Search NASA⌕ Search

SEARCH · Search NASA

Results for “acquisition function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

High speed, multi-channel, user programmable digital data acquisition system.

As applications for radiation detection become more demanding, and in turn improvements are made in the technology of radiation detection, there is a need for high speed digital detector readout electronics matching these improvements. Specifically, full control over the on-line processing resources of modern digital electronics is desirable so that researchers can develop custom algorithms for special applications.In the proposed effort, the 500 MHz digital readout electronics previously developed by our company will be redesigned to allow user access to the on-line processing resources. In Phase I, the division of online processing into vendor and user firmware sections has been studied on existing hardware. In Phase II, the hardware will be upgraded to better facilitate the division, and the firmware will be restructured into a robust vendor logic block (providing standard functions such as host I/O, on-board memory I/O, energy computation, MCA spectra, timestamps, waveform capture, run statistics, and triggering and timing) and a user logic block for custom algorithms (with templates and examples for frequently used functions). Investigating several options to divide online processing, it was determined that the most promising approach is to “partition” a single FPGA integrated circuit into a vendor and user section, which is supported in newer devices. The analog front end of the existing electronics proved suitable for most applications, in particular high rate measurements with germanium detectors. The design architecture for new electronics was developed, combining one of the new FPGA device with the analog front end.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study Results and Plans for Future Improvement of the NSLS-II FOFB System

Currently, the fast orbit feedback (FOFB) system correct the transverse orbit in both planes via air coil magnets installed over low conductivity sections of vacuum chamber (stainless steel bellows) with a fast acquisition (FA) that samples at 10kHz. Bandwidth of a few kHz has been achieved (power-supply + corrector + vacuum chamber) for the purpose that the FOFB bandwidth limitation is not anymore limited by the correctors. The bandwidths of the FOFB system in both planes have been experimentally characterized in the open-loop condition via sinwave excitation method. They are significantly lower than the measurements (2.5kHz in x) done by Weixing Chen et al when the control system was largely bypassed, only from PSI to fast correctors, final to BPM. The estimated dI/dt as a function of the frequency from the beam noise spectrum has been compared to the slew rate of the power supply. The most recent study evidences: after the optimization of fast corrector compensation circuit, the power supply system along shows the 3dB bandwidth of 5.6kHz in the horizontal plane and 3.5kHz in the vertical plane. Preliminary beam studies indicate the potential increase of the system bandwidth and the gain within the FOFB bandwidth. Finally, the plan for combing the FOFB and SOFB systems to correct down to DC has been discussed.

36 MATERIALS SCIENCE↗

Monitoring of Temperature Measurements for Different Flow Regimes in Water and Galinstan with Long Short-Term Memory Networks and Transfer Learning of Sensors

Temperature sensing is one of the most common measurements of a nuclear reactor monitoring system. The coolant fluid flow in a reactor core depends on the reactor power state. We investigated the monitoring and estimation of the thermocouple time series using machine learning for a range of flow regimes. Measurement data were obtained, in two separate experiments, in a flow loop filled with water and with liquid metal Galinstan. We developed long short-term memory (LSTM) recurrent neural networks (RNNs) for sensor predictions by training on the sensor’s own prior history, and transfer learning LSTM (TL-LSTM) by training on a correlated sensor’s prior history. Sensor cross-correlations were identified by calculating the Pearson correlation coefficient of the time series. The accuracy of LSTM and TL-LSTM predictions of temperature was studied as a function of Reynolds number (Re). The root-mean-square error (RMSE) for the test segment of time series of each sensor was shown to linearly increase with Re for both water and Galinstan fluids. Using linear correlations, we estimated the range of values of Re for which RMSE is smaller than the thermocouple measurement uncertainty. For both water and Galinstan fluids, we showed that both LSTM and TL-LSTM provide reliable estimations of temperature for typical flow regimes in a nuclear reactor. The LSTM runtime was shown to be substantially smaller than the data acquisition rate, which allows for performing estimation and validation of sensor measurements in real time.

