Search NASA⌕ Search

SEARCH · Search NASA

Results for “control methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Methods of Phase and Power Control in Magnetron Transmitters for Superconducting Accelerators

Various methods of phase and power control in magnetron RF sources of superconducting accelerators intended for ADS-class projects were recently developed and studied with conventional 2.45 GHz, 1 kW, CW magnetrons operating in pulsed and CW regimes. Magnetron transmitters excited by a resonant (injection-locking) phasemodulated signal can provide phase and power control with the rates required for precise stabilization of phase and amplitude of the accelerating field in Superconducting RF (SRF) cavities of the intensity-frontier accelerators. An innovative technique that can significantly increase the magnetron transmitter efficiency at the widerange power control required for superconducting accelerators was developed and verified with the 2.45 GHz magnetrons operating in CW and pulsed regimes. High efficiency magnetron transmitters of this type can significantly reduce the capital and operation costs of the ADSclass accelerator projects.

43 PARTICLE ACCELERATORS↗

Passivity-Based Control of Grid Forming and Grid Following Converters in Microgrids

With the integration of more and more power electronics devices into the grid, it is not easy to guarantee the stability of the whole system due to the complexity of the control structure of various power converters. In this paper, we consider grid-forming and grid-following converters in one microgrid, in which the grid-forming converters support the voltage and frequency of the microgrid and the grid-following converters inject their maximum power into the microgrid. To handle the stability issue, the passivity principle is applied to guarantee the stability of the whole microgrid. We ensure every grid-following converter satisfies the passivity via the port-controlled Hamiltonian method. In addition, we apply the passivity-based proportional-resonant controller to the grid-forming converter. One of the advantages of the proposed method is that the phase lock loop system is eliminated, which may cause stability issues. Simulation results show that the proposed method can control the microgrid effectively.

Gui, Yonghao (Young)↗

Fuel governor for controlled autoignition engines

Methods and systems for controlling combustion performance of an engine are provided. A desired fuel quantity for a first combustion cycle is determined. One or more engine actuator settings are identified that would be required during a subsequent combustion cycle to cause the engine to approach a target combustion phasing. If the identified actuator settings are within a defined acceptable operating range, the desired fuel quantity is injected during the first combustion cycle. If not, an attenuated fuel quantity is determined and the attenuated fuel quantity is injected during the first combustion cycle.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Guide for Selecting Appropriate Human Factors Methods and Measures in Control Room Modernization Efforts in Nuclear Power Plants

Abstract. Many of the U.S. nuclear power plants are approaching the end of their 60-year licensing period. The U.S. Department of Energy Light Water Reactor Sustainability Program is conducting targeted research to extend the lives and ensure long-term reliability, productivity, safety, and security of these plants through targeted research, such as with integrating advanced digital instrumentation and control technologies in the main control room. There are many challenges to this, one being the integration of human factors engineering in the design and evaluation of these upgrades. This paper builds upon recent efforts in developing utility-specific guidance for integrating human factors engineering in the control room modernization process by providing commonly used data collection methods that are applicable at various phases of the upgrade process. Advantages and disadvantages of each method is provided for consideration of an optimal human factors evaluation plan to be used throughout the lifespan of the upgrade process.

99 GENERAL AND MISCELLANEOUS↗

Vanadium oxide for infrared coatings and methods thereof

The present invention relates to vanadium oxide and methods of controlling reaction processes for making such materials (e.g., powders). In particular embodiments, the method includes control of oxygen partial pressure in order to kinetically control the oxidation species of the crystalline vanadium oxide material. Other methods, uses, systems, protocols, and coatings are also described.

Rodriguez, Mark A.↗

Vanadium oxide for infrared coatings and methods thereof

The present invention relates to vanadium oxide and methods of controlling reaction processes for making such materials (e.g., powders). In particular embodiments, the method includes control of oxygen partial pressure in order to kinetically control the oxidation species of the crystalline vanadium oxide material. Other methods, uses, systems, protocols, and coatings are also described.

36 MATERIALS SCIENCE↗

Issues about implementation of geometry control to maintain nuclear criticality safety - 14438

The control of the geometry to establish and maintain Nuclear Criticality Safety (NCS) of a fissile unit is usually preferred by licensees and regulators since such a control is based on passive engineering and requires less operating constraints than other methods of control (mass, etc.). Nevertheless, several safety issues are associated with this method of control to ensure the geometry during all the unit lifetime, in normal and abnormal situations, from its manufacturing to its decommissioning. The first issue is to identify the dimensions defining the geometry, taking into account reflectors and mobile equipment, and the interaction conditions of the controlled unit to ensure the subcriticality. Thus, the dimensions important and to be controlled are identified in the NCS assessment. These dimensions are called Nuclear Criticality Safety Dimensions (NCSD) in this paper. Then, the second and the third issues are to define NCSD limits to be respected and to verify the compliance of the actual unit geometry with these limits at each stage of the unit life. Regarding the third issue, the challenges are the practicality of the control, its uncertainty and the management of non-compliances. Finally, the fourth issue is to properly document and record the NCSD and the compliance verification. This paper focuses on the main issues related to the implementation of geometry control on the NCS assessment and suggests advices to fulfill these challenges. (authors)

