Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Temperature gradients for thermophysical and thermochemical property measurements to 3000 °C for an aerodynamically levitated spheroid

This study examines thermal gradients in ceramic oxide spheroids being aerodynamically levitated in a conical nozzle levitator (CNL) system equipped with a CO 2 laser (10.6 μm wavelength). The CNL system is a versatile piece of equipment that can easily be coupled with advanced thermophysical and thermochemical measuring devices, such as diffraction/scattering (X-ray and neutron), nuclear magnetic resonance, and calorimetry, for the analysis of bulk spheroidal solids and liquids. The thermal gradients of a series of single crystal, polycrystalline solids, and liquid spheroids have been measured spatially in the CNL system, by means of a disappearing filament pyrometer (800-3000 °C) and by X-ray diffraction with reference to an internal standard (Pt: 800-1600 °C). The thermal gradient in a levitated sample being heated by a laser from the top can be minimized by: (i) maximizing the sphericity, (ii) maximizing the density, and (iii) minimizing microstructural features. A spheroid with these properties can be manufactured via machining a perfect sphere from a highly dense, chemically and phase pure pellet. These properties promote rotation of the sample about multiple axes in the air stream, enabling homogeneous heating. This homogeneous heating is the dominant factor in reducing thermal gradients in solid state samples. It was found that the thermal gradient in an similar to 3 mm diameter solid sample could be reduced from 1000 °C to 30 °C, by having a perfectly spherical shape that could rotate on multiple axes in a high velocity gas stream (similar to 1500-2000 cm 3 /min). As a result, these findings will allow accurate thermophysical and thermochemical property measurements of solids in situ at high temperatures, using the CNL system.

47 OTHER INSTRUMENTATION↗

Ion Transport Dynamics at Nanoscale Interfaces in Single Asymmetric Nanopores and Nanopore Arrays (Final Scientific and Technological Report)

The grant (DE-SC0019043) from the Department of Energy’s Office of Basic Energy Sciences has an overarching goal of establishing mechanistic understanding on the emerging time-dependent ion transport behaviors at nanometer scale interfaces in single nanopores and nanopore arrays with broken symmetry. The fundamental research aims to ultimately advance applications such as ion separation and desalination, or water purification; and energy harvesting, or power generation from salinity gradients. Water desalination refers to the process that removes excess salt or electrolyte ions from water to obtain fresh water. This process consumes energy and is important considering the increasing demand for fresh water, energy cost, concerns on environmental impacts, and needs in resource-limited conditions. The reverse process of desalination, for example where sea/brackish water and river/fresh water meet, can serve as unconventional sources to extract energy, sometimes referred as blue energy harvesting. A critical bottleneck in those and other relevant applications is the tradeoff in selectivity and throughput of ion transport, in other words the ability to discriminate and control the transport of ions against solvent water and/or among different ions. Fundamental insights and new design principles are needed to improve the efficacy and efficiency of the materials and devices for those applications. The green chemistry approaches in addressing energy and environmental challenges have been instrumental in inspiring the students at Georgia State University, an urban R-1 minority-serving institution that is both a predominantly black and hispanic serving institution, through PI’s research and teaching endeavors amid the significant impacts by the pandemic during the grant period.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Center for Integrated Simulation of Fusion Relevant RF Actuators

This project was part of the “Center for Integrated Simulation of Fusion Relevant RF Actuators” SciDAC-4 project, led by Dr. Paul Bonoli (MIT). Rather than use an acronym (CISFRRFA), the project will be referred to in this document as the “RF-SciDAC4”. The larger SciDAC-4 project goals were to: 1. Develop an integrated simulation of the antenna + sheath + scrape-off-layer + core plasma system which fully utilizes leadership class computing resources to move towards a quantitative predictive capability for the response to RF power. 2. Work closely with the SciDAC-4 Whole Device Modeling (WDM) community to make both our new code development efforts, as well as the established hierarchy of RF tools, available within their environment, and to utilize WDM technologies to implement the couplings below. 3. Validate this predictive capability on appropriately diagnosed experiments including dedicated RF test stands, linear devices, and existing tokamaks. 4. Use these tools to inform design of robust, impurity-mitigating RF heating and current drive sources for future fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Speed and Hysteresis-Free Near-Infrared Optical Hydrogen Sensor Based on Ti/Pd Bilayer Thin Films