Pantopoulou, Stella↗

SAMPA Based Streaming Readout Data Acquisition Prototype

We have assembled a small-scale streaming data acquisition system based on the SAMPA front-end ASIC. The 32-channel SAMPA chip was designed for the high-luminosity upgrade of the ALICE Time Projection Chamber (TPC) detector at the CERN Large Hadron Collider. The goals of the prototype system are to determine if the SAMPA chip is appropriate for use in detector systems at Jefferson Lab, and to gain experience with the hardware and software required to deploy streaming data acquisition systems in nuclear physics experiments. The 800 channel system is composed of components used in the ALICE TPC data acquisition upgrade. Five front-end cards (FEC) support five SAMPA chips each. SAMPA data streams on an FEC are concentrated into two high-speed (4.48 Gb/s) serial data streams by a pair Gigabit Transceiver ASICs (GBTx). These ten streams (44.8 Gb/s) are transmitted from the FECs over fibers to a PCIe based readout unit. The FPGA engine on the readout unit compresses data for transmission to a server via 100 Gb ethernet. Components on the FECs are radiation tolerant. High data rates can be handled. The system is by design scalable and thus provides a functional prototype for high-rate streaming readout at Jefferson Lab and the future Electron Ion Collider. We have made fundamental measurements (noise, linearity, time resolution) on the SAMPA ASIC. We have also coupled the readout system to a small Gas Electron Multiplier (GEM) detector and have studied its response to cosmic rays. A beam test of the system is planned.

ABBOTT, David↗

SU-E-T-597: Parameterization of the Photon Beam Dosimetry for a Commercial Linear Accelerator

Purpose: In radiation therapy, accurate data acquisition of photon beam dosimetric quantities is important for (1) beam modeling data input into a treatment planning system (TPS), (2) comparing measured and TPS modelled data, (3) a linear accelerator’s (linac) beam characteristics quality assurance process, and (4) establishing a standard data set for data comparison, etcetera. Parameterization of the photon beam dosimetry creates a portable data set that is easy to implement for different applications such as those previously mentioned. The aim of this study is to develop methods to parameterize photon percentage depth doses(PDD), profiles, and total scatter output factors(Scp). Methods: Scp, PDDs and profiles for different field sizes (from 2×2 to 40×40cm{sup 2}), depths and energies were measured in a linac using a three-dimensional water tank. All data were smoothed and profile data were also centered, symmetrized and geometrically scaled. The Scp and PDD data were analyzed using exponential functions. For modelling of open and wedge field profiles, each side was divided into three regions described by exponential, sigmoid and Gaussian equations. The model’s equations were chosen based on the physical principles described by these dosimetric quantities. The equations’ parameters were determined using a least square optimization method with the minimal amount of measured data necessary. The model’s accuracy was then evaluated via the calculation of absolute differences and distance–to–agreement analysis in low gradient and high gradient regions, respectively. Results: All differences in the PDDs’ buildup and the profiles’ penumbra regions were less than 2 mm and 0.5 mm, respectively. Differences in the low gradient regions were 0.20 ± 0.20% and 0.50 ± 0.35% for PDDs and profiles, respectively. For Scp data, all differences were less than 0.5%. Conclusion: This novel analytical model with minimum measurement requirements proved to accurately calculate PDDs, profiles, and Scp for different field sizes, depths and energies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Representing leaf and root physiological traits in CLM improves global carbon and nitrogen cycling predictions