42 ENGINEERING↗

Synthesis Methods for Nanoparticle Morphology Control in Energy Applications

Lightweight nano-composite materials, nano-coatings, nanocatalysts, nano-structured materials have demonstrated an ability to reduce emissions and maximize clean energy production. Nanoparticles play an important role in engineering and decarbonization for energy applications, and a wide range of nanoparticle synthesis methods have been developed to include those that enable control over particle morphology. The ability to control nanoparticle morphology allows the tailoring and improvement of material properties that will accelerate efforts towards lowering carbon emissions by developing advanced catalysts for carbon sequestration and will enhance energy efficient processes and technologies. Synthesis methods aimed towards shape control of nanoparticles have demonstrated an ability to form spheres, rods, flower-like shapes, cubes, plates, shells, and chiral geometries. Processing methods used to form these morphologies include microwave assisted synthesis, solvothermal, hydrothermal, and a wide range of capping agents. A discussion of a few of these methods is given along with results and applications.

36 MATERIALS SCIENCE↗

Controlled placement and orientation of nanostructures

A method for controlled deposition and orientation of molecular sized nanoelectromechanical systems (NEMS) on substrates is disclosed. The method comprised: forming a thin layer of polymer coating on a substrate; exposing a selected portion of the thin layer of polymer to alter a selected portion of the thin layer of polymer; forming a suspension of nanostructures in a solvent, wherein the solvent suspends the nanostructures and activates the nanostructures in the solvent for deposition; and flowing a suspension of nanostructures across the layer of polymer in a flow direction; thereby: depositing a nanostructure in the suspension of nanostructures only to the selected portion of the thin layer of polymer coating on the substrate to form a deposited nanostructure oriented in the flow direction. By selectively employing portions of the method above, complex NEMS may be built of simpler NEMSs components.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Application of deep learning methods for beam size control during user operation at the Advanced Light Source

Past research at the Advanced Light Source (ALS) provided a proof-of-principle demonstration that deep learning methods could be effectively employed to compensate for the significant perturbations to the transverse electron beam size induced by user-controlled adjustments of the insertion devices. However, incorporating these methods into the ALS’ daily operations has faced notable challenges. The complexity of the system’s operational requirements and the significant upkeep demands has restricted their sustained application during user operation. Here, we introduce the development of a more robust neural network (NN)-based algorithm that utilizes a novel online fine-tuning approach and its systematic integration into the day-to-day machine operations. Our analysis emphasizes the process of NN model selection, demonstrates the superior performance of the NN-based method over traditional feedback methods, and examines the effectiveness and resilience of the new algorithm during user-operation scenarios. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Plasma Modeling Results and shape control improvements for NSTX

New control implementations and dynamics studies on the National Spherical Torus eXperiment (NSTX) are summarized. In particular, strike point (SP) position, X-point height and squareness control, and two new system-identification methods / control-tuning algorithms were put into operation.The PID controller for the SP was tuned by analyzing the step response of the SP position to the poloidal coil currents, employing the Ziegler-Nichols method. The resulting SP controller was successfully employed to achieve the “snowflake” divertor configuration in NSTX. An offline system identification of the plasma response to the control inputs based on ARMAX input-output models was implemented. With this tool, rough estimates of the improvements were realized and several control improvements were identified.An online automatic relay-feedback PID tuning algorithm was implemented, which has the advantage of tuning the controller in one shot, thus optimizing the use of experimental time. Furthermore, using these new capabilities, we implemented LLD scenarios with control for theall four upper/lower/inner/outer SPs and with a combined X-point height, SP radius control. Separately, an independent squareness control was implemented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heating tar sands formations while controlling pressure

Methods for treating a tar sands formation are described herein. Methods may include heating at least a section of a hydrocarbon layer in the formation from a plurality of heaters located in the formation. A pressure in the majority of the section may be maintained below a fracture pressure of the formation. The pressure in the majority of the section may be reduced to a selected pressure after the average temperature reaches a temperature that is above 240.degree. C. and is at or below pyrolysis temperatures of hydrocarbons in the section. At least some hydrocarbon fluids may be produced from the formation.

Stegemeier, George Leo↗

Hybrid vehicle control

A method and apparatus for heating a catalytic converter's catalyst to an efficient operating temperature in a hybrid electric vehicle when the vehicle is in a charge limited mode such as e.g., the charge depleting mode or when the vehicle's high voltage battery is otherwise charge limited. The method and apparatus determine whether a high voltage battery of the vehicle is incapable of accepting a first amount of charge associated with a first procedure to warm-up the catalyst. If it is determined that the high voltage battery is incapable of accepting the first amount of charge, a second procedure with an acceptable amount of charge is performed to warm-up the catalyst.

