Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

A comparison of price-taker and production cost models for determining system value, revenue, and scheduling of concentrating solar power plants

Concentrating solar power (CSP) plants convert solar energy into electricity and can be coupled with low-cost thermal energy storage to provide a dispatchable renewable resource. Maximizing the economic benefits of CSP systems requires deliberate selection of the timing of thermal energy dispatch to coincide with high-price or high-value periods. The performance and value of CSP systems have traditionally been evaluated using two distinct approaches: (1) production cost models (PCMs), which optimize commitment and dispatch schedules for an entire fleet of generators to minimize the cost of satisfying electricity demand; and (2) price-taker (PT) models, which optimize dispatch of the CSP system against historical or forecasted electricity prices to maximize revenue available to the CSP operator. The PCM approach is, in principle, superior because of the ability to capture system-level details such as transmission pathways and associated constraints, and feedback between CSP dispatch schedules and operation of other generators. The computationally simpler PT technique cannot explicitly address these concerns, but the comparative reduction in solution time is attractive for sensitivity analysis and rigorous optimization of CSP plant design and operation. In this work, we directly compare the dispatch profiles, net revenue, and operational value of CSP systems using implementations of each technique to assess how closely the solutions from the PT technique can approach those from the PCM for a specific market scenario. The PT implementation produced characteristically similar dispatch profiles as the PCM for both a large solar-multiple configuration and a small solar-multiple peaking configuration, while requiring only 1% of the computational time of the PCM. In addition, dispatching the CSP plant according to the self-scheduled PT solution - as opposed to the system-optimized PCM solution - only reduced the total CSP operational value by 1-5%, with consistent trends across CSP configurations and locations. This analysis validates the ability of the PT approach to substantially capture the economic benefits of CSP systems when pricing profiles are available, and indicates that the PT approach is suitable for initial design and optimization of CSP technologies.

14 SOLAR ENERGY↗

Setting cost targets for zero-emission electricity generation technologies

Clean energy deployment scenarios typically assume a diverse mix of low-emission generation. However, because of historically low natural gas prices and cost reductions for onshore wind and photovoltaic technologies, recent new capacity deployment, especially in the United States, has come largely from these three generation sources. Here, we quantify competitive cost targets for three less-common zero-emission generation technologies -- nuclear, concentrating solar, and offshore wind -- under a range of future conditions. We determine the cost targets based on the technologies' system value, such that technology value equals or exceeds its cost. Using a capacity expansion model that develops system-wide, economically optimal generation scenarios of the United States power sector, we find that nuclear, concentrating solar, and offshore wind would need to attain levelized cost ranges of $53-84/MWh, $65-91/MWh, and $39-77/MWh, respectively, to achieve 1% additional grid penetration. We refer to this metric as the 'required cost,' which is a technology's levelized cost of energy needed to achieve a specific penetration level. Higher penetrations lead to lower required costs as lower-cost generation is displaced. We estimate that to reach 10% penetration, the required cost for nuclear declines to $45-76/MWh. Because of resource variability and increased transmission needs for concentrating solar power and offshore wind, even lower costs are needed to reach higher penetrations: required cost ranges to achieve 10% penetration are estimated to be $30-56/MWh and $18-40/MWh for these two technologies respectively. Our analysis informs research and development priorities and the design of policies supporting clean technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The impact of wind, solar, and other factors on the decline in wholesale power prices in the United States

Across multiple organized wholesale power markets in the United States, annual average prices declined by 19–64 dollars per MWh between 2008 and 2017 while retirements of thermal power plants accelerated. Several prominent changes over the last decade are often discussed as contributors to this decline in prices. These include growth in wind and solar, a reduction in the price of natural gas, and weakened load growth. Here we construct a fundamental supply curve model for each of seven organized wholesale market regions and use counterfactual simulations to assess the degree to which wind and solar—among other factors—have influenced wholesale electricity prices. We find that growth in wind and solar since 2008 reduced average annual wholesale electricity prices by less than 3 dollars per MWh. In contrast the decline in natural gas prices reduced wholesale prices by 7–53 dollars per MWh, depending on the region. This suggests that recent thermal-plant retirements in the U.S. are primarily due to low natural gas prices, not growth in wind and solar. Fully isolating the impact of individual factors, however, is limited by non-linear interactions between factors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrified autonomous freight benefit analysis on fleet, infrastructure and grid leveraging Grid-Electrified Mobility (GEM) model

