Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Robust bidding strategy for aggregation of distributed prosumers in flexiramp market

Distributed prosumers (DPs) are the grid customers that own energy production/storage assets. Due to the flexibility and fast response of their assets, they can procure ancillary service products (ASP) in the wholesale market. An appealing ASP offered by California ISO in the real-time market (RTM) is flexiramp for which market participants do not submit direct offers, and the compensation is based on their energy opportunity costs. Here in this report, we propose a bidding strategy model for DP aggregator participation in the RTM considering energy and flexiramp. First, we develop a risk-averse optimization to determine the optimal energy and reserve product to trade in day-ahead market while considering proper amounts of flexiramp to trade in the RTM. In the RTM, to obtain optimal amounts of energy and flexiramp, the aggregator must submit hourly multi-level price-quantity energy bids for multiple RTM intervals with 15 min time-steps. On this basis, we propose a robust hourly economic bidding strategy model that determines the optimal energy bids in the RTM. We develop an adjustable robust counterpart of the model to address the RTM energy and flexiramp price uncertainties. The simulation results justify the efficacy of our proposed framework in gaining profits from the wholesale market.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-time optimization of multi-cell industrial evaporative cooling towers using machine learning and particle swarm optimization

Existing electrical generating stations must operate with greater flexibility due to increasing renewable energy penetration on the electrical grid, and many coal-fired power stations have transitioned away from baseload operation to load-following operation to aid in grid stability. In cases where multiple independently controlled cooling tower cells are used in parallel for the cooling purposes of such stations, there is an opportunity to increase plant efficiency through data-driven optimization across their full load ranges. This work presents a novel application of real-time optimization using machine learning and particle swarm optimization on a multi-cell induced-draft cooling tower servicing a coal-fired power station under variable load. This is the first work to demonstrate simultaneous optimization of a multi-cell cooling tower, in addition to using machine learning for closed-loop control on a cooling tower. A novel control configuration is presented that ensures original control logic is not adversely affected and that the overall plant process is not disrupted using only existing hardware and operational data. To verify this methodology, the 12 independent cooling tower cells are simulated in parallel using historic operating data to demonstrate the effectiveness of real-time optimization compared to current practice. An artificial neural network is trained to predict overall cooling tower power consumption using only operational data and ambient conditions with an R2 value of greater than 0.96. The real-time optimization using particle swarm yields 6.7% annual energy usage savings compared to current practices, although the extent of the real-time savings varies greatly with both plant load and environmental conditions. This is particularly significant for a variable load situation because frequent ramping typically results in reduced overall efficiency. Furthermore, this proposed AI-based solution presents an opportunity to improve the overall heat rate of a load-following coal-fired power plant without the need to perform extensive first-principles modeling or add additional hardware to the cooling tower, resulting in more resources conserved and less overall emissions per unit of electricity generated.

42 ENGINEERING↗

Scalability analysis of heavy-duty gas turbines using data-driven machine learning

With the increasing integration of variable renewable energy sources into power systems, the role of flexible power generation technologies like gas turbines (GT) in rapid grid balancing remains crucial. This sustained importance underscores the need for scaled and precise modeling of GT to ensure effective integration within evolving energy frameworks. While physics-driven GT models integrate thermodynamics, fluid dynamics, and combustion principles, they often rely on approximate mathematical representations to accommodate scaling that may not capture the actual complex dynamics for GTs and inertial effects associated to GTs with different ratings. In this study, a data-driven model is proposed using machine learning (ML) techniques to conduct GT scalability analysis and performance evaluation with high accuracy. The ML model, trained on data from various operating conditions and performance parameters, aims to uncover intricate relationships and patterns, resembling GT characteristics at different scales (ratings). The model is developed to capture complex system interaction and to adapt to changing operational scenarios at different capacities, providing valuable insights of power system dynamics. In this study, the real-time digital simulator platform was employed to generate training data for the ML model and assess its dynamic characteristics. The ultimate objective was to develop a detailed modeling framework based on governing equations and data-driven ML capable of predicting key performance indicators, in thermal systems such as GTs, including power output, speed, fuel consumption, and exhaust temperature under diverse operating conditions at different scales. The developed ML framework demonstrated high accuracy, with mean relative errors for GT power prediction, reference speed, exhaust temperature, and compressor pressure ratio (CPR) parameters consistently below 0.1% across typical load fluctuation scenarios. Maximum deviations were limited to approximately 0.5 K for exhaust temperature and 0.009 for CPR, underscoring the model’s ability to replicating dynamic GT behavior with high precision. The adaptability of the ML model enables its application across diverse operational conditions and its extension to other thermal systems. By leveraging advanced ML techniques, this study presents a robust and scalable modeling framework that enhances GT simulation precision, facilitating improved integration into evolving power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An integrated data analysis tool for improving measurements on the MST RFP

