Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Ronchi shearing interferometry for wavefronts with circular symmetry

Ronchi testing of a focused electromagnetic wave has in the last few years been used extensively at X-ray free-electron laser (FEL) facilities to qualitatively evaluate the wavefront of the beam. It is a quick and straightforward test, is easy to interpret on the fly, and can be used to align phase plates that correct the focus of aberrated beams. In general, a single Ronchigram is not sufficient to gain complete quantitative knowledge of the wavefront. However the compound refractive lenses that are commonly used at X-ray FELs exhibit a strong circular symmetry in their aberration, and this can be exploited. Furthermore, a simple algorithm that uses a single recorded Ronchigram to recover the full wavefront of a nano-focused beam, assuming circular symmetry, is presented, and applied to experimental measurements at the Matter in Extreme Conditions instrument at the Linac Coherent Light Source.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Range and Performance Optimized Version of the Computer-Aided Speckle Interferometry Algorithm for Real-Time Displacement-Strain Field Monitoring

Abstract This work presents an optimized implementation of the Computer-Aided Speckle Interferometry algorithm which enables full-field determination of displacements and strains on commodity Graphics Processing Units at high resolution and frame rates. By combining careful control of the average speckle size in a laser speckle pattern with a simple sampling rate conversion scheme, a compact representation of the optical speckle is achieved. This allows for optimal use of Graphics Processing Unit architecture with robust range extension. The optimal mapping of the Computer-Aided Speckle Interferometry algorithm to Graphics Processing Unit architecture is shown in detail, and a straightforward method for disambiguating large displacements is illustrated. Lastly, this paper demonstrates a two-step subimage-tapering modification to the original algorithm that enables robust range enhancement while maintaining resolution. Results from numerical simulations on synthetic speckle patterns are shown, and runtime performance metrics are provided, with performance ranging up to 60 frames per second in some cases. The method is suitable for interactive experimental mechanics research, process and testing or any application where real-time high-resolution displacement-strain monitoring is needed. A .NET Framework class library enabling the incorporation of the algorithm into 3rd -party applications is available for download.

42 ENGINEERING↗

Vibration measurement by pulse differential holographic interferometry

Technique measures structural deformation of materials subjected to wide range of temperatures and other environmental conditions. Effects of convection currents are eliminated by operating a pulsed laser in double pulse mode that exposes hologram twice in quick succession.

Evensen, D. A.↗

A combined Phase Contrast Imaging and heterodyne interferometer for multiscale fluctuation measurements in tokamak plasmas

An upgrade to the Phase Contrast Imaging (PCI) diagnostic on the DIII-D tokamak has successfully combined PCI with density interferometry to provide electron density fluctuation measurements across an unprecedented range in wavenumber. The combined diagnostic uses a single laser and a single beam path through the tokamak, minimizing machine resources in anticipation of future reactor-scale devices where port access will be at a premium. The PCI multichannel detector provides low-noise, wavenumber-resolved detection of moderate-wavenumber turbulence, while the interferometer channel is sensitive to long-wavelength turbulence, including the peak of ion-scale turbulence and MHD. The overlap in wavenumber range between the two schemes allows for an in situ absolute calibration of the PCI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Photon Acceleration Schemes for Tunable XUV/Soft X-Ray Sources

We report on the advances made under the purview of DOE award number DE-SC0019135 that was active during the period: 09/01/2018–08/31/2021. The grant investigated the application of a “flying focus” to the problem of photon acceleration—in which a dynamic refractive index gradient is used to continuously upshift a probe beam’s frequency. Codes were written to describe the creation of ionization waves of arbitrary velocity (IWAVs) for use as a photon-accelerating medium, as well as the behavior of a witness pulse residing in said medium. Experiments first verified the spatiotemporal control over laser intensity provided by a chromatic flying focus, then used that ability to produce small-diameter IWAVs in the far-field with the expected dynamics, and finally demonstrated even further flexibility by producing large-diameter IWAVs in the laser quasi-far-field that maintained the beneficial dynamics. Multiple innovative diagnostics—spectrally resolved Schlieren and spectrally resolved interferometry—were pioneered in order to diagnose the IWAVs. For IWAV production in the laboratory, however, beam quality was identified as a key limitation in the quasi-far-field. Since the original chromatic flying focus was found to result in relatively long (ps duration) intensity peaks, which could limit some applications including photon acceleration, additional techniques were invented to provide similar spatiotemporal control while also retaining ultrashort intensity peaks. While simulations have identified several interesting regimes for photon acceleration—first predicting the upshift of a counterpropagating witness pulse from the optical to the extreme ultraviolet in less than 1 cm, and later obtaining similar shifts in less than 100 μm in a simpler self-seeded configuration—experimental demonstration is left for future work.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-axis Heterodyne Interferometry at MHz Frequencies: a Short-Arm Measurement Demonstration for LISA with Off-The-Shelf Hardware

