Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical interconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Length mode piezoelectric ultrasonic transducer for inspection of solid objects

The transducer is constructed from individual transducer elements arranged in an array and configured to exhibit a predominant, longitudinal mode transversely to the array. The elements are interconnected through thin flexible sheets. Each element is individually damped, and the transducer as a whole is electrically damped through resonance with the clamped capacitance and dissipation. Electrical control permits inphase operation of all transducer elements or control with preselected phase differences.

Thompson, R. B.↗

Research directions and progress in SERI advanced high efficiency concepts program

Novel solar cell designs and materials with the objective of achieving the maximum attainable photovoltaic conversion efficiencies are researched. Laboratory demonstrations of solar cells of greater than 30% efficiency under concentrated sunlight and thin film solar cells with one sun efficiencies of 17 to 20% are sought. These demonstrations are necessary intermediate steps towards the realization of very high efficiency, multi-bandgap, thin-film solar cells. Conversion efficiencies above 30% could be achieved by a cascade multijunction cell consisting of a high bandgap (1.7 eV) cell coupled optically and electrically on top of a lower bandgap (1.1 eV) cell. Recent improvements in peak currents of this interconnect are quite promising. However, this cell structure poses difficult problems for materials fabrication as a result of the combined requirements of choice of bandgaps, low defect density material, and high doping densities. Recent improvements in the quality of materials and newly proposed cell structures which may simplify fabrication are significant steps in the development of the multijunction concentrator solar cell.

Benner, J. P.↗

Surface Micro-Machining: Progress Towards Micro-Electro Mechanical Systems

Surface micromachining is a technique for building electromechanical systems in silicon. A number of electromechanical systems have been implemented in miniature using the fundamental structural building blocks of tensile and non-tensile springs, differential capacitance sensing cells, and electrostatic drive. The integration of complicated mechanical structures and electrical circuits onto a single chip is expected to improve reliability and testability of systems. Reduction in interconnect wiring, the increased use of automation, and the inherent reliability of integrated circuits will all contribute to increased reliability of systems.

Doscher, James↗

MIR Solar Array Return Experiment: Power Performance Measurements and Molecular Contamination Analysis Results

A solar array segment was recently removed from the Mir core module and returned for ground-based analysis. The segment, which is similar to the ones the Russians have provided for the FGB and Service Modules, was microscopically examined and disassembled by US and Russian science teams. Laboratory analyses have shown the segment to he heavily contaminated by an organic silicone coating, which was converted to an organic silicate film by reactions with atomic oxygen within the. orbital flight environment. The source of the contaminant was a silicone polymer used by the Russians as an adhesive and bonding agent during segment construction. During its life cycle, the array experienced a reduction in power performance from approx. 12%, when it was new and first deployed, to approx. 5%, when it was taken out of service. However, current-voltage measurements of three contaminated cells and three pristine, Russian standard cells have shown that very little degradation in solar array performance was due to the silicate contaminants on the solar cell surfaces. The primary sources of performance degradation is attributed to "thermal hot-spotting" or electrical arcing; orbital debris and micrometeoroid impacts; and possibly to the degradation of the solar cells and interconnects caused by radiation damage from high energy protons and electrons.

Visentine, James↗

Printed circuit board impedance matching step for microwave (millimeter wave) devices

An impedance matching ground plane step, in conjunction with a quarter wave transformer section, in a printed circuit board provides a broadband microwave matching transition from board connectors or other elements that require thin substrates to thick substrate (>quarter wavelength) broadband microwave (millimeter wave) devices. A method of constructing microwave and other high frequency electrical circuits on a substrate of uniform thickness, where the circuit is formed of a plurality of interconnected elements of different impedances that individually require substrates of different thicknesses, by providing a substrate of uniform thickness that is a composite or multilayered substrate; and forming a pattern of intermediate ground planes or impedance matching steps interconnected by vias located under various parts of the circuit where components of different impedances are located so that each part of the circuit has a ground plane substrate thickness that is optimum while the entire circuit is formed on a substrate of uniform thickness.