Palladium (Pd) and titanium (Ti) exhibit opposite dielectric responses upon hydrogenation, with stronger effects observed in the near-infrared (NIR) region. Leveraging this contrast, we investigated Ti/Pd bilayer thin films as a platform for NIR hydrogen sensing—particularly at telecommunication-relevant wavelengths, where such devices have remained largely unexplored. Ti/Pd bilayers coated with Teflon AF (TAF) and fabricated via sequential electron-beam and thermal evaporation were characterized using optical transmission measurements under repeated hydrogenation cycles. The Ti (5 nm)/Pd (x = 2.5 nm)/TAF (30 nm) architecture showed a 2.7-fold enhancement in the hydrogen-induced optical contrast at 1550 nm compared to Pd/TAF reference films, attributed to the hydrogen ion exchange between the Ti and Pd layers. The optimized structure, with a Pd thickness of x = 1.9 nm, exhibited hysteresis-free sensing behavior, a rapid response time (t90 < 0.35 s at 4% H2), and a detection limit below 10 ppm. It also demonstrated excellent selectivity with negligible cross-sensitivity to CO2, CH4, and CO, as well as high durability, showing less than 6% signal degradation over 135 hydrogenation cycles. These findings establish a scalable, room-temperature NIR hydrogen sensing platform with strong potential for deployment in automotive, environmental, and industrial applications.

Chemistry↗

Flight effects on fan noise with static and wind tunnel comparisons

A flight test program utilizing a JT15D-1 turbofan engine has been conducted with the objectives of studying flight effects on fan noise and evaluating the simulation effectiveness of both a wind tunnel and a static test configuration that incorporated an inlet control device (ICD). In conjunction with synchronized laser-radar tracking and meteorological profile information, data obtained from a linear array of ground microphones was narrowband-analyzed and ensemble-averaged to yield highly accurate far-field flight acoustic results. Utilizing appropriate corrections, flight, wind tunnel, and static acoustic data were normalized to a static-equivalent, 100-foot radius, lossless reference condition. Data comparisons showed that both the static test with ICD and wind tunnel were generally very effective in simulating flight blade-passage-frequency (BPF) noise levels. However, differences were observed in broadband noise levels and in the details of the multiple-pure-tone harmonics.

Preisser, J. S.↗

Incompressible viscous flow computations for the pump components and the artificial heart

A finite-difference, three-dimensional incompressible Navier-Stokes formulation to calculate the flow through turbopump components is utilized. The solution method is based on the pseudocompressibility approach and uses an implicit-upwind differencing scheme together with the Gauss-Seidel line relaxation method. Both steady and unsteady flow calculations can be performed using the current algorithm. In this work, the equations are solved in steadily rotating reference frames by using the steady-state formulation in order to simulate the flow through a turbopump inducer. Eddy viscosity is computed by using an algebraic mixing-length turbulence model. Numerical results are compared with experimental measurements and a good agreement is found between the two. Included in the appendix is a paper on incompressible viscous flow through artificial heart devices with moving boundaries. Time-accurate calculations, such as impeller and diffusor interaction, will be reported in future work.

Kiris, Cetin↗

Evaluation of Coronary Artery Disease and Coronary Anomalies with a Handheld Smartphone

The purpose of this study was to determine the diagnostic accuracy of an iPhone for evaluation of the coronary arteries on coronary CT angiography (CTA) in comparison to a standard clinical workstation. Fifty coronary CTA exams were selected to include a range of normal and abnormal cases including both coronary artery disease (CAD) of varying severity and coronary artery anomalies. Two cardiac radiologists reviewed each exam on a standard clinical workstation initially and then on an iPhone 6 after a washout period. Coronary stenosis was evaluated on a 4-point scale and presence of coronary anomalies was recorded. Two additional cardiac radiologists reviewed all cases in consensus on the standard workstation and these results were used as the reference standard. When reader results were compared to the reference standard, there was no significant difference in agreement for per-vessel stenosis scores using either the iPhone or standard clinical workstation. The intraobserver intertechnology agreement on a per-vessel basis for obstructive CAD were 97.4% (299/307, kappa = 0.777) and 97.5% (317/325, kappa = 0.804) for the two readers. All cases of coronary anomalies were identified by both readers regardless of the device used. Coronary CTA examinations can be interpreted on a smartphone with diagnostic accuracy comparable to a standard workstation. 3D visualization app on the iPhone may facilitate urgent coronary CTA review when a workstation is not available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid prediction of fuel research octane number and octane sensitivity using the AFIDA constant-volume combustion chamber

