Search NASA⌕ Search

SEARCH · Search NASA

Results for “data analysis methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

A convergence analysis of stochastic collocation method for Navier-Stokes equations with random input data

Stochastic collocation method has proved to be an efficient method and been widely applied to solve various partial differential equations with random input data, including Navier- Stokes equations. However, up to now, rigorous convergence analyses are limited to linear elliptic and parabolic equations; its performance for Navier-Stokes equations was demonstrated mostly by numerical experiments. In this paper, we provide an error analysis of stochastic collocation method for a semi-implicit Backward Euler discretization for NSE and prove the exponential decay of the interpolation error in the probability space. Our analysis indicates that due to the nonlinearity, as final time T increases and NSE solvers pile up, the accuracy may be reduced significantly. Subsequently, the theoretical results are illustrated by the numerical test of time dependent fluid flow around a bluff body.

97 MATHEMATICS AND COMPUTING↗

Upper mantle structure of central and West Antarctica from array analysis of Rayleigh wave phase velocities

Abstract The seismic velocity structure of Antarctica is important, both as a constraint on the tectonic history of the continent and for understanding solid Earth interactions with the ice sheet. We use Rayleigh wave array analysis methods applied to teleseismic data from recent temporary broadband seismograph deployments to image the upper mantle structure of central and West Antarctica. Phase velocity maps are determined using a two–plane wave tomography method and are inverted for shear velocity using a Monte Carlo approach to estimate three‐dimensional velocity structure. Results illuminate the structural dichotomy between the East Antarctic Craton and West Antarctica, with West Antarctica showing thinner crust and slower upper mantle velocity. West Antarctica is characterized by a 70–100 km thick lithosphere, underlain by a low‐velocity zone to depths of at least 200 km. The slowest anomalies are beneath Ross Island and the Marie Byrd Land dome and are interpreted as upper mantle thermal anomalies possibly due to mantle plumes. The central Transantarctic Mountains are marked by an uppermost mantle slow‐velocity anomaly, suggesting that the topography is thermally supported. The presence of thin, higher‐velocity lithosphere to depths of about 70 km beneath the West Antarctic Rift System limits estimates of the regionally averaged heat flow to less than 90 mW/m 2 . The Ellsworth‐Whitmore block is underlain by mantle with velocities that are intermediate between those of the West Antarctic Rift System and the East Antarctic Craton. We interpret this province as Precambrian continental lithosphere that has been altered by Phanerozoic tectonic and magmatic activity.

Heeszel, David S.↗

DES science portal: Creating science-ready catalogs

We present a novel approach for creating science-ready catalogs through a software infrastructure developed for the Dark Energy Survey (DES). We integrate the data products released by the DES Data Management and additional products created by the DES collaboration in an environment known as DES Science Portal. Each step involved in the creation of a science-ready catalog is recorded in a relational database and can be recovered at any time. We describe how the DES Science Portal automates the creation and characterization of lightweight catalogs for DES Year 1 Annual Release, and show its flexibility in creating multiple catalogs with different inputs and configurations. Finally, we discuss the advantages of this infrastructure for large surveys such as DES and the Large Synoptic Survey Telescope. The capability of creating science-ready catalogs efficiently and with full control of the inputs and configurations used is an important asset for supporting science analysis using data from large astronomical surveys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison Between Infrared Optical and Stereoscopic X-Ray Technologies for Patient Setup in Image Guided Stereotactic Radiotherapy

Purpose: To compare infrared (IR) optical vs. stereoscopic X-ray technologies for patient setup in image-guided stereotactic radiotherapy. Methods and Materials: Retrospective data analysis of 233 fractions in 127 patients treated with hypofractionated stereotactic radiotherapy was performed. Patient setup at the linear accelerator was carried out by means of combined IR optical localization and stereoscopic X-ray image fusion in 6 degrees of freedom (6D). Data were analyzed to evaluate the geometric and dosimetric discrepancy between the two patient setup strategies. Results: Differences between IR optical localization and 6D X-ray image fusion parameters were on average within the expected localization accuracy, as limited by CT image resolution (3 mm). A disagreement between the two systems below 1 mm in all directions was measured in patients treated for cranial tumors. In extracranial sites, larger discrepancies and higher variability were observed as a function of the initial patient alignment. The compensation of IR-detected rotational errors resulted in a significantly improved agreement with 6D X-ray image fusion. On the basis of the bony anatomy registrations, the measured differences were found not to be sensitive to patient breathing. The related dosimetric analysis showed that IR-based patient setup caused limited variations in three cases, with 7% maximum dose reduction in the clinical target volume and no dose increase in organs at risk. Conclusions: In conclusion, patient setup driven by IR external surrogates localization in 6D featured comparable accuracy with respect to procedures based on stereoscopic X-ray imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systematic Review of Radiation Therapy Toxicity Reporting in Randomized Controlled Trials of Rectal Cancer: A Comparison of Patient-Reported Outcomes and Clinician Toxicity Reporting

