ev...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Describing Point Defect Topology in 2D Energy Materials Through Computer Vision

Point defects such as vacancies and impurity atoms strongly impact the performance of 2D materials. Traditional efforts often rely on manual detection, a process that is time-intensive, prone to human error, and challenging to scale. Here we leverage machine learning (ML) methods to identify and quantify vacancies within 2D transition metal carbides (Ti3C2, MXenes), aiming to expedite detection while improving accuracy. MXenes exhibit valuable defect-defined electrochemical properties, but we currently lack statistical understanding of defect topology needed to fully harness these materials. Here we employ a convolutional neural network for semantic segmentation of experimental MXene images, opening an opportunity to conduct a rigorous statistical study on defect hierarchy while investigating local relaxation in the lattice. We show how the integration of ML can yield fundamental insight into point defects, providing a powerful tool that will play an increasingly crucial role in the future of materials science. ML is often not just a matter of straightforward application, and pretrained models proved ineffective in this case. Instead, we trained our own neural network (NN) and applied data augmentation techniques and fine-tuning to the training dataset. Since labeled microscopy data is often scarce, we developed training data from a previously published wide-frame MXene image, using customized Gaussian fitting to locate atomic positions. Our trained model was then applied to a large dataset of experimental images, enabling a statistical study of defect configurations across three samples prepared with different HF etchant concentrations (5%, 9.1%, and 12.5%), as shown in Fig. 1. This also allowed us to investigate local strain around vacancies, though we find that we are limited by the precision of measurements using high-angle annular dark field (HAADF) images, as shown in Fig. 2. This study demonstrates how ML enables large-scale, quantitative analysis of atomic defects - an otherwise infeasible task with traditional methods. While our NN was specialized for Ti3C2 MXenes, the pipeline we developed provides a foundation for future ML models tailored to other materials. Ultimately, we envision embedding the NN onto the microscope to give real-time feedback to the user. To make this a reality, continued work is necessary to fully understand the NN's capabilities and limitations. This study gets one step closer to our goals of automated experimentation moving away from traditional methods of manual labeling. As ML capabilities advance, we hope to continue adapting and applying these techniques in microscopy.

2D materials↗

Spectroscopic Investigation of p-Shell Lambda Hypernuclei by the (e,e'K + ) Reaction

Hypernuclear spectroscopy is a powerful tool to investigate Lambda-N interaction. Compared with other Lambda hypernuclei productions, electroproduction via the (e,e'K+) reaction has the advantage of exciting states deeply inside of the hypernucleus and achieving sub-MeV energy resolution. The E05-115 experiment, which was successfully performed in 2009, is the third generation hypernuclear experiment in JLab Hall C. A new splitter magnet and electron spectrometer were installed, and beam energy of 2.344 GeV was selected in this experiment. These new features gave better field uniformity, optics quality and made the tilt method more effective in improving yield-to-background ratio. The magnetic optics of the spectrometers were carefully studied with GEANT simulation, and corrections were applied to compensate for the fringe field cross talk between the compact spectrometer magnets. The non-linear least chi-squared method was used to further calibrate the spectrometer with the events from Lambda, Sigma0 and B12Lambda and uniform magnetic optics as well as precise kinematics were achieved. Several p-shell Lambda hypernuclear spectra, including B 12 Λ , Be 10 Λ , He 7 Λ , were obtained with high energy resolution and good accuracy. For B 12 Λ , eight peaks were recognized with the resolution of ~540keV (FWHM), and the ground state binding energy was obtained as 11.529 ± 0.012(stat.) ± 0.110(syst.) MeV. Be 10 Λ , twelve peaks were recognized with the resolution of ~520keV (FWHM), and the binding energy of the ground state was determined as 8.710 ± 0.059(stat.) ± 0.114(syst.) MeV. For He 7 Λ , three peaks were recognized with the resolution of ~730keV, and the ground state binding energy was obtained as 5.510 ± 0.050(stat.) ± 0.120(syst.) MeV. Compared with the published data of B 12 Λ from the JLab Hall A experiment, four extra peaks were fitted and interpreted thanks to the highest ever energy resolution and sufficient statistics. The determined binding energy of Be 10 Λ provides new information on charge symmetry breaking effect in the Lambda-N interaction. Compared with the results of He7Lambda from the E01-011 experiment, the ground state position is consistent with 4 times more statistics, and two extra peaks corresponding to excited states were recognized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diversity in Photoprotection and Energy Balancing in Terrestrial and Aquatic Phototrophs

