Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity Loss”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

SINGLE-SHELL TANKS LEAK INTEGRITY ELEMENTS/SX FARM LEAK CAUSES AND LOCATIONS - 12127

Washington River Protection Solutions, LLC (WRPS) developed an enhanced single-shell tank (SST) integrity project in 2009. An expert panel on SST integrity was created to provide recommendations supporting the development of the project. One primary recommendation was to expand the leak assessment reports (substitute report or LD-1) to include leak causes and locations. The recommendation has been included in the M-045-9IF Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) as one of four targets relating to SST leak integrity. The 241-SX Farm (SX Farm) tanks with leak losses were addressed on an individual tank basis as part of LD-1. Currently, 8 out of 23 SSTs that have been reported to having a liner leak are located in SX Farm. This percentage was the highest compared to other tank farms which is why SX Farm was analyzed first. The SX Farm is comprised of fifteen SSTs built 1953-1954. The tanks are arranged in rows of three tanks each, forming a cascade. Each of the SX Farm tanks has a nominal I-million-gal storage capacity. Of the fifteen tanks in SX Farm, an assessment reported leak losses for the following tanks: 241-SX-107, 241-SX-108, 241-SX-109, 241-SX-111, 241-SX-112, 241-SX-113, 241-SX-114 and 241-SX-115. The method used to identify leak location consisted of reviewing in-tank and ex-tank leak detection information. This provided the basic data identifying where and when the first leaks were detected. In-tank leak detection consisted of liquid level measurement that can be augmented with photographs which can provide an indication of the vertical leak location on the sidewall. Ex-tank leak detection for the leaking tanks consisted of soil radiation data from laterals and drywells near the tank. The in-tank and ex-tank leak detection can provide an indication of the possible leak location radially around and under the tank. Potential leak causes were determined using in-tank and ex-tank information that is not directly related to leak detection. In-tank parameters can include temperature of the supernatant and sludge, types of waste, and chemical determination by either transfer or sample analysis. Ex-tank information can be assembled from many sources including design media, construction conditions, technical specifications, and other sources. Five conditions may have contributed to SX Farm tank liner failure including: tank design, thermal shock, chemistry-corrosion, liner behavior (bulging), and construction temperature. Tank design did not apparently change from tank to tank for the SX Farm tanks; however, there could be many unknown variables present in the quality of materials and quality of construction. Several significant SX Farm tank design changes occurred from previous successful tank farm designs. Tank construction occurred in winter under cold conditions which could have affected the ductile to brittle transition temperature of the tanks. The SX Farm tanks received high temperature boiling waste from REDOX which challenged the tank design with rapid heat up and high temperatures. All eight of the leaking SX Farm tanks had relatively high rate of temperature rise. Supernatant removal with subsequent nitrate leaching was conducted in all but three of the eight leaking tanks prior to leaks being detected. It is possible that no one characteristic of the SX Farm tanks could in isolation from the others have resulted in failure. However, the application of so many stressors - heat up rate, high temperature, loss of corrosion protection, and tank design - working jointly or serially resulted in their failure. Thermal shock coupled with the tank design, construction conditions, and nitrate leaching seem to be the overriding factors that can lead to tank liner failure. The distinction between leaking and sound SX Farm tanks seems to center on the waste types, thermal conditions, and nitrate leaching.

54 ENVIRONMENTAL SCIENCES↗

Assessment of a novel ternary eutectic chloride salt for next generation high-temperature sensible heat storage