42 ENGINEERING↗

A method for assessing economic, environmental, and reliability tradeoffs of interregional transmission connecting ERCOT (the Texas grid) to the eastern and western grids

Reliable development of the power grid is an evolving concern for humanity due to extreme weather that frequently threatens power sector infrastructure. The state of Texas is a uniquely structured testbed for grid planners to study when looking for solutions to development, innovation, and overcoming such challenges. Because of its size and islanded structure, Texas is small enough to model, but big enough to matter. Texas is a global leader in energy production, energy consumption, and maintains an unusually diverse fuel mix. In addition, the state has experienced winter freezes, heat waves, wind storms, droughts and floods that have threatened power sector infrastructure or caused recent blackouts and calls for demand side conservation. One of the most devastating of these events was the North American winter storm, dubbed “Winter Storm Uri” by the Weather Channel, that froze the region in February 2021 and led to an extended power outage event that put the majority of Texan residents in darkness for days. While preparing to avoid such outage events in the future, various tools have been proposed to improve grid reliability, including energy efficiency, demand response, and distributed energy resources. An additional option would be to develop interregional transmission that connects the Texas grid to other national grids. To assess the merits of this idea, we developed a novel, universally-applicable and internationally-relevant framework to study how the Texas grid would evolve alongside access to various interregional ties. This method allows us to stress the synthetic grid structure and analyze how it would respond to the shock of a simulated winter storm event. Our method leverages open-source modeling tools, such as PowerGenome, pyGRETA, and GenX to synthesize unique zonal grid data, construct a consolidated network of model regions, and simulate different developmental pathways of capacity expansion and operational dispatch. We demonstrate our method with an analysis connecting the Electric Reliability Council of Texas (ERCOT), the grid that serves most of Texas, the Western Electricity Coordinating Council (WECC), the grid that serves the western half of the contiguous U.S., and the Eastern Interconnect, the grid that serves the eastern half of the contiguous U.S. Our results indicate that the cost-optimal capacity of interregional transmission connecting the ERCOT grid to other grids lies between 9–13 GW assuming baseline conditions. Building this amount of connecting capacity in one or multiple directions lowers the costs and emissions of development and operation by up to $16 billion and 257 million metric tonnes (MMT) respectively. Additionally, our results show that the interregional connections between ERCOT and other national grids reduce the amount of total load shed required through mild winter storm events. However, our results also show that there is a threshold of very extreme winter storm conditions, spanning multiple service areas, above which the connections exacerbate resource adequacy problems. Therefore, the results indicate that the connections need to be carefully planned alongside the rest of the grid infrastructure to avoid over-reliance on specific resources or technology options.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rational Design of Hierarchically Open-Porous Spherical Hybrid Architectures for Lithium Ion Batteries

Controlling the internal microstructure and overall morphology of building blocks used to form hybrid materials is crucial for the realization of deterministically designed architectures with desirable properties. Here, we demonstrate an integrative spray-frozen (SF) assembly for forming hierarchically structured open-porous microspheres (hpMSs) composed of Fe 3 O 4 and reduced graphene oxide (rGO). The SF process drives the formation of a radially-aligned microstructure within the sprayed colloidal droplets and also controls the overall microsphere morphology. The Fe 3 O 4 /rGO hpMSs contain interconnected open-pores and spherical morphology, which, when used as a lithium-ion battery anode, enables then to provide gravimetric and volumetric capacities of 1069.7 mAh g -1 and 686.7 mAh cm -3 , much greater than those of samples with similar composition and different morphologies. The hpMSs have good rate and cycling performances, retaining 78.5% from 100 to 1000 mA g -1 and 74.6% over 300 cycles. Using in-situ synchrotron x-ray absorption spectroscopy, the reaction pathway and phase evolution of the hpMSs are monitored observing the very small domain size and highly disordered nature of Fe x O y . Here, the reduced capacity fading relative to other conversion systems is due to the good electrical contact between the pulverized Fe x O y particles and rGO, the overall structural integrity of the hpMSs, and interconnected openporosity.

