Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systematics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Systematic study of target localization for bioluminescence tomography guided radiation therapy

Purpose: To overcome the limitation of CT/cone-beam CT (CBCT) in guiding radiation for soft tissue targets, the authors developed a spectrally resolved bioluminescence tomography (BLT) system for the small animal radiation research platform. The authors systematically assessed the performance of the BLT system in terms of target localization and the ability to resolve two neighboring sources in simulations, tissue-mimicking phantom, and in vivo environments. Methods: Multispectral measurements acquired in a single projection were used for the BLT reconstruction. The incomplete variables truncated conjugate gradient algorithm with an iterative permissible region shrinking strategy was employed as the optimization scheme to reconstruct source distributions. Simulation studies were conducted for single spherical sources with sizes from 0.5 to 3 mm radius at depth of 3–12 mm. The same configuration was also applied for the double source simulation with source separations varying from 3 to 9 mm. Experiments were performed in a standalone BLT/CBCT system. Two self-illuminated sources with 3 and 4.7 mm separations placed inside a tissue-mimicking phantom were chosen as the test cases. Live mice implanted with single-source at 6 and 9 mm depth, two sources at 3 and 5 mm separation at depth of 5 mm, or three sources in the abdomen were also used to illustrate the localization capability of the BLT system for multiple targets in vivo. Results: For simulation study, approximate 1 mm accuracy can be achieved at localizing center of mass (CoM) for single-source and grouped CoM for double source cases. For the case of 1.5 mm radius source, a common tumor size used in preclinical study, their simulation shows that for all the source separations considered, except for the 3 mm separation at 9 and 12 mm depth, the two neighboring sources can be resolved at depths from 3 to 12 mm. Phantom experiments illustrated that 2D bioluminescence imaging failed to distinguish two sources, but BLT can provide 3D source localization with approximately 1 mm accuracy. The in vivo results are encouraging that 1 and 1.7 mm accuracy can be attained for the single-source case at 6 and 9 mm depth, respectively. For the 2 sources in vivo study, both sources can be distinguished at 3 and 5 mm separations, and approximately 1 mm localization accuracy can also be achieved. Conclusions: This study demonstrated that their multispectral BLT/CBCT system could be potentially applied to localize and resolve multiple sources at wide range of source sizes, depths, and separations. The average accuracy of localizing CoM for single-source and grouped CoM for double sources is approximately 1 mm except deep-seated target. The information provided in this study can be instructive to devise treatment margins for BLT-guided irradiation. These results also suggest that the 3D BLT system could guide radiation for the situation with multiple targets, such as metastatic tumor models.

60 APPLIED LIFE SCIENCES↗

SU-F-I-77: Radiation Dose in Cardiac Catheterization Procedures: Impact of a Systematic Reduction in Pulsed Fluoroscopy Frame Rate

Purpose: To evaluate whether one small systematic reduction in fluoroscopy frame rate has a significant effect on the total air kerma and/or dose area product for diagnostic and interventional cardiac catheterization procedures. Methods: The default fluoroscopy frame rate (FFR) was lowered from 15 to 10 fps in 5 Siemens™ Axiom Artis cardiac catheterization labs (CCL) on July 1, 2013. A total of 7212 consecutive diagnostic and interventional CCL procedures were divided into two study groups: 3602 procedures from 10/1/12 –6/30/13 with FFR of 15 fps; and 3610 procedures 7/1/13 – 3/31/14 at 10 fps. For each procedure, total air kerma (TAK), fluoroscopy skin dose (FSD), total/fluoroscopy dose area products (TAD, FAD), and total fluoroscopy time (FT) were recorded. Patient specific data collected for each procedure included: BSA, sex, height, weight, interventional versus diagnostic; and elective versus emergent. Results: For pre to post change in FFR, each categorical variable was compared using Pearson’s Chi-square test, Odds ratios and 95% confidence intervals. No statistically significant difference in BSA, height, weight, number of interventional versus diagnostic, elective versus emergent procedures was found between the two study groups. Decreasing the default FFR from 15 fps to 10 fps in the two study groups significantly reduced TAK from 1305 to 1061 mGy (p<0.0001), FSD from 627 to 454 mGy (p<0.0001), TAD from 8681 to 6991 uGy × m{sup 2}(p<0.0001), and FAD from 4493 to 3297 uGy × m{sup 2}(p<0.0001). No statistically significant difference in FT was noted. Clinical image quality was not analyzed, and reports of noticeable effects were minimal. From July 1, 2013 to date, the default FFR has remained 10 fps. Conclusion: Reducing the FFR from 15 to 10 fps significantly reduced total air kerma and dose area product which may decrease risk for potential radiation-induced skin injuries and improve patient outcomes.

60 APPLIED LIFE SCIENCES↗

SU-F-J-206: Systematic Evaluation of the Minimum Detectable Shift Using a Range- Finding Camera

Purpose: The robotic table used for patient alignment in proton therapy is calibrated only at commissioning under well-defined conditions and table shifts may vary over time and with differing conditions. The purpose of this study is to systematically investigate minimum detectable shifts using a time-of-flight (TOF) range-finding camera for table position feedback. Methods: A TOF camera was used to acquire one hundred 424 × 512 range images from a flat surface before and after known shifts. Range was assigned by averaging central regions of the image across multiple images. Depth resolution was determined by evaluating the difference between the actual shift of the surface and the measured shift. Depth resolution was evaluated for number of images averaged, area of sensor over which depth was averaged, distance from camera to surface, central versus peripheral image regions, and angle of surface relative to camera. Results: For one to one thousand images with a shift of one millimeter the range in error was 0.852 ± 0.27 mm to 0.004 ± 0.01 mm (95% C.I.). For varying regions of the camera sensor the range in error was 0.02 ± 0.05 mm to 0.47 ± 0.04 mm. The following results are for 10 image averages. For areas ranging from one pixel to 9 × 9 pixels the range in error was 0.15 ± 0.09 to 0.29 ± 0.15 mm (1σ). For distances ranging from two to four meters the range in error was 0.15 ± 0.09 to 0.28 ± 0.15 mm. For an angle of incidence between thirty degrees and ninety degrees the average range in error was 0.11 ± 0.08 to 0.17 ± 0.09 mm. Conclusion: It is feasible to use a TOF camera for measuring shifts in flat surfaces under clinically relevant conditions with submillimeter precision.

60 APPLIED LIFE SCIENCES↗

WE-FG-BRA-06: Systematic Study of Target Localization for Bioluminescence Tomography Guided Radiation Therapy for Preclinical Research

Purpose: To overcome the limitation of CT/CBCT in guiding radiation for soft tissue targets, we developed a bioluminescence tomography(BLT) system for preclinical radiation research. We systematically assessed the system performance in target localization and the ability of resolving two sources in simulations, phantom and in vivo environments. Methods: Multispectral images acquired in single projection were used for the BLT reconstruction. Simulation studies were conducted for single spherical source radius from 0.5 to 3 mm at depth of 3 to 12 mm. The same configuration was also applied for the double sources simulation with source separations varying from 3 to 9 mm. Experiments were performed in a standalone BLT/CBCT system. Two sources with 3 and 4.7 mm separations placed inside a tissue-mimicking phantom were chosen as the test cases. Live mice implanted with single source at 6 and 9 mm depth, 2 sources with 3 and 5 mm separation at depth of 5 mm or 3 sources in the abdomen were also used to illustrate the in vivo localization capability of the BLT system. Results: Simulation and phantom results illustrate that our BLT can provide 3D source localization with approximately 1 mm accuracy. The in vivo results are encouraging that 1 and 1.7 mm accuracy can be attained for the single source case at 6 and 9 mm depth, respectively. For the 2 sources study, both sources can be distinguished at 3 and 5 mm separations at approximately 1 mm accuracy using 3D BLT but not 2D bioluminescence image. Conclusion: Our BLT/CBCT system can be potentially applied to localize and resolve targets at a wide range of target sizes, depths and separations. The information provided in this study can be instructive to devise margins for BLT-guided irradiation and suggests that the BLT could guide radiation for multiple targets, such as metastasis. Drs. John W. Wong and Iulian I. Iordachita receive royalty payment from a licensing agreement between Xstrahl Ltd and Johns Hopkins University.

60 APPLIED LIFE SCIENCES↗

Serial femtosecond and serial synchrotron crystallography can yield data of equivalent quality: A systematic comparison

For the two proteins myoglobin and fluoroacetate dehalogenase, we present a systematic comparison of crystallographic diffraction data collected by serial femtosecond (SFX) and serial synchrotron crystallography (SSX). To maximize comparability, we used the same batch of micron-sized crystals, the same sample delivery device, and the same data analysis software. Overall figures of merit indicate that the data of both radiation sources are of equivalent quality. For both proteins, reasonable data statistics can be obtained with approximately 5000 room-temperature diffraction images irrespective of the radiation source. The direct comparability of SSX and SFX data indicates that the quality of diffraction data obtained from these samples is linked to the properties of the crystals rather than to the radiation source. Therefore, for other systems with similar properties, time-resolved experiments can be conducted at the radiation source that best matches the desired time resolution.

59 BASIC BIOLOGICAL SCIENCES↗

Systematic modification of functionality in disordered elastic networks through free energy surface tailoring

A combined machine learning–physics–based approach is explored for molecular and materials engineering. Specifically, collective variables, akin to those used in enhanced sampled simulations, are constructed using a machine learning model trained on data gathered from a single system. Through the constructed collective variables, it becomes possible to identify critical molecular interactions in the considered system, the modulation of which enables a systematic tailoring of the system’s free energy landscape. To explore the efficacy of the proposed approach, we use it to engineer allosteric regulation and uniaxial strain fluctuations in a complex disordered elastic network. Its successful application in these two cases provides insights regarding how functionality is governed in systems characterized by extensive connectivity and points to its potential for design of complex molecular systems.

42 ENGINEERING↗

The Fungal Tree of Life: from Molecular Systematics to Genome-Scale Phylogenies

The kingdom Fungi is one of the more diverse clades of eukaryotes in terrestrial ecosystems, where they provide numerous ecological services ranging from decomposition of organic matter and nutrient cycling to beneficial and antagonistic associations with plants and animals. The evolutionary relationships of the kingdom have represented some of the more recalcitrant problems in systematics and phylogenetics. The advent of molecular phylogenetics, and more recently phylogenomics, has greatly advanced our understanding of the patterns and processes associated with fungal evolution, however. In this article, we review the major phyla, subphyla, and classes of the kingdom Fungi and provide brief summaries of ecologies, morphologies, and exemplar taxa. We also provide examples of how molecular phylogenetics and evolutionary genomics have advanced our understanding of fungal evolution within each of the phyla and some of the major classes. In the current classification we recognize 8 phyla, 12 subphyla, and 46 classes within the kingdom. The ancestor of fungi is inferred to be zoosporic, and zoosporic fungi comprise three lineages that are paraphyletic to the remainder of fungi. Fungi historically classified as zygomycetes do not form a monophyletic group and are paraphyletic to Ascomycota and Basidiomycota. Ascomycota and Basidiomycota are each monophyletic and collectively form the subkingdom Dikarya.

Spatafora, Joseph W.↗

Model-independent analysis of Airy structures in the differential cross sections for the elastic scattering of {sup 4}He and {sup 16}O nuclei within a single S-matrix systematics

On the basis of a model-independent S-matrix approach, the differential cross sections for elastic {sup 4}He-{sup 90}Zr, {sup 16}O-{sup 12}C, and {sup 16}O-{sup 16}O scattering at energies of projectile nuclei in the range 13-30 MeV per nucleon are analyzed by using an evolution algorithm. In each of the cases considered in this analysis, the resulting scattering matrix is associated with the same S-matrix systematics and is determined by an absolute value and a nuclear phase, which are smooth and monotonic functions of the orbital angular momentum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematization of the yields of products of photonuclear reactions on enriched-tin targets at the bremsstrahlung-photon endpoint energy of 4.5 GeV

Yields of photonuclear-reaction products formed in targets from separated tin isotopes under the effect of beams of bremsstrahlung photons whose endpoint energy is 4.5 GeV were investigated. The systematization performed on this basis revealed an isoscaling character of the behavior of the production yields for various regions of reaction-product masses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematization of cross sections for the production of residual nuclei on separated tin isotopes in reactions induced by various-energy protons

Cross sections for the production of residual nuclei on the isotopes {sup 112,118,120,124}Sn irradiated with 0.66-, 1.0-, 3.65-, and 8.1-GeV proton beams were investigated. A ten-parameter semiempirical formula was used to systematize the cross sections in question. A comparative analysis of parameter values obtained at different proton energies was performed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy dependence and systematics of level-density parameters in nuclei of mass number in the range of A = 20–60

Existing direct and indirect experimental data on level densities in excited nuclei of mass and charge number in the ranges of A = 20–60 and Z = 11–27, respectively, were compiled and analyzed. Contradictions between values extracted from the results of measurements performed by different methods were revealed. Consistent input data were selected, and a systematics of level-density parameters was created on this basis within the generalized model of superfluid nuclei. The effect of the first discrete vibrational levels on extracted parameters was studied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematics of ground state multiplets of atomic nuclei in the delta-interaction approach

Pairing forces between nucleons in an atomic nucleus strongly influence its structure. One of the manifestations of pair interaction is the ground state multiplet (GSM) formation in the spectrum of low-lying excited states of even–even nuclei. The value of GSM splitting is determined by the value of pair interaction of nucleons; for each isotope, it can be estimated on the basis of experimental nuclear masses. The quality of this estimate is characterized by the degree of reproduction of GSM levels in the nucleus. The GSM systematics in even–even nuclei with a pair of identical nucleons in addition to the filled nuclear core is considered on the basis of delta interaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematic comparison of barriers for heavy-ion fusion calculated on the basis of the double-folding model by employing two versions of nucleon–nucleon interaction

A systematic calculation of barriers for heavy-ion fusion was performed on the basis of the double-folding model by employing two versions of an effective nucleon–nucleon interaction: M3Y interaction and Migdal interaction. The results of calculations by the Hartree–Fockmethod with the SKX coefficients were taken for nuclear densities. The calculations reveal that the fusion barrier is higher in the case of employing theMigdal interaction than in the case of employing the М3Y interaction. In view of this, the use of the Migdal interaction in describing heavy-ion fusion is questionable.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sources of the systematic errors in measurements of {sup 214}Po decay half-life time variations at the Baksan deep underground experiments

The design changes of the Baksan low-background TAU-1 and TAU-2 set-ups allowed to improve a sensitivity of {sup 214}Po half-life (τ) measurements up to the 2.5 × 10{sup −4} are described. Different possible sources of systematic errors influencing on the τ-value are studied. An annual variation of {sup 214}Po half-life time measurements with an amplitude of A = (6.9 ± 3) × 10{sup −4} and a phase of φ = 93 ± 10 days was found in a sequence of the week-collected τ-values obtained from the TAU-2 data sample with total duration of 480 days. 24 hours’ variation of the t-value measurements with an amplitude of A = (10.0 ± 2.6) × 10{sup −4} and phase of φ = 1 ± 0.5 hours was found in a solar day 1 hour step t-value sequence formed from the same data sample. It was found that the {sup 214}Po half-life averaged at 480 days is equal to 163.45 ± 0.04 μs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of systematic uncertainty-aware neural network trainings for binned-likelihood analyses at the LHC

We propose a neural network training method capable of accounting for the effects of systematic variations of the data model in the training process and describe its extension towards neural network multiclass classification. The procedure is evaluated on the realistic case of the measurement of Higgs boson production via gluon fusion and vector boson fusion in the τ τ decay channel at the CMS experiment. The neural network output functions are used to infer the signal strengths for inclusive production of Higgs bosons as well as for their production via gluon fusion and vector boson fusion. We observe improvements of 12 and 16% in the uncertainty in the signal strengths for gluon and vector-boson fusion, respectively, compared with a conventional neural network training based on cross-entropy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Systematics of the chemical freeze-out line in the high baryon density regime explored at SIS100

The systematic uncertainties of chemical freeze-out fits at SIS100 energies (Au+Au reactions at $\sqrt{s_{NN}}$ = 3 – 5 GeV) are studied using UrQMD simulations. Although hadron production in UrQMD does not occur on a sharp chemical freeze-out hyper-surface, the extracted fit quality is shown to be very good. The extracted chemical parameters depend on the selected hadron species as well as the underlying equation of state (EoS) of the matter. Including light nuclei and anti-protons in the fit increases the expected freeze-out temperature, while a stiffer EoS increases the obtained chemical potential. Similarly, the baryon densities extracted by the thermal fits depend on the choice of hadrons as well as the underlying equation of state. These results are important for the upcoming CBM@FAIR physics program and highlight that a degree of caution is advised when one relates the chemical freeze-out curve to features on the QCD phase diagram like the critical endpoint or a possible phase transition.

Hofmann, Emma Lilith [GSI Helmholtzzentrum für Sch↗

Systematic investigation of the particle spectra in heavy-ion collisions at the Large Hadron Collider

We investigate the charged particle spectra produced in the heavy-ion collisions at nine centralities from different systems, i.e. Pb+Pb at √ s NN = 2.76 TeV and 5.02 TeV as well as Xe+Xe at √ s NN = 5.44 TeV, at Large Hadron Collider (LHC) using one empirical formula inspired by the stationary solution of the Fokker-Planck equation, dubbed as the generalized Fokker-Planck solution (GFPS). Our results show that the GFPS can reproduce the experimental particle spectrum up to transverse momentum pT about 45 GeV/c with the maximum discrepancy 30% covering 10 orders of magnitude. Here, the discrepancy between the data and the results from the GFPS decreases to 15% when the maximum of the charged particle transverse momentum is cut to 20 GeV/c. We confirmed that the Tsallis distribution derived from the non-extensive statistics, which can reproduce the particle spectra produced in small collision systems, such as p+p, up to few hundreds GeV/c, can only apply to systematically study the particle spectra up to 8 GeV/c in A+A collisions at LHC, as pointed out in the study of identified particle spectra in Pb+Pb collisions at √ s NN = 2.76 TeV. A brief discussion on GFPS is also given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