A novel ternary eutectic salt mixture for high-temperature sensible heat storage, composed of sodium chloride, potassium chloride and magnesium chloride (NaKMg-Cl) was developed based on a phase diagram generated with FactSage(R). The differential scanning calorimetry (DSC) technique was used to experimentally validate the predicted melting point of the ternary eutectic composition, which was measured as 387 degrees C, in good agreement with the prediction. The ternary eutectic was compared to two binary salts formulated based on prediction of the eutectic composition by FactSage, but unfortunately DSC measurements showed that neither binary salt composition was eutectic. Nonetheless, the measured thermo-physical properties of the ternary and the two binary mixtures are compared. Liquid heat capacities of both the ternary and binary salts were determined by using DSC with sapphire as the standard reference. The average heat capacity of the ternary mixture was recorded as 1.18 J g -1 K -1 . The mass loss of the molten eutectic salts was studied up to 1000 degrees C using a thermogravimetric analyser in nitrogen, argon and air. The results showed a significant mass loss due to vaporisation in an open system, particularly above 700 degrees C. However, simulation of mass loss in a closed system with an inert cover gas indicates storage temperatures above 700 degrees C may be feasible, and highlights the importance of the design of the storage tank system. In terms of storage material cost, the NaKMg-Cl mixture is approximately 4.5 USD/kWh, which is 60% cheaper than current state-of-the-art nitrate salt mixtures.

14 SOLAR ENERGY↗

Surrogate Modeling for Capacity Planning of Charging Station Equipped With Photovoltaic Panel and Hydropneumatic Energy Storage

Due to the promising potential for environmental sustainability, there has been a significant increase of electric vehicles (EVs) and plug-in hybrid electric vehicles (PHEV) in the market. To support this increasing demand for EVs and PHEVs, challenges related to capacity planning and investment costs of public charging infrastructure must be addressed. Hence, in this paper, a capacity planning problem for charging stations is developed and aims to balance the current capital investment costs and future operational revenue. The charging station is assumed to be equipped with the solar photovoltaic (PV) panel and an energy storage system, which could be electric battery or recently invented hydropneumatic energy storage (ground-level integrated diverse energy storage (GLIDES)) system. A co-optimization model that minimizes investment and operation cost is established to determine optimal solution while considering capacity planning and following operations. EV mobility is modeled as an Erlang-loss system. Meanwhile, stochastic programming is adopted to capture uncertainties from solar radiation and charging demand of EV fleet. To provide a more general and computationally efficient model, main configuration parameters are sampled in design space and then fixed in solving the co-optimization model. Sampled parameters include EV charging slots number, PV area, capacity of energy storage system, and daily mean EV arrival number. Based on the sampled parameter combinations and its responses, black-box mappings are then constructed using surrogate models, which could provide insights for charging station placement in different practical situations. The effectiveness of the proposed surrogate modeling approach is demonstrated in numerical experiments. Here, the results indicate better profit advantage of GLIDES over battery system with the increased power capacity

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Single-Shell Tanks Leak Integrity Elements/ SX Farm Leak Causes and Locations - 12127