Many plasma diagnostics contain complementary information. For example, the double-foil soft x-ray system (SXR) and the Thomson Scattering diagnostic (TS) on the Madison Symmetric Torus both measure electron temperature. The complementary information from these diagnostics can be combined using a systematic method based on integrated data analysis techniques, leading to more accurate and sensitive results. An integrated data analysis tool based on Bayesian probability theory was able to estimate electron temperatures that are consistent with both the SXR and TS diagnostics and more precise than either. A Markov Chain Monte Carlo analysis to increase the flexibility of the tool was implemented and benchmarked against a grid search method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comparison of Eulerian and semi-Lagrangian approaches for modeling stream water quality

This paper describes and compares some of the advantages and limitations of Eulerian and Lagrangian approaches to water quality modeling and introduces a mixed Eulerian-Lagrangian (or semi-Lagrangian) methodology that captures the strengths of both approaches. The semi-Lagrangian modeling approach is applied to advection-dominated rivers, and flexibly ensures unconditional stability for all time step durations and grid segmentations. The semi-Lagrangian modeling approach is demonstrated by applying it to estimate the dissolved oxygen concentrations in the Sava River in Slovenia, focusing on aspects of the methodology and findings that would be of broad interest to managers of water quality in fluvial water bodies. Results of comparisons of the semi-Lagrangian model with the Eulerian-based QUAL2K model in steady and non-steady scenarios demonstrate that while both models are fully capable of producing satisfactory results when optimally configured, the semi-Lagrangian approach offers accuracy and stability without sensitivity to the interaction of time step size and computational grid segmentation scheme.

Sava River↗

Impacts of climate change on subannual hydropower generation: a multi-model assessment of the United States federal hydropower plant

Abstract Hydropower is a low-carbon emission renewable energy source that provides competitive and flexible electricity generation and is essential to the evolving power grid in the context of decarbonization. Assessing hydropower availability in a changing climate is technically challenging because there is a lack of consensus in the modeling representation of key dynamics across scales and processes. Focusing on 132 US federal hydropower plants, in this study we evaluate the compounded impact of climate and reservoir-hydropower models’ structural uncertainties on monthly hydropower projections. In particular, instead of relying on one single regression-based hydropower model, we introduce another conceptual reservoir operations-hydropower model in the assessment framework. This multi-model assessment approach allows us to partition uncertainties associated with both climate and hydropower models for better clarity. Results suggest that while at least 70% of the uncertainties at the annual scale and 50% at the seasonal scale can be attributed to the choice of climate models, up to 50% of seasonal variability can be attributed to the choice of hydropower models, particularly in regions over the western US where the reservoir storage is substantial. The analysis identifies regions where multi-model assessments are needed and presents a novel approach to partition uncertainties in hydropower projections. Another outcome includes an updated evaluation of Coupled Model Intercomparison Project Phase 5 (CMIP5)-based federal hydropower projection, at the monthly scale and with a larger ensemble, which can provide a baseline for understanding future assessments based on CMIP6 and beyond.