Fast-growing freight activities over the decades have become one of the major contributors to air pollution, leading to many efforts in freight decarbonization and electrification. However, the development of freight electrification is slow due to technological uncertainty, slow charging, high capital cost, etc. This paper analyzes the potential impact and benefit of heavy-duty vehicle (HDV) electrification and automation on fleet cost, infrastructure cost, the electricity grid, and environmental outcomes. In this work, we extended the vehicle electrification benefit analysis tool: Grid-Electrified Mobility (GEM) model, which had primarily been used to study light-duty passenger vehicles (LDVs), to analyze heavy-duty vehicle electrification. The extended model is derived for freight transportation electrification, and different freight electrification and automation adoption scenarios were analyzed. We find that the increased penetration of automated electric freight fleets within other types of electrified freight fleets from 1% to 99% will result in an overall cost reduction of 18.2%, fleet size reduction of 20.4%, and lower peak load reduction of 14.3%.

33 ADVANCED PROPULSION SYSTEMS↗

The Role of Input Assumptions and Model Structures in Projections of Variable Renewable Energy: A Multi-Model Perspective of the U.S. Electricity System

Recent wind and solar deployment in the United States has grown at unprecedented rates, but the extent to which this growth will continue is a key question. Energy-economic planning models are often used to develop future projections of these technologies, and although it is well-understood that model outcomes are sensitive to assumptions about technology developments and market conditions, it is less clear how underlying model structures might impact outcomes. For wind and solar technologies, model structures might be an even larger driver due to the complexity required to represent their variability, uncertainty, and location-dependence. Here, we apply three state-of-the-art electric sector planning models to evaluate variable renewable generation under different conditions with both harmonized and native input assumptions to isolate the impact that model structures might have on deployment outcomes. We find growth in wind and solar deployment in all models under a business-as-usual scenario (without new policies), where the median value for variable renewable energy generation share is found to be 27% by 2050 - but with a wide range of estimates (18-43%), types of renewable technologies deployed, and regional distributions across models. With harmonized assumptions about technology costs and market conditions the range narrows slightly, but a large range in penetration outcomes remains (24-41% by 2050) suggesting that model representations play significant roles in projections of future wind and solar deployment. We also assess the implications of achieving 55% wind and solar penetration by 2050 - to assess potential challenges at higher penetration levels - and the magnitude of variable generation under a carbon-constrained future. Finally, we identify research needs to better assess the future deployment of variable renewable energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the operational characteristics and economic value of pumped thermal energy storage

Pumped thermal energy storage (PTES) systems use an electrically-driven heat pump to store electricity in the form of thermal energy, and subsequently dispatch the stored thermal energy to generate electricity using a thermodynamic heat engine. Optimal day-ahead operational scheduling and annual value of a PTES system based on Joule-Brayton thermodynamic cycles and two-tank molten salt hot thermal storage is evaluated in this work. Production cost models, which simultaneously optimize commitment and dispatch schedules for an entire set of generators to minimize the cost of satisfying electricity demand, are employed to determine system-optimal operation and day-ahead energy value of the PTES system within each of six hypothetical near-future grid scenarios intended to approximately represent the U.S. Western Interconnection or the Texas Interconnection. Sensitivity to grid scenario (including the contribution of variable renewable energy sources), thermal storage capacity, relative heat pump and heat engine capacities, and startup/shutdown cycling costs are evaluated. PTES energy value and heat engine annual capacity factor increase strongly as the contribution of variable renewable resources increases, heat pump capacity increases relative to heat engine capacity, or PTES cycling costs decrease. Grid scenarios in which the contribution of variable renewable energy is dominated by solar photovoltaics (PV) vs. wind produce inherently different PTES operational patterns. Annual PTES energy value within PV-dominated scenarios increased with storage capacity only up to approximately seven hours of full-load discharge capacity, whereas that within wind-dominated scenarios exhibited a continual increase with storage duration up to at least 16 hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiscale molecular dynamics using the matched interface and boundary method