In many ecosystems, nitrogen is the most limiting nutrient for plant growth and productivity. However, current Earth System Models (ESMs) do not mechanistically represent functional nitrogen allocation for photosynthesis or the linkage between nitrogen uptake and root traits. The current version of CLM (4.5) links nitrogen availability and plant productivity via (1) an instantaneous downregulation of potential photosynthesis rates based on soil mineral nitrogen availability, and (2) apportionment of soil nitrogen between plants and competing nitrogen consumers assumed to be proportional to their relative N demands. However, plants do not photosynthesize at potential rates and then downregulate; instead photosynthesis rates are governed by nitrogen that has been allocated to the physiological processes underpinning photosynthesis. Furthermore, the role of plant roots in nutrient acquisition has also been largely ignored in ESMs. We therefore present a new plant nitrogen model for CLM4.5 with (1) improved representations of linkages between leaf nitrogen and plant productivity based on observed relationships in a global plant trait database and (2) plant nitrogen uptake based on root-scale Michaelis-Menten uptake kinetics. Our model improvements led to a global bias reduction in GPP, LAI, and biomass of 70%, 11%, and 49%, respectively. Furthermore, water use efficiency predictions were improved conceptually, qualitatively, and in magnitude. The new model's GPP responses to nitrogen deposition, CO 2 fertilization, and climate also differed from the baseline model. The mechanistic representation of leaf-level nitrogen allocation and a theoretically consistent treatment of competition with belowground consumers led to overall improvements in global carbon cycling predictions.

54 ENVIRONMENTAL SCIENCES↗

TU-H-206-03: Characterizing B1 Inhomogeneities in DCE MRI

Purpose: Dynamic Contrast Enhanced (DCE) MRI is a valuable technique for measuring perfusion and permeability characteristics of tumors. Exogenous contrast concentrations are calculated based on changes in T{sub 1} measured using fast 3D gradient echo (FLASH) sequences. However, the slab selective pulses used in 3D MRI may result in B{sub 1} inhomogeneities across the volume of interest that can lead to errors in T{sub 1} and thus the estimated gadolinium concentration. We compared three FLASH DCE sequences (GRE, TWIST, and VIBE) to determine their signal homogeneity across slices and the accuracy in calculating T{sub 1} using acquisitions with variable flip angles. Methods: The sequences were tested at 3 T on a Siemens mMR (VB20P) using a doped water phantom 3.75 g/L NiSO{sub 4} - 6H{sub 2}O + 5 g/L NaCl (T{sub 1} = 104 ms) and a 2% agar, 0.67% NaCl phantom (T{sub 1}= 1.71 s). 2D EPI B{sub 1} maps and inversion recovery T{sub 1}maps were acquired for ground truth. 3D MRI was acquired at different flip angles to generate a T{sub 1} map. Regions of interest were drawn to measure signal inside the phantoms as a function of slice position. The T{sub 1} for each slice ROI was fit to the FLASH steady-state model of magnetization. Results: Based on the data, GRE gave the most uniform signal homogeneity and T{sub 1} values in the middle slices of the 3D volume. The 3D VIBE sequence had the largest region of signal inhomogeneity compared to the 3D GRE and TWIST sequences. VIBE’s B{sub 1} inhomogeneity is inconsistent at low flip angles. However, VIBE resulted in more slices with T{sub 1} values similar to the ground truth. Conclusion: The central 1/3 of the slices yielded signals that result in T{sub 1} fits consistent with the ground truth. However, the remaining slices required some form of B{sub 1} inhomogeneity correction for quantitative DCE analysis. The research was supported in part by NIH NCI Grant R01CA159471.

60 APPLIED LIFE SCIENCES↗

Virulence factors and antimicrobial resistance profiles of Campylobacter isolates recovered from consecutively reused broiler litter