Washington River Protection Solutions, LLC (WRPS) developed an enhanced single-shell tank (SST) integrity project in 2009. An expert panel on SST integrity was created to provide recommendations supporting the development of the project. One primary recommendation was to expand the leak assessment reports (substitute report or LD-1) to include leak causes and locations. The recommendation has been included in the M-045-91F Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) as one of four targets relating to SST leak integrity. The 241-SX Farm (SX Farm) tanks with leak losses were addressed on an individual tank basis as part of LD-1. Currently, 8 out of 23 SSTs that have been reported to having a liner leak are located in SX Farm. This percentage was the highest compared to other tank farms which is why SX Farm was analyzed first. The SX Farm is comprised of fifteen SSTs built 1953-1954. The tanks are arranged in rows of three tanks each, forming a cascade. Each of the SX Farm tanks has a nominal 1-million-gal storage capacity. Of the fifteen tanks in SX Farm, an assessment reported leak losses for the following tanks: 241-SX-107, 241-SX-108, 241-SX-109, 241-SX- 111, 241-SX-112, 241-SX-113, 241-SX-114 and 241-SX-115. The method used to identify leak location consisted of reviewing in-tank and ex-tank leak detection information. This provided the basic data identifying where and when the first leaks were detected. In-tank leak detection consisted of liquid level measurement that can be augmented with photographs which can provide an indication of the vertical leak location on the sidewall. Ex-tank leak detection for the leaking tanks consisted of soil radiation data from laterals and dry-wells near the tank. The in-tank and ex-tank leak detection can provide an indication of the possible leak location radially around and under the tank. Potential leak causes were determined using in-tank and ex-tank information that is not directly related to leak detection. In-tank parameters can include temperature of the supernatant and sludge, types of waste, and chemical determination by either transfer or sample analysis. Ex-tank information can be assembled from many sources including design media, construction conditions, technical specifications, and other sources. Five conditions may have contributed to SX Farm tank liner failure including: tank design, thermal shock, chemistry-corrosion, liner behavior (bulging), and construction temperature. Tank design did not apparently change from tank to tank for the SX Farm tanks; however, there could be many unknown variables present in the quality of materials and quality of construction. Several significant SX Farm tank design changes occurred from previous successful tank farm designs. Tank construction occurred in winter under cold conditions which could have affected the ductile to brittle transition temperature of the tanks. The SX Farm tanks received high temperature boiling waste from REDOX which challenged the tank design with rapid heat up and high temperatures. All eight of the leaking SX Farm tanks had relatively high rate of temperature rise. Supernatant removal with subsequent nitrate leaching was conducted in all but three of the eight leaking tanks prior to leaks being detected. It is possible that no one characteristic of the SX Farm tanks could in isolation from the others have resulted in failure. However, the application of so many stressors - heat up rate, high temperature, loss of corrosion protection, and tank design working jointly or serially resulted in their failure. Thermal shock coupled with the tank design, construction conditions, and nitrate leaching seem to be the overriding factors that can lead to tank liner failure. The distinction between leaking and sound SX Farm tanks seems to center on the waste types, thermal conditions, and nitrate leaching. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transcription Factor 4 loss-of-function is associated with deficits in progenitor proliferation and cortical neuron content

Transcription Factor 4 ( TCF4) has been associated with autism, schizophrenia, and other neuropsychiatric disorders. However, how pathological TCF4 mutations affect the human neural tissue is poorly understood. Here, we derive neural progenitor cells, neurons, and brain organoids from skin fibroblasts obtained from children with Pitt-Hopkins Syndrome carrying clinically relevant mutations in TCF4 . We show that neural progenitors bearing these mutations have reduced proliferation and impaired capacity to differentiate into neurons. We identify a mechanism through which TCF4 loss-of-function leads to decreased Wnt signaling and then to diminished expression of SOX genes, culminating in reduced progenitor proliferation in vitro. Moreover, we show reduced cortical neuron content and impaired electrical activity in the patient-derived organoids, phenotypes that were rescued after correction of TCF4 expression or by pharmacological modulation of Wnt signaling. This work delineates pathological mechanisms in neural cells harboring TCF4 mutations and provides a potential target for therapeutic strategies for genetic disorders associated with this gene.

59 BASIC BIOLOGICAL SCIENCES↗

Thermochemical and kinetic aspects of the sulfurization of Cu-Sb and Cu-Bi thin films