The evolution of oxygenic photosynthesis enabled organisms to use sunlight as an energy source, allowing them to colonize new niches. At the same time, life (as we know it) places severe constraints on photosynthesis. For example, the initial reactions of photosynthesis involve highly energetic intermediates that, if not controlled, can generate highly toxic side products (especially reactive oxygen species, ROS), that can damage other essential components of the organisms it powers. Photosynthesis must therefore be tightly regulated to balance the need for efficient energy conversion with the necessity of avoiding photodamage (Gust D, Kramer D, Moore A, Moore T, Vermaas W, Mater Res Bull 33:383–389, 2008). A related constraint on photosynthesis is the need to precisely balance how much energy is stored in ATP and NADPH to precisely meet biochemical demands. If this balancing does not occur, the system will fail, leading to photodamage (Kramer DM, Evans JR, Plant Physiol 155:70–78, 2011). Consideration of these requirements is essential for efforts to improve the efficiency of photosynthesis by introducing CO 2 concentrating mechanisms, altering metabolism or biosynthetic pathways to shunt energy to alternative products (Kramer DM, Evans JR, Plant Physiol 155:70–78, 2011). These balancing processes must be extremely robust to contend with the rapid and unpredictable fluctuations in environmental conditions and metabolic demands that occur in nature. A large body of work has come from model systems, especially terrestrial higher plants and the green alga Chlamydomonas reinhardtii, leading to a model for the regulation of light reactions that involves 1) sensing of the pH gradient component of the thylakoid proton motive force (pmf), and 2) the redox state of the plastoquinone- and stromal pools. Over the short term, these sensors trigger regulation of light capture by altering the activity of ATP synthase leading to adjustments in lumen pH, which fine tunes light capture through nonphotochemical quenching (NPQ) and control of electron flow by adjusting the rate of PQH 2 oxidation at the b 6 f complex. Simultaneously, this system controls the balance of ATP/NADPH by adjusting electron flux to linear and cyclic electron flow pathways to balance ATP/NADPH. This integrated “pmf paradigm” model explains much of the existing data on plants and green algae, but may not extend to other diverse organisms. This review considers how advances in our understanding of photosynthesis over the past 7–8 years, particularly in the discoveries of diverse biochemical/biophysical mechanisms in aquatic photosynthetic species, affects the view of energy balance, including the shunting of electrons to O 2 through the flavodiiron proteins (FLV), the plastid terminal oxidase, the dissipation of electric field by ion movements, and the activation of alternative electron sinks. Furthermore, we will introduce the basic model that has been developed for higher plant chloroplasts, then contrast these with selected aquatic systems, focusing on how the differences impact the needs to re-balance both energy input and its partitioning into energy currencies.

