Search NASA⌕ Search

SEARCH · Search NASA

Results for “script”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

SU-G-IeP1-08: MR Geometric Distortion Dependency On Imaging Sequence, Acquisition Orientation and Receiver Bandwidth of a Dedicated 1.5T MR-Simulator

Purpose: To investigate the 3D geometric distortion of four potential MR sequences for radiotheraptic applications, and its dependency on sequence-type, acquisition-orientation and receiver-bandwidth from a dedicated 1.5T 700mm-wide bore MR-simulator (Magnetom-Aera, Sienmens Healthcare, Erlangen, Germany), using a large customized geometric accuracy phantom. Methods: This work studied 3D gradient-echo (VIBE) and spin-echo (SPACE) sequences for anatomical imaging; a specific ultra-short-TE sequence (PETRA) potentially for bone imaging and MR-based dosimetry; and a motion-insensitive sequence (BLADE) for dynamic applications like 4D-MRI. Integrated geometric-correction was employed, three orthogonal acquisition-orientations and up to three receiver-bandwidths were used, yielding 27 acquisitions for testing (Table 1a).A customized geometric accuracy phantom (polyurethane, MR/CT invisible, W×L×H:55×55×32.5cm3) was constructed and filled with 3892 spherical markers (6mm diameter, MR/CT visible) arranged on a 25mm-interval 3D isotropic-grid (Fig.1). The marker positions in MR images were quantitatively calculated and compared against those in the CT-reference using customized MatLab scripts. Results: The average distortion within various diameter-of-spherical-volumes (DSVs) and the usable DSVs under various distortion limits were measured (Tables 1b-c). It was observed that distortions fluctuated when sequence-type, acquisition-orientation or receiver-bandwidth changed (e.g. within 300mm-DSV, the lowest/highest average distortions of VIBE were 0.40mm/0.59mm, a 47.5% difference). According to AAPM-TG66 (<1mm distortion, left-most column of Table 1c), PETRA (Largest-DSV:253.9mm) has the potential on brain treatment, while BLADE (Largest-DSV:207.2mm) may need improvement for thoracic/abdominal applications. The results of VIBE (Largest-DSVs:294.3mm, the best among tested acquisitions) and SPACE (Largest-DSVs:267.7mm) suggests their potentials on head and neck applications. These Largest-DSVs were attained on different acquisition-orientations and receiver-bandwidths. Conclusion: Geometric distortion was shown to be dependent on sequence-type, acquisition-orientation and receiver-bandwidth. In the experiment, no configuration in any one of these factors could consistently reduce distortion while the others were varying. The distortion analysis result is a valuable guideline for sequence selection and optimization for MR-aided radiotherapy applications.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-09: Fast Dose-Averaged LET and Biological Dose Calculations for Proton Therapy Using Graphics Cards

Purpose: To demonstrate fast and accurate Monte Carlo (MC) calculations of proton dose-averaged linear energy transfer (LETd) and biological dose (BD) on a Graphics Processing Unit (GPU) card. Methods: A previously validated GPU-based MC simulation of proton transport was used to rapidly generate LETd distributions for proton treatment plans. Since this MC handles proton-nuclei interactions on an event-by-event using a Bertini intranuclear cascade-evaporation model, secondary protons were taken into account. The smaller contributions of secondary neutrons and recoil nuclei were ignored. Recent work has shown that LETd values are sensitive to the scoring method. The GPU-based LETd calculations were verified by comparing with a TOPAS custom scorer that uses tabulated stopping powers, following recommendations by other authors. Comparisons were made for prostate and head-and-neck patients. A python script is used to convert the MC-generated LETd distributions to BD using a variety of published linear quadratic models, and to export the BD in DICOM format for subsequent evaluation. Results: Very good agreement is obtained between TOPAS and our GPU MC. Given a complex head-and-neck plan with 1 mm voxel spacing, the physical dose, LETd and BD calculations for 10{sup 8} proton histories can be completed in ∼5 minutes using a NVIDIA Titan X card. The rapid turnover means that MC feedback can be obtained on dosimetric plan accuracy as well as BD hotspot locations, particularly in regards to their proximity to critical structures. In our institution the GPU MC-generated dose, LETd and BD maps are used to assess plan quality for all patients undergoing treatment. Conclusion: Fast and accurate MC-based LETd calculations can be performed on the GPU. The resulting BD maps provide valuable feedback during treatment plan review. Partially funded by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-12: Optimized Parallel MonteCarlo Dose Calculations for Secondary MU Checks