CuSbS{sub 2} and Cu{sub 3}BiS{sub 3} are being investigated as part of a search for new absorber materials for photovoltaic devices. Thin films of these chalcogenides were produced by conversion of stacked and co-electroplated metal precursor layers in the presence of elemental sulfur vapour. Ex-situ XRD and SEM/EDS analyses of the processed samples were employed to study the reaction sequence with the aim of achieving compact layer morphologies. A new 'Time-Temperature-Reaction' (TTR) diagram and modified Pilling-Bedworth coefficients have been introduced for the description and interpretation of the reaction kinetics. For equal processing times, the minimum temperature required for CuSbS{sub 2} to appear is substantially lower than for Cu{sub 3}BiS{sub 3}, suggesting that interdiffusion across the interfaces between the binary sulfides is a key step in the formation of the ternary compounds. The effects of the heating rate and sulfur partial pressure on the phase evolution as well as the potential losses of Sb and Bi during the processes have been investigated experimentally and the results related to the equilibrium pressure diagrams obtained via thermochemical computation. - Graphical Abstract: Example of 3D plot showing the equilibrium pressure surfaces of species potentially escaping from chalcogenide films as a function of temperature and sulfur partial pressure. Bi{sub (g)}, Bi{sub 2(g)}, and BiS{sub (g)} are the gaseous species in equilibrium with solid Bi{sub 2}S{sub 3(s)} considered in this specific example. The pressure threshold plane corresponds to the pressure limit above which the elemental losses from 1 {mu}m thick films exceeds 10% of the original content per cm{sup 2} area of film and dm{sup 3} capacity of sulfurization furnace under static atmosphere conditions. The sulfurization temperature/sulfur partial pressure boundaries required to minimise the elemental losses below a given value can be easily read from the 2D projection of the intersection curves into the T-p{sub S2} plane. Highlights: Black-Right-Pointing-Triangle Sulfurization of Sb-Cu and Bi-Cu metal precursors for thin film PV applications. Black-Right-Pointing-Triangle Kinetics shows the rate determining step to be the interdiffusion of binary sulfides. Black-Right-Pointing-Triangle Phase evolution is consistent with Pilling-Bedworth coefficients of Cu, Sb and Bi. Black-Right-Pointing-Triangle Elemental losses can be minimised via the use of equilibrium pressure diagrams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final Technical Report Recovery Act: Online Nonintrusive Condition Monitoring and Fault Detection for Wind Turbines

The penetration of wind power has increased greatly over the last decade in the United States and across the world. The U.S. wind power industry installed 1,118 MW of new capacity in the first quarter of 2011 alone and entered the second quarter with another 5,600 MW under construction. By 2030, wind energy is expected to provide 20% of the U.S. electricity needs. As the number of wind turbines continues to grow, the need for effective condition monitoring and fault detection (CMFD) systems becomes increasingly important [3]. Online CMFD is an effective means of not only improving the reliability, capacity factor, and lifetime, but it also reduces the downtime, energy loss, and operation and maintenance (O&M) of wind turbines. The goal of this project is to develop novel online nonintrusive CMFD technologies for wind turbines. The proposed technologies use only the current measurements that have been used by the control and protection system of a wind turbine generator (WTG); no additional sensors or data acquisition devices are needed. Current signals are reliable and easily accessible from the ground without intruding on the wind turbine generators (WTGs) that are situated on high towers and installed in remote areas. Therefore, current-based CMFD techniques have great economic benefits and the potential to be adopted by the wind energy industry. Specifically, the following objectives and results have been achieved in this project: (1) Analyzed the effects of faults in a WTG on the generator currents of the WTG operating at variable rotating speed conditions from the perspective of amplitude and frequency modulations of the current measurements; (2) Developed effective amplitude and frequency demodulation methods for appropriate signal conditioning of the current measurements to improve the accuracy and reliability of wind turbine CMFD; (3) Developed a 1P-invariant power spectrum density (PSD) method for effective signature extraction of wind turbine faults with characteristic frequencies in the current or current demodulated signals, where 1P stands for the shaft rotating frequency of a WTG; (4) Developed a wavelet filter for effective signature extraction of wind turbine faults without characteristic frequencies in the current or current demodulated signals; (5) Developed an effective adaptive noise cancellation method as an alternative to the wavelet filter method for signature extraction of wind turbine faults without characteristic frequencies in the current or current demodulated signals; (6) Developed a statistical analysis-based impulse detection method for effective fault signature extraction and evaluation of WTGs based on the 1P-invariant PSD of the current or current demodulated signals; (7) Validated the proposed current-based wind turbine CMFD technologies through extensive computer simulations and experiments for small direct-drive WTGs without gearboxes; and (8) Showed, through extensive experiments for small direct-drive WTGs, that the performance of the proposed current-based wind turbine CMFD technologies is comparable to traditional vibration-based methods. The proposed technologies have been successfully applied for detection of major failures in blades, shafts, bearings, and generators of small direct-drive WTGs. The proposed technologies can be easily integrated into existing wind turbine control, protection, and monitoring systems and can be implemented remotely from the wind turbines being monitored. The proposed technologies provide an alternative to vibration-sensor-based CMFD. This will reduce the cost and hardware complexity of wind turbine CMFD systems. The proposed technologies can also be combined with vibration-sensor-based methods to improve the accuracy and reliability of wind turbine CMFD systems. When there are problems with sensors, the proposed technologies will ensure proper CMFD for the wind turbines, including their sensing systems. In conclusion, the proposed technologies offer an effective means to achieve condition-based smart maintenance for wind turbines and have a great potential to be adopted by the wind energy industry due to their almost no-cost, nonintrusive features. Although only validated for small direct-drive wind turbines without gearboxes, the proposed technologies are also applicable for CMFD of large-size wind turbines with and without gearboxes. However, additional investigations are recommended in order to apply the proposed technologies to those large-size wind turbines.

