Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic scale imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Optimizing Cr(VI) and Tc(VII) remediation through nano-scale biomineral engineering

To optimize the production of biomagnetite for the bioremediation of metal oxyanion contaminated waters, the reduction of aqueous Cr(VI) to Cr(III) by two biogenic magnetites and a synthetic magnetite was evaluated under batch and continuous flow conditions. Results indicate that nano-scale biogenic magnetite produced by incubating synthetic schwertmannite powder in cell suspensions of Geobacter sulfurreducens is more efficient at reducing Cr(VI) than either biogenic nano-magnetite produced from a suspension of ferrihydrite 'gel' or synthetic nano-scale Fe{sub 3}O{sub 4} powder. Although X-ray Photoelectron Spectroscopy (XPS) measurements obtained from post-exposure magnetite samples reveal that both Cr(III) and Cr(VI) are associated with nanoparticle surfaces, X-ray Magnetic Circular Dichroism (XMCD) studies indicate that some Cr(III) has replaced octahedrally coordinated Fe in the lattice of the magnetite. Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) measurements of total aqueous Cr in the associated solution phase indicated that, although the majority of Cr(III) was incorporated within or adsorbed to the magnetite samples, a proportion ({approx}10-15 %) was released back into solution. Studies of Tc(VII) uptake by magnetites produced via the different synthesis routes also revealed significant differences between them as regards effectiveness for remediation. In addition, column studies using a {gamma}-camera to obtain real time images of a {sup 99m}Tc(VII) radiotracer were performed to visualize directly the relative performances of the magnetite sorbents against ultra-trace concentrations of metal oxyanion contaminants. Again, the magnetite produced from schwertmannite proved capable of retaining more ({approx}20%) {sup 99m}Tc(VII) than the magnetite produced from ferrihydrite, confirming that biomagnetite production for efficient environmental remediation can be fine-tuned through careful selection of the initial Fe(III) mineral substrate supplied to Fe(III)-reducing bacteria.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nucleon Tomography Studies at Jefferson Lab

Protons and neutrons, are the building blocks of atomic nuclei. They constitute over 99 percent of the mass of the matter in the visible universe. A fundamental challenge of modern nuclear physics is to understand the structure of these constituents. The 12 GeV Upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab and the construction of state-of-the-art detector systems make it a unique facility in the world to address this challenge. Electron scattering is a superb experimental tool to study the internal structure of nucleons at differing distance scales, as the resolving power of the probe can be varied. The CEBAF Upgrade was completed in September 2017 and the new generation of experiments has started. These experiments will enable a collaboration of scientists from around the world to perform precise experiments of exclusive processes covering a large range in kinematics to effectively engage in nuclear imaging, revealing hidden aspects of its internal structure, and providing insight into quark confinement forces in the nucleon, one of the greatest mysteries of modern physics. The Generalized Parton Distributions (GPDs) provide the theoretical framework to interpret the experimental data in terms of 3-dimensional imaging. In addition, recent development demonstrated that the GPD formalism enables access to the nucleon's Gravitational Form Factors that encode its mechanical properties. We will focus on the study of the Deeply Virtual Compton Scattering (DVCS), the most effective way to access GPDs. We will review the landscape of both theory and experiment, and discuss the latest results from Jefferson Lab at 6 GeV in comparison with results from other facilities, and present a first look at the new experiments with the 12 GeV Upgrade.

Elouadrhiri, Latifa↗

The Third Flight of the Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS-3)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is the first X-ray slitless imaging spectrograph sounding rocket instrument designed to observe spectrally dispersed soft X-ray images of the solar corona over a wide field-of-view. During the first flight of MaGIXS (MaGIXS-1), occurred on 30 July 2021, several emission lines from coronal structures including X-ray bright points were observed. Further, MaGIXS-1 analysis also demonstrated the successful inversion of overlappograms using robust unfolding algorithms. Given the demonstrated success of MaGIXS-1, the second flight of the instrument with a simplified optical design, MaGIXS-2, is scheduled for 2024 to observe high temperature diagnostic emission lines. Results from MaGIXS-1 discovered dominant missing emission lines near 15A, arising from relatively cool plasma that peaks around 2 MK. This wavelength region hosts several closely spaced satellite lines of Fe XVII, Fe XVI and Fe XV ions, which are expected to be enhanced at lower temperatures and are currently unmodeled in the CHIANTI atomic database. This wavelength region offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The goal of MaGIXS-3 mission is the to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. To meet this goal, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 14.9 to 15.9A, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging↗