Purpose: Secondary MU checks are an important tool used during a physics review of a treatment plan. Commercial software packages offer varying degrees of theoretical dose calculation accuracy, depending on the modality involved. Dose calculations of VMAT plans are especially prone to error due to the large approximations involved. Monte Carlo (MC) methods are not commonly used due to their long run times. We investigated two methods to increase the computational efficiency of MC dose simulations with the BEAMnrc code. Distributed computing resources, along with optimized code compilation, will allow for accurate and efficient VMAT dose calculations. Methods: The BEAMnrc package was installed on a high performance computing cluster accessible to our clinic. MATLAB and PYTHON scripts were developed to convert a clinical VMAT DICOM plan into BEAMnrc input files. The BEAMnrc installation was optimized by running the VMAT simulations through profiling tools which indicated the behavior of the constituent routines in the code, e.g. the bremsstrahlung splitting routine, and the specified random number generator. This information aided in determining the most efficient compiling parallel configuration for the specific CPU’s available on our cluster, resulting in the fastest VMAT simulation times. Our method was evaluated with calculations involving 10{sup 8} – 10{sup 9} particle histories which are sufficient to verify patient dose using VMAT. Results: Parallelization allowed the calculation of patient dose on the order of 10 – 15 hours with 100 parallel jobs. Due to the compiler optimization process, further speed increases of 23% were achieved when compared with the open-source compiler BEAMnrc packages. Conclusion: Analysis of the BEAMnrc code allowed us to optimize the compiler configuration for VMAT dose calculations. In future work, the optimized MC code, in conjunction with the parallel processing capabilities of BEAMnrc, will be applied to provide accurate and efficient secondary MU checks.

60 APPLIED LIFE SCIENCES↗

TU-H-BRC-03: Evaluation of Very High-Energy Electron (VHEE) Beams in Comparison to VMAT and PBS Treatment Plans

Purpose: The aim of this study was to evaluate the performance of very high-energy electron (VHEE) beams in comparison to clinically delivered treatment plans generated with volumetric modulated arc therapy (VMAT) and proton pencil beam scanning (PBS) technology. Methods: Three clinical cases were selected (prostate, lung, and pediatric CNS). The VHEE plans were calculated in the Monte Carlo EGSnrc code and pencil beam doses were calculated using the DOSxyznrc MC code for 100 and 200 MeV beams. Treatment plans with VHEE, VMAT, and PBS were optimized in a research version of RayStation using an in house build script in order to minimize operator bias between the different techniques. Results: For the prostate cancer case, the PBS plan showed lower mean organ at risk (OAR) doses compared to the other modalities. An exception was the femoral heads, due to the lateral beam arrangements. The VMAT plan showed lower mean doses to the rectum and the bladder compared to the 100 MeV VHEE plan. The lung cancer case showed minor differences between the three modalities. However, the PBS plan showed a lower contralateral lung dose. The pediatric CNS case showed a better conformity and lower spinal cord dose for the 100 MeV VHEE plan. For all cases, the 200 MeV VHEE plans were found to be similar to or better than the 100 MeV VHEE plans. Conclusion: The present study showed that VHEE plans are similar or superior to VMAT plans with reduced mean OAR dose and increased target conformity for a variety of clinical cases. With increased VHEE energy, better conformity and even higher reductions in mean OAR doses can be achieved. Funding: DoD, Award#:W81XWH-13-1-0165, Weston Havens Foundation, Bio-X (Stanford University), the Office of the Dean of the Medical School, the Office of the Provost (Stanford University), and the Swedish Childhood Cancer Foundation. BL and PM are founders of TibaRay,Inc. BL and PM have received research grants from Varian and RaySearch Laboratory.