25 ENERGY STORAGE↗

NG-CT Peaker Upgrades with Bottoming Cycle: Preliminary Analysis

The National Energy Technology Laboratory (NETL) has conducted a preliminary analysis exploring a significant opportunity to increase the nation's power grid capacity and reliability. The study focuses on retrofitting under-utilized natural gas combustion turbines (NG-CTs), often called "peaker" plants, with a bottoming cycle to capture waste heat and generate additional electricity. This analysis shows that upgrading these existing assets could add approximately 26,250 MW of new power capacity across the United States. A detailed study of the PJM Interconnection, the nation's largest grid operator, confirmed the benefits of these upgrades. Key findings for the PJM region include: - A median increase in the plants' capacity factor by 17 percentage points. - A projected 36.2% median reduction in the levelized cost of electricity (LCOE) for the upgraded plants, with nearly 88% of them expected to break even. - An average reduction in the regional wholesale price of electricity by approximately 3.0% in the year 2030. - A significant boost to grid reliability, with a 46% reduction in projected Loss of Load Hours (LOLH). These findings suggest that retrofitting peaker plants is a promising and economically viable strategy to enhance grid performance, reduce electricity costs, and meet future demand without the challenges associated with building entirely new facilities.

bottoming cycle↗

Environmental influence on cracking and debonding of electrically conductive adhesives

Electrically conductive adhesives (ECAs) are starting to replace metallic solders in recent designs of photovoltaic (PV) modules. This transition represents a significant material change, and a proper understanding of the durability and reliability of the new interconnect needs to be established. This paper presents our continued work on developing a degradation model for ECA interconnects in PV modules. Here, we characterize the fracture mechanics properties of an epoxy-based ECA, for both critical and subcritical, mode I and mode II loading conditions. Emphasis is on the influence of different environmental conditions such as temperature and humidity. We use the Finite Element Method to account for residual stresses, induced by temperature changes and moisture absorption, and correct the apparent fracture toughness. We found that high moisture levels not only can weaken the fracture resistance of the ECA interconnect, but can also promote subcritical debonding at significantly lower driving forces than in dry environments.

42 ENGINEERING↗

Open V2X at ESIF: June 2015 - February 2017 (Final Report)

The University of Delaware (UD), and their industrial partners, have carried out testing, documentation, and standards development at ESIF. These activities are intended to help meet the objective of NREL's INTEGRATE program, to enable clean energy technologies to increase the hosting capacity of the grid, by providing grid services in a holistic manner using an open source, interoperable platform. In particular, the 'Open V2X at ESIF' project worked to facilitate standardization and interoperability for Electric Vehicle technologies, including battery electric vehicles and plug-in hybrid vehicles (hence EV) to provide grid services. This was done by interconnecting and testing EV and EVSE (charging station) hardware from different manufacturers, by developing standards and test protocols for standards, and by documenting new protocols to be proposed as standards. Contractor-supplied equipment used in the testing included Vehicle Smart Links (VSLs) installed in an EV and School Bus, single-phase and three-phase charging stations, and an optimizing aggregator (software running on a server, hence just 'Aggregator'). The Aggregator software was developed by U of Delaware and is now licensed to Nuvve Corp for commercial development, and licensed to NRG/EVgo for demonstrations. The Aggregator monitors capacity and operations of the EVs and EVSEs, dispatches them in response to requests, and reports their operations and metered power flow. In operation, as vehicles move, plug-in and unplug, the aggregator tracks the total capacity available within a defined jurisdiction or RTO (Regional Transmission Organization, synonym for ISO or TSO), and dispatches part or all of that capacity based on market or direct dispatch signals from a grid entity. The VSL is the data acquisition and control module in the resource itself (EVSE or EV), with rich communication between a single Optimizing Aggregator and many VSL (one in each resource). All requests and dispatch events are also logged by the aggregator to make the provision of grid power auditable. For these tests, the dispatch was typically a recorded signal, the VSL was in the EV or EVSE, and the recording of experimental performance was often carried out by the normal logging functions of the aggregator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Charging Infrastructure Technologies: Development of a Multiport, >1 MW Charging System for Medium- and Heavy-Duty Electric Vehicles