Spectral and polarization based imaging in deep-ultraviolet excited photoelectron microscopy

Using photoelectron emission microscopy, nanoscale spectral imaging of atomically thin MoS2 buried between Al2O3 and SiO2 is achieved by monitoring the wavelength and polarization dependence of the photoelectron signal excited by deep-ultraviolet light. Although photons induce the photoemission, images can exhibit resolutions below the photon wavelength as electrons sense the response. To validate this concept, the dependence of photoemission yield on the wavelength and polarization of the exciting light was first measured and then compared to simulations of the optical response quantified with classical optical theory. A close correlation between experiment and theory indicates that photoemission probes the optical interaction of UV-light with the material stack directly. The utility of this probe is then demonstrated when both the spectral and polarization dependence of photoemission observe spatial variation consistent with grains and defects in buried MoS2. Taken together, these new modalities of photoelectron microscopy allow mapping of optical property variation at length scales unobtainable with conventional light-based microscopy.

Beechem, Thomas E. (ORCID:0000000275360719)↗

Kelvin probe force microscopy for high-resolution imaging of hydrogen in steel alloys [Poster]

Kelvin probe force microscopy (KPFM) was used to image and co-locate the presence of hydrogen in stainless steel (SS) with microstructure. Various SS samples were investigated, including forged, welded, LENS® fabricated, and pinch welded materials. KPFM images the local work function of a surface as a function of spatial position using atomic force microscopy. KPFM is capable of delivering high spatial (~10 nm) and potential (~5mV) resolution maps characterizing the microstrucure and the locally varying work function of surfaces. Hydrogen segregated at the surface of SS increases the local work function by either reducing tensile strain or by reducing the chemical potential of surface species. In a process known as hydrogen embrittlement, hydrogen segregates to and becomes trapped at extended defects (e.g. dislocations, boundaries, pores) which leads to the initiation of cracking and can result in structural failure. Hydrogen storage necessitates a proper understanding of the mechanisms of hydrogen embrittlement in SS. Developing advanced characterization techniques for hydrogen embrittlement is critical to identify long term solutions for materials exposed to hydrogen. Current techniques of observing hydrogen embrittlement involve mechanical testing, and optical microscopy with low resolution. Advance microstructural imaging techniques capable of resolving features down to the nanometer scale are needed. KPFM provides high resolution imaging for the characterization and development of SS components for hydrogen storage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of 10nm diameter carbon nanopores

The addition of carbon to samples, during imaging, presents a barrier to accurate TEM analysis, the controlled deposition of hydrocarbons by a focused electron beam can be a useful technique for local nanometer-scale sculpting of material. Here we use hydrocarbon deposition to form nanopores from larger focused ion beam (FIB) holes in silicon nitride membranes. Using this method, we close 100-200nm diameter holes to diameters of 10nm and below, with deposition rates of 0.6nm per minute. I-V characteristics of electrolytic flow through these nanopores agree quantitatively with a one dimensional model at all examined salt concentrations.

36 MATERIALS SCIENCE↗

Collection of fluorescence from an ion using trap-integrated photonics

Spontaneously emitted photons are entangled with the electronic and nuclear degrees of freedom of the emitting atom, so interference and measurement of these photons can entangle separate matter-based quantum systems as a resource for quantum information processing. Since confinement in a single-mode facilitates the photon interference needed for generating entanglement, the dipole emission patterns relevant in spontaneous emission present a mode-matching challenge. Current demonstrations rely on bulk photon-collection and manipulation optics that suffer from large component size and system-to-system variability—factors that impede scaling to the large numbers of entangled pairs needed for quantum information processing. To address these limitations, we demonstrate a collection method that enables passive phase stability, straightforward photonic manipulation, and intrinsic reproducibility. Specifically, we engineer a waveguide-integrated grating to couple photons emitted from a trapped ion into a single optical mode within a microfabricated ion-trap chip. Using the integrated collection optic, we characterize the collection efficiency, image the ion, and detect the ion’s quantum state. The integrated optic covers 2.18% of the solid angle and collects 1.97 ± 0.3% of the spontaneously emitted light incident on the grating for a total collection efficiency of 0.043% into a single-mode waveguide. This proof-of-principle demonstration lays the foundation for leveraging the inherent stability and reproducibility of integrated photonics to create, manipulate, and measure multipartite quantum states in arrays of quantum emitters.