Kanazawa, Atsuko↗

Evidence for anti-synergism between ion-assisted etching and in-plasma photoassisted etching of silicon in a high-density chlorine plasma

Etching of p-Si in 60 mTorr 10%Cl2/90%Ar Faraday-shielded inductively coupled high density plasmas was investigated under both ionassisted etching (IAE) and photoassisted etching (PAE) conditions. Real-time etching rates and after-etching Si surface chemical compositions were obtained by laser interferometry and vacuum-transfer x-ray photoelectron spectroscopy (XPS), respectively. Precisely controlled ion energy distributions (IEDs) were generated by applying pulsed negative DC bias on the conductive sample stage. Above a 36 eV threshold at a total flow rate of 250 SCCM, the IAE rate increased with the square root of the ion energy. In contrast to the DC bias, etching under RF bias did not exhibit a threshold ion energy because of the wide IED. XPS spectra revealed that the surface layer under PAE conditions had a significantly lower chlorine content, composed of only SiCl. Under IAE conditions, however, silicon dangling bonds (Si•), SiCl 2 , and SiCl 3 were found on the surface, in addition to SiCl, with a relative abundance of SiCl > SiCl 2 , and SiCl 3 . The absence of higher chlorides and Si• under PAE conditions suggested that vacuum ultraviolet photons and above threshold-energy ions interact with the surface very differently. By varying the duty cycle of the pulsed DC bias, it was found that the IAE rate scaled with the energetic ion dose, but only for low duty cycles. For higher duty cycles, the apparent IAE yield fell off with an increasing Cl coverage on the surface, as the duty cycle went up, which pointed to a negative synergy (antisynergism) between PAE and IAE as the explanation. This antisynergism was further supported by the observed decrease of the total etching rate with an increasing period of the pulsed DC bias. A plausible mechanism is that increasing the pulsing period causes more near-surface damage, creating more recombination centers that lead to a higher loss rate of electron-hole pairs through recombination, thereby reducing the PAE rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Optics for BES Light Source Facilities

Each new generation of synchrotron radiation sources has delivered an increase in average brightness 2 to 3 orders of magnitude over the previous generation. The next evolution toward diffraction-limited storage rings will deliver another 3 orders of magnitude increase. For ultrafast experiments, free electron lasers (FELs) deliver 10 orders of magnitude higher peak brightness than storage rings. Our ability to utilize these ultrabright sources, however, is limited by our ability to focus, monochromate, and manipulate these beams with X-ray optics. X-ray optics technology unfortunately lags behind source technology and limits our ability to maximally utilize even today’s X-ray sources. With ever more powerful X-ray sources on the horizon, a new generation of X-ray optics must be developed that will allow us to fully utilize these beams of unprecedented brightness. The increasing brightness of X-ray sources will enable a new generation of measurements that could have revolutionary impact across a broad area of science, if optical systems necessary for transporting and analyzing X-rays can be perfected. The high coherent flux will facilitate new science utilizing techniques in imaging, dynamics, and ultrahigh-resolution spectroscopy. For example, zone-plate-based hard X-ray microscopes are presently used to look deeply into materials, but today’s resolution and contrast are restricted by limitations of the current lithography used to manufacture nanodiffractive optics. The large penetration length, combined in principle with very high spatial resolution, is an ideal probe of hierarchically ordered mesoscale materials, if zone-plate focusing systems can be improved. Resonant inelastic X-ray scattering (RIXS) probes a wide range of excitations in materials, from charge-transfer processes to the very soft excitations that cause the collective phenomena in correlated electronic systems. However, although RIXS can probe high-energy excitations, the most exciting and potentially revolutionary science involves soft excitations such as magnons and phonons; in general, these are well below the resolution that can be probed by today’s optical systems. The study of these low-energy excitations will only move forward if advances are made in high-resolution gratings for the soft X-ray energy region, and higher-resolution crystal analyzers for the hard X-ray region. In almost all the forefront areas of X-ray science today, the main limitation is our ability to focus, monochromate, and manipulate X-rays at the level required for these advanced measurements. To address these issues, the U.S. Department of Energy (DOE) Office of Basic Energy Sciences (BES) sponsored a workshop, X-ray Optics for BES Light Source Facilities, which was held March 27–29, 2013, near Washington, D.C. The workshop addressed a wide range of technical and organizational issues. Eleven working groups were formed in advance of the meeting and sought over several months to define the most pressing problems and emerging opportunities and to propose the best routes forward for a focused R&D program to solve these problems. The workshop participants identified eight principal research directions (PRDs), as follows: Development of advanced grating lithography and manufacturing for high-energy resolution techniques such as soft X-ray inelastic scattering. Development of higher-precision mirrors for brightness preservation through the use of advanced metrology in manufacturing, improvements in manufacturing techniques, and in mechanical mounting and cooling. Development of higher-accuracy optical metrology that can be used in manufacturing, verification, and testing of optomechanical systems, as well as at wavelength metrology that can be used for quantification of individual optics and alignment and testing of beamlines. Development of an integrated optical modeling and design framework that is designed and maintained specifically for X-ray optics. Development of nanolithographic techniques for improved spatial resolution and efficiency of zone plates. Development of large, perfect single crystals of materials other than silicon for use as beam splitters, seeding monochromators, and high-resolution analyzers. Development of improved thin-film deposition methods for fabrication of multilayer Laue lenses and high-spectral-resolution multilayer gratings. Development of supports, actuator technologies, algorithms, and controls to provide fully integrated and robust adaptive X-ray optic systems. Development of fabrication processes for refractive lenses in materials other than silicon. The workshop participants also addressed two important nontechnical areas: our relationship with industry and organization of optics within the light source facilities. Optimization of activities within these two areas could have an important effect on the effectiveness and efficiency of our overall endeavor. These are crosscutting managerial issues that we identified as areas that needed further in-depth study, but they need to be coordinated above the individual facilities. Finally, an issue that cuts across many of the optics improvements listed above is routine access to beamlines that ideally are fully dedicated to optics research and/or development. The success of the BES X-ray user facilities in serving a rapidly increasing user community has led to a squeezing of beam time for vital instrumentation activities. Dedicated development beamlines could be shared with other R&D activities, such as detector programs and novel instrument development. In summary, to meet the challenges of providing the highest-quality X-ray beams for users and to fully utilize the high-brightness sources of today and those that are on the horizon, it will be critical to make strategic investments in X-ray optics R&D. This report can provide guidance and direction for effective use of investments in the field of X-ray optics and potential approaches to develop a better-coordinated program of X-ray optics development within the suite of BES synchrotron radiation facilities. Due to the importance and complexity of the field, the need for tight coordination between BES light source facilities and with industry, as well as the rapid evolution of light source capabilities, the workshop participants recommend holding similar workshops at least biannually.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis

Wearable sweat sensing is a rapidly rising research area driven by its promising potential in health, fitness, and diagnostic applications. Despite the growth in the field, major challenges in relation to sweat metrics remain to be addressed. These challenges include sweat rate monitoring for its complex relation with sweat compositions and sweat sampling for sweat dynamics studies. Here, we present a flexible microfluidic sweat sensing patch that enhances real-time electrochemical sensing and sweat rate analysis via sweat sampling. The device contains a spiral-patterned microfluidic component that is embedded with ion-selective sensors and an electrical impedance-based sweat rate sensor on a flexible plastic substrate. The patch is enabled to autonomously perform sweat analysis by interfacing the sensing component with a printed circuit board that is capable of on-site signal conditioning, analysis, and transmission. Progressive sweat flow in the microfluidic device, governed by the pressure induced by the secreted sweat, enhances sweat sampling and electrochemical detection via a defined sweat collection chamber and a directed sweat route. The characteristic of the sweat rate sensor is validated through a theoretical simulation, and the precision and accuracy of the flow rate is verified with a commercial syringe pump and a Macroduct sweat collector. On-body simultaneous monitoring of ion (H + , Na + , K + , Cl – ) concentration and sweat rate is also demonstrated for sensor functionality. This sweat sensing patch provides an integrated platform for a comprehensive sweat secretion analysis and facilitates physiological and clinical investigations by closely monitoring interrelated sweat parameters.

47 OTHER INSTRUMENTATION↗