The use of multimodal treatments for rectal cancer has improved cancer-related outcomes but makes monitoring toxicity challenging. Optimizing future radiation therapy regimens requires collection and publication of detailed toxicity data. This review evaluated the quality of toxicity information provided in randomized controlled trials (RCTs) of radiation therapy in rectal cancer and focused on the difference between clinician-reported and patient-reported toxicity. Medline, EMBASE, and the Cochrane Library were searched (January 1995-July 2013) for RCTs reporting late toxicity in patients treated with regimens including preoperative (chemo)radiation therapy. Data on toxicity measures and information on toxicity reported were extracted using Quantitative Analyses of Normal Tissue Effects in the Clinic recommendations. International Society for Quality of Life Research standards on patient-reported outcomes (PROs) were used to evaluate the quality of patient-reported toxicity. Twenty-one RCT publications met inclusion criteria out of 4144 articles screened. All PRO studies reported higher rates of toxicity symptoms than clinician-reported studies and reported on a wider range and milder symptoms. No clinician-reported study published data on sexual dysfunction. Of the clinician-reported studies, 55% grouped toxicity data related to an organ system together (eg “Bowel”), and 45% presented data only on more-severe (grade ≥3) toxicity. In comparison, all toxicity grades were reported in 79% of PRO publications, and all studies (100%) presented individual symptom toxicity data (eg bowel urgency). However, PRO reporting quality was variable. Only 43% of PRO studies presented baseline data, 28% did not use any psychometrically validated instruments, and only 29% of studies described statistical methods for managing missing data. Analysis of these trials highlights the lack of reporting standards for adverse events and reveals the differences between clinician and patient reporting of toxicity. Recommendations for improving the quality of adverse event data collection are provided, with the aim of improving critical appraisal of outcomes for future studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Greenhouse gases accounting and reporting for waste management - A South African perspective

This paper investigates how greenhouse gases are accounted and reported in the waste sector in South Africa. Developing countries (including South Africa) do not have binding emission reduction targets, but many of them publish different greenhouse gas emissions data which have been accounted and reported in different ways. Results show that for South Africa, inventories at national and municipal level are the most important tools in the process of accounting and reporting greenhouse gases from waste. For the development of these inventories international initiatives were important catalysts at national and municipal levels, and assisted in developing local expertise, resulting in increased output quality. However, discrepancies in the methodology used to account greenhouse gases from waste between inventories still remain a concern. This is a challenging issue for developing countries, especially African ones, since higher accuracy methods are more data intensive. Analysis of the South African inventories shows that results from the recent inventories can not be compared with older ones due to the use of different accounting methodologies. More recently the use of Clean Development Mechanism (CDM) procedures in Africa, geared towards direct measurements of greenhouse gases from landfill sites, has increased and resulted in an improvement of the quality of greenhouse gas inventories at municipal level.

54 ENVIRONMENTAL SCIENCES↗

Effects of Improved 17 O Correction on Interlaboratory Agreement in Clumped Isotope Calibrations, Estimates of Mineral-Specific Offsets, and Temperature Dependence of Acid Digestion Fractionation