Current research octane number (RON) and motor octane number (MON) gasoline performance characterization techniques use dated, complex engine testing methodology and limit researchers’ ability to easily characterize small volumes of experimental fuels. A novel methodology is presented that correlates measured ignition delay (ID) time to RON in an Advanced Fuel Ignition Delay Analyzer (AFIDA) constant-volume combustion chamber device at a single pressure/temperature condition, with an r2 of 0.99 and standard error (SE) of 1.0. The correlation of the slope of the ID time between two additional temperature points to octane sensitivity (S) produces an r2 of 0.97 and SE of 0.69; however, fuels with S>12 are indistinguishable. These results are based on methodology calibration using 31 primary and toluene reference fuels containing 0%-40% ethanol with RON values ranging from 85 to 113. Validation of these methods using a 102-sample fuel matrix spanning an array of base fuels and additive chemistry designed to test the robust applicability of the method, along with pump gasoline and high-octane surrogate blend samples, demonstrates an r2 of 0.94 and SE of 1.3 for the RON correlation over all samples, whereas the equivalent S correlation produces an r2 of 0.78 and SE of 1.2 by excluding two additives, 3-pentanone and diisobutylene, which displayed poor S correlation results. This novel AFIDA analysis method can be performed in 1 h and with 40 mL of fuel, offering significant improvements in time and volume requirements over traditional techniques.

33 ADVANCED PROPULSION SYSTEMS↗

An airborne study of microwave surface sensing and boundary layer heat and moisture fluxes for Project FIFE

This is the third semiannual status report describing the University of Wyoming participation in project FIFE, under NASA Grant NAG 5-913. The reader is referred to the first and second semiannual status reports for this grant for descriptions of University of Wyoming participation in the field operations of 1987. This report is concerned with continuing analysis of field data. Most of the instrument calibration effort has concentrated on interpretation and use of the high-rate water vapor measurements with the University of Wyoming Lyman-alpha device. In addition, fluxes of water vapor have been corrected for sensible heat flux, and all the high-rate (10 Hz for the Wyoming King Air) data have been filtered before the flux calculations. For each flight the Lyman-alpha data (10 Hz) are calibrated against the Cambridge dew-point hygrometer (1 Hz), by using data from the take-off sounding. The reasoning here is that the takeoff sounding (held to 500 fpm rate-of-climb specifically for the calibration) covers the widest range of humidity conditions of any sequence of the flight. For each takeoff sounding, then, the Lyman-alpha data, averaged to 1 Hz, are matched to the dewpoint data with a second-order least-squares fit. The resulting quadratic equation is then used in all subsequent analyses to convert the Lyman-alpha voltages to vapor desities for that specific flight. An alternative method is to use the range of fluctuation for the same two devices from horizontal passes to establish the calibration function. However, since the Lyman-alpha data are used only in the flux calculations, i.e., only the fluctuation and not the absolute values are used, this method is thought unnecessary.

Kelly, Robert D.↗

Ka-Band, MEMS Switched Line Phase Shifters Implemented in Finite Ground Coplanar Waveguide

Ka-band MEMS switched line phase shifters implemented in finite ground coplanar waveguide are described in this paper. The phase shifters are constructed of single-pole double-throw (SPDT) switches with additional reference and phase offset transmission line lengths. The one- and two-bit phase shifters are fabricated on high resistivity (HR) silicon with a dielectric constant, Epsilon(sub T) = 11.7 and a substrate thickness, t = 500microns. The switching architectures integrated within the phase shifters consist of MEMS switches that are doubly anchored cantilever beam capacitive switches with additional high inductive sections (MEMS LC device). The SPDT switch is composed of a T-junction with a MEMS LC device at each output port. The one-bit phase shifter described in this paper has an insertion loss (IL) and return loss (RL) of 0.9 dB and 30 dB while the two-bit described has an IL and RL of 1.8 dB and 30 dB respectively. The one-bit phase shifter's designed offset phase is 22.5deg and actual measured phase shift is 21.8deg. The two-bit phase shifter's designed offset phase is 22.5deg, 45deg, and 67.5deg and the actual measured phase shifts are 21.4deg, 44.2deg, and 65.8deg, respectively.

Scardelletti, Maximilian C.↗

Total dose bias dependency and ELDRS effects in bipolar linear devices

Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited Enhanced Low Dose Rate Sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrate results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.