33 ADVANCED PROPULSION SYSTEMS↗

Control of matrix converters using machine learning

A method of controlling a matrix converter system is provided. The method includes receiving an operating condition and consulting a trained Q-data structure for reward values associated with respective switching states of the switching matrix for an operating state that corresponds to the operating condition. The Q-data structure is trained using Q-learning to map a reward value predicted for respective switching states to respective discrete operating states. The method further includes sorting the reward values predicted for the respective switching states mapped to the operating state that corresponds to the operating condition, selecting a subset of the set of the mappings as a function of a result of sorting the reward values associated with the switching states of the operating state, evaluating each switching state included in the subset, and selecting an optimal switching state for the operating condition based on a result of evaluating the switching states of the subset.

Chamie, Mahmoud El↗

Multi-agent voltage control in distribution systems using GAN-DRL-based approach

Active distribution grids can experience voltage fluctuations and violations due to the high penetration of variable distributed energy resources (DERs). These problems might occur because of the uncertain and variable generation natures of these resources, especially solar photovoltaic resources, during panel shadowing scenarios. Volt-VAR control (VVC) is an efficient method that controls the reactive power set-points of the inverters to regulate the voltage of distribution grids. Although several VVC approaches have been proposed recently, the performance of these approaches degrades significantly if behind-the-meter solar generation data are unobservable/missing. Therefore, it is necessary to impute missing/unobservable PV data accurately to be utilized in VVC approaches. Further, this paper proposes a model-free, data-driven, centrally trained, and decentrally executed multi-agent deep reinforcement learning-based VVC architecture to regulate the voltage of distribution networks. A generative adversarial network (GAN) is incorporated to impute the unobservable PV data accurately, which improves the performance of the proposed control architecture. The proposed multi-agent-soft-actor–critic algorithm (MASAC)-based VVC technique utilizes the actual PV dataset as well as the imputed dataset from the GAN framework to learn the optimal coordinated control policy for controlling the optimal reactive power set-points of PV inverters. The effectiveness of the proposed approach is analyzed on a modified IEEE 34-bus test case with added PV inverters. The results are compared and analyzed with a base case model with no VVC and VVC with a local droop control approach, genetic algorithm optimization, and a centralized soft actor–critic-based approach. Moreover, the performance of the proposed approach is compared with that of a multi-agent VVC framework without using the PV generation data and load information as the system state. The results illustrate that the proposed method with more state input improves the voltage profile and reduces the power loss of the network across various loading and PV generation scenarios.

14 SOLAR ENERGY↗

SU-E-I-24: Method for CT Automatic Exposure Control Verification

Purpose: Design of a phantom and a simple method for the automatic exposure control (AEC) verification in CT. This verification is included in the computed tomography (CT) Spanish Quality Assurance Protocol. Methods: The phantom design is made from the head and the body phantom used for the CTDI measurement and PMMA plates (35×35 cm2) of 10 cm thickness. Thereby, three different thicknesses along the longitudinal axis are obtained which permit to evaluate the longitudinal AEC performance. Otherwise, the existent asymmetry in the PMMA layers helps to assess angular and 3D AEC operation.Recent acquisition in our hospital (August 2014) of Nomex electrometer (PTW), together with the 10 cm pencil ionization chamber, led to register dose rate as a function of time. Measurements with this chamber fixed at 0° and 90° on the gantry where made on five multidetector-CTs from principal manufacturers. Results: Individual analysis of measurements shows dose rate variation as a function of phantom thickness. The comparative analysis shows that dose rate is kept constant in the head and neck phantom while the PMMA phantom exhibits an abrupt variation between both results, being greater results at 90° as the thickness of the phantom is 3.5 times larger than in the perpendicular direction. Conclusion: Proposed method is simple, quick and reproducible. Results obtained let a qualitative evaluation of the AEC and they are consistent with the expected behavior. A line of future development is to quantitatively study the intensity modulation and parameters of image quality, and a possible comparative study between different manufacturers.

07 ISOTOPE AND RADIATION SOURCES↗

A Measurement-Based Adaptive Voltage Regulation Method Considering Topology Changes

This paper proposes an online adaptive data-driven distributed energy resource (DER) dispatch optimization method for voltage control considering topology changes. By using a local sensitivity factor (LSF)-enabled voltage control, traditional DER control can be reformulated into a linear programming (LP) problem, leading to faster computation speeds. Power injection alteration and topology changes are two common operational changes in the distribution network that can affect the LSF and voltage control performance. To address this issue, a robust estimation method is developed to adjust the sensitivity matrix at each time step for the time-varying power injection changes. When topology changes occur, only the allocated predominant LSF submatrices are updated based on measurement data, allowing for a fast adaptation to the system reconfiguration. Results obtained from a real distribution feeder in Southern California demonstrate its robustness as compared to traditional volt-var control and constant LSF matrix dispatch control methods.

DERs↗