Optical physics↗

Sensitivity enhancement of grating interferometer based two-dimensional sensor arrays using two-wavelength readout

Diffraction gratings integrated with microelectromechanical systems (MEMS) sensors offer displacement measurements with subnanometer sensitivity. However, the sensitivity of the interferometric readout may drop significantly based on the gap between the grating and the reference surface. A two-wavelength (2-{lambda}) readout method was previously tested using a single MEMS sensor for illustrating increased displacement measurement capability. This work demonstrates sensitivity enhancement on a sensor array with large scale parallelization ({approx}20,000 sensors). The statistical representation, which is developed to model sensitivity enhancement within a grating based sensor array, is supported by experimental results using a thermal sensor array. In the experiments, two lasers at different wavelengths (633 and 650 nm) illuminate the thermal sensor array from the backside, time-sequentially. The diffracted first order light from the array is imaged onto a single CCD camera. The target scene is reconstructed by observing the change in the first diffracted order diffraction intensity for both wavelengths. Merging of the data from two measurements with two lasers was performed by taking the larger of the two CCD measurements with respect to the reference image for each sensor. {approx}30% increase in the average sensitivity was demonstrated for a 160x120 pixel IR sensor array. Proposed architecture is also applicable to a variety of sensing applications, such as parallel biosensing and atomic force microscopy, for improved displacement measurements and enhanced sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cold and warm atomic gas around the Perseus molecular cloud. II. The impact of high optical depth on the HI column density distribution and its implication for the HI-TO-H{sub 2} transition

We investigate the impact of high optical depth on the HI saturation observed in the Perseus molecular cloud by using Arecibo HI emission and absorption measurements toward 26 radio continuum sources. The spin temperature and optical depth of individual HI components are derived along each line of sight, enabling us to estimate the correction for high optical depth. We examine two different methods for the correction, Gaussian decomposition and isothermal methods, and find that they are consistent (maximum correction factor ∼1.2), likely due to the relatively low optical depth and insignificant contribution from the diffuse radio continuum emission for Perseus. We apply the correction to the optically thin HI column density on a pixel-by-pixel basis and find that the total HI mass increases by ∼10%. Using the corrected HI column density image and far-infrared data from the IRIS Survey, we then derive the H{sub 2} column density on ∼0.4 pc scales. For five dark and star-forming sub-regions, the HI surface density is uniform with Σ{sub HI} ∼ 7–9 M{sub ⊙} pc{sup −2}, in agreement with the minimum HI surface density required for shielding H{sub 2} against photodissociation. As a result, Σ{sub H{sub 2}}/Σ{sub HI} and Σ{sub HI}+Σ{sub H{sub 2}} show a tight relation. Our results are consistent with predictions for H{sub 2} formation in steady state and chemical equilibrium and suggest that H{sub 2} formation is mainly responsible for the Σ{sub HI} saturation in Perseus. We also compare the optically thick HI with the observed “CO-dark” gas and find that the optically thick HI only accounts for ∼20% of the “CO-dark” gas in Perseus.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative NO{sub 2} molecular tagging velocimetry at 500 kHz frame rate

NO{sub 2} molecular tagging velocimetry (MTV) is demonstrated at repetition rates as high as 500 kHz in a laboratory scale Mach 5 wind tunnel. A pulse burst laser and a home built optical parametric oscillator system were used to simultaneously generate the required 355 and 226 nm wavelengths for NO{sub 2} photodissociation (tagging) and NO planar laser induced fluorescence imaging (interrogation), respectively. NO{sub 2} MTV images were obtained both in front and behind the characteristic bow shock from a 5 mm diameter cylinder. From Gaussian curve fitting, an average free stream flow velocity of 719 m/s was obtained. Absolute statistical precision in velocity of {approx}11.5 m/s was determined, corresponding to relative precision of 1.6%-5%, depending upon the region of the flow probed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High speed nano-metrology

For manufacturing at the nanometre scale a method for rapid and accurate measurement of the resultant functional devices is required. Although atomic force microscopy (AFM) has the requisite spatial resolution, it is severely limited in scan speed, the resolution and repeatability of vertical and lateral measurements being degraded when speed is increased. Here we present a new approach to AFM that makes a direct and feedback-independent measurement of surface height using a laser interferometer focused onto the back of the AFM tip. Combining this direct height measurement with a passive, feedback-free method for maintaining tip-sample contact removes the constraint on scan speed that comes from the bandwidth of the z-feedback loop. Conventional laser reflection detection is used for feedback control, which now plays the role of minimising tip-sample forces, rather than producing the sample topography. Using the system in conjunction with a rapid scanner, true height images are obtained with areas up to (36 x 36) {mu}m{sup 2} at 1 image/second, suitable for in-line applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional two-fluid Braginskii simulations of the large plasma device

The Large Plasma Device (LAPD) is modeled using the 3D Global Braginskii Solver code. Comparisons to experimental measurements are made in the low-bias regime in which there is an intrinsic E × B rotation of the plasma. In the simulations, this rotation is caused primarily by sheath effects and may be a likely mechanism for the intrinsic rotation seen in LAPD. Simulations show strong qualitative agreement with the data, particularly the radial dependence of the density fluctuations, cross-correlation lengths, radial flux dependence outside of the cathode edge, and camera imagery. Kelvin Helmholtz (KH) turbulence at relatively large scales is the dominant driver of cross-field transport in these simulations with smaller-scale drift waves and sheath modes playing a secondary role. Plasma holes and blobs arising from KH vortices in the simulations are consistent with the scale sizes and overall appearance of those in LAPD camera images. The addition of ion-neutral collisions in the simulations at previously theorized values reduces the radial particle flux by about a factor of two, from values that are somewhat larger than the experimentally measured flux to values that are somewhat lower than the measurements. This reduction is due to a modest stabilizing contribution of the collisions on the KH-modes driving the turbulent transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of a broadband x-ray crystal spectrometer using a continuum x-ray source and photon-counting detectors

We report measurements of sensitivity of a broadband (≃20–30 keV) x-ray crystal spectrometer using a bremsstrahlung continuum x-ray source and several detectors, including an energy-discriminating photon-counting point detector (Si drift diode, Amptek Inc.), imaging hybrid photon-counting detectors (Eiger2-Si and Eiger2-CdTe, DECTRIS Ltd.), and image plates (SR type). Sensitivity is defined as a ratio of the crystal-reflected energy-position-dispersed spectrum measured by a given detector to the incident non-dispersed spectrum measured using the energy-discriminating point detector. The sensitivity derived from data measured exclusively by the point detector is considered detector-independent and serves as a reference. The sensitivities derived from data collected with the hybrid photon-counting detectors were matched to the reference using a scale factor of 1.05. The image plate-derived sensitivities required a scale factor of 1.16 to match the reference. Furthermore, the resulting mismatch in the shapes of all measured scaled sensitivities in the range of the spectrometer was ≲±10%, while the mismatch between the shapes of the sensitivities corresponding to the Si-based detectors was ≲±2.5%.

Crystal optics↗

Segregation and Phase Transformations Along Superlattice Intrinsic Stacking Faults in Ni-Based Superalloys

In this study, local chemical and structural changes along superlattice intrinsic stacking faults combine to represent an atomic-scale phase transformation. In order to elicit stacking fault shear, creep tests of two different single crystal Ni-base superalloys, ME501 and CMSX-4, were performed near 750 degrees Centigrade using stresses of 552 megapascals and 750 megapascals, respectively. Through high resolution Scanning Transmission Electron Microscopy (STEM) and state-of-the-art energy dispersive x-ray spectroscopy, ordered compositional changes were measured along SISFs (Superlattice Intrinsic Stacking Faults) in both alloys. For both instances, the elemental segregation and local crystal structure present along the SISFs are consistent with a nanoscale to D019 (ordering of a hexagonal close-packed crystal) phase transformation. Another notable observation is prominent Cr- and Co-rich Cottrell atmospheres and new evidence of more complex reordering processes responsible for the formation of these faults. These findings are further supported using density functional theory calculations and High Angle Annular Dark Field (HAADF) STEM image simulations.