54 ENVIRONMENTAL SCIENCES↗

Emulating galaxy clustering and galaxy–galaxy lensing into the deeply non-linear regime: methodology, information, and forecasts

The combination of galaxy–galaxy lensing (GGL) with galaxy clustering is one of the most promising routes to determining the amplitude of matter clustering at low redshifts. Here, we show that extending clustering+GGL analyses from the linear regime down to |${\sim } 0.5 \, h^{-1}$| Mpc scales increases their constraining power considerably, even after marginalizing over a flexible model of non-linear galaxy bias. Using a grid of cosmological N -body simulations, we construct a Taylor-expansion emulator that predicts the galaxy autocorrelation ξ gg ( r ) and galaxy-matter cross-correlation ξ gm ( r ) as a function of σ 8 , Ω m , and halo occupation distribution (HOD) parameters, which are allowed to vary with large-scale environment to represent possible effects of galaxy assembly bias. We present forecasts for a fiducial case that corresponds to BOSS LOWZ galaxy clustering and SDSS-depth weak lensing (effective source density ~0.3 arcmin -2 ). Using tangential shear and projected correlation function measurements over |$0.5 \le r_\mathrm{ p} \le 30 \, h^{-1}$| Mpc yields a 2 per cent constraint on the parameter combination |$\sigma _8\Omega _\mathrm{ m}^{0.6}$| , a factor of two better than a constraint that excludes non-linear scales ( |$r_\mathrm{ p} \gt 2 \, h^{-1}$| Mpc, |$4 \, h^{-1}$| Mpc for γ t , |$w$| p ). Much of this improvement comes from the non-linear clustering information, which breaks degeneracies among HOD parameters. Increasing the effective source density to 3 arcmin -2 sharpens the constraint on |$\sigma _8\Omega _\mathrm{ m}^{0.6}$| by a further factor of two. With robust modelling into the non-linear regime, low-redshift measurements of matter clustering at the 1-per cent level with clustering+GGL alone are well within reach of current data sets such as those provided by the Dark Energy Survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Large-scale Hydrogen Storage – Risk Assessment Seattle City Light and Port of Seattle [Abstract]

This CRADA presents the strategy that Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL) will take to support Seattle City Light (SCL), and the Port of Seattle (Port) in performing a risk assessment of large-scale hydrogen storage. Risk assessment is often used to ensure that adequate measures are taken to protect workers and the public, the environment, infrastructure, and assets. A detailed risk assessment can also be used to direct funding and upgrades, to specific components and sub-systems in order to mitigate risks to the larger system. In this way risk assessments are often employed as a part of a larger risk management strategy, with the goal of minimizing the occurrence of hazards and to identify means to limit their consequences. Risk assessment is often used to engage and inform regulators, and to communicate how specific regulations are being met. However, it is important to note that the proposed work is not intended for SCL and the Port to use in order to gain regulatory acceptance for their proposed activities. The work performed as a part of this effort will be a preliminary risk assessment for early-stage component and system designs and should be considered research and development (R&D). As such, the proposed work will be performed to a quality level and design maturity consistent with R&D and is not considered appropriate for final safety analysis and regulatory compliance purposes. Previous and on-going work at SCL and the Port demonstrated the utility of deploying hydrogen systems at the Port. The deployment of hydrogen at the Port is a part of a larger vision of using hydrogen to address a range of issues for SCL and the Port. These include large-scale fueling of MD/HD vehicles, cargo-handling equipment (CHE), and harbor vessels to reduce emissions; support of adjacent LD vehicles; support of critical port operations during extreme events (i.e., resiliency); deferral of more capital- and time-intensive electrical distribution system upgrades while still supporting evolving port operations and decarbonization efforts; facilitating electrification by establishing energy storage as a grid resource, starting at strategic port locations; creation of a flexible market resource that can be used by SCL to generate revenue via arbitrage; support of planned future maritime operations that involve heavy use of hydrogen for ocean-going vessels; and future end-use applications involving natural gas pipeline hydrogen injection. Ultimately, the success of these activities is underpinned by the deployed storage capacity. Large-scale deployment of hydrogen systems will require hydrogen storage at a scale that has not been demonstrated. In addition, the ideal location for such multi-use systems is near the end user which will often necessitate deploying into urban and/or industrial areas. A detailed risk assessment using the Port as a test case is necessary to ensure the deployment of large-scale hydrogen is successