Search NASA⌕ Search

SEARCH · Search NASA

Results for “focal plane array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Fabrication of large dual-polarized multichroic TES bolometer arrays for CMB measurements with the SPT-3G camera

This paper presents the procedures used by Argonne National Laboratory to fabricate large arrays of multichroic transition-edge sensor (TES) bolometers for cosmic microwave background (CMB) measurements. These detectors will be assembled into the focal plane for the SPT-3G camera, the third generation CMB camera to be installed in the South Pole Telescope. The complete SPT-3G camera will have approximately 2690 pixels, for a total of 16,140 TES bolometric detectors. Each pixel is comprised of a broad-band sinuous antenna coupled to a Nb microstrip line. In-line filters are used to define the different band-passes before the millimeter-wavelength signal is fed to the respective Ti/Au TES bolometers. There are six TES bolometer detectors per pixel, which allow for measurements of three band-passes (95 GHz, 150 GHz and 220 GHz) and two polarizations. The steps involved in the monolithic fabrication of these detector arrays are presented here in detail. Patterns are defined using a combination of stepper and contact lithography. The misalignment between layers is kept below 200 nm. The overall fabrication involves a total of 16 processes, including reactive and magnetron sputtering, reactive ion etching, inductively coupled plasma etching and chemical etching.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal IR imaging system using a self-scanned HgCdTe/CCD detector array

It is likely that future high resolution earth observation imaging systems will utilize self-scanned IR detectors. In an initial step toward this goal, an IR imaging system operating in the 10 to 12 micron spectral region has been developed. This system uses a 9-element HgCdTe/CCD linear array operating in the photoconductive mode, nine pre-amplifiers and a silicon CCD multiplexer integrated into a focal plane assembly. Opto-mechanical techniques are used to scan the scene and images are produced in real time. The imaging performance of this system is described and measurements of noise, responsivity, specific detectivity, and detector sensitivity profiles are presented. The requirements for more advanced detector arrays for use in future NASA remote sensing missions are also discussed.

Husain-Abidi, A. S.↗

Cooled echelle grating spectrometer

A cooled echelle grating spectrometer for detecting wavelengths between one micron and fifteen microns is disclosed. More specifically, the spectrometer has a cross-dispersing grating for ordering infrared energy and an echelle grating for further ordering of the infrared energy. Ordered radiation from the echelle grating is sensed by a detecting means. Also disclosed is use of a Schmidt camera for focusing the further ordered radiation from the echelle grating onto a detector array having individual detectors dispersed on a plane which substantially corresponds to a curved focal plane of the Schmidt camera. A spectrometer constructed according to the teachings of the present invention will continuously cover the spectrum between one micron and fifteen microns and have a resolution of 0.1/cm.

Beer, R.↗

Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector

Purpose: The goal of this study is to evaluate a new method based on a coded aperture mask combined with a digital x-ray imaging detector for measurements of the focal spot sizes of diagnostic x-ray tubes. Common techniques for focal spot size measurements employ a pinhole camera, a slit camera, or a star resolution pattern. The coded aperture mask is a radiation collimator consisting of a large number of apertures disposed on a predetermined grid in an array, through which the radiation source is imaged onto a digital x-ray detector. The method of the coded mask camera allows one to obtain a one-shot accurate and direct measurement of the two dimensions of the focal spot (like that for a pinhole camera) but at a low tube loading (like that for a slit camera). A large number of small apertures in the coded mask operate as a ''multipinhole'' with greater efficiency than a single pinhole, but keeping the resolution of a single pinhole. Methods: X-ray images result from the multiplexed output on the detector image plane of such a multiple aperture array, and the image of the source is digitally reconstructed with a deconvolution algorithm. Images of the focal spot of a laboratory x-ray tube (W anode: 35-80 kVp; focal spot size of 0.04 mm) were acquired at different geometrical magnifications with two different types of digital detector (a photon counting hybrid silicon pixel detector with 0.055 mm pitch and a flat panel CMOS digital detector with 0.05 mm pitch) using a high resolution coded mask (type no-two-holes-touching modified uniformly redundant array) with 480 0.07 mm apertures, designed for imaging at energies below 35 keV. Measurements with a slit camera were performed for comparison. A test with a pinhole camera and with the coded mask on a computed radiography mammography unit with 0.3 mm focal spot was also carried out. Results: The full width at half maximum focal spot sizes were obtained from the line profiles of the decoded images, showing a focal spot of 0.120 mmx0.105 mm at 35 kVp and M=6.1, with a detector entrance exposure as low as 1.82 mR (0.125 mA s tube load). The slit camera indicated a focal spot of 0.112 mmx0.104 mm at 35 kVp and M=3.15, with an exposure at the detector of 72 mR. Focal spot measurements with the coded mask could be performed up to 80 kVp. Tolerance to angular misalignment with the reference beam up to 7 deg. in in-plane rotations and 1 deg. deg in out-of-plane rotations was observed. The axial distance of the focal spot from the coded mask could also be determined. It is possible to determine the beam intensity via measurement of the intensity of the decoded image of the focal spot and via a calibration procedure. Conclusions: Coded aperture masks coupled to a digital area detector produce precise determinations of the focal spot of an x-ray tube with reduced tube loading and measurement time, coupled to a large tolerance in the alignment of the mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Event Reconstruction Method for the Telescope Array Fluorescence Detectors

