Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitive data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Updating the Standard Spatial Observer for Contrast Detection

Watson and Ahmuada (2005) constructed a Standard Spatial Observer (SSO) model for foveal luminance contrast signal detection based on the Medelfest data (Watson, 1999). Here we propose two changes to the model, dropping the oblique effect from the CSF and using the cone density data of Curcio et al. (1990) to estimate the variation of sensitivity with eccentricity. Dropping the complex images, and using medians to exclude outlier data points, the SSO model now accounts for essentially all the predictable variance in the data, with an RMS prediction error of only 0.67 dB.

Ahumada, Albert J.↗

A Low Noise, Microprocessor-Controlled, Internally Digitizing Rotating-Vane Electric Field Mill for Airborne Platforms

This paper reports on a new generation of aircraft-based rotating-vane style electric field mills designed and built at NASA's Marshall Spaceflight Center. The mills have individual microprocessors that digitize the electric field signal at the mill and respond to commands from the data system computer. The mills are very sensitive (1 V/m per bit), have a wide dynamic range (115 dB), and are very low noise (+/-1 LSB). Mounted on an aircraft, these mills can measure fields from +/-1 V/m to +/-500 kV/m. Once-per-second commanding from the data collection computer to each mill allows for precise timing and synchronization. The mills can also be commanded to execute a self-calibration in flight, which is done periodically to monitor the status and health of each mill.

Bateman, M. G.↗

Comparative performance of double-focus and quadrupole mass spectrometers

Light-weight flight type double focus and quadruple mass spectrometer models were compared. Data cover size, weight, and power sensitivity required to achieve same resolution sensitivity at given mass number. Comparison was made using mathematical relationships. Analysis was confined to equal ion source area sensitivity variations not more than 40% over mass range.

Wilson, S. K.↗

An etiological study of phthalate self-contamination of spacecraft and contamination from their earthly environs

Phthalates are very objectionable contaminants in space experiments because of their strong absorption in the UV and IR regions of the spectrum. Thus, even minute amounts of these compounds migrating to optical equipment, in test or space flight conditions, can seriously compromise the results of experiments by altering the sensitivity of the functional equipment. Volatility data of the phthalates and other plasticizers are presented in addition to UV spectra of ultrathin films of these same types of compounds. Sources of plasticizer contamination are revealed with special recognition given to di-2-ethylhexyl phthalate (DEHP), the single most ubiquitous plasticizer in use. A surprisingly large percentage of the outgassing condensates from vacuum testing of spacecraft contain DEHP as well as other plasticizers. IR and gas chromatography/mass spectroscopy methods were used to analyze samples from spacecraft. Methods for successful reduction of plasticizers and other contaminants are mentioned.

Gross, F. C.↗

Space shuttle: A comparison of wind tunnel facility data on the 040A space shuttle orbiter configuration

A series of comparisons made on the longitudinal and lateral directional stability and control characteristics of the baseline 040A space shuttle orbiter configuration is documented. The data used for the comparisons were obtained from five wind tunnel tests conducted in four different wind tunnel facilities. The media for comparison were the aerodynamic slope values plotted as a function of Mach number for the different facilities. The slopes were computed using the SADSAC system and have been reduced relative to a common reference system. Data used for the comparison were selected based on a common baseline configuration. Identical configurations were available in all cases except MSFC 551 where an off-baseline vertical tail was tested. Some of the factors considered in comparing the various data were balance operating ranges and sensitivities, Reynolds number differences, scaling effects and control deflection accuracies.

Gyorfi, R. A.↗

Accelerated life testing of spacecraft subsystems

The rationale and requirements for conducting accelerated life tests on electronic subsystems of spacecraft are presented. A method for applying data on the reliability and temperature sensitivity of the parts contained in a sybsystem to the selection of accelerated life test parameters is described. Additional considerations affecting the formulation of test requirements are identified, and practical limitations of accelerated aging are described.