17 WIND ENERGY↗

Climate warming causes photobiont degradation and carbon starvation in a boreal climate sentinel lichen

The long-term potential for acclimation by lichens to changing climates is poorly known, despite their prominent roles in forested ecosystems. Although often considered “extremophiles,” lichens may not readily acclimate to novel climates well beyond historical norms. In a previous study, Evernia mesomorpha transplants in a whole-ecosystem climate change experiment showed drastic mass loss after 1 yr of warming and drying; however, the causes of this mass loss were not addressed. We examined the causes of this warming-induced mass loss by measuring physiological, functional, and reproductive attributes of lichen transplants. Severe loss of mass and physiological function occurred above +2°C of experimental warming. Loss of algal symbionts (“bleaching”) and turnover in algal community compositions increased with temperature and were the clearest impacts of experimental warming. Enhanced CO 2 had no significant physiological or symbiont composition effects. The functional loss of algal photobionts led to significant loss of mass and specific thallus mass (STM), which in turn reduced water-holding capacity (WHC). Although algal genotypes remained detectable in thalli exposed to higher stress, within-thallus photobiont communities shifted in composition toward greater diversity. The strong negative impacts of warming and/or lower humidity on Evernia mesomorpha were driven by a loss of photobiont activity. Analogous to the effects of climate change on corals, the balance of symbiont carbon metabolism in lichens is central to their resilience to changing conditions.

54 ENVIRONMENTAL SCIENCES↗

Prediction of reinforcement corrosion using corrosion induced cracks width in corroded reinforced concrete beams

This paper studies the evolution of reinforcement corrosion in comparison to corrosion crack width in a highly corroded reinforced concrete beam. Cracking and corrosion maps of the beam were drawn and steel reinforcement was recovered from the beam to observe the corrosion pattern and to measure the loss of mass of steel reinforcement. Maximum steel cross-section loss of the main reinforcement and average steel cross-section loss between stirrups were plotted against the crack width. The experimental results were compared with existing models proposed by Rodriguez et al., Vidal et al. and Zhang et al. Time prediction models for a given opening threshold are also compared to experimental results. Steel cross-section loss for stirrups was also measured and was plotted against the crack width. It was observed that steel cross-section loss in the stirrups had no relationship with the crack width of longitudinal corrosion cracks. -- Highlights: •Relationship between crack and corrosion of reinforcement was investigated. •Corrosion results of natural process and then corresponds to in-situ conditions. •Comparison with time predicting model is provided. •Prediction of load-bearing capacity from crack pattern was studied.