We measure arrival directions, energies and mass composition of ultra-high energy cosmic rays with air fluorescence detector telescopes. The longitudinal profile of the cosmic ray induced extensive air shower cascade is imaged on focal plane of the telescope camera. Here, we show an event reconstruction method to obtain the primary information from data collected by the Telescope Array Fluorescence Detectors. In particular, we report on an ''Inverse Monte Carlo (IMC)'' method in which the reconstruction process searches for an optimum solution via repeated Monte Carlo simulations including characteristics of all detectors, atmospheric conditions, photon emission and scattering processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results and Limits of Time-Division Multiplexing for the BICEP Array High-Frequency Receivers

Time-division multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high-frequency receivers, observing at 150 GHz and 220/270 GHz, will have 7776 TES detectors tiled on the focal plane. The constraints set by these two receivers required a redesign of the warm readout electronics. The new version of the standard multichannel electronics, developed and built at the University of British Columbia, is presented here for the first time. BICEP Array operates time-division multiplexing readout technology to the limits of its capabilities in terms of multiplexing rate, noise and cross talk, and applies them in rigorously demanding scientific application requiring extreme noise performance and systematic error control. Finally, future experiments like CMB-S4 plan to use TES bolometers with time-division/SQUID-based readout for an even larger number of detectors.

47 OTHER INSTRUMENTATION↗

The ASTRO-H Mission

The joint JAXA/NASA Astro-H mission is the sixth in a series of X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). The planned launch date is 2014. Astro-H will investigate the physics of the high-energy universe by performing high-resolution, high-throughput spectroscopy with moderate spatial resolution over the 0.3-600 keV energy range. ASTRO-H is a combination of wide band X-ray spectroscopy (3-80 keV) provided by focusing hard X-ray mirrors and hard X-ray imaging detectors, and high energy-resolution soft X-ray spectroscopy (0.3-10 keV) provided by thin-foil X-ray optics and a micro-calorimeter array. The mission will also carry an X-ray CCD camera as a focal plane detector for a soft X-ray telescope and a non-focusing soft gamma-ray detector. The simultaneous broad bandpass, coupled with high spectral resolution of {Delta}E{approx}7 eV by the micro-calorimeter will enable a wide variety of important science themes to be pursued.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging spectrometer concepts for next-generation planetary missions

In recent years there has been an increasing interest in the imaging spectrometer concept, in which imaging is accomplished in multiple, contiguous spectral bands at typical intervals of 5 to 20 nm. There are two implementations of this concept under consideration for upcoming planetary missions. One is the scanning, or 'whisk-broom' approach, in which each picture element (pixel) of the scene is spectrally dispersed onto a linear array of detectors; the spatial information is provided by a scan mirror in combination with the vehicle motion. The second approach is the 'push-broom' imager, in which a line of pixels from the scene is spectrally dispersed onto a two-dimensional (area-array) detector. In this approach, the scan mirror is eliminated, but the optics and focal plane are more complex. This paper discusses the application of these emerging instrument concepts to the planetary program. Key issues are the trade-off between the two types of imaging spectrometer, the available data rate from a typical planetary mission, and the focal-plane cooling requirements. Specific straw-man conceptual designs for the Mars Geoscience/Climatology Orbiter (MGCO) and the Mariner Mark II Comet Rendezvous/Asteroid Flyby (CRAF) missions are discussed.

Herring, M.↗

Experimental code verification results for reflector antenna distortion compensation by array feeds

Electronic compensation of reflector surface distortion using array feed with individual amplitude and phase control of the array elements is becoming increasingly attractive because of the recent advances in monolithic microwave integrated circuit (MMIC) technology. An algorithm has been developed previously using the concept of focal plane conjugate field matching in the receive mode and a computer code has been generated that predicts the proper excitation coefficients for the elements of the reflector feed array to compensate the effects of reflector surface distortion. This paper presents the results of an experimental study to verify the above compensation algorithm and in general to demonstrate the effectiveness of the array feed compensation technique.