The clumped isotopic composition of carbonate-CO 2 (denoted Δ 47 ) is a function of carbonate formation temperature and in natural samples can act as a recorder of paleoclimate, burial, or diagenetic conditions. The absolute abundance of heavy isotopes in the universal standards VPDB and VSMOW (defined by four parameters: R 13 VPDB , R 17 VSMOW , R 18 VSMOW , and λ ) impact calculated Δ 47 values. In this work, we investigate whether use of updated and more accurate values for these parameters can remove observed interlaboratory differences in the measured T-Δ 47 relationship. Using the updated parameters, we reprocess 14 published calibration data sets measured in 11 different laboratories, representing many mineralogies, bulk compositions, sample types, reaction temperatures, and sample preparation and analysis methods. Exploiting this large composite data set ( n = 1,253 sample replicates), we investigate the possibility for a “universal” clumped isotope calibration. We find that applying updated parameters improves the T-Δ 47 relationship (reduces residuals) within most labs and improves overall agreement but does not eliminate all interlaboratory differences. We reaffirm earlier findings that different mineralogies do not require different calibration equations and that cleaning procedures, method of pressure baseline correction, and mass spectrometer type do not affect interlaboratory agreement. We also present new estimates of the temperature dependence of the acid digestion fractionation for Δ 47 (Δ* 25-X ), based on combining reprocessed data from four studies, and new theoretical equilibrium values to be used in calculation of the empirical transfer function. Overall, we have ruled out a number of possible causes of interlaboratory disagreement in the T-Δ 47 relationship, but many more remain to be investigated.

58 GEOSCIENCES↗

Plunger lifetime measurements after Coulomb excitation at intermediate beam energies

Absolute transition probabilities of the first 2{sup +} state in {sup 110,114}Pd were remeasured using the recoil distance Doppler shift technique following projectile Coulomb excitation at intermediate beam energies for the first time. The {sup 110}Pd experiment served to check the novel technique as well as the method used for the data analysis which is based on the examination of {gamma}-ray lineshapes. Whereas the measured B(E2) value for {sup 110}Pd agrees very well with the literature, the value obtained for {sup 114}Pd differs considerably. The data is also used to test a novel concept, called the valence proton symmetry, which allows one to extrapolate nuclear properties to very neutron rich nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microstrain in tetragonal lead-zirconate-titanate: The effect of pressure on the ionic displacements

Piezoelectric materials respond to external stimuli by adjusting atomic positions. In solid-solutions, the changes occurring in atomic scale are very complex since the short- and long-range order are different. Standard methods used in diffraction data analysis fail to model the short-range order accurately. Pressure-induced cation displacements in ferroelectric Pb(Zr{sub 0.45}Ti{sub 0.55})O{sub 3} perovskite oxide are modeled by starting from a short-range order. We show that the model gives the average structure correctly and properly describes the local structure. The origin of the microstrain in lead zirconate titanate is the spatially varying Zr and Ti concentration and atomic distances, which is taken into account in the simulation. High-pressure neutron powder diffraction and simulation techniques are applied for the determination of atomic positions and bond-valences as a function of pressure. Under hydrostatic pressure, the material loses its piezoelectric properties far before the transition to the cubic phase takes place. The total cation valence +6 is preserved up to 3.31 GPa by compensating the increasing B-cation valence by decreasing Pb-displacement from the high-symmetry position. At 3.31 GPa, Pb-displacement is zero and the material is no more ferroelectric. This is also the pressure at which the Pb-valence is minimized. The average structure is still tetragonal. The model for microstrain predicts that the transition occurs over a finite pressure range: Pb-displacements are spatially varying and follow the distribution of Zr and Ti ions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design, installation, commissioning and operation of a beamlet monitor in the negative ion beam test stand at NIFS

In the framework of the accompanying activity for the development of the two neutral beam injectors for the ITER fusion experiment, an instrumented beam calorimeter is being designed at Consorzio RFX, to be used in the SPIDER test facility (particle energy 100keV; beam current 50A), with the aim of testing beam characteristics and to verify the source proper operation. The main components of the instrumented calorimeter are one-directional carbon-fibre-carbon composite tiles. Some prototype tiles have been used as a small-scale version of the entire calorimeter in the test stand of the neutral beam injectors of the LHD experiment, with the aim of characterising the beam features in various operating conditions. The extraction system of the NIFS test stand source was modified, by applying a mask to the first gridded electrode, in order to isolate only a subset of the beamlets, arranged in two 3×5 matrices, resembling the beamlet groups of the ITER beam sources. The present contribution gives a description of the design of the diagnostic system, including the numerical simulations of the expected thermal pattern. Moreover the dedicated thermocouple measurement system is presented. The beamlet monitor was successfully used for a full experimental campaign, during which the main parameters of the source, mainly the arc power and the grid voltages, were varied. This contribution describes the methods of fitting and data analysis applied to the infrared images of the camera to recover the beamlet optics characteristics, in order to quantify the response of the system to different operational conditions. Some results concerning the beamlet features are presented as a function of the source parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conformational sampling enhancement of replica exchange molecular dynamics simulations using swarm particle intelligence