36 MATERIALS SCIENCE↗

Structural Degradation of High Voltage Lithium Nickel Manganese Cobalt Oxide (NMC) Cathodes in Solid-State Batteries and Implications for Next Generation Energy Storage

In this study, we report the stability of the layered high voltage cathode NMC622 with respect to a standard liquid electrolyte and in an all solid-state configuration. NMC622 cathodes with a (104) orientation were found to suffer from degradation at high voltage (4.5 V vs Li/Li + ) due to electrolyte-promoted degradation of the layered structure in a carbonate electrolyte. The lithium phosphorus oxynitride (LiPON) electrolyte was able to suppress the extent of this decomposition in solid-state cells but not totally prevent it from occurring. In the solid-state cells the capacity decreased from 203 to 93 mAh/g in the first cycle and from 93 to 79 mAh/g over the subsequent 99 cycles, whereas, after 20 cycles, the liquid cell charge capacity was dominated by the irreversible electrolyte degradation. Furthermore, the interfacial resistances of the solid-state cells were stable with cycling, suggesting minimal degradation of the NMC622/LiPON interface and incumbent losses due to structural evolution associated with cathode orientation. This data indicates that accessing stable high voltage capacity in NMCs will not be enabled by simply stabilizing the cathode–electrolyte interface. Optimizing cathode crystallographic orientation may be the key to accessing this high voltage regime.

25 ENERGY STORAGE↗

Optimal Transmission Line Switching under Geomagnetic Disturbances

Recently, there have been increasing concerns about how geomagnetic disturbances (GMDs) impact electrical power systems. Geomagnetically-induced currents (GICs) can saturate transformers, induce hot spot heating and increase reactive power losses. These effects can potentially cause catastrophic damage to transformers and severely impact the ability of a power system to deliver power. To address this problem, we develop a model of GIC impacts to power systems that includes 1) GIC thermal capacity of transformers as a function of normal Alternating Current (AC) and 2) reactive power losses as a function of GIC. We also use this model to derive an optimization problem that protects power systems from GIC impacts through line switching, generator dispatch, and load shedding. We then employ state-of-the-art convex relaxations of AC power flow equations to lower bound the objective. We demonstrate the approach on a modified RTS96 system and UIUC 150-bus system and show that line switching is an effective means to mitigate GIC impacts. We also provide a sensitivity analysis of decisions with respect to GMD direction.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cooperative Transmission Expansion Planning Experiment Data and Results

GO WEST is an open-source power grid modeling framework for U.S. Western Interconnection, which allows users to tailor the model depending on their research study and science questions. It covers 28 balancing authorities (BA) and 12 states in U.S. Western Interconnection. GO WEST allows users to select different number of nodes and come up with a simplified network by utilizing 10,000 nodal topology of U.S. Western Interconnection created by Texas A&M University. Users can try and select different number of nodes, mathematical formulations (linear programming vs. mixed-integer linear programming), transmission line limit scaling factors, and hurdle rate scaling factors. GO WEST offers a unit commitment and economic dispatch (UC/ED) module to simulate grid operations on an hourly scale. In this sense, users can calibrate and validate their model versions by comparing model outputs to historical datasets. TEP is an open-source transmission capacity expansion model, built on GO WEST framework. It utilizes linear programming to optimize transmission capacity addition investment on existing lines within GO WEST framework. In this sense, TEP model only increases the thermal capacity of existing transmission lines and does not add new lines to the system, which leaves the topology preserved. TEP minimizes the total cost of the system which comprises the operational cost of satisfying electricity demand (i.e., generation cost), cost of loss of load (i.e., unserved energy), cost of power flow, and cost of new transmission capacity additions (i.e., investment cost). In order to use TEP model, users need to create scenarios with GO WEST framework. In this analysis, outputs from several models are used to create future inputs to GO WEST and TEP models, including GCAM-USA, TELL, CERF and reV. This dataset includes experiment inputs and outputs from three different transmission expansion scenarios (cooperative, intermediate, and individual) for 2019 and 2059. For 2019, a base scenario to illustrate the default (i.e., historical) power grid operations is also included. This study utilizes rcp45hotter_ssp3 scenario from a previous version of GCAM-USA simulations. Sources of the shapefiles in supplementary data are HIFLD Open and U.S. Energy Atlas. Please see the README file for a detailed description of the main and supplementary data.