Development of a Multiport, >1 MW Charging System for Medium- and Heavy-Duty Electric Vehicles project will develop research tools for a framework to design, optimize, and demonstrate key components of a multi-port 1+ MW medium-voltage connected charging system. The objectives of this effort are to develop strategies and technologies for multi-port 1+ MW grid-connected stations to recharge MD/HD electric vehicles at fast-charging travel plazas or at fleet depots; through industry engagement, charging station utilization and load analysis, grid impacts and interconnection analysis, detailed power electronics component design and controller demonstration, site and battery charge control design and controller demonstration; and charging connector design.

1+MW charging↗

Mechanically robust, electrically conductive ultralow-density carbon nanotube-based aerogels

Disclosed here is a device comprising a porous carbon aerogel or composite thereof as an energy storage material, catalyst support, sensor or adsorbent, wherein the porous carbon aerogel comprises a network of interconnected struts comprising carbon nanotube bundles covalently crosslinked by graphitic carbon nanoparticles, wherein the carbon nanotubes account for 5 to 95 wt. % of the aerogel and the graphitic carbon nanoparticles account for 5 to 95 wt. % of the aerogel, and wherein the aerogel has an electrical conductivity of at least 10 S/m and is capable of withstanding strains of more than 10% before fracture.

25 ENERGY STORAGE↗

Land-Based Wind Market Report: 2021 Edition

The U.S. Department of Energy's 2021 edition of its land-based wind market report provides an overview of key trends in the U.S. wind power market, with a focus on 2020. You can find a report, data file and presentation on the Files tab, below. Additionally, several data visualizations are available on the Visualizations tab. Highlights of this year’s update include: -Wind comprises a growing share of electricity supply: U.S. wind power capacity grew at a record pace in 2020, with 25 billion dollars invested in 16.8 GW of capacity. Wind energy output rose to account for more than 8% of the entire nation’s electricity supply, and is more than 20% in 10 states. At least 209 GW of wind are seeking transmission interconnection; 61 GW of this capacity are offshore wind and 13 GW are hybrid plants that pair wind with storage or PV. -Wind project performance has increased over time: The average capacity factor among recently built projects was over 40%, considerably higher than projects built earlier. The highest capacity factors are seen in the interior ‘wind belt’ of the country. -Turbines continue to get larger: Improved plant performance has been driven by larger turbines mounted on taller towers and featuring longer blades. In 2010, no turbines employed blades that were 115 meters in diameter or larger, but in 2020, 91% of newly installed turbines featured such rotors. Proposed projects indicate that total turbine height will continue to rise. -Low wind turbine pricing has pushed down installed project costs over the last decade: Wind turbine prices are averaging 775–850 dollars/kW. The average installed cost of wind projects in 2020 was 1,460 dollars/kW, down more than 40% since the peak in 2010, though stable for the last three years. The lowest costs were found in Texas and the (non-ISO) West. -Wind energy prices remain low, around 20 dollars/MWh in the interior of the country: After topping out at 70 dollars/MWh for power purchase agreements (PPAs) executed in 2009, the national average price of wind PPAs has dropped. In the interior ‘wind belt’ of the country, recent pricing is around 20 dollars/MWh. In the West and East, prices tend to average 30 dollars/MWh or more. These prices, which are possible in part due to federal tax support, fall below the projected future fuel costs of gas-fired generation. -Wind PPA prices are often attractive compared to wind’s grid-system market value: The value of wind in wholesale power markets is affected by the location of wind plants, their hourly output profiles, and how those characteristics correlate with real-time electricity prices and capacity markets. The market value of wind declined in 2020, following natural gas prices lower and averaging under 15 dolalrs/MWh in ERCOT, MISO, NYISO and SPP; higher values were seen in CAISO, ISO-NE and PJM. -The average levelized cost of wind energy is down to 33 dollars/MWh: Levelized costs, which exclude the impacts of federal tax incentives, vary across time and geography, but the national average stood at 33 dollars/MWh in 2020—down substantially historically, though consistent with the previous two years. Levelized costs were lowest in ERCOT, SPP, and the (non-ISO) West. -The health and climate benefits of wind in 2020 were larger than its grid-system value, and the combination of all three far exceeds the current levelized cost of wind: Wind generation reduces power-sector emissions of carbon dioxide, nitrogen oxides, and sulfur dioxide. These reductions, in turn, provide public health and climate benefits that vary regionally, but together are economically valued at an average of 76 dollars/MWh-wind nationwide in 2020. -The domestic supply chain for wind equipment is diverse: For wind projects recently installed in the U.S., domestically manufactured content is highest for nacelle assembly (>85%), towers (60-75%), and blades and hubs (30-50%), but is much lower for most components internal to the nacelle.

