Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

An analysis of I/O efficient order-statistic-based techniques for noise power estimation in the HRMS sky survey's operational system

Noise power estimation in the High-Resolution Microwave Survey (HRMS) sky survey element is considered as an example of a constant false alarm rate (CFAR) signal detection problem. Order-statistic-based noise power estimators for CFAR detection are considered in terms of required estimator accuracy and estimator dynamic range. By limiting the dynamic range of the value to be estimated, the performance of an order-statistic estimator can be achieved by simpler techniques requiring only a single pass of the data. Simple threshold-and-count techniques are examined, and it is shown how several parallel threshold-and-count estimation devices can be used to expand the dynamic range to meet HRMS system requirements with minimal hardware complexity. An input/output (I/O) efficient limited-precision order-statistic estimator with wide but limited dynamic range is also examined.

Zimmerman, G. A.↗

Novel position sensor technologies for microaccelerometers

An important new approach for vehicle guidance and control is based on the use of compact, low-mass, low-cost sensors integrated with the vehicle structure. Many advantages of this approach lead to new capabilities. However, the development of compact guidance and control sensors leads to a variety of fundamental physical problems associated with sensor sensitivity and noise. For example, as sensor size is reduced, it becomes necessary to improve the sensitivity of the sensor signal detection mechanism. These challenges to sensor development will be described. Recent developments at JPL, based on new position sensor principles such as electron tunneling, have produced a series of novel, ultra-high sensitivity micro-sensors and micro-instruments. Included among the applications demonstrated, are a high sensitivity micro-accelerometer and micro-seismometer. In this paper, the fundamental limits of conventional position sensors will be discussed and a new position sensor for advanced accelerometers will be described.

Vanzandt, T. R.↗

Supply Current Diagnosis in VLSI

This paper presents a technique based upon the power supply current signature (cd) which allows for the testing of mixed-signal systems, in situ. Through experiments with a microprocessor, the cd is shown to contain important information concerning the operational status of the system which may be easily extracted using approaches based on statistical signal detection theory. The fault-detection performance of these techniques is compared to that achieved through auto-regressive modeling of the cd.

Frenzel, J. F.↗

Environmental projects. Volume 15: Environmental assessment: Proposed 1-megawatt radar transmitter at the Mars site

The Goldstone Deep Space Communications Complex (GDSCC), located in the Mojave Desert about 64.5 km (40 mi) north of Barstow, California. and about 258 km (160 mi) northeast of Pasadena, California, is part of the National Aeronautics and Space Administration's (NASA's) Deep Space Network (DSN), one of the world's larger and more sensitive scientific telecommunications and radio navigation networks. The Goldstone Complex is managed, technically directed, and operated for NASA by the Jet Propulsion Laboratory (JPL) of the California Institute of Technology in Pasadena, California. Activities at the GDSCC support the operation of six parabolic dish antennas located at five separate sites called Deep Space Stations (DSS's). Four sites, named Echo, Mars, Uranus, and Apollo, are operational for space missions, while the remaining Venus Site is devoted to research and development activities. The Mars Site at the GDSCC contains two antennas: the Uranus antenna (DSS 15, 34 m) and the Mars antenna (DSS 14, 70 m). This present volume deals solely with the DSS-14 Mars antenna. The Mars antenna not only can act as a sensitive receiver to detect signals from spacecraft, but it also can be used in radar astronomy as a powerful transmitter to send out signals to probe the solar system. At present, the Mars antenna operates as a continuous-wave microwave system at a frequency of 8.51 GHz at a power level of 0.5 MW. JPL has plans to upgrade the Mars antenna to a power level of 1 MW. Because of the anticipated increase in the ambient levels of radio frequency radiation (RFR), JPL retained Battelle Pacific Northwest Laboratories (BPNL), Richland, Washington, to conduct an environmental assessment with respect to this increased RFR. This present volume is a JPL-expanded version of the BPNL report titled Environmental Assessment of the Goldstone Solar System Radar, which was submitted to JPL in Nov. 1991. This BPNL report concluded that the operation of the upgraded Mars antenna at the GDSCC, with its increased potential electromagnetic radiation hazards and interferences, would have no significantly adverse biological, physical, or socioeconomic effects on the environment. Thus, a Finding of No Significant Impact (FONSI) is appropriate in accordance with local, State, Federal, and NASA environmental rules and regulations.

