Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Thermal Infrared Detectors: expanding performance limits using ultrafast electron microscopy

This project aimed to identify the performance-limiting mechanisms in mid- to far infrared (IR) sensors by probing photogenerated free carrier dynamics in model detector materials using scanning ultrafast electron microscopy (SUEM). SUEM is a recently developed method based on using ultrafast electron pulses in combination with optical excitations in a pump- probe configuration to examine charge dynamics with high spatial and temporal resolution and without the need for microfabrication. Five material systems were examined using SUEM in this project: polycrystalline lead zirconium titanate (a pyroelectric), polycrystalline vanadium dioxide (a bolometric material), GaAs (near IR), InAs (mid IR), and Si/SiO 2 system as a prototypical system for interface charge dynamics. The report provides detailed results for the Si/SiO 2 and the lead zirconium titanate systems.

36 MATERIALS SCIENCE↗

Plasma membrane characterization, by scanning electron microscopy, of multipotent myoblasts-derived populations sorted using dielectrophoresis

Highlights: •Dielectrophoretic separation/sorting of multipotent cells. •Plasma membrane microvilli structure of C2C12 and fibroblasts by SEM microscopy. •Cell cycle determination by Ki-67 in DEP-sorted cells. •Plasma membrane differences responsible for changes in membrane capacitance. -- Abstract: Multipotent progenitor cells have shown promise for use in biomedical applications and regenerative medicine. The implementation of such cells for clinical application requires a synchronized, phenotypically and/or genotypically, homogenous cell population. Here we have demonstrated the implementation of a biological tag-free dielectrophoretic device used for discrimination of multipotent myoblastic C2C12 model. The multipotent capabilities in differentiation, for these cells, diminishes with higher passage number, so for cultures above 70 passages only a small percentage of cells is able to differentiate into terminal myotubes. In this work we demonstrated that we could recover, above 96% purity, specific cell types from a mixed population of cells at high passage number without any biological tag using dielectrophoresis. The purity of the samples was confirmed by cytometric analysis using the cell specific marker embryonic myosin. To further investigate the dielectric properties of the cell plasma membrane we co-culture C2C12 with similar size, when in suspension, GFP-positive fibroblast as feeder layer. The level of separation between the cell types was above 98% purity which was confirmed by flow cytometry. These levels of separation are assumed to account for cell size and for the plasma membrane morphological differences between C2C12 and fibroblast unrelated to the stages of the cell cycle which was assessed by immunofluorescence staining. Plasma membrane conformational differences were further confirmed by scanning electron microscopy.

60 APPLIED LIFE SCIENCES↗

Multi-Task Learning of Scanning Electron Microscopy and Synthetic Thermal Tomography Images for Detection of Defects in Additively Manufactured Metals

One of the key challenges in laser powder bed fusion (LPBF) additive manufacturing of metals is the appearance of microscopic pores in 3D-printed metallic structures. Quality control in LPBF can be accomplished with non-destructive imaging of the actual 3D-printed structures. Thermal tomography (TT) is a promising non-contact, non-destructive imaging method, which allows for the visualization of subsurface defects in arbitrary-sized metallic structures. However, because imaging is based on heat diffusion, TT images suffer from blurring, which increases with depth. We have been investigating the enhancement of TT imaging capability using machine learning. In this work, we introduce a novel multi-task learning (MTL) approach, which simultaneously performs the classification of synthetic TT images, and segmentation of experimental scanning electron microscopy (SEM) images. Synthetic TT images are obtained from computer simulations of metallic structures with subsurface elliptical-shaped defects, while experimental SEM images are obtained from imaging of LPBF-printed stainless-steel coupons. MTL network is implemented as a shared U-net encoder between the classification and the segmentation tasks. Results of this study show that the MTL network performs better in both the classification of synthetic TT images and the segmentation of SEM images tasks, as compared to the conventional approach when the individual tasks are performed independently of each other.

36 MATERIALS SCIENCE↗

Electron microscopy and in vitro deneddylation reveal similar architectures and biochemistry of isolated human and Flag-mouse COP9 signalosome complexes

Highlights: • Deneddylation rates of human erythrocyte and mouse fibroblast CSN are very similar. • 3D models of native human and mouse CSN reveal common architectures. • The cryo-structure of native mammalian CSN shows a horseshoe subunit arrangement. - Abstract: The COP9 signalosome (CSN) is a regulator of the ubiquitin (Ub) proteasome system (UPS). In the UPS, proteins are Ub-labeled for degradation by Ub ligases conferring substrate specificity. The CSN controls a large family of Ub ligases called cullin-RING ligases (CRLs), which ubiquitinate cell cycle regulators, transcription factors and DNA damage response proteins. The CSN possesses structural similarities with the 26S proteasome Lid complex and the translation initiation complex 3 (eIF3) indicating similar ancestry and function. Initial structures were obtained 14 years ago by 2D electron microscopy (EM). Recently, first 3D molecular models of the CSN were created on the basis of negative-stain EM and single-particle analysis, mostly with recombinant complexes. Here, we compare deneddylating activity and structural features of CSN complexes purified in an elaborate procedure from human erythrocytes and efficiently pulled down from mouse Flag-CSN2 B8 fibroblasts. In an in vitro deneddylation assay both the human and the mouse CSN complexes deneddylated Nedd8-Cul1 with comparable rates. 3D structural models of the erythrocyte CSN as well as of the mouse Flag-CSN were generated by negative stain EM and by cryo-EM. Both complexes show a central U-shaped segment from which several arms emanate. This structure, called the horseshoe, is formed by the PCI domain subunits. CSN5 and CSN6 point away from the horseshoe. Compared to 3D models of negatively stained CSN complexes, densities assigned to CSN2 and CSN4 are better defined in the cryo-map. Because biochemical and structural results obtained with CSN complexes isolated from human erythrocytes and purified by Flag-CSN pulldown from mouse B8 fibroblasts are very similar, Flag-CSN pulldowns are a proper alternative to CSN preparation from erythrocytes.

60 APPLIED LIFE SCIENCES↗

Development of a testing method for asbestos fibers in treated materials of asbestos containing wastes by transmission electron microscopy

Highlights: • A high sensitive and selective testing method for asbestos in treated materials of asbestos containing wastes was developed. • Asbestos can be determined at a limits are a few million fibers per gram and a few μg g{sup −1}. • High temperature melting treatment samples were determined by this method. Asbestos fiber concentration were below the quantitation limit in all samples, and total fiber concentrations were determined as 47–170 × 10{sup 6} g{sup −1}. - Abstract: Appropriate treatment of asbestos-containing wastes is a significant problem. In Japan, the inertization of asbestos-containing wastes based on new treatment processes approved by the Minister of the Environment is promoted. A highly sensitive method for testing asbestos fibers in inertized materials is required so that these processes can be approved. We developed a method in which fibers from milled treated materials are extracted in water by shaking, and are counted and identified by transmission electron microscopy. Evaluation of this method by using asbestos standards and simulated slag samples confirmed that the quantitation limits are a few million fibers per gram and a few μg/g in a sample of 50 mg per filter. We used this method to assay asbestos fibers in slag samples produced by high-temperature melting of asbestos-containing wastes. Fiber concentrations were below the quantitation limit in all samples, and total fiber concentrations were determined as 47–170 × 10{sup −6} f/g. Because the evaluation of treated materials by TEM is difficult owing to the limited amount of sample observable, this testing method should be used in conjunction with bulk analytical methods for sure evaluation of treated materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Probing the Degradation Mechanisms in Electrolyte Solutions for Li-ion Batteries by In-Situ Transmission Electron Microscopy

One of the goals in the development of new battery technologies is to find new electrolytes with increased electrochemical stability. In-situ (scanning) transmission electron microscopy ((S)TEM) using an electrochemical fluid cell provides the ability to rapidly and directly characterize electrode/electrolyte interfacial reactions under battery relevant electrochemical conditions. Furthermore, as the electron beam itself causes a localized electrochemical reaction when it interacts with the electrolyte, the breakdown products that occur during the first stages of battery operation can potentially be simulated and characterized using a straightforward in-situ liquid stage (without electrochemical biasing capabilities). In this paper, we have studied the breakdown of a range of inorganic/salt complexes that are used in state-of-the-art Li-ion battery systems. The results of the in-situ (S)TEM experiments matches with previous stability tests performed during battery operation and the breakdown products and mechanisms are also consistent with known mechanisms. This analysis indicates that in-situ liquid stage (S)TEM observations can be used to directly test new electrolyte designs and provide structural insights into the origin of the solid electrolyte interphase (SEI) formation mechanism.

25 ENERGY STORAGE↗

The Reactivity and Structural Dynamics of Supported Metal Nanoclusters Using Electron Microscopy, in-situ X-Ray Spectroscopy, Electronic Structure Theories, and Molecular Dynamics Simulations

This research will provide new methods to determine the structures and compositions of heterogeneous catalysts as they exist in reaction conditions. The new tools will make it possible to understand how extremely small material structures—ones in a size range spanning from single atoms to larger polyatomic clusters—make it possible to carry out highly selective chemical transformations required to synthesize useful materials as well as for efficient energy production and utilization. The tools will make it possible to see how the atomic structures of catalytic materials evolve over time under the conditions of their use, and in this way provide understandings to guide the design of new energy-efficient catalysts. The work will make it possible to answer long standing questions that include the following. How does catalyst structure help guide molecules along specific reaction pathways? What are the important intermediates involved in these transformations? How do the structures and reactivity of catalytic materials, as well as the chemistry of their interfaces, vary with reaction conditions? Is it possible to develop new catalytic materials using new knowledge of the active structures and reaction mechanisms? The work will provide heretofore unavailable experimental tools that can be applied in advanced programs of research addressing such questions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A robust synthetic data generation framework for machine learning in high-resolution transmission electron microscopy (HRTEM)

Machine learning techniques are attractive options for developing highly-accurate analysis tools for nanomaterials characterization, including high-resolution transmission electron microscopy (HRTEM). However, successfully implementing such machine learning tools can be difficult due to the challenges in procuring sufficiently large, high-quality training datasets from experiments. In this work, we introduce Construction Zone, a Python package for rapid generation of complex nanoscale atomic structures which enables fast, systematic sampling of realistic nanomaterial structures and can be used as a random structure generator for large, diverse synthetic datasets. Using Construction Zone, we develop an end-to-end machine learning workflow for training neural network models to analyze experimental atomic resolution HRTEM images on the task of nanoparticle image segmentation purely with simulated databases. Further, we study the data curation process to understand how various aspects of the curated simulated data—including simulation fidelity, the distribution of atomic structures, and the distribution of imaging conditions—affect model performance across three benchmark experimental HRTEM image datasets. Using our workflow, we are able to achieve state-of-the-art segmentation performance on these experimental benchmarks and, further, we discuss robust strategies for consistently achieving high performance with machine learning in experimental settings using purely synthetic data. Construction Zone and its documentation are available at https://github.com/lerandc/construction_zone.

36 MATERIALS SCIENCE↗

Probing ferroelectric domain structures and their switching dynamics in SrBi2Ta2O9 by in-situ electric biasing in transmission electron microscopy

Abstract Lead-free SrBi 2 Ta 2 O 9 (SBT) has been a promising ferroelectric material for various applications such as electronics and data storage due to its outstanding ferroelectric properties including high fatigue endurance and low leakage current. However, the atomic-scale domain structure and switching dynamics of ferroelectric SBT remain elusive. This study reveals that spontaneous polarization arises from canted bismuth-cation displacements, forming 90° and Ising-type 180° domain walls. Interestingly, topological pairs of ferroelectric vortex and antivortex connect ferroelectric boundaries where three domain walls converge. In situ electrical biasing transmission electron microscopy (TEM) reveals the dominance of 180° switching over 90°, where oxygen octahedral connectivity is protected by ferroelastic energy in the 90° domain wall. Consequently, all 180° domain walls and (anti)vortices are removed, leaving only 90° domain walls in the electrically poled states. Chemical deterioration along domain walls highlights vulnerability of SBT to ferroelectric fatigue. This study provides insight into crucial aspects for practical applications of SBT.

36 MATERIALS SCIENCE↗

In situ transmission electron microscopy study on the epitaxial growth of CoSi2 on Si(111) at temperatures below 150 C

This paper reports an in situ transmission electron microscopy study on the epitaxial growth of CoSi2 on Si(111) from a 10-nm-thick amorphous mixture of Co and Si in the ratio 1:2, which was formed by codeposition of Co and Si near room temperature. Nuclei of CoSi2 are observed in the as-deposited film. These nuclei are epitaxial and extend through the whole film thickness. Upon annealing, these columnar epitaxial CoSi2 grains grow laterally at temperatures as low as 50 C. The kinetics of this lateral epitaxial growth was studied at temperatures between 50 and 150 C. The activation energy of the growth process is 0.8 + or - 0.1 eV.

Nieh, C. W.↗

High-Resolution Transmission Electron Microscopy Observation of Colloidal Nanocrystal Growth Mechanisms using Graphene Liquid Cells

We introduce a new type of liquid cell for in-situ electron microscopy based upon entrapment of a liquid film between layers of graphene. We employ this cell to achieve high-resolution imaging of colloidal platinum nanocrystal growth. The ability to directly image and resolve critical steps at atomic resolution provides new insights into nanocrystal coalescence and reshaping during growth.

14 SOLAR ENERGY↗

Determination of the oxide scale growth mechanism using 18O-tracer experiments in combination with Transmission Electron Microscopy and nanoscale Secondary Ion Mass Spectrometry

Highlights: • {sup 18}O-tracer experiments to determine oxide scale growth mechanism on a Fe-Cr alloy. • Cr{sub 2}O{sub 3} scale growth primarily by means of metal outwards diffusion in air at 850 °C • nanoSIMS mapping on TEM lamella more accurate than SIMS sputter depth profiling • nanoSIMS mapping on TEM lamella reveal information about local oxide growth. • Strong local variation of oxide scale growth - Abstract: Two-stage {sup 18}O{sub 2}/{sup 16}O{sub 2} exposures can be used to investigate the effect that alloying elements, secondary phases, or surface treatments have on the high temperature oxidation behaviour of certain materials. During subsequent exposures to {sup 16}O{sub 2}- and {sup 18}O{sub 2}-rich atmospheres, {sup 16}O- and {sup 18}O-rich layers are formed. Analysis of the layers using Secondary Ion Mass Spectrometry (SIMS) depth profiling allows for conclusions to be drawn about the oxide scale growth mechanism. The conclusions are, however, not entirely unambiguous due to the limited lateral resolution of the technology. Rough surface topography and the thickness variation of the oxide scale over the analysed volume add to the ambiguity of the findings. In this study, an Fe-20%Cr alloy was exposed to both {sup 18}O- and {sup 16}O-rich environments at 850 °C. Two methods were used to analyse the thermally grown Cr{sub 2}O{sub 3} scale: (1) traditional SIMS depth profiling and (2) preparation of a cross-sectional lamellae for Transmission Electron Microscopy (TEM), which, subsequently, was analysed in a NanoSIMS. The NanoSIMS {sup 16}O and {sup 18}O elemental maps were then superimposed on the TEM image. In comparison with traditional SIMS depth profiling, the nanoSIMS elemental maps reveal detailed information about local oxide growth in different parts of an oxide scale. Moreover, a clear {sup 16}O/{sup 18}O interface can be seen in the nanoSIMS maps, which is not the case in the sputter depth profiles. The findings of this study show that the aforementioned issues associated with sputter depth profiling can be eliminated by mapping a cross-section of an oxide scale using high resolution nanoSIMS.

36 MATERIALS SCIENCE↗