60 APPLIED LIFE SCIENCES↗

TH-AB-207A-05: A Fully-Automated Pipeline for Generating CT Images Across a Range of Doses and Reconstruction Methods

Purpose: To evaluate the robustness of CAD or Quantitative Imaging methods, they should be tested on a variety of cases and under a variety of image acquisition and reconstruction conditions that represent the heterogeneity encountered in clinical practice. The purpose of this work was to develop a fully-automated pipeline for generating CT images that represent a wide range of dose and reconstruction conditions. Methods: The pipeline consists of three main modules: reduced-dose simulation, image reconstruction, and quantitative analysis. The first two modules of the pipeline can be operated in a completely automated fashion, using configuration files and running the modules in a batch queue. The input to the pipeline is raw projection CT data; this data is used to simulate different levels of dose reduction using a previously-published algorithm. Filtered-backprojection reconstructions are then performed using FreeCT-wFBP, a freely-available reconstruction software for helical CT. We also added support for an in-house, model-based iterative reconstruction algorithm using iterative coordinate-descent optimization, which may be run in tandem with the more conventional recon methods. The reduced-dose simulations and image reconstructions are controlled automatically by a single script, and they can be run in parallel on our research cluster. The pipeline was tested on phantom and lung screening datasets from a clinical scanner (Definition AS, Siemens Healthcare). Results: The images generated from our test datasets appeared to represent a realistic range of acquisition and reconstruction conditions that we would expect to find clinically. The time to generate images was approximately 30 minutes per dose/reconstruction combination on a hybrid CPU/GPU architecture. Conclusion: The automated research pipeline promises to be a useful tool for either training or evaluating performance of quantitative imaging software such as classifiers and CAD algorithms across the range of acquisition and reconstruction parameters present in the clinical environment. Funding support: NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRB-02: Feasibility of Optimization for Dynamic Trajectory Radiotherapy

Purpose: Over the last years, volumetric modulated arc therapy (VMAT) has been widely introduced into clinical routine using a coplanar delivery technique. However, VMAT might be improved by including dynamic couch and collimator rotations, leading to dynamic trajectory radiotherapy (DTRT). In this work the feasibility and the potential benefit of DTRT was investigated. Methods: A general framework for the optimization was developed using the Eclipse Scripting Research Application Programming Interface (ESRAPI). Based on contoured target and organs at risk (OARs), the structures are extracted using the ESRAPI. Sampling potential beam directions, regularly distributed on a sphere using a Fibanocci-lattice, the fractional volume-overlap of each OAR and the target is determined and used to establish dynamic gantry-couch movements. Then, for each gantry-couch track the most suitable collimator angle is determined for each control point by optimizing the area between the MLC leaves and the target contour. The resulting dynamic trajectories are used as input to perform the optimization using a research version of the VMAT optimization algorithm and the ESRAPI. The feasibility of this procedure was tested for a clinically motivated head and neck case. Resulting dose distributions for the VMAT plan and for the dynamic trajectory treatment plan were compared based on DVH-parameters. Results: While the DVH for the target is virtually preserved, improvements in maximum dose for the DTRT plan were achieved for all OARs except for the inner-ear, where maximum dose remains the same. The major improvements in maximum dose were 6.5% of the prescribed dose (66 Gy) for the parotid and 5.5% for the myelon and the eye. Conclusion: The result of this work suggests that DTRT has a great potential to reduce dose to OARs with similar target coverage when compared to conventional VMAT treatment plans. This work was supported by Varian Medical Systems. This work was supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRB-06: Implementation of a Modulated-Arc Total Body Irradiation (TBI) Technique Using the RayStation Treatment Planning System