ELDRS voltage regulator voltage reference↗

A Process for Producing Highly Wettable Aluminum 6061 Surfaces Compatible with Hydrazine

NASA's Global Precipitation Measurement (GPM) mission is an ongoing Goddard Space Flight Center (GSFC) project whose basic objective is to improve global precipitation measurements. The space-based portion of the mission architecture consists of a primary or core spacecraft and a constellation of NASA and contributed spacecrafts. The efforts described in this paper refer to the core spacecraft (hereafter referred to as simply GPM) which is to be fabricated at GSFC. It has been decided that the GPM spacecraft is to be a "design-for-demise-spacecraft." This requirement resulted in the need for a propellant tank that would also demise or ablate to an appropriate degree upon re-entry. Composite overwrapped aluminum lined propellant tanks with aluminum propellant management devices (PMD) were shown by analyses to demise and thus became the baseline configuration for GPM. As part of the GPM tank development effort, long term compatibility and wettability testing with hydrazine was performed on Al6061 and 2219 coupons fabricated and cleaned by conventional processes. Long term compatibility was confirmed. However, the wettability of the aluminum as measured by contact angle produced higher than desired angles (greater than 30 deg.) with excessive scatter. The availability of PMD materials exhibiting consistently low contact angles aids in the design of simple PMDs. Two efforts performed by Angeles Crest Engineering and funded by GSFC were undertaken to reduce the risk of using aluminum for the GPM PMD. The goal of the first effort was to develop a cleaning or treatment process to produce consistently low contact angles. The goal of the second effort was to prove via testing that the processed aluminum would retain compatibility with hydrazine and retain low contact angle after long term exposure to hydrazine. Both goals were achieved. This paper describes both efforts and the results achieved.

Moore, N. R.↗

Spacecraft Material Characterization Using Reflectance Spectra Extracted from RGB/IR Color Images

The space environment is detrimental to the exterior of the spacecraft and imposes stringent requirements on spacecraft materials. Space materials are often expected to perform for 15-20 years in the harsh space environment without significant degradation of their optical, electrical, mechanical and thermal properties. Further, as commercial activities increase in the space domain, development of predictive capability for material evolution is critical for agile adaption of novel materials. Therefore, it is very important to understand the effects of the space environments on the spacecraft materials. The Materials on the International Space Station Experiment Flight Facility (MISSE-FF) has flown numerous material samples to investigate the effect of LEO space weather exposure on the performance and durability of materials and devices. We are manifest on the MISSE-16 mission, scheduled to launch in June 2022, to fly fifteen novel and well-characterized materials in the LEO environment for a duration of six months. Changes in spectral reflectivity will be measured in real time throughout the mission with an RGB/IR camera. These time-resolved data will function as a "space-truth" reference for our team's ongoing laboratory-based space weather-material interaction experiments. Correlation of the MISSE-16 data with extensive ground testing of duplicate samples under simulated space weather conditions will enable development of fundamental chemical models for material degradation. This paper discusses preliminary results from the ground test campaign to collect the RGB/IR images for pristine and damaged materials and the development of machine learning algorithms to extract reflectance spectra from the color images.

Jainisha R. Shah↗

Spacecraft Material Characterization Using Reflectance Spectra Extracted from RGB/IR Color Images

The space environment is detrimental to the exterior of the spacecraft and imposes stringent requirements on spacecraft materials. Space materials are often expected to perform for 15-20 years in the harsh space environment without significant degradation of their optical, electrical, mechanical and thermal properties. Further, as commercial activities increase in the space domain, development of predictive capability for material evolution is critical for agile adaption of novel materials. Therefore, it is very important to understand the effects of the space environments on the spacecraft materials. The Materials on the International Space Station Experiment Flight Facility (MISSE-FF) has flown numerous material samples to investigate the effect of LEO space weather exposure on the performance and durability of materials and devices. We are manifest on the MISSE-16 mission, scheduled to launch in June 2022, to fly fifteen novel and well-characterized materials in the LEO environment for a duration of six months. Changes in spectral reflectivity will be measured in real time throughout the mission with an RGB/IR camera. These time-resolved data will function as a "space-truth" reference for our team's ongoing laboratory-based space weather-material interaction experiments. Correlation of the MISSE-16 data with extensive ground testing of duplicate samples under simulated space weather conditions will enable development of fundamental chemical models for material degradation. This paper discusses preliminary results from the ground test campaign to collect the RGB/IR images for pristine and damaged materials and the development of machine learning algorithms to extract reflectance spectra from the color images.