STEM-EDS↗

Nanoscale imaging of Gilbert damping using signal amplitude mapping

Ferromagnetic resonance force microscopy (FMRFM) is a powerful scanned probe technique that uses sub-micrometer-scale, spatially localized standing spin wave modes (LMs) to perform local ferromagnetic resonance (FMR) measurements. In this work, we show the spatially resolved imaging of Gilbert damping in a ferromagnetic material (FM) using FMRFM. Typically damping is measured from the FMR linewidth. We demonstrate an approach to image the spatial variation of Gilbert damping utilizing the LM resonance peak height to measure the LM resonance cone angle. This approach enables determination of damping through field-swept FMRFM at a single excitation frequency. The extreme force sensitivity of similar to 2 fN at room temperature can resolve changes of Gilbert damping as small as ~2 x 10 -4 at 2GHz, corresponding to ~0.16Oe in FMR linewidth resolution. This high sensitivity, high spatial resolution, and single frequency imaging of Gilbert damping creates the opportunity to study spin interactions at the interface between an insulating FM and a small volume of nonmagnetic material such as atomically thin two-dimensional materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transport characterization and pinning analysis of BaFe 1.9 Ni 0.1 As 2.05 thin films

In this paper, we report on the vortex-glass transition and superconducting performance of BaFe 1.9 Ni 0.1 As 2.05 thin films with T c = 17.8 K on CaF 2 (00 l ) single crystals by pulsed laser deposition. Atomic force microscopy characterization indicates the volumes of droplets appearing on the film surface increase with thickness and Magneto-optical imaging proves slight inhomogeneities in the current flow within the ab -plane of thin film. The thin films show a transport current density J c of ~1.14 MA cm –2 in self-field, and 0.34 and 0.28 MA cm –2 for H // c and H // ab up to 9 T at 4.2 K. Pinning mechanism associated with the fluctuations in the mean free path of the charge carries is found to be dominant in the thin films. The vortex-glass (VG) to vortex-liquid phase transition is identified in terms of the plots of the logarithmic derivative of the resistivity curves under different fields, allowing us to deduce the values of the VG transition temperature T g , and the critical exponent s . The ρ – T curves are well scaled by VG theory. A phase diagram combining the VG transition temperature, irreversibility field and upper critical field is constructed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Growth of crystalline Al{sub 2}O{sub 3} via thermal atomic layer deposition: Nanomaterial phase stabilization

We report the growth of crystalline Al{sub 2}O{sub 3} thin films deposited by thermal Atomic Layer Deposition (ALD) at 200 °C, which up to now has always resulted in the amorphous phase. The 5 nm thick films were deposited on Ga{sub 2}O{sub 3}, ZnO, and Si nanowire substrates 100 nm or less in diameter. The crystalline nature of the Al{sub 2}O{sub 3} thin film coating was confirmed using Transmission Electron Microscopy (TEM), including high-resolution TEM lattice imaging, selected area diffraction, and energy filtered TEM. Al{sub 2}O{sub 3} coatings on nanowires with diameters of 10 nm or less formed a fully crystalline phase, while those with diameters in the 20–25 nm range resulted in a partially crystalline coating, and those with diameters in excess of 50 nm were fully amorphous. We suggest that the amorphous Al{sub 2}O{sub 3} phase becomes metastable with respect to a crystalline alumina polymorph, due to the nanometer size scale of the film/substrate combination. Since ALD Al{sub 2}O{sub 3} films are widely used as protective barriers, dielectric layers, as well as potential coatings in energy materials, these findings may have important implications.

36 MATERIALS SCIENCE↗

Experimental inference of neutral and impurity transport in Alcator C-Mod using high-resolution x-ray and ultra-violet spectra

We present experimental inferences of cross-field impurity transport coefficients for AlcatorC-Mod plasmas without edge-localized modes, leveraging a novel forward model for the entire Ca Kα spectrum, including satellite lines within the spectral range, to compare to high-resolution x-ray imaging crystal spectroscopy (XICS). These measurements are complemented by extreme ultra-violet (EUV) spectroscopy that constrains transport closer to the edge. Using new atomic data sets for both XICS and EUV analysis has enabled consideration of line ratios across both spectral ranges and has increased the accuracy of inferred transport coefficients. Inclusion of charge exchange between edge thermal neutrals and impurities is shown to be extremely important in C-Mod pedestals. Atomic D neutral densities from experimental D Lyα measurements at the midplane are compared to SOLPS-ITER simulations, finding good agreement. Bayesian inferences of impurity transport coefficients are presented for L-, EDA H-, and I-mode discharges, making use of the Aurora package for forward modeling and combining our spectroscopic constraints. Experimentally inferred diffusion profiles are found to match turbulent transport models at midradius within uncertainties, using both quasilinear gyro-fluid TGLF SAT-1 and nonlinear ion-scale gyrokinetic CGYRO simulations. Furthermore, significant discrepancies in convection are observed in some cases, suggesting difficulties in predictions of flat or hollow impurity profiles.

neutrals↗