Purpose: To develop a clinical workflow for delivering a modulated-arc total body irradiation (TBI) with RayStation scripting. This technique uses arc fields with the patient lying at floor level on a padded table and is validated through measurements taken on a custom-made TBI phantom. Methods: Treatment planning was performed for a retrospective cohort of eight patients with a diverse range of heights and body types. Each was replanned using an open-field dual arc method, with the patient in supine and prone positions on the floor of the vault. All plans were optimized using Raystation Planning 4.7.2.5 (RaySearch Laboratories, Stockholm, Sweden), with 200 cGy prescribed to the 95% of the body contour − 5mm. This results in an open-field beam that sweeps craniocaudally across the length of the patient. The technique is validated with measurements at 10 cm intervals in a custom-milled, 5 cm thick acrylic phantom. A centrally located CC13 ion chamber and a Mobile MOSFET (Best Medical Canada, Ottawa, ON) detector array were used to measure dose. Supine and prone arcs for each patient were consecutively delivered, and the aggregate dose at each point was compared to the planned dose calculated in the phantom. Results: The ion chamber measurements differed from the planned dose by an average of .5%, with a standard deviation of 2.1%. All measured data for the MOSFETS were within 10% of the corresponding planned dose except for two outlying points. The standard deviation of dose differences across the entire cohort was 4.0%. Most significant discrepancies occurred either in inhomogeneous regions with large gradients, or at inferior points where beam angle was steepest. Conclusion: We have confirmed that the planned dose is well matched to our measurements within 10% for this method of planning and delivery. We are currently incorporating this technique into our clinical workflow. This work is supported by RaySearch.

60 APPLIED LIFE SCIENCES↗

Sci-Fri AM: Quality, Safety, and Professional Issues 05: QC Program Management and the Benefits of QATrack+

Purpose: Treatment unit uptime statistics are typically used to monitor radiation equipment performance. The Ottawa Hospital Cancer Centre has introduced the use of Quality Control (QC) test success as a quality indicator for equipment performance and overall health of the equipment QC program. Methods: Implemented in 2012, QATrack+ is used to record and monitor over 1100 routine machine QC tests each month for 20 treatment and imaging units ( http://qatrackplus.com/ ). Using an SQL (structured query language) script, automated queries of the QATrack+ database are used to generate program metrics such as the number of QC tests executed and the percentage of tests passing, at tolerance or at action. These metrics are compared against machine uptime statistics already reported within the program. Results: Program metrics for 2015 show good correlation between pass rate of QC tests and uptime for a given machine. For the nine conventional linacs, the QC test success rate was consistently greater than 97%. The corresponding uptimes for these units are better than 98%. Machines that consistently show higher failure or tolerance rates in the QC tests have lower uptimes. This points to either poor machine performance requiring corrective action or to problems with the QC program. Conclusions: QATrack+ significantly improves the organization of QC data but can also aid in overall equipment management. Complimenting machine uptime statistics with QC test metrics provides a more complete picture of overall machine performance and can be used to identify areas of improvement in the machine service and QC programs.

60 APPLIED LIFE SCIENCES↗

The narrative arc: Revealing core narrative structures through text analysis

Scholars across disciplines have long debated the existence of a common structure that underlies narratives. Using computer-based language analysis methods, several structural and psychological categories of language were measured across ~40,000 traditional narratives (e.g., novels and movie scripts) and ~20,000 nontraditional narratives (science reporting in newspaper articles, TED talks, and Supreme Court opinions). Across traditional narratives, a consistent underlying story structure emerged that revealed three primary processes: staging, plot progression, and cognitive tension. No evidence emerged to indicate that adherence to normative story structures was related to the popularity of the story. Last, analysis of fact-driven texts revealed structures that differed from story-based narratives.

60 APPLIED LIFE SCIENCES↗

Diazotroph Community Characterization via a High-Throughput nifH Amplicon Sequencing and Analysis Pipeline