Jainisha R. Shah↗

A Vacuum-Compatible, Spectrally Tunable, Flat Panel Uniform Source for Testing Large Aperture Earth Observation Systems

Labsphere, Inc. in conjunction with NASA GSFC and Genesis Engineering Solutions Inc., has developed an innovative, vacuum compatible, calibration spectro-radiometric illumination source with a highly uniform large-area rectangular flat panel active area. This device features a uniquely shaped diffuse integration geometry to achieve high uniformity over a large active output area while maintaining a smaller and more robust overall form-factor when compared to previous designs or integrating spheres. A new liquid-cooled hybrid quartz-tungsten (QT) and light emitting diode (LED) source module has been engineered to provide direct-in-vacuum reference illumination over the full dynamic range and spectrum of the VIIRS instrument’s optical bands during pre-launch testing. The first unit has been demonstrated to meet its requirements using ambient technology and a fully-vacuum-compatible second unit is planned to allow testing in thermal vacuum (TVAC) campaigns. This technology is flexible and capable of meeting the needs of many other instruments/missions requiring this type of test/calibration capability.

Jeffrey Holt↗

tite

The TITE library provides type erasure implementation utilizing the tag_invoke paradigm proposed for standardization here: https://open-std.org/JTC1/SC22/WG21/docs/papers/2019/p1895r0.pdf. The implementation contained herein is largely modeled after that provided in the standardization proposal and available at https://godbolt.org/z/3TvO4f. Significant modification have been made to the original implementation to improve its suitability to be utilized for GPU architectures. In particular the implementation: - only requires a C++14 standard. - has been extended to obtain vtables for GPU device architectures in addition to CPU host architectures. - provides a gpu_allocator class appropriate for allocation of the type-erased object to GPU memory - provides copy semantics omitted from the original implementation-- - generally the copy semantics are to completely copy the type-erased object - when the usage of the type-erased object guarantees immutability the copy semantics are altered to reference-counted shallow copies (copies of pointers) for improved performance

Solomon, CJ↗

Insights into Engine Knock: Comparisons of Knock Metrics across Ranges of Intake Temperature and Pressure in the CFR Engine

Of late there has been a resurgence in studies investigating parameters that quantify combustion knock in both standardized platforms and modern spark-ignition engines. However, it is still unclear how metrics such as knock (octane) rating, knock onset, and knock intensity are related and how fuels behave according to these metrics across a range of conditions. As part of an ongoing study, the air supply system of a standard Cooperative Fuel Research (CFR) F1/F2 engine was modified to allow mild levels of intake air boosting while staying true to its intended purpose of being the standard device for American Society for Testing and Materials (ASTM)-specified knock rating or octane number tests. For instance, the carburation system and intake air heating manifold are not altered, but the engine was equipped with cylinder pressure transducers to enable both logging of the standard knockmeter readout and state-of-the-art indicated data. For this study, the engine was operated using primary reference fuel 90 (PRF90) at 600 rpm, first following the procedures of the ASTM D2699 research octane number test protocol in order to define the geometric compression ratio set point for standard knock number. Thereafter, compression ratio sweeps were conducted at intake temperatures ranging from 30 to 150°C and intake air boost extending from 0 to 0.3 bar above ambient. The resulting operating map provided a broad envelope of compressed in-cylinder conditions relevant to modern spark-ignition engines. Detailed analysis of the indicated data highlighted a poor correlation between established knock intensity metrics and the knockmeter reading, which is used to characterize a fuel’s octane number. It was further found that the auto-ignition characteristics of PRF90 could be perturbed by means of intake air boosting and heating without being captured by the knockmeter reading.

Rockstroh, Toby↗

Eddy-Current Inspection Of Tab Seals On Beverage Cans

Eddy-current inspection system monitors tab seals on beverage cans. Device inspects all cans at usual production rate of 1,500 to 2,000 cans per minute. Automated inspection of all units replaces visual inspection by microscope aided by mass spectrometry. System detects defects in real time. Sealed cans on conveyor pass near one of two coils in differential eddy-current probe. Other coil in differential eddy-current probe positioned near stationary reference can on which tab seal is known to be of acceptable quality. Signal of certain magnitude at output of probe indicates defective can, automatically ejected from conveyor.

Bar-Cohen, Yoseph↗