17 WIND ENERGY↗

An Orderly Transition to a Transformed Electricity System

In September, 2001, the U.S. Department of Energy (DOE) sponsored a workshop to develop a roadmap on communication and control technologies for distributed energy resources. This paper summarizes the status of current smart grid related efforts, explains smart grid priorities, and describes the direction of research and development activities supported by the DOE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of technologies for welding interconnects to fifty-micron thick silicon solar cells

A program was conducted to develop technologies for welding interconnects to 50 microns thick, 2 by 2 cm solar cells. The cells were characterized with respect to electrical performance, cell thickness, silver contact thickness, contact waviness, bowing, and fracture strength. Weld schedules were independently developed for each of the three cell types and were coincidentally identical. Thermal shock tests (100 cycles from 100 C to -180 C) were performed on 16 cell coupons for each cell type without any weld joint failures or electrical degradation. Three 48 cell modules (one for each cell type) were assembled with 50 microns thick cells, frosted fused silica covers, silver clad Invar interconnectors, and Kapton substrates.

Patterson, R. E.↗

Using G4FETs as a Data Router for In-Plane Crossing of Signal Paths

Theoretical analysis and some experiments have demonstrated that siliconon- insulator (SOI) 4-gate transistors the type known as G(exp 4)FETs could be efficiently used for in-plane crossing of signal paths. Much of the effort of designing very-large-scale integrated (VLSI) circuits is focused on area-efficient routing of signals. The main source of difficulty in VLSI signal routing is the requirement to prevent crossing, in the same plane, of wires that are meant to be kept electrically insulated from each other. Consequently, it often becomes necessary to design and build VLSI circuits in multiple layers with vias (connections between conductors in different layers at selected locations). Suitable devices that would prevent, or at least sufficiently suppress, undesired electrical coupling (cross-talk) between wires crossing in the same plane would enable compact, simpler implementation complex interconnection networks with in-plane crossings that, heretofore, have not been possible in VLSI circuitry. The use of G4FETs as in-plane signal-crossing devices or routers, in combination with the use of G(exp 4)FETs as universal programmable logic gates, would create opportunities for reducing complexity in VLSI design.

Fijany, Amir↗

Photovoltaic module kit including connector assembly for non-penetrating array installation

A PV module kit for non-penetrating rooftop installation, including a plurality of PV modules and a plurality of connectors. Each of the PV modules includes a PV laminate and a frame forming a mounting region assembled thereto. The connectors include a male connector having a male fastener extending from a head, and a female connector having a female fastener assembled within a head. The heads are entirely formed of plastic. The kit provides a mounted array state including a junction at which the mounting region of at least two of the PV modules are aligned and interconnected by engagement of the male connector with the female connector. The so-formed junction is substantially electrically insulated. The plurality of connectors can further include a spacer connector including a head forming a bore sized to slidably receive the male fastener, with all of the connector heads being identical.

14 SOLAR ENERGY↗