Wiksten, D.↗

Prototype ultrasonic instrument for quantitative testing

A prototype ultrasonic instrument has been designed and developed for quantitative testing. The complete delivered instrument consists of a pulser/receiver which plugs into a standard oscilloscope, an rf power amplifier, a standard decade oscillator, and a set of broadband transducers for typical use at 1, 2, 5 and 10 MHz. The system provides for its own calibration, and on the oscilloscope, presents a quantitative (digital) indication of time base and sensitivity scale factors and some measurement data.

Lynnworth, L. C.↗

Observations of high-energy gamma rays

Ground based instruments designed to measure high energy gamma ray sources as a function of Cerenkov light bursts are described. Data are also included on the sensitivity, advantages, and disadvantages of the instruments.

Fazio, G. G.↗

Test program on the contamination of ultraviolet region mirrors by Apollo Telescope Mount materials

Results are presented of testing performed to measure the effects of material outgas products on the reflectances of ultraviolet-region mirrors. These tests were to provide data on changes of ultraviolet reflectances of first-surface mirrors which had been exposed to the outgas products of selected materials under specific time and thermal-vacuum conditions. The requirement for such data was based on the extreme sensitivity of the sophisticated optical instruments in the Skylab mission's Apollo Telescope Mount (ATM) to condensed outgas products from materials, and on the desire to insure that no serious hazard of contaminating these instruments existed.

Austin, J. D.↗

A design study of a photorefractive page composer

A laboratory demonstration and preliminary system analysis of a page composer designed to have the dual advantages of low optical loss and small size, were reported. The current page composer is optically addressed and functions by virtue of optically induced refractive index changes in the active material. Laboratory demonstrations of the device were successfully performed using 10 x 10 bit and 128 x 128 bit data arrays. It was established that the only significant obstacle to the construction of a brass-board model working at megabit data rates is the lack of sensitivity of the photorefractive materials which were considered during the course of this study. Possible materials for future consideration are the photoplastics. While they have more than the required sensitivity, their stability and suitability for double exposure holography was not investigated. If a sufficiently sensitive material is found, then the photorefractive page composer could be built to perform in a highly efficient fashion which would result in a overall reduction of the size of the memory system and an easing of the requirements upon the sensitivity of the holographic recording material.

Source record↗

The radial dependence of the zodiacal light

The asteroid/meteoroid detector (Sisyphus) has, in addition to its primary role of detecting and analyzing individual meteoroids, been used for measuring the brightness of the night sky from its platform on board the Pioneer 10 spacecraft. This spacecraft has traversed the asteroid belt and will fly by Jupiter in December 1973. It was quickly found that the brightness of the night sky in the antisolar hemisphere decreased rapidly with increasing distance from the sun. This decrease is due solely to the decrease in the brightness of the zodiacal light. The heliocentric dependence of the zodiacal light has been deduced from several months of data. Some data are shown to illustrate the sensitivity of the instrument to features in the night sky and the technique used for subtracting out the integrated brightness due to starlight is described. Preliminary results showing the decrease of the zodiacal light with solar distance is not inconsistent with an inverse square dependence.

Zook, H. A.↗

Neutral hydrogen in the direction of the Small Magellatic Cloud and the limits of an extragalactic soft X-ray flux

Previously reported X-ray data from the vicinity of the Small Magellanic Cloud (SMC) have been reanalyzed using H I data from a more detailed and sensitive 21-cm survey of this region. The results support the previous conclusion: assuming that the interstellar material absorbs according to the cross sections of Brown and Gould (1970), at least 75 per cent of the observed 0.25-keV X-ray flux is of local origin. The corollary problem of placing a cosmologically useful upper limit on the extragalactic flux will be difficult to solve until the behavior of the local component is better understood; but if the local flux is isotropic, a 3-sigma upper limit of 240 photons per (sq cm s sr keV) at 0.25 keV may be placed on a flux originating beyond the SMC. Tables of H I column density are given for an area 30 deg by 30 deg about the SMC. The high-velocity component, presumably associated with the Magellanic Cloud system, and the galactic disk component are tabulated separately.