The Poisson-Boltzmann (PB) equation is an established multiscale model for electrostatic analysis of biomolecules and other dielectric systems. PB based molecular dynamics (MD) approach has a potential to tackle large biological systems. Obstacles that hinder the current development of PB based MD methods are concerns in accuracy, stability, efficiency and reliability. The presence of complex solvent-solute interface, geometric singularities and charge singularities leads to challenges in the numerical solution of the PB equation and electrostatic force evaluation in PB based MD methods. Recently, the matched interface and boundary (MIB) method has been utilized to develop the first second order accurate PB solver that is numerically stable in dealing with discontinuous dielectric coefficients, complex geometric singularities and singular source charges. The present work develops the PB based MD approach using the MIB method. New formulation of electrostatic forces is derived to allow the use of sharp molecular surfaces. Accurate reaction field forces are obtained by directly differentiating the electrostatic potential. Dielectric boundary forces are evaluated at the solvent-solute interface using an accurate Cartesian-grid surface integration method. The electrostatic forces located at reentrant surfaces are appropriately assigned to related atoms. Extensive numerical tests are carried out to validate the accuracy and stability of the present electrostatic force calculation. The new PB based MD method is implemented in conjunction with the AMBER package. MIB based MD simulations of biomolecules are demonstrated via a few example systems.

97 MATHEMATICS AND COMPUTING↗

Quantifying the challenge of reaching a 100% renewable energy power system for the United States

We simulate pathways for achieving up to 100% renewable energy (RE) electric power systems for the contiguous United States. Under base conditions, the least-cost buildout has RE penetration growing up to 57% in 2050. Relative to this base scenario, average CO2 abatement costs of achieving 80%, 90%, 95%, and 100% RE are $25, $33, $40, and $61/ton, respectively, with system costs growing from $30 to $36/MWh at 95% (achieved in 2040) and $39/MWh at 100%. Incremental abatement costs from 99% to 100% RE reach $930/ton, driven primarily by the need for firm RE capacity. In addition to the base conditions, we also examined 22 alternative conditions for a buildout of up to 100%. These sensitivities capture different technology trajectories, compliance requirements, requirement timing, electrification, and transmission availability. Nonlinear marginal costs for the last few percent approaching 100% RE were found for all sensitivities, which might motivate alternative nonelectric-sector abatement opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring the impact of increased solar deployment levels on residential electricity bills in India

Here, in this study, the impact of increased solar penetration in the electricity generation mix on residential electricity consumer bills is explored. The study comprises of two sections: simulation of wholesale electricity rates and retail rate modeling. In the first stage, wholesale prices were modeled using a bottom-up long term unit commitment optimization model for different energy mix scenarios based on increased solar penetration, ranging from 5 to 40% on energy basis. The simulations indicated a fall in wholesale prices with increased solar penetration, a result of merit order effect. The simulated wholesale prices were then used to model retail rates for residential consumers. Four different types of retail rates were designed: flat rate, real time pricing, time of use and critical peak pricing. The impact of these retail rate mechanisms on electricity bills of residential consumers was analyzed and it was found that the bill savings achieved from time varying rates are greater than for time invariant rates. With increased solar penetration, customers with time-varying rates are likely to benefit the most from electricity bill savings. Although consumers with flat rate gain bill savings with increased solar penetration, the savings are likely to be lower than with time-varying rates.

14 SOLAR ENERGY↗

Characterizing local high-frequency solar variability and its impact to distribution studies

Accurately representing the local solar variability at timescales relevant to distribution grid operations (30-seconds and shorter) is essential to modeling the impact of solar photovoltaics (PV) on distribution feeders. Due to a lack of available high-frequency solar data, some distribution grid studies have used synthetically-created PV variability or measured PV variability from a different location than their study location. In this work, we show the importance of using accurate solar PV variability inputs in distribution studies. Using high-frequency solar irradiance data from 10 locations in the United States, we compare the ramp rate distributions at the different locations, use a quantitative metric to describe the solar variability, and run distribution simulations using representative 1-week samples from each location to determine the impact of solar variability on the number of tap change operations. Results indicate up to a 300% difference in the number of tap change operations when using PV variability profiles from the different locations.