Zaman, A. J.↗

Development in High-Density Cobra Fiber Positioners for the Subaru Telescope's Prime Focus Spectrometer

The Prime Focus Spectrograph (PFS) is a fiber fed multi-object spectrometer for the Subaru Telescope that will conduct a variety of targeted surveys for studies of dark energy, galaxy evolution, and galactic archaeology. The key to the instrument is a high density array of fiber positioners placed at the prime focus of the Subaru Telescope. The system, nicknamed "Cobra", will be capable of rapidly reconfiguring the array of 2394 optical fibers to the image positions of astronomical targets in the focal plane with high accuracy. The system uses 2394 individual "SCARA robot" mechanisms that are 7.7mm in diameter and use 2 piezo-electric rotary motors to individually position each of the optical fibers within its patrol region. Testing demonstrates that the Cobra positioner can be moved to within 5 micrometers of an astronomical target in 6 move iterations with a success rate of 95%. The Cobra system is a key aspect of PFS that will enable its unprecedented combination of high-multiplex factor and observing efficiency on the Subaru telescope. The requirements, design, and prototyping efforts for the fiber positioner system for the PFS are described here as are the plans for modular construction, assembly, integration, functional testing, and performance validation.

Cobra↗

High Energy Replicated Optics to Explore the Sun: Hard X-Ray Balloon-Borne Telescope

Set to fly in the Fall of 2013 from Ft. Sumner, NM, the High Energy Replicated Optics to Explore the Sun (HEROES) mission is a collaborative effort between the NASA Marshall Space Flight Center and the Goddard Space Flight Center to upgrade an existing payload, the High Energy Replicated Optics (HERO) balloon-borne telescope, to make unique scientific measurements of the Sun and astrophysical targets during the same flight. The HEROES science payload consists of 8 mirror modules, housing a total of 109 grazing-incidence optics. These modules are mounted on a carbon-fiber - and Aluminum optical bench 6 m from a matching array of high pressure xenon gas scintillation proportional counters, which serve as the focal-plane detectors. The HERO gondola utilizes a differential GPS system (backed by a magnetometer) for coarse pointing in the azimuth and a shaft angle encoder plus inclinometer provides the coarse elevation. The HEROES payload will incorporate a new solar aspect system to supplement the existing star camera, for fine pointing during both the day and night. A mechanical shutter will be added to the star camera to protect it during solar observations. HEROES will also implement two novel alignment monitoring system that will measure the alignment between the optical bench and the star camera and between the optics and detectors for improved pointing and post-flight data reconstruction. The overall payload will also be discussed. This mission is funded by the NASA HOPE (Hands On Project Experience) Training Opportunity awarded by the NASA Academy of Program/Project and Engineering Leadership, in partnership with NASA's Science Mission Directorate, Office of the Chief Engineer and Office of the Chief Technologist

Gaskin, Jessica↗

A radiation-hard, low-background multiplexer design for spacecraft imager applications

A possible multiplexer design for the focal plane for the Cassini Visible and Infrared Mapping Spectrometer (VIMS) is reviewed. The instrument's requirements for the multiplexed array are summarized. The VIMS instrument has a modest radiation-hardness requirement due to the trajectory and planetary environments in which the instrument will be required to operate. The total ionizing dose hardness requirement is a few tens of kilorads. A thin-gate oxide of a few hundred angstroms thickness is to be used. Field hardness is to be achieved by guard bands or hardened dielectric isolation. The design is argued to meet the low-noise and radiation-hardness required for imaging at Saturn. The design is versatile enough to provide double-correlated and double-uncorrelated sampling, which is accomplished in the signal processing electronics outside the focal plane.

Staller, Craig↗

Pixelated scintillator array response to relativistic electrons

In order to make time resolved measurements of the gamma spectra on DARHT Axis 2 using the Compton Spectrometer (CS), the electron detector in the focal plane must be a scintillator that is optically coupled to a gated or streak camera. There are several issues we would like to address with experiments at Idaho Accelerator Center (IAC) before committing to a full size array (7”x2”), which would cost at least $100k. Two candidates for this application are organic (Bicron 422 or equivalent) or inorganic (LYSO) scintillator. Monte Carlo calculations were performed by Rachel Morneau, P-21, using MCNP to compare the two materials each 1.5mm thick for an energy range of 0.1 to 20MeV. The energy loss per particle in LYSO is much larger (100x) than in the plastic scintillator. We confirmed, by performing experiments with the CS on the Microton, that sensitivity of the LYSO was much larger (10x) than the plastic scintillator. Therefore, we have selected LYSO as the scintillator of choice. However, interest in the response of other organic and plastic scintillators prompted an increase in scope of the project. The goals of this experiment were as follows. First, we need to understand the optical response of the scintillators to electrons as a function of thickness, energy, and deposited charge. We also need to verify level of saturation in the scintillation process. Second, compare the scintillators’ response to an image plate (the current CS detector). Third, we need to quantify the effect of signal bleed through to adjacent pixels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard X-Ray Telescope (HXT) with Simultaneous Multiwavelength Observing from UV to 1 MeV