Source record↗

New methods of generation of ultrashort laser pulses for ranging

To reach the millimeter satellite laser ranging accuracy, the goal for nineties, new laser ranging techniques have to be applied. To increase the laser ranging precision, the application of the ultrashort laser pulses in connection with the new signal detection and processing techniques, is inevitable. The two wavelength laser ranging is one of the ways to measure the atmospheric dispersion to improve the existing atmospheric correction models and hence, to increase the overall system ranging accuracy to the desired value. We are presenting a review of several nonstandard techniques of ultrashort laser pulses generation, which may be utilized for laser ranging: compression of the nanosecond pulses using stimulated Brillouin and Raman backscattering; compression of the mode-locked pulses using Raman backscattering; passive mode-locking technique with nonlinear mirror; and passive mode-locking technique with the negative feedback.

Jelinkova, Helena↗

Search for Extraterrestrial Intelligence (SETI)

Various aspects of project SETI are discussed. Some of the topics discussed include spectrum analyzers, signal processing, sky surveys, radiotelescopes, high resolution microwave survey, Deep Space Network, and signal detection.

Billingham, John↗

Tracking photosynthetic efficiency with narrow-band spectroradiometry

Narrow-waveband spectroradiometry presents the possibility of detecting subtle signals closely related to the current physiological state of vegetation. One such signal related to the epoxidation state of the xanthophyll cycle pigments, violaxanthin, antheraxanthin, and zeaxanthin is discussed. Recent advances in plant ecophysiology demonstrated a close relationship between these pigments and the regulatory state of photosystem 2 in photosynthesis. Our recent field studies of sunflower (Helianthus annuus) and oak (Quercus agrifolia) demonstrated that a 'xanthophyll signal' can be isolated from the diurnal reflectance spectra of intact canopies. Furthermore, the xanthophyll signal can be used to derive a 'physiological reflectance index' (PRI) that closely correlates with the actual photosynthetic efficiency (defined as the photosynthetic rate divided by the incident PAR) in closed canopies. If these signals were detectable in Airborne Visible/Infrared Imaging Spectrometers (AVIRIS) images, they could lead to improved remote estimates of photosynthetic fluxes.

Gamon, John A.↗

Bidirectional reflectance of oceanic waters: A comparison of modeled and measured upward radiance fields

The bidirectional reflectance of oceanic waters is conveniently described in a normalized way by forming the ratio of the upwelling irradiance E(sub u) to any upwelling radiance L(sub u)(theta prime, phi). This ratio, Q (theta prime, theta(sub 0), (phi(sub 0) - phi), where theta prime, phi are the nadir and azimuth angles for the upward radiance and theta(sub 0), phi(sub 0) are the zenith and azimuth angles of the Sun, has been determined from measurements at sea and computed via Monte Carlo simulations using the inherent optical properties measured in the field and appropriate boundary conditions (clear sky, no wind, varying Sun angle). Experimental ad computed Q values are in excellent agreement. This successful comparison confirms the importance of the bidirectional character of ocean reflectance, already pointed out from a purely numerical approach without field validation, and corroborates the extended range of the Q variations. The later point is of importance when interpreting the marine signals detected by an ocean color satellite-borne sensor. The validation is extended by considering the historical data for the radiance distributions in Lake Pend Oreille determined at various depths. The closure issue in ocean optics is examined by solving the direct problem of radiative transfer and through a model-data comparison in terms of radiance field.