Mccammon, D.↗

Investigation of thematic mapper spatial, radiometric, and spectral resolution

Low-altitude aircraft scanner data were employed in simulating the spatial resolution, radiometric sensitivity and spectral bandwidth parameters of the proposed Landsat Thematic Mapper (TM). The 30 to 40 m resolution of the TM was found to provide significant improvement over current Landsat resolution (50 to 60 m) in crop mensuration, especially for Western Europe and India where field sizes average from one to four hectares. In terms of radiometric sensitivity, a noise equivalent reflectance value of 0.5% was held to be necessary for discrimination of spectrally similar data; in addition, all of the six proposed TM spectral bands were shown to be necessary for monitoring at some point during the growing season.

Morgenstern, J. P.↗

Application of an ultrasonic phase insensitive receiver to material measurements

The theory of a phase insensitive receiver based on acousto-electric effect is presented along with experimental characteristics of a CdS acousto-electric converter (AEC). Since the AEC is nearly phase insensitive, it is ideal for measurements in inhomogeneous materials and/or materials with irregular flatness and parallelism. Through transmission ultrasonic C-scan data of phantom flaws demonstrates a significant improvement in flaw characterization with an AEC over that of a conventional transducer. In addition, measurements with conventional transducers in anisotropically stressed metal samples are shown to lead to grossly inaccurate results due to phase sensitivity. Various other measurements are presented with data contrasting conventional transducers with an AEC in specific NDE applications.

Heyman, J. S.↗

Application of an ultrasonic phase insensitive receiver to material measurements

The theory of a phase insensitive receiver based on acousto-electric effect is presented along with experimental characteristics of a CdS acousto-electric converter (AEC). Since the AEC is nearly phase insensitive, it is ideal for measurements in inhomogeneous materials and/or materials with irregular flatness and parallelism. Through transmission ultrasonic C-scan data of phantom flaws demonstrates a significant improvement in flaw characterization with an AEC over that of a conventional transducer. In addition, measurements with conventional transducers in anisotropically stressed metal samples are shown to lead to grossly inaccurate results due to phase sensitivity. Various other measurements are presented with data contrasting conventional transducers with an AEC in specific NDE applications.

Heyman, J. S.↗

Fracture modes in off-axis fiber composites

Criteria were developed for identifying, characterizing, and quantifying fracture modes in high-modulus graphite-fiber/resin unidirectional composites subjected to off-axis tensile loading. Procedures are described which use sensitivity analyses and off-axis data to determine the uniaxial strength of fiber composites. It was found that off-axis composites fail by three fracture modes which produce unique fracture surface characteristics. The stress that dominates each fracture mode and the load angle range of its dominance can be identified. Linear composite mechanics is adequate to describe quantitatively the mechanical behavior of off-axis composites. The uniaxial strengths predicted from off-axis data are comparable to these measured in uniaxial tests.

Sinclair, J. H.↗

Infrared Astronomical Satellite /IRAS/ and Shuttle Infrared Telescope Facility /SIRTF/ - Implications of scientific objectives on focal plane sensitivity requirements

The full potential of infrared astronomy can be realized only through observations made with space-based telescopes cooled to cryogenic temperatures. The paper outlines the scientific mission, system description, and focal plane requirements for two cryogenic telescopes: the Infrared Astronomical Satellite (IRAS) and the Shuttle Infrared Telescope Facility (SIRTF). IRAS, a 60-cm superfluid-helium-cooled telescope system, will perform a one-year 8-120-micron IR sky survey; it will provide results of high reliability and sensitivity, produce the first complete survey data for the 30-120-micron region, and fill in missing portions (spectrally and spatially) of previous surveys short of 30 microns; its focal plane assembly is being designed to approach background-limited performance with an array of 62 discrete detectors. The SIRTF design will allow detailed follow-up studies in the 1-1000-micron range with a 116-160-cm observatory-class instrument. The Shuttle sortie capability introduces the unique SIRTF concept of an easily refurbishable or replaceable focal plane instrument complement in an orbiting cryogenic telescope.

Mccreight, C. R.↗