In this paper, we present a new method based on swarm particle social intelligence for use in replica exchange molecular dynamics simulations. In this method, the replicas (representing the different system configurations) are allowed communicating with each other through the individual and social knowledge, in additional to considering them as a collection of real particles interacting through the Newtonian forces. The new method is based on the modification of the equations of motion in such way that the replicas are driven towards the global energy minimum. The method was tested for the Lennard-Jones clusters of N = 4, 5, and 6 atoms. Our results showed that the new method is more efficient than the conventional replica exchange method under the same practical conditions. In particular, the new method performed better on optimizing the distribution of the replicas among the thermostats with time and, in addition, ergodic convergence is observed to be faster. We also introduce a weighted histogram analysis method allowing analyzing the data from simulations by combining data from all of the replicas and rigorously removing the inserted bias.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raman effect, structural and dielectric properties of sol-gel synthesized polycrystalline GaFe{sub 1-x}Zr{sub x}O{sub 3} (0≤x≤0.15)

Polycrystalline ceramic samples of Zirconium (Zr)-doped GaFeO{sub 3} (GaFe{sub 1-x}Zr{sub x}O{sub 3}) were studied using powder X-ray diffraction, complex impedance spectroscopy and Raman spectroscopic measurements to understand the effect of Zr doping on the structural and dielectric properties. The samples with varying Zr content were prepared by Sol-Gel method. X-ray data analysis confirmed the formation of single phase material without formation of any secondary phases and all are crystallized in Pc2{sub 1}n orthorhombic symmetry. Rietveld refinement of the X-ray data suggested an increase in the lattice constants due to size effect and decreases on x = 0.15 due to the effect of change in interplanner spacing. Impedance studies on the samples showed that the dielectric constant increases while loss tangent decrease as the Zr content increases. Raman scattering on GaFe{sub 1-x}Zr{sub x}O{sub 3} (x = 0, 0.05, 0.10, & 0.15) used to understand the composition dependence on phonon modes at room temperature. On Zr doping, Raman modes frequencies shifts to lower energies consistent with the X-ray data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison of implosion core metrics: A 10 ps dilation X-ray imager vs a 100 ps gated microchannel plate [Comparison of implosion core shape observations, 10 ps dilation X-ray imager vs 100 ps gated microchannel plate]

The dilation x-ray imager (DIXI) is a high-speed x-ray framing camera that uses the pulse-dilation technique to achieve a temporal resolution of less than 10 ps. This is a 10× improvement over conventional framing cameras currently employed on the National Ignition Facility (NIF) (100 ps resolution), and otherwise only achievable with 1D streaked imaging. A side effect of the dramatically reduced gate width is the comparatively lower detected signal level. Therefore we implement a Poisson noise reduction with non-local principal component analysis method to improve the robustness of the DIXI data analysis. Furthermore, we present results on ignition-relevant experiments at the NIF using DIXI. In particular we focus on establishing that/when DIXI gives reliable shape metrics (P 0 , P 2 and P 4 Legendre modes, and their temporal evolution/swings).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reconstruction of 2D line-integrated electron density using angular filter refractometry and a fast marching Eikonal solver

Refraction of an optical probe beam by a plasma can be measured with angular filter refractometry (AFR), which produces an image of the beam’s 2D spatial profile that contains intensity contours corresponding to curves of constant refraction angle. Further analysis is required to reconstruct the underlying line-integrated electron density. Most prior efforts to calculate density from AFR data have been limited to 1D analysis or forward-fitting techniques. Here, in this paper, we detail the use of a fast-marching Eikonal solver to directly invert AFR data and obtain the full 2D line-integrated electron density. The analysis method is first verified with synthetic data and then applied to experimental measurements of single and colliding plasma plumes collected at the OMEGA EP Laser Facility. The calculated densities agree with 1D results and are shown to be consistent with the original AFR measurements via forward modeling. We also discuss ways to improve the precision of this technique.