Morel, Andre↗

Improved Noise-Power Estimators Based On Order Statistics

Technique based on order statistics enables design of improved noise-power estimators. In original intended application, noise-power estimators part of microwave-signal-processing system of Search for Extraterrestrial Intelligence project. Involves limiting dynamic range of value to be estimated; making it possible to achieve performance of order-statistical estimator with simple algorithms and equipment and with only one pass over input data. Technique also applicable to other signal-detection systems and to image-detection systems required to exhibit constant false-alarm rates.

Zimmerman, George A.↗

Circular Metal/Semiconductor/Metal Photodetectors

Metal/semiconductor/metal (MSM) photodetectors with multiple concentric circular electrodes developed. Some electrical characteristics expected superior to those of older MSM photodetectors containing interdigitated straight electrodes. Response times smaller and shorter, and breakdown voltages larger. Decrease in capacitance allows greater signal-detection bandwidth. Important advantage in fiber-optic telecommunication systems, in which photodectors central components in receiver circuits. Increasing bandwidth of such photodetector enables receiver to handle larger number of channels or increased information rate in each channel.

Mcadoo, James A.↗

The Effects of Nearby Clusters of Galaxies on the Microwave Background Radiation

This project proposed to use the COBE (Cosmic Background Explorer) DMR sky-maps to measure the anisotropies introduced into the microwave background radiation by the Sunyaev-Zel'dovich and Rees-Sciama effects of nearby clusters and superclusters of galaxies. We intended to seek these effects by making maps of the best-fit anisotropies on particular angular scales and comparing the apparent anisotropies near target clusters and superclusters with the statistical noise and sky variance. The locations of the clusters and superclusters were to be found using HEAO-1 (High Energy Astronomy Observatory) A2 and Einstein X-ray maps. Checks against biases were to be made using radio and X-ray sky-maps as guides to the properties of the clusters and superclusters. Any signals detected would have implications for the gas properties and baryonic masses of clusters and superclusters. The scientific background, project activities and references to published papers are included.

Birkinshaw, M.↗

Design and Performance of the Astro-E/XRS Signal Processing System

We describe the signal processing system of the Astro-E XRS Instrument. The Calorimeter Analog Processor (CAP) provides bias and power for the detectors and amplifies the detector signals by a factor of 20,000. The Calorimeter Digital Processor (CDP) performs the digital processing of the calorimeter signals, detecting X-ray pulses and analyzing them by optimal filtering. We describe the operation of pulse detection, pulse height analysis, and risetime determination. We also discuss performance, including the three event grades (hi-res, mid-res, and low-res), anticoincidence detection, counting rate dependence, and noise rejection.

Boyce, K. R.↗

TRMM and its Connection to the Global Water Cycle

The importance of quantitative knowledge of tropical rainfall, its associated latent heating and variability is summarized in the context of the global hydrologic cycle. Much of the tropics is covered by oceans. What land exists, is covered largely by rainforests that are only thinly populated. The only way to adequately measure the global tropical rainfall for climate and general circulation models is from space. The Tropical Rainfall Measuring Mission (TRMM) orbit is inclined 35 degrees leading to good sampling in the tropics and a rapid precession to study the diurnal cycle of precipitation. The precipitation instrument complement consists of the first rain radar to be flown in space (PR), a multi-channel passive microwave sensor (TMI) and a five-channel VIS/IR (VIRS) sensor. The precipitation radar operates at a frequency of 13.6 GHz. The swath width is 220 km, with a horizontal resolution of 4 km and the vertical resolution of 250 m. The minimum detectable signal from the precipitation radar has been measured at - 17 dBZ. The TMI instrument is designed similar to the SSM/I with two important changes. The 22.235 GHz water vapor absorption channel of the SSM/I was moved to 21.3 GHz in order to avoid saturation in the tropics and 10.7 GHz V&H polarized channels were added to expand the dynamic range of rainfall estimates. The resolution of the TMI varies from 4.6 km at 85 GHz to 36 km at 10.7 GHz. The visible and infrared sensor (VIRS) measures radiation at 0.63, 1.6, 3.75, 10.8 and 12.0 microns. The spatial resolution of all five VIRS channels is 2 km at nadir. In addition to the three primary rainfall instruments, TRMM will also carry a Lightning Imaging Sensor (LIS) and a Clouds and the Earth's Radiant Energy System (CERES) instrument. This presentation will focus primarily on the advances in our understanding of tropical rain systems needed to interpret the TRMM data. Global averages, as well as case studies from TRMM radar (PR), the TRMM Microwave Imager (TMI) and Visible and Infrared Sensor (VIRS) will be presented. Comparisons and contrasts among the different sensors will be drawn. Results will also be compared to previous rainfall climatologies generated from the SSM/I instrument. In particular this paper will focus on the synergy between the TRMM radar and passive microwave radiometer and what we have learned from its synergy.

Kummerow, Christian↗

The Design and Performance of the Astro-E/XRS Signal Processing System

We describe the signal processing system of the Astro-E XRS instrument. The Calorimeter Analog Processor (CAP) provides bias and power for the detectors and amplifies the detector signals by a factor of 20,000. The Calorimeter Digital Processor (CDP) performs the digital processing of the calorimeter signals, detecting X-ray pulses and analyzing them by optimal filtering. We describe the operation of pulse detection, pulse height analysis, and risetime determination. We also discuss performance, including the three event grades (hi-res, mid-res, and low-res), anticoincidence detection, counting rate dependence, and noise rejection.

Boyce, K. R.↗

The Variability and Spectrum of NGC 4051 from Deep, Simultaneous EUVE and XTE Observations

We present timing and spectral analysis of the data collected by the Extreme Ultraviolet Explorer Satellite (EUVE) for the Seyfert 1 galaxy NGC 4051 during 1996. NGC 4051 was observed twice in May 1996 and again in December 1996 for a total of more than 200 ksec. The observations were always simultaneous with hard X-ray observations conducted with the X-Ray Timing Explorer (XTE). The EUVE light curves are extremely variable during each observation, with the maximum variability during May 1996 when we registered changes by a factor of 21 over 8 hours and more than a factor of 24 variations from peak to minimum. We detected signal in the EUVE spectrograph in the 75-100 Arange which is well fitted by absorbed power law models. We will illustrate the results of our spectral and detailed power spectrum analysis for the simultaneous EUVE and XTE spectra and light curves and discuss the consequences on possible emission mechanisms.

Fruscione, Antonella↗

TRMM and Its Connection to the Global Water Cycle

The importance of quantitative knowledge of tropical rainfall, its associated latent heating and variability is summarized in the context of the global hydrologic cycle. Much of the tropics is covered by oceans. What land exists, is covered largely by rainforests that are only thinly populated. The only way to adequately measure the global tropical rainfall for climate and general circulation models is from space. The TRMM orbit is inclined 35 degrees leading to good sampling in the tropics and a rapid precession to study the diurnal cycle of precipitation. The precipitation instrument complement consists of the first rain radar to be flown in space (PR), a multi-channel passive microwave sensor (TMI) and a five-channel VIS/IR (VIRS) sensor. The precipitation radar operates at a frequency of 13.6 GHz. The swath width is 220 km, with a horizontal resolution of 4 km and the vertical resolution of 250 m. The minimum detectable signal from the precipitation radar has been measured at 17 dBZ. The TMI instrument is designed similar to the SSM/I with two important changes. The 22.235 GHz water vapor absorption channel of the SSM/I was moved to 21.3 GHz in order to avoid saturation in the tropics and 10.7 GHz V&H polarized channels were added to expand the dynamic range of rainfall estimates. The resolution of the TMI varies from 4.6 km at 85 GHz to 36 km at 10.7 GHz. The visible and infrared sensor (VIRS) measures radiation at 0.63, 1.6, 3.75, 10.8 and 12.0 microns. The spatial resolution of all five VIRS channels is 2 km at nadir. In addition to the three primary rainfall instruments, TRMM will also carry a Lightning Imaging Sensor (LIS) and a Clouds and the Earth's Radiant Energy System (CERES) instrument. This presentation will focus primarily on the advances in our understanding of tropical rain systems needed to interpret the TRMM data. Global averages, as well as case studies from TRMM radar (PR), the TRMM Microwave Imager (TMI) and Visible and Infrared Sensor (VIRS) will be presented. Comparisons and contrasts among the different sensors will be drawn. Results will also be compared to previous rainfall climatologies generated from the SSM/I instrument. In particular this paper will focus on the synergy between the TRMM radar and passive microwave radiometer and what we have learned from is synergy.

Kummerow, Chiristian↗

Backscatter Modeling at 2.1 Micron Wavelength for Space-Based and Airborne Lidars Using Aerosol Physico-Chemical and Lidar Datasets

Space-based and airborne coherent Doppler lidars designed for measuring global tropospheric wind profiles in cloud-free air rely on backscatter, beta from aerosols acting as passive wind tracers. Aerosol beta distribution in the vertical can vary over as much as 5-6 orders of magnitude. Thus, the design of a wave length-specific, space-borne or airborne lidar must account for the magnitude of 8 in the region or features of interest. The SPAce Readiness Coherent Lidar Experiment under development by the National Aeronautics and Space Administration (NASA) and scheduled for launch on the Space Shuttle in 2001, will demonstrate wind measurements from space using a solid-state 2 micrometer coherent Doppler lidar. Consequently, there is a critical need to understand variability of aerosol beta at 2.1 micrometers, to evaluate signal detection under varying aerosol loading conditions. Although few direct measurements of beta at 2.1 micrometers exist, extensive datasets, including climatologies in widely-separated locations, do exist for other wavelengths based on CO2 and Nd:YAG lidars. Datasets also exist for the associated microphysical and chemical properties. An example of a multi-parametric dataset is that of the NASA GLObal Backscatter Experiment (GLOBE) in 1990 in which aerosol chemistry and size distributions were measured concurrently with multi-wavelength lidar backscatter observations. More recently, continuous-wave (CW) lidar backscatter measurements at mid-infrared wavelengths have been made during the Multicenter Airborne Coherent Atmospheric Wind Sensor (MACAWS) experiment in 1995. Using Lorenz-Mie theory, these datasets have been used to develop a method to convert lidar backscatter to the 2.1 micrometer wavelength. This paper presents comparison of modeled backscatter at wavelengths for which backscatter measurements exist including converted beta (sub 2.1).

Srivastava, V.↗

TRMM and Its Connection to the Global Water Cycle

The importance of quantitative knowledge of tropical rainfall, its associated latent heating and variability is summarized in the context of the global hydrologic cycle. Much of the tropics is covered by oceans. What land exists, is covered largely by rainforests that are only thinly populated. The only way to adequately measure the global tropical rainfall for climate and general circulation models is from space. The TRMM orbit is inclined 35' leading to good sampling in the tropics and a rapid precession to study the diurnal cycle of precipitation. The precipitation instrument complement consists of the first rain radar to be flown in space (PR), a multi-channel passive microwave sensor (TMI) and a five-channel VIS/IR (VIRS) sensor. The precipitation radar operates at a frequency of 13.6 GHz. The swath width is 220 km, with a horizontal resolution of 4 km and the vertical resolution of 250 in. The minimum detectable signal from the precipitation radar has been measured at 17 dBZ. The TMI instrument is designed similar to the SSM/I with two important changes. The 22.235 GHz water vapor absorption channel of the SSM/I was moved to 21.3 GHz in order to avoid saturation in the tropics and 10.7 GHz V&H polarized channels were added to expand the dynamic range of rainfall estimates. The resolution of the TMI varies from 4.6 km at 85 GHz to 36 km at 10.7 GHz. The visible and infrared sensor (VIRS) measures radiation at 0.63, 1.6, 3.75, 10.8 and 12.0 microns. The spatial resolution of all five VIRS channels is 2 km at nadir. In addition to the three primary rainfall instruments, TRMM will also carry a Lightning Imaging Sensor (LIS) and a Clouds and the Earth's Radiant Energy System (CERES) instrument.

Kummerow, Christian↗