Capacity Expansion Model↗

Cumulative effects of fire and drought in Mediterranean ecosystems

Here, the occurrence of multiple disturbances can jointly affect the recovery capacity of ecosystems, potentially leading to changes in vegetation dynamics or loss of resilience. The effects of interacting disturbances on ecosystems are, however, not well understood. We use a model system based on Mediterraneantype ecosystems (MTEs) to examine how the interplay between vegetation regeneration traits and compound, stochastic disturbances modulate ecosystem dynamics. We developed a state-and-transition simulation model including two tree species with contrasting regeneration strategies (seeder vs. resprouter) and a shrubland formation. We aim to assess potential compositional switches under contrasted scenarios of compound fire-drought regimes, and to characterize the cumulative effects of fire-drought (synergism vs. antagonism) relative to the effects of individual disturbance regimes. Our simulation results indicate that interaction between moderate fire and sporadic drought recurrence-as opposed to chronic dryness-can act as a strong mechanism generating highly heterogeneous landscapes in which different regeneration types coexist, as observed in MTEs. Resprouters dominated under individual, moderate disturbance regimes of fire or drought, whereas the interaction of the two disturbances promoted the longterm coexistence of both tree regeneration strategies. However, shrubland expansion and persistence at the expanse of forests was favored by increases in drought recurrence and associated fire-drought interactions, highlighting the potential for important vegetation changes in MTEs under climate change. Overall, the cumulative effects of fire and drought can lead to distinct landscape configurations under moderate disturbance regimes that are otherwise only attained under high frequency of individual disturbances. At the ecosystem level, however, we suggest that disturbance-induced vegetation dynamics can modify vegetation sensitivity and resilience to further disturbances precluding the prevalence of synergistic effects of the two disturbances.

54 ENVIRONMENTAL SCIENCES↗

In Situ Synthesized Hydroxyapatite—Cellulose Nanofibrils as Biosorbents for Heavy Metal Ions Removal

The synthesis of hydroxyapatite (HAp) in the presence of cellulose nanofibrils (CNF) or TEMPO-oxidized CNF (TCNF) was performed in situ by wet chemical precipitation process, using chemical precursors, to hybrid a low-cost biosorbents for removal of Co{sup 2+} as a model heavy metal ion. The removal is investigated by batch adsorption method depending on the pH value, the dosage of adsorbent, initial Co{sup 2+} concentration and the contact time of adsorption. The removal of Co{sup 2+} reached the maximum (87%) at pH 6 by using a dosage of 0.5 g L{sup −1}. The TCNFs is shown to increase the nucleation and growth of the HAp synthesized, providing higher surface area (138 m{sup 2} g{sup −1}) with lower pore diameter (11.89 nm), compared to the CNFs based hybrid (135 m{sup 2} g{sup −1}, 14.42 nm) or pure HAp (118 m{sup 2} g{sup −1}, 13.32 nm), however, both resulting to a higher adsorption capacity (25 mg g{sup −1}) of Co{sup 2+} compared to HAp or TCNF (20–22 mg g{sup −1}). The adsorption is follows primarily by pseudo-first and Elovic order kinetic models which is due to the physisorption of Co{sup 2+} and surface ionic interactions with available negative phosphate (from HAp) and/or carboxylic (from TCNF) groups, fitting well with the Freundlich adsorption isotherm, and secondly due to the ion-exchange mechanism of Co{sup 2+} with Ca{sup 2+} from HAp. Both hybrid adsorbents show good adsorption (≥40%) capacity even after third reusing cycle, and high temperature stability (weight loss of 14%) up to 1000 °C, however, the CNF-HAp hybrid represent a high-value alternative to relatively costly TCNF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elastic NaxMoS2-carbon-BASE triple interface direct robust solid-solid interface for all-solid-state Na-S batteries