The dinitrogenase reductase gene ( nifH ) is the most widely established molecular marker for the study of nitrogen-fixing prokaryotes in nature. A large number of PCR primer sets have been developed for nifH amplification, and the effective deployment of these approaches should be guided by a rapid, easy-to-use analysis protocol. Bioinformatic analysis of marker gene sequences also requires considerable expertise. In this study, we advance the state of the art for nifH analysis by evaluating nifH primer set performance, developing an improved amplicon sequencing workflow, and implementing a user-friendly bioinformatics pipeline. Furthermore, the developed amplicon sequencing workflow is a three-stage PCR-based approach that uses established technologies for incorporating sample-specific barcode sequences and sequencing adapters. Based on our primer evaluation, we recommend the Ando primer set be used with a modified annealing temperature of 58°C, as this approach captured the largest diversity of nifH templates, including paralog cluster IV/V sequences. To improve nifH sequence analysis, we developed a computational pipeline which infers taxonomy and optionally filters out paralog sequences. In addition, we employed an empirical model to derive optimal operational taxonomic unit (OTU) cutoffs for the nifH gene at the species, genus, and family levels. A comprehensive workflow script named TaxADivA (TAXonomy Assignment and DIVersity Assessment) is provided to ease processing and analysis of nifH amplicons. Our approach is then validated through characterization of diazotroph communities across environmental gradients in beach sands impacted by the Deepwater Horizon oil spill in the Gulf of Mexico, in a peat moss-dominated wetland, and in various plant compartments of a sugarcane field. IMPORTANCE: Nitrogen availability often limits ecosystem productivity, and nitrogen fixation, exclusive to prokaryotes, comprises a major source of nitrogen input that sustains food webs. The nifH gene, which codes for the iron protein of the nitrogenase enzyme, is the most widely established molecular marker for the study of nitrogen-fixing microorganisms (diazotrophs) in nature. In this study, a flexible sequencing/analysis pipeline, named TaxADivA, was developed for nifH amplicons produced by Illumina paired-end sequencing, and it enables an inference of taxonomy, performs clustering, and produces output in formats that may be used by programs that facilitate data exploration and analysis. Diazotroph diversity and community composition are linked to ecosystem functioning, and our results advance the phylogenetic characterization of diazotroph communities by providing empirically derived nifH similarity cutoffs for species, genus, and family levels. Thus, the utility of our pipeline is validated for diazotroph communities in a variety of ecosystems, including contaminated beach sands, peatland ecosystems, living plant tissues, and rhizosphere soil.

59 BASIC BIOLOGICAL SCIENCES↗

MaDaTS: Managing Data on Tiered Storage for Scientific Workflows

Scientific workflows are increasingly used in High Performance Computing (HPC) environments to manage complex simulation and analyses, often consuming and generating large amounts of data. However, workflow tools have limited support for managing the input, output and intermediate data. The data elements of a workflow are often managed by the user through scripts or other ad-hoc mechanisms. Technology advances for future HPC systems is redefining the memory and storage subsystem by introducing additional tiers to improve the I/O performance of data-intensive applications. These architectural changes introduce additional complexities to managing data for scientific workflows. Thus, we need to manage the scientific workflow data across the tiered storage system on HPC machines. In this paper, we present the design and implementation of MaDaTS (Managing Data on Tiered Storage for Scientific Workflows), a software architecture that manages data for scientific workflows. We introduce Virtual Data Space (VDS), an abstraction of the data in a workflow that hides the complexities of the underlying storage system while allowing users to control data management strategies. We evaluate the data management strategies with real scientific and synthetic workflows, and demonstrate the capabilities of MaDaTS. Our experiments demonstrate the flexibility, performance and scalability gains of MaDaTS as compared to the traditional approach of managing data in scientific workflows.

Ghoshal, Devarshi↗

WiP Abstract: Edge-Based Privacy of Naturalistic Driving Data Collection

Collecting large driving datasets is important for data-driven transportation research and studied in naturalistic driving [3]. Due to the standard implementation of a Controller Area Network (CAN) bus for a vehicle’s inter-module communication, many off-the-shelf devices can easily transform a vehicle into a rich data collection utility [2]. Vehicles with Adaptive Cruise Control (ACC) are an example of a feature resulting in emergent traffic behavior when scaled [4]. While these utilities were designed with particular data use cases, data may be publicly shared to benefit other researchers through online tools like CyVerse [1]. However, such data should only be shared when any private information is removed. This private information may exist as a set of GPS coordinates, since the start and end points of a trip may designate a driver’s place of residence or work. When considering larger continuously-collected data sets with a focus on naturalistic driving, many drivers are needed to make data collection feasible. Removal of private information becomes much more of a challenge since every driver may uniquely define their geographic privacy. This project aims to build upon the foundation of libpanda [2] by adding features of edge-based data privacy enforcement. In it’s current form, libpanda uses a GPS in conjunction with a CAN interface to record data. Libpanda feature s a set of startup and shutdown scripts to perform automatic data collection and upload. With additional support hardware on a Raspberry Pi, the Pi can maintain power on vehicle shutdown to automatically upload data before shutdown.