ABSTRACT Campylobacterinfections are a leading cause of bacterial diarrhea in humans globally. Infections are due to consumption of contaminated food products and are highly associated with chicken meat, with chickens being an important reservoir forCampylobacter. Here, we characterized the genetic diversity ofCampylobacter jejuni(C. jejuni) andCampylobacter coli(C. coli) detected in broiler chicken litter over three consecutive flocks and determined their antimicrobial resistance (ARM) and virulence factor (VF) profiles.Campylobacterwas detected in 9.38% (27/288) of litter samples collected. Antimicrobial susceptibility testing and whole genome sequencing were performed onC. jejuni(n= 39) andC. coli(n= 5) isolates.Campylobactervirulence factors differed within and across broiler houses but were explained by the broiler flock cohort raised on litter,Campylobacterspecies andCampylobactermultilocus sequence type (MLST). Virulence factors involved in the ability to invade and colonize host tissues and evade host defenses were present inC. jejuniisolates (ST-464) from flock cohorts 1 and 2 but absent inC. jejuniisolates (ST-48) from flock cohort 3.C. jejuniisolates from house three harbored a significantly higher proportion of virulence genes with functions related to glycosylation and immune evasion thanC. jejuniisolates from houses 1 and 2 (P< 0.01). AllC. jejuniisolates were susceptible to all antibiotics tested whileC. coli(n= 4) were resistant to tetracycline and harbored the tetracycline resistant ribosomal protection protein (TetO). Our results suggest that house environment and broiler management practices imposed selective pressures on virulence factors and antimicrobial resistance genes ofCampylobacter. IMPORTANCE Campylobacteris a leading cause of foodborne illness in the United States due to consumption of contaminated or mishandled food products, often associated with chicken meat.Campylobacteris common in the microbiota of avian and mammalian gut; however, acquisition of antimicrobial resistance genes (ARGs) and virulence factors (VFs) may result in strains that pose significant threat to public health. Although there are studies investigating the genetic diversity ofCampylobacterstrains isolated from post-harvest chicken samples, there are limited data on the genome characteristics of isolates recovered from preharvest broiler production. Here, we show thatCampylobacter jejuniandCampylobacter colidiffer in their carriage of antimicrobial resistance and virulence factors may also differ in their ability to persist in litter during consecutive grow-out of broiler flocks. We found that presence/absence of virulence factors needed for evasion of host defense mechanisms and gut colonization played an integral role in differentiatingCampylobacterstrains.

Microbiology↗

VERIFICATION MEASUREMENTS OF THE MASS AND ENRICHMENT OF URANIUM OXIDE CARD SOURCES

Measurements were performed to determine the mass and enrichment of 10 uranium oxide (U3O8) card sources. The measurements and analysis were completed as a verification of the card sources in support of Oak Ridge National Laboratory’s nuclear material control and accountability program. Although these cards are not nationally accredited as a nuclear standard, they are used as a working reference for measurements, such as holdup. The uranium card source measurements were taken with a broad energy germanium detector and the Genie 2000 Gamma Acquisition and Analysis software. A complete characterization of each of the 10 uranium card sources was performed using the 4 characteristic full energy peaks of 235U. Using the In Situ Object Counting System software to determine the mathematical efficiency of the measurement, the mass of 235U in each card was determined. The 235U mass in each card ranged from 10.42 to 12.63 g with a systematic error between 0.76 and 0.95 g and a random error of 0.01 g for each card source. The Multi-Group Analysis for Uranium (MGAU) software and the Fixed-Energy, Response Function Analysis with Multiple Efficiency (FRAM) isotopic analysis software were used to determine the isotopic composition of the uranium cards. The measured enrichment was compared to the declared enrichment for each card, with uncertainties ranging from 2.7% to 4.3% for the MGAU analysis and 2.3% to 4.1% for the FRAM analysis. This is a good example of how a well-benchmarked mathematical calibration method can be useful in characterizing uranium sources.