The promises of all-solid-state (ASS) sodium batteries for the next generation energy storage are widely recognized but their developments have been severely constrained by the difficulties to design favorable solid-solid interfaces for unhindered Na-ion transport. Using the most promising ß?-Al2O3 solid state electrolyte (BASE) as a platform, we demonstrate here a triple nanojunction strategy that provides simultaneous strong Na adhesion and continuous Na-ions diffusion at solid-solid interface. Such triple junctions (NaxMoS2-carbon-BASE) were constructed by adhering ternary composite Na anodes containing dispersed 3 wt% MoS2 and 3 wt% carbon on BASE, and provide nearly complete adhesion of Na on BASE with a much smaller contact angle (~ 45o vs. 120o of pristine Na). The composite Na anodes exhibited ~ 3 times improved elastic property and the synergy of NaxMoS2 and carbon provides the required ionic and electronic diffusion channels at solid-solid interface, which significantly improve Na utilization and resist premature failure due to loss of solid-solid contact as Na shrink during high capacity stripping. As a result, Na metal at the triple junction exhibited more than five time reduced charge transfer resistance and at least 200 hours stable battery cycling at practical current densities. The novel anode architecture also enabled high capacity cycling of prototype ASS sodium sulfur batteries when coupled with advanced sulfur cathodes containing intrinsic Na-ions diffusion channels and redox catalytic mediators, leading to stable cycling with specific capacity of 1110 mAh g-1.

ß”-Al2O3 solid electrolyte, solid state batteries,↗

CO 2 Capture with Capsules of Ionic Liquid/Amines

Carbon capture remains an urgent issue that has gained a great deal of attention over the past few decades. Aqueous amines have excellent selectivity, but present corrosion and volatility issues, whereas ionic liquids (ILs) have negligible volatility and tunable physical properties, but high viscosities. One approach to improve the practical performance of these liquids is encapsulating them in a CO 2 permeable polymer shell to enhance the accessibility of the liquid and the CO 2 absorption rate. In this work, we report the encapsulation of a mixture of amine and IL (i.e., monoethanolamine (MEA) and 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM][BF 4 ])) and demonstrate enhanced carbon capture performance. A soft-template approach and interfacial polymerization are used to give capsules with liquid core (64 wt %) and polyurea shell. Compared to the bulk liquid, the encapsulated liquid shows improved thermal stability over cycles of absorption at 25 °C, and desorption at 75 °C. The capsules with core of [BMIM][BF 4 ]-MEA show 0.2 mol CO 2 /kg of capsules at 1 bar CO 2 , compared to the bulk liquid, which has 0.05 mol CO 2 /kg of sorbent. This is attributed to the limited evaporation of the amines. Alternatively, the same capsules but with 5 wt % of piperazine (Pz) in the core have doubled gravimetric CO 2 capacity of the capsules (0.4 mol CO 2 /kg of capsules); performance is evaluated over 10 capture–release cycles showing minimal mass loss. Characterization of the CO 2 uptake of the polymer shell itself reveals that the shell contributes only ~10% of the observed capacity, likely attributed to amine functionalities of the polymer. Here, this facile approach to encapsulating such “active” liquids can be applied to other CO 2 selective solvents that are volatile, viscous, and corrosive.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stabilizing a Li–Mn–O Cathode by Blocking Lattice O Migration through a Nanoscale Phase Complex

Among all intercalation cathodes for Li-ion batteries, Li–Mn–O layered oxides offer the highest initial energy density at the lowest cost, due to the joint contribution from cationic and anionic redox chemistry. However, the poor cycling capability, resulting from the continuous lattice O loss at high potentials (>4.5 V), hinders practical applications. Herein, we employed phase complex engineering to obtain a new Li–Mn–O nanohybrid cathode featuring the uniform and coherent integration of layered nanodomains and spinel nanodomains. The combination of DFT calculations, synchrotron-based transmission X-ray microscopy, in situ differential electrochemical mass spectrometry, in situ synchrotron XRD, and electrochemical tests demonstrated that the O migration path in layered nanodomains was blocked by the neighboring spinel nanodomains with a higher oxygen vacancy migration energy, thus effectively suppressing the irreversible lattice O loss at high potentials and enhancing the cycling stability in both capacity and average voltage. Finally, the strategy is experimentally demonstrated to be effective and it leads to a new path for developing stable high-energy-density cathode materials.

25 ENERGY STORAGE↗