The scientific instrumentation associated with this study includes three coaligned telescope systems: an array of grazing incidence telescopes with graded d-spacing multilayers to enhance reflectivity above 10 keV and a compound detector in their focal planes that covers the 0.1 to 100 keV band; a single laue crystal telescope that concentrates selected narrow regions in the 150 to 1300 keV bands containing interesting lines onto a cooled segmented high energy resolution germanium detector; and an array of three small UV telescopes with detectors and filters to isolate various bands in the 1000 to 2500 A region. The principal objectives of the study is to define what technology developments are required for these instruments to be built, refine the specifications of each instrument component, and identify what type of mission is needed for an HXT observatory. One key question is whether this set of instruments should be located together as an ensemble observing simultaneously aboard a single dedicated mission or distributed among multiple missions with other instrumentation.

Goenstein, Paul↗

Infrared technology XVII; Proceedings of the Meeting, San Diego, CA, July 22-26, 1991

Recent advances in IR technologies and their application to all types of IR systems are reported focusing on the JPL Space Infrared Telescope Facility (SIRTF), JPL instruments and systems for observation of earth and the atmosphere, staring arrays and thermal imaging, ten-year updates of IR techniques, infrared in the USSR, simulation and testing, focal-plane and optical technologies, and military and scientific applications. Particular attention is given to SIRTF stray light analysis, SIRTF focal-plane technologies, long-wave IR detectors based on III-V materials, IR lidars for atmospheric remote sensing, a firefly system concept, a high-fill-factor monolithic IR image sensor, atmospheric laser-transmission tables simply generated, ORION semiconductor optical detectors, postprocessing of thermograms in IR nondestructive testing, evaluation of the IR signature of dynamic air targets, the current status of InGaAs detector arrays for 1-3 microns, a dual-band optical system for IR multicolor signal processing, and blackbody radiators for field calibration.

Andresen, Bjorn F.↗

Production of microchannel plates using nano-scale additive manufacturing

Microchannel plate (MCP) detectors have been the workhorse detector for many applications, including space borne ultra-violet imaging and spectrographic instruments. Recent advances in additive manufacturing (AM) have enabled fabrication of complex structures with nano-scale resolution facilitating the production of highly customizable MCPs. Using AM to produce MCPs potentially has many advantages over traditional fused glass substrates, including better material control (e.g., more robust glasses or ceramics), better control of microscopic features (e.g., unique pore geometries to improve performance), and better control of macroscopic features (e.g., printing precision curved surfaces for focal plane matching). Through a collaboration with industry, national laboratory, and university partners, small format microcapillary array substrates were produced using a standard polymer photoresin. In conclusion, these substrates were functionalized using atomic layer deposition and their performance was compared to current state-of-the-art Pb-glass and borosilicate-glass MCPs.

36 MATERIALS SCIENCE↗

Design and performance analysis of the CLAES Ne/CO2 cryostat

The design of the dual-stage Ne/CO2 cryostat, constructed for the Cryogenic Limb Array Etalon Spectrometer (CLAES) for the cooling, to their respective required operation temperatures, of the focal plane (to less than 15 K), spectrometer (to less than 30 K), telescope (to less than 150 K), and baffles (to less than 180 K) is described, and the cryostat's performance is analyzed. The results of this study show that the current cryostat will meet all sensor cooling requirements. The cryostat weighs 2276 lbs, of which 988 lbs are charged to the neon and 484 lbs are charged to the CO2. Schematic diagrams of the CLAES cooler/sensor and of the external plumbing are presented together with the test data.

Naes, L. G.↗

The X-ray Integral Field Unit (X-IFU) for Athena

Athena is designed to implement the Hot and Energetic Universe science theme selected by the European Space Agency for the second large mission of its Cosmic Vision program. The Athena science payload consists of a large aperture high angular resolution X-ray optics (2 m2 at 1 keV) and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager. The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), oering 2.5 eV spectral resolution, with approximately 5" pixels, over a field of view of 5' in diameter. In this paper, we present the X-IFU detector and readout electronics principles, some elements of the current design for the focal plane assembly and the cooling chain. We describe the current performance estimates, in terms of spectral resolution, effective area, particle background rejection and count rate capability. Finally, we emphasize on the technology developments necessary to meet the demanding requirements of the X-IFU, both for the sensor, readout electronics and cooling chain.

X-ray↗