Hunneke, Rachel↗

Authentication Protocol for ICS without Encryption

Industrial control systems (ICS) describes the different types of control systems and associated instrumentation, which includes the devices, systems, networks, and controls used to operate and/or automate industrial processes. Depending on the industry, each ICS functions differently and are built to electronically manage tasks efficiently. Historically, industrial plants have included networking, and changes have been made over time without consideration for security. Many ICS devices currently have inadequate security features. Adding encryption in ICS is undesirable because many of the new detection method involves deep packet inspection. Therefore, we propose to develop a method of providing authentication between devices without encrypting the data. This testbed design will allow rapid development and experimentation with Cyber Physical Systems. Modbus connects to a supervisory computer with a Remote Terminal Unit (RTU) in Supervisory Control and Data Acquisition (SCADA) systems. Our project seeks to enhance security in the ICS environment by adding device authentication to the lower levels of the plant floor. This approach was selected as it allows verification of the sender of data from level 1/level 0 devices up to supervisory systems. This addition is desirable as it adds enhanced verification to the integrity of system data without obscuring (via encryption) the data being transmitted across the network. This is important because many ICS systems are real time critical (decryption adds to latency) and many other good security options require deep packet inspection (which encryption completely defeats). To accomplish this, a proof of concept of adding an authentication scheme was designed and will be tested with a common ICS protocol. The setup includes a single serial cable connecting the serial ports on two devices, a Master and a Minion. Authentication will occur in the following methods: - Data layer involving Transport Layer Security/Secure Socket Layer (TLS/SSL); - TCP/IP route implementation; - Key exchange algorithm; - Raspberry Pi programming for authentication. A portion of the setup includes adding Raspberry Pi into the system as the device is handling the authentication for the network traffic. Modbus is the chosen ICS protocol. It is used to transmit signals from instrumentation and control devices back to a main controller or data gathering system. Typically, the device identity is assumed but not verified. For verifying device identity, we constructed a digital signature architecture with TLS. A novel adaptation of this is to use only the digital signature that is provided and not the encryption capability. This allows ICS traffic to flow unobscured while still providing verification for the integrity of the data. Verification of this process will involve adding additional I/O level network devices with spoofed IP addresses and detecting the authenticated versus unauthenticated traffic. Our TLS implementation will have encryption disabled but should still allow for digital signing of data. This will enable our system to distinguish between real end devices and spoofed end devices. This experiment is presently building the test setup. It is focusing on a small setting to identify authenticated and unauthenticated devices on the network. This should allow for scaling to a larger network size after the initial proof of concept. One concern with this scheme is a certificate deployment has a large scale key management. Network size will thus increase the key management task for security. In addition, we believe that further research should be done on exploring the use of this method to defeat man-in-the-middle attacks.

42 ENGINEERING↗

Identification of genes that regulate phosphate acquisition and plant performance during arbuscular my corrhizal symbiosis in medicago truncatula and brachypodium distachyon

Most vascular flowering plants have the ability to form symbiotic associations with arbuscular mycorrhizal (AM) fungi. The symbiosis develops in the roots and can have a profound effect on plant productivity, largely through improvements in plant mineral nutrition. Within the root cortical cells, the plant and fungus create novel interfaces specialized for nutrient transfer, while the fungus also develops a network of hyphae in the rhizosphere. Through this hyphal network, the fungus acquires and delivers phosphate and nitrogen to the root. In return, the plant provides the fungus with carbon. In addition, to enhancing plant mineral nutrition, the AM symbiosis has an important role in the carbon cycle, and positive effects on soil health. Here we identified and characterized plant genes involved in the regulation and functioning of the AM symbiosis in Medicago truncatula and Brachypodium distachyon. This included the identification and and characterization of a M. truncatula transcription factors that are required for symbiosis. Additionally, we investigated the molecular basis of functional diversity among AM symbioses in B. distachyon and analysed the transcriptome of Brachypodium distachyon during symbiosis.

59 BASIC BIOLOGICAL SCIENCES↗

Binary pseudorandom array test standard optimized for characterization of large field-of-view optical interferometers

Recently, a technique for calibrating the modulation transfer function (MTF) of a broad variety of metrology instrumentation has been demonstrated. This technique is based on test samples structured as one-dimensional binary pseudo-random (BPR) sequences and two-dimensional BPR arrays (BPRAs). The inherent power spectral density of BPR gratings (sequences) and arrays has a deterministic white-noise-like character that allows direct determination of the MTF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. As such, the BPR samples satisfy the characteristics of a test standard: functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. Here we discuss our recent developments directed to the optimization of the sample design, fabrication, application, and data processing procedures, suitable for thorough characterization of large aperture optical interferometers. Compared with the previous coded-aperture based design, the improved, 'highly randomized' BPRA pattern of the new test standard provides better accuracy and reliability of instrument MTF and aberration characterization, and enables operation optimization of large aperture optical interferometers. We describe the pattern generation algorithm and tests to verify the compliance to desired BPRA topography. The data acquisition and analysis procedures for different applications of the technique are also discussed.