Bunting, Matt↗

Approaches for Synthesis and Deployment of Controller Models on Automated Vehicles for Car-following in Mixed Autonomy

This paper describes the software design patterns and vehicle interfaces that were employed to transition vehicle controllers from simulation environments to open-road field experiments. The approach relies on a life cycle that utilizes model-based design and code generation, along with agile software development, and both software and hardware-in-the-loop testing, with additional safety margins. Autonomous designs should consider the dynamics of mixed autonomy in traffic to safely operate among humans. The software that provides a vehicle’s behavior intelligence is often developed through simulation, which may have a mismatch between dynamics, or as a result of a reinforcement learning workflow, which may be a black box with challenges to analyze. In each of these cases, it is important to have research interfaces that provide strongly typed data streams accessible to researchers who are not software experts while continuing to satisfy safety and liveness constraints. This paper describes how we design the hardware platform interfaces and software design process for a mixed autonomy traffic experiment with a leader-follower scenario. Controller synthesis for these vehicles requires clearly articulated vehicle interfaces and software design patterns for successful onboard deployment. Testing strategies for such controllers are also described before algorithms are transitioned to full-scale field experiments with safety operators for the vehicles. Testing strategies include software-in-the-loop simulation testing, hardware-in-the-loop simulation, ghost-car testing, and read-only testing in live traffic. With our approach, we were not only able to validate our controller synthesized in scripts and simulation, but also able to scale deployment to multiple vehicles.

Bhadani, Rahul↗

HPC Campaign Management: Remote data access with user-defined error bound using ADIOS and ZFP

Remote access to large-scale scientific datasets, like those generated by combustion simulations or other high-performance computing (HPC) applications, presents a significant challenge. Downloading entire datasets is often impractical due to their size and the bandwidth limitations of typical networks. To address this challenge, we propose a novel approach that enables efficient remote access to large datasets distributed across multiple facilities. Our method enables technologies to download only the data values of a select variable, in a select region of interest, to a user-defined accuracy. For this purpose, we extended the ADIOS IO library to provide read functions with user-defined accuracy, a remote data server that understands multidimensional selections of specific variables, steps and accuracy from an ADIOS dataset, and which uses lossy compression on the remote site to reduce the data to be transferred back to the client. In addition, our extension of the ADIOS library collects metadata from multiple datasets in small files called Campaign Archives, which can be shared among project participants on any HPC, cloud or laptop, and which can easily facilitate the discovery of content and pointers to the data location as well as remote access to the data by local tools as if data was local. This feature called Campaign Management, enables a group of scientists to manage related datasets stored in multiple files, across multiple facilities as if it was in a single file/database. We demonstrate the effectiveness of our approach using a 1.5 TB dataset from the S3D combustion simulation on Frontier at the Oak Ridge Leadership Facility. Even a single variable from this dataset, at 64 GB, is too large to be processed on a standard laptop. We show two different reading patterns for 2D plots and 3D visualization, with careful settings that a scientist studying combustion data would do and show that running the same Python scripts on Frontier directly takes comparable time than running them on the local laptop with remote access to the data on Frontier.

Podhorszki, Norbert [ORNL] (ORCID:000000019647542X↗

A Right Transfer Access Control Model of Internet of Things Based on Smart Contract

Sensor nodes play a crucial role in the promotion of development of Internet of Things (IoT). Through this transaction, RO defines access control policies in script form based on ABAC's access control model to grant access right. The identity of all users in the model is identified by address. This paper builds a more flexible right transfer access control model by means of combining the Attribute-Based Access Control model (ABAC) and blockchain technology. Owing to the characteristics of ABAC’s attributes and right association, the massive problems of some sensor nodes can be solved. At the same time, for the sake of addressing the dynamic problems such as node access and right transfer, right transfer contract (TS) and access control contract (CS) are employed on the chain to ensure efficient and safe transmission of rights. To solve on-chain storage problems and ensure transparency of the operation, the idea of Rollup in Ethereum expansion is used to upload the final state of protocol policy and right exchange to the chain. Any user can know the policy and current right transfer status at any time. Finally, comparative and security analysis show that the model presented here can solve IoT devices’ massive and dynamic problems more effectively and it is more secure than the traditional models.

Wang, Jiuru↗