We report the design, construction, and operation of a multi-axis heterodyne interferometry (MAHI) system operating at MHz heterodyne frequencies, which provides a testbed for technologies to be used in the Laser Interferometer Space Antenna (LISA) space-based gravitational wave mission. The system was calibrated for measurement of the piston, pitch, and yaw of a three-axis piezo-actuated mirror, giving measured calibration values that closely match those predicted by a simulation based on Gaussian beam tracing. The piston sensitivity of the MAHI system in the LISA band was measured to be below 10pmHz 1/2 10pmHz1/2 for frequencies above 4 mHz and below 1pmHz 1/2 1pmHz1/2 for frequencies above 35 mHz. The sensitivity is limited above 2 Hz by the mechanical vibrations of the apparatus and below 1 mHz by dimensional changes caused by temperature fluctuations. Evidence points towards scattered light as the limiting noise source at intermediate frequencies. The angular sensitivity of the MAHI system was measured to be close to or below 10nradHz 1/2 10nradHz1/2 for frequencies above 4 mHz and below 1nradHz 1/2 1nradHz1/2 for frequencies above 100 mHz. Noise budgets for both length and angle were determined, indicating the areas in which improvements must be made in order to reach increased sensitivity. The current operating sensitivity already provides a useful testbed for LISA technologies and a potential blueprint for future ground segment equipment.

Fulda, P.↗

Single-Shot Diagnostics of Microbunched Electrons in Laser-Driven Plasma Accelerators and Free-Electron Lasers

aThe need for single-shot diagnostics of the periodic longitudinal density modulation of relativistic electrons at the resonant wavelength (microbunching) in a free-electron laser (FEL) or at broadband visible wavelengths as in a laser-driven plasma accelerator (LPA) has been reaffirmed. In the self-amplified spontaneous emission (SASE) FEL case, statistical fluctuations in the microbunching occur in the startup- from-noise process. In the LPA, the plasma itself is chaotic and varies shot to shot. Fortunately, we have shown that coherent optical transition radiation (COTR) techniques, can assess beam size, divergence, spectral evolution, and z-dependent gain (100,000) of microbunched electrons in a past SASE FEL experiment at 530 nm*. Recently, the application to LPAs has been demonstrated with single-shot near-field (NF) and far-field (FF) COTR imaging done at the exit of an LPA for the first time**. In this case few-micron beam sizes and extensive fringes due to su b-mrad divergences were measured based on point-spread-function effects and an analytical model for COTR interferometry (COTRI), respectively. A new COTR-based diagnostics application to pre-bunched electron beams formed by co-propagating a laser pulse and the electron pulse in a short undulator (modulator) is also described.

43 PARTICLE ACCELERATORS↗

Microscale Thermophoresis (MST) as a Tool to Study Binding Interactions of Oxygen-Sensitive Biohybrids

Microscale thermophoresis (MST) is a technique used to measure the strength of molecular interactions. MST is a thermophoretic-based technique that monitors the change in fluorescence associated with the movement of fluorescent-labeled molecules in response to a temperature gradient triggered by an IR LASER. MST has advantages over other approaches for examining molecular interactions, such as isothermal titration calorimetry, nuclear magnetic resonance, biolayer interferometry, and surface plasmon resonance, requiring a small sample size that does not need to be immobilized and a high-sensitivity fluorescence detection. In addition, since the approach involves the loading of samples into capillaries that can be easily sealed, it can be adapted to analyze oxygen-sensitive samples. In this Bio-protocol, we describe the troubleshooting and optimization we have done to enable the use of MST to examine protein–protein interactions, protein–ligand interactions, and protein–nanocrystal interactions. The salient elements in the developed procedures include 1) loading and sealing capabilities in an anaerobic chamber for analysis using a NanoTemper MST located on the benchtop in air, 2) identification of the optimal reducing agents compatible with data acquisition with effective protection against trace oxygen, and 3) the optimization of data acquisition and analysis procedures. The procedures lay the groundwork to define the determinants of molecular interactions in these technically demanding systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A holographic interferometry technique for measuring transonic flow near a rotor blade

A technique that uses holographic interferometry to record the first interferograms of the flow near a hovering transonic rotor blade is presented. A pulsed ruby laser is used to record interferograms of a 2 ft diam field of view near a rotor tip operating at a tip Mach number of 0.90. Several interferograms, recorded along planes perpendicular to the rotor's tip path plane at various azimuth angles around the flow, are presented. These interferograms yield quantitative information about shock structure and location, flow separation, and radiated noise that will help helicopter researchers understand the complexities of the flow around high speed rotor blades and thus improve performance and reduce noise.