Yashchuk, Valeriy V.↗

A high performance cost-effective digital complex correlator for an X-band polarimetry survey

The detailed knowledge of the Milky Way radio emission is important to characterize galactic foregrounds masking extragalactic and cosmological signals. The update of the global sky models describing radio emissions over a very large spectral band requires high sensitivity experiments capable of observing large sky areas with long integration times. Here, we present the design of a new 10 GHz (X-band) polarimeter digital backend to map the polarization components of the galactic synchrotron radiation field of the Northern Hemisphere sky. The design follows the digital processing trends in radio astronomy and implements a large bandwidth (1 GHz) digital complex cross-correlator to extract the Stokes parameters of the incoming synchrotron radiation field. The hardware constraints cover the implemented VLSI hardware description language code and the preliminary results. The implementation is based on the simultaneous digitized acquisition of the Cartesian components of the two linear receiver polarization channels. The design strategy involves a double data rate acquisition of the ADC interleaved parallel bus, and field programmable gate array device programming at the register transfer mode. The digital core of the back-end is capable of processing 32 Gbps and is built around an Altera field programmable gate array clocked at 250 MHz, 1 GSps analog to digital converters and a clock generator. The control of the field programmable gate array internal signal delays and a convenient use of its phase locked loops provide the timing requirements to achieve the target bandwidths and sensitivity. This solution is convenient for radio astronomy experiments requiring large bandwidth, high functionality, high volume availability and low cost. Of particular interest, this correlator was developed for the Galactic Emission Mapping project and is suitable for large sky area polarization continuum surveys. The solutions may also be adapted to be used at signal processing subsystem levels for large projects like the square kilometer array testbeds.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantized Constant-Q Gabor Atoms for Sparse Binary Representations of Cyber-Physical Signatures

Increased data acquisition by uncalibrated, heterogeneous digital sensor systems such as smartphones present new challenges. Binary metrics are proposed for the quantification of cyber-physical signal characteristics and features, and a standardized constant-Q variation of the Gabor atom is developed for use with wavelet transforms. Two different continuous wavelet transform (CWT) reconstruction formulas are presented and tested under different signal to noise ratio (SNR) conditions. A sparse superposition of Nth order Gabor atoms worked well against a synthetic blast transient using the wavelet entropy and an entropy-like parametrization of the SNR as the CWT coefficient-weighting functions. The proposed methods should be well suited for sparse feature extraction and dictionary-based machine learning across multiple sensor modalities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

The CMS Event-Builder System for LHC Run 3 (2021-23)

The data acquisition system (DAQ) of the CMS experiment at the CERN Large Hadron Collider (LHC) assembles events of 2MB at a rate of 100 kHz. The event builder collects event fragments from about 750 sources and assembles them into complete events which are then handed to the highlevel trigger (HLT) processes running on O(1000) computers. The aging eventbuilding hardware will be replaced during the long shutdown 2 of the LHC taking place in 2019/20. The future data networks will be based on 100 Gb/s interconnects using Ethernet and Infiniband technologies. More powerful computers may allow to combine the currently separate functionality of the readout and builder units into a single I/O processor handling simultaneously 100 Gb/s of input and output trac. It might be beneficial to preprocess data originating from specific detector parts or regions before handling it to generic HLT processors. Therefore, we will investigate how specialized coprocessors, e.g. GPUs, could be integrated into the event builder. We will present the envisioned changes to the event-builder compared to today’s system. Initial measurements of the performance of the data networks under the event-building trac pattern will be shown. Implications of a folded network architecture for the event building and corresponding changes to the software implementation will be discussed. Corresponding author: remigius.mommsen@cern.c