14 SOLAR ENERGY↗

Electrifying education: Exploring the electrification potential of U.S. School bus fleets

We analyze the operations of 270 diesel school buses across the United States to assess their electrification potential and evaluate the impact of various charging strategies on electricity demand. We find that school buses typically follow a two-route schedule on weekdays, featuring extended dwell times between morning and evening trips. Weekday trip distances average 25 miles, while weekend trips average 42 miles. Charging simulations indicate over 90% of the U.S. school bus fleet could be electrified using current technologies (300-mile range at 1.21 kWh/mile with 19.2-kW depot charging) without modifying existing operating patterns. Depot charging is a key enabler of school bus electrification, however, the strategic placement of charging stations at other locations (e.g., schools) can further increase electrification potential. Additionally, we find electric school bus charging to be highly flexible, with charge management capable of reducing peak charging loads at depots by up to 77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid geothermal-wind integration in the US energy grid

Here, we combine US wind generation—a cheap yet intermittent source of electricity—with the latest geothermal resource estimates to understand the technoeconomic possibilities of pairing enhanced geothermal systems (EGSs) with existing wind farms to develop a hybrid energy system. Using observed generation data from 583 wind farms, generation gaps are quantified and geographically paired with the latest EGS estimates. Results demonstrate that EGS potential within a 1 km 2 footprint can supplement wind generation at 56% of onshore wind farms. Each wind farm can be supplemented by EGSs when 10% of its surface-occupying footprint is available. The cost of EGSs at wind farms is lowest in the western US and southern Texas border and highest in the central US. While further experiments are warranted, a wind + EGS hybrid system offers an opportunity to increase power output from the same land footprint while maximizing the use of existing electrical infrastructure.

EGS↗

Transforming the Process Industries through Electrification: Challenges and Opportunities

For the more than 70 years, the process industries have provided essential fuels and materials for global growth. Increased manufacturing production comes with substantial environmental impact. Reducing environmental impact through process electrification, carbon capture, and other emerging technologies would require large changes throughout the process industries. We review opportunities and challenges related to electrification, focusing on technical, operational, and economic considerations. Here, we conclude that electrification could completely eliminate scope 1 CO 2 emissions, increase product quality, and reduce the equipment size and cost. On the other hand, it calls for a significant expansion of power generation capacity, as well as new paradigms for process design and operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heavy-Duty Truck Electrification and the Impacts of Depot Charging on Electricity Distribution Systems

Major technological advancements and recent policy support are improving the outlook for heavy-duty truck electrification in the United States. In particular, short-haul operations (=200 miles (=322 km)) are prevalent and early candidates for plug-in electric vehicles (EVs) given their short, predictable routes and return-to-base applications, which allows vehicles to recharge when off shift at their depots. Although previous studies investigated the impacts of added electrical loads on distribution systems, which included light-duty EVs, the implications for heavy-duty EV charging are underexplored. Here we summarize the causes, costs and lead times of distribution system upgrades anticipated for depot charging. We also developed synthetic depot charging load profiles for heavy-duty trucks from real-world operating schedules, and found that charging requirements are met at common light-duty EV charging rates (=100 kW per vehicle). Finally, we applied depot charging load profiles to 36 distribution real-world substations, which showed that most can accommodate high levels of heavy-duty EV charging without upgrades.

47 OTHER INSTRUMENTATION↗

Trans-oceanic Remote Power Hardware-in-the-Loop: Multi-site Hardware, Integrated Controller, and Electric Network Co-simulation

Electric system operators are increasingly concerned with the potential system-wide impacts of the large-scale integration of distributed energy resources (DERs) including voltage control, protection coordination, and equipment wear. This prompts a need for new simulation techniques that can simultaneously capture all the components of these large integrated smart grid systems. This paper describes a novel platform that combines three emerging research areas: power systems co-simulation, power hardware in the loop (PHIL) simulation, and lab-lab links. The platform is distributed, real-time capable, allows for easy internet-based connection from geographically-dispersed participants, and is software platform agnostic. We demonstrate its utility by studying real-time PHIL co-simulation of coordinated solar PV firming control of two inverters connected in multiple electric distribution network models, prototypical of U.S. and Australian systems. Here, the novel trans-pacific closed-loop system simulation was conducted in real-time using a power network simulator and physical PV/battery inverter at power at the National Renewable Energy Laboratory in Golden, CO, USA and a physical PV inverter at power at the Commonwealth Scientific and Industrial Research Organisation's Energy Centre in Newcastle, NSW, Australia. This capability enables smart grid researchers throughout the world to leverage their unique simulation capabilities for multi-site collaborations that can effectively simulate and validate emerging smart grid technology solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