McCluskey, B. [Princeton Univ., NJ (United States)↗

AN OBSERVATIONAL DETERMINATION OF THE PROTON TO ELECTRON MASS RATIO IN THE EARLY UNIVERSE

In an effort to resolve the discrepancy between two measurements of the fundamental constant mu, the proton to electron mass ratio, at early times in the universe we reanalyze the same data used in the earlier studies. Our analysis of the molecular hydrogen absorption lines in archival Very Large Telescope/Ultraviolet and Visible Echelle Spectrometer (UVES) spectra of the damped Lyman alpha systems in the quasi-stellar objects Q0347-383 and Q0405-443 yields a combined measurement of a DELTAmu/mu value of (-7 +- 8) x 10{sup -6}, consistent with no change in the value of mu over a time span of 11.5 Gyr. Here, we define DELTAmu as (mu {sub z} - mu{sub 0}) where mu {sub z} is the value of mu at a redshift of z and mu{sub 0} is the present-day value. Our null result is consistent with the recent measurements of King et al., DELTAmu/mu = (2.6 +- 3.0) x 10{sup -6}, and inconsistent with the positive detection of a change in mu by Reinhold et al. Both of the previous studies and this study are based on the same data but with differing analysis methods. Improvements in the wavelength calibration over the UVES pipeline calibration is a key element in both of the null results. This leads to the conclusion that the fundamental constant mu is unchanged to an accuracy of 10{sup -5} over the last 80% of the age of the universe, well into the matter dominated epoch. This limit provides constraints on models of dark energy that invoke rolling scalar fields and also limits the parameter space of supersymmetric or string theory models of physics. New instruments, both planned and under construction, will provide opportunities to greatly improve the accuracy of these measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Decoding the shift-invariant data: applications for band-excitation scanning probe microscopy *

A shift-invariant variational autoencoder (shift-VAE) is developed as an unsupervised method for the analysis of spectral data in the presence of shifts along the parameter axis, disentangling the physically-relevant shifts from other latent variables. Using synthetic data sets, we show that the shift-VAE latent variables closely match the ground truth parameters. The shift VAE is extended towards the analysis of band-excitation piezoresponse force microscopy data, disentangling the resonance frequency shifts from the peak shape parameters in a model-free unsupervised manner. The extensions of this approach towards denoising of data and model-free dimensionality reduction in imaging and spectroscopic data are further demonstrated. This approach is universal and can also be extended to analysis of x-ray diffraction, photoluminescence, Raman spectra, and other data sets.

36 MATERIALS SCIENCE↗

Uncertainty-quantified phenomenological optical potentials for single-nucleon scattering

Optical-model potentials (OMPs) continue to play a key role in nuclear reaction calculations. However, the uncertainty of phenomenological OMPs in widespread use—inherent to any parametric model trained on data—has not been fully characterized, and its impact on downstream users of OMPs remains unclear. Here we assign well-calibrated uncertainties for two representative global OMPs, those of Koning-Delaroche and Chapel Hill '89, using Markov-chain Monte Carlo for parameter inference. By comparing the canonical versions of these OMPs against the experimental data originally used to constrain them, we show how a lack of outlier rejection and a systematic underestimation of experimental uncertainties contributes to bias of, and overconfidence in, best-fit parameter values. Our updated, uncertainty-quantified versions of these OMPs address these issues and yield complete covariance information for potential parameters. Scattering predictions generated from our ensembles show improved performance both against the original training corpora of experimental data and against a new “test” corpus comprising many of the experimental single-nucleon scattering data collected over the last twenty years. Finally, we apply our uncertainty-quantified OMPs to two case studies of application-relevant cross sections. We conclude that, for many common applications of OMPs, including OMP uncertainty should become standard practice. Furthermore, to facilitate their immediate use, digital versions of our updated OMPs and related tools for forward uncertainty propagation are included as Supplemental Material.

150 ≤ A ≤ 189↗

Search for the decay B s 0 → π 0 π 0 at Belle

We report the results of the first search for the decay B$^{0}_{s}$ → π 0 ⁢π 0 using 121.4 fb -1 of data collected at the Y⁡(5⁢S) resonance with the Belle detector at the KEKB asymmetric-energy e + ⁢e - collider. We observe no signal and set a 90% confidence level upper limit of 7.7 ×10 -6 on the B$^{0}_{s}$ → π 0 π 0 decay branching fraction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