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: I. A theoretical model

Purpose: Dual-energy (DE) iodine contrast-enhanced x-ray imaging of the breast has been shown to identify cancers that would otherwise be mammographically occult. In this article, theoretical modeling was performed to obtain optimally enhanced iodine images for a photon-counting digital breast tomosynthesis (DBT) system using a DE acquisition technique. Methods: In the system examined, the breast is scanned with a multislit prepatient collimator aligned with a multidetector camera. Each detector collects a projection image at a unique angle during the scan. Low-energy (LE) and high-energy (HE) projection images are acquired simultaneously in a single scan by covering alternate collimator slits with Sn and Cu filters, respectively. Sn filters ranging from 0.08 to 0.22 mm thickness and Cu filters from 0.11 to 0.27 mm thickness were investigated. A tube voltage of 49 kV was selected. Tomographic images, hereafter referred to as DBT images, were reconstructed using a shift-and-add algorithm. Iodine-enhanced DBT images were acquired by performing a weighted logarithmic subtraction of the HE and LE DBT images. The DE technique was evaluated for 20-80 mm thick breasts. Weighting factors, w{sub t}, that optimally cancel breast tissue were computed. Signal-difference-to-noise ratios (SDNRs) between iodine-enhanced and nonenhanced breast tissue normalized to the square root of the mean glandular dose (MGD) were computed as a function of the fraction of the MGD allocated to the HE images. Peak SDNR/{radical}(MGD) and optimal dose allocations were identified. SDNR/{radical}(MGD) and dose allocations were computed for several practical feasible system configurations (i.e., determined by the number of collimator slits covered by Sn and Cu). A practical system configuration and Sn-Cu filter pair that accounts for the trade-off between SDNR, tube-output, and MGD were selected. Results: w{sub t} depends on the Sn-Cu filter combination used, as well as on the breast thickness; to optimally cancel 0% with 50% glandular breast tissue, w{sub t} values were found to range from 0.46 to 0.72 for all breast thicknesses and Sn-Cu filter pairs studied. The optimal w{sub t} values needed to cancel all possible breast tissue glandularites vary by less than 1% for 20 mm thick breasts and 18% for 80 mm breasts. The system configuration where one collimator slit covered by Sn is alternated with two collimator slits covered by Cu delivers SDNR/{radical}(MGD) nearest to the peak value. A reasonable compromise is a 0.16 mm Sn-0.23 mm Cu filter pair, resulting in SDNR values between 1.64 and 0.61 and MGD between 0.70 and 0.53 mGy for 20-80 mm thick breasts at the maximum tube current. Conclusions: A DE acquisition technique for a photon-counting DBT imaging system has been developed and optimized.

60 APPLIED LIFE SCIENCES↗

{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms. Point spread function (PSF) correction and TOF reconstruction in general reduce background variability and noise and increase recovered concentration. Results for patient data indicated a good correlation between the expected and PET reconstructed activities. A linear relationship between the expected and the measured activities in the organ of interest was observed for all reconstruction method used: a linearity coefficient of 0.89 ± 0.05 for the Biograph mCT and 0.81 ± 0.05 for the Biograph TruePoint. Conclusions: Due to the low counts and high random fraction, accurate image quantification of {sup 90}Y during selective internal radionuclide therapy is affected by random coincidence estimation, scatter correction, and any positivity constraint of the algorithm. Nevertheless, phantom and patient studies showed that the impact of number of true and random coincidences on quantitative results was found to be limited as long as ordinary Poisson ordered subsets expectation maximization reconstruction algorithms with random smoothing are used. Adding PSF correction and TOF information to the reconstruction greatly improves the image quality in terms of bias, variability, noise reduction, and detectability. On the patient studies, the total activity in the field of view is in general accurately measured by Biograph mCT and slightly overestimated by the Biograph TruePoint.

60 APPLIED LIFE SCIENCES↗