Kittleson, J. K.↗

Fourier-transform optical microsystems

The design, fabrication, and initial characterization of a miniature single-pass Fourier-transform spectrometer (FTS) that has an optical bench that measures 1 cm x 5 cm x 10 cm is presented. The FTS is predicated on the classic Michelson interferometer design with a moving mirror. Precision translation of the mirror is accomplished by microfabrication of dovetailed bearing surfaces along single-crystal planes in silicon. Although it is miniaturized, the FTS maintains a relatively high spectral resolution, 0.1 cm-1, with adequate optical throughput.

NASA Discipline Environmental Health↗

SIM vs. SOS: A Space Interferometry Trade Study

This study was undertaken at the Jet Propulsion Laboratory to identify salient features of two competing instrument designs and to select the design that best meets the goals of the Space Interferometry Mission.

trade-study↗

Laser cooling of antihydrogen atoms

The photon—the quantum excitation of the electromagnetic field—is massless but carries momentum. A photon can therefore exert a force on an object upon collision 1 . Slowing the translational motion of atoms and ions by application of such a force 2,3 , known as laser cooling, was first demonstrated 40 years ago 4,5 . It revolutionized atomic physics over the following decades 6–8 , and it is now a workhorse in many fields, including studies on quantum degenerate gases, quantum information, atomic clocks and tests of fundamental physics. However, this technique has not yet been applied to antimatter. Here we demonstrate laser cooling of antihydrogen 9 , the antimatter atom consisting of an antiproton and a positron. By exciting the 1S–2P transition in antihydrogen with pulsed, narrow-linewidth, Lyman-α laser radiation 10,11 , we Doppler-cool a sample of magnetically trapped antihydrogen. Although we apply laser cooling in only one dimension, the trap couples the longitudinal and transverse motions of the anti-atoms, leading to cooling in all three dimensions. We observe a reduction in the median transverse energy by more than an order of magnitude—with a substantial fraction of the anti-atoms attaining submicroelectronvolt transverse kinetic energies. We also report the observation of the laser-driven 1S–2S transition in samples of laser-cooled antihydrogen atoms. The observed spectral line is approximately four times narrower than that obtained without laser cooling. The demonstration of laser cooling and its immediate application has far-reaching implications for antimatter studies. A more localized, denser and colder sample of antihydrogen will drastically improve spectroscopic 11–13 and gravitational 14 studies of antihydrogen in ongoing experiments. Furthermore, the demonstrated ability to manipulate the motion of antimatter atoms by laser light will potentially provide ground-breaking opportunities for future experiments, such as anti-atomic fountains, anti-atom interferometry and the creation of antimatter molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Digital holographic interferometry employing Fresnel transform reconstruction for the study of flow shear stabilized Z-pinch plasmas

The ZaP-HD Flow Z-Pinch project provides a platform to explore how shear flow stabilized Z-pinches could scale to high-energy-density plasma (HEDP) and fusion reactor conditions. ZaP-HD generates shear stabilized, axisymmetric Z-pinches with stable lifetimes approaching $60$$\mu$s. The goal of the project is to increase the plasma density and temperature compared to the previous ZaP project by compressing the plasma to smaller radii ($\approx 1$ mm). Radial and axial plasma electron density structure is measured using digital holographic interferometry (DHI), which provides the necessary fine spatial resolution. ZaP-HD's DHI system uses a 2 ns Nd:YAG laser pulse with a second harmonic generator ($\lambda = 532$ nm) to produce holograms recorded by a Nikon D3200 digital camera. The holograms are numerically reconstructed with the Fresnel transform reconstruction method to obtain the phase shift caused by the interaction of the laser beam with the plasma. This provides a two-dimensional map of line-integrated electron density, which can be Abel inverted to determine the local number density. The DHI resolves line-integrated densities down to $3\times 10^{20}$ m$^{-2}$ with spatial resolution near $10 \mu$m. This work presents the first application of Fresnel transform reconstruction as an analysis technique for a plasma diagnostic, and it analyzes the method's accuracy through study of synthetic data. It then presents an Abel inversion procedure that utilizes data on both sides of a Z-pinch local number density profile to maximize profile symmetry. Error estimation and Abel inversion are applied to measured data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave–photonic low-coherence interferometry for dark zone free distributed optical fiber sensing

A microwave–photonic low-coherence interferometry (MPLCI) system is proposed for fully distributed optical fiber sensing. Assisted by an unbalanced Michelson interferometer, a low-coherence laser source is used to interrogate cascaded Fabry–Perot interferometers along with an optical fiber for a dark zone free (or spatially continuous) distributed measurement. Here, by combining the advantages of microwaves and photonics, the MPLCI system can synergistically achieve high sensitivity and high spatial resolution. Our tests have confirmed a strain resolution of 95 nε at the spatial resolution of 10 cm.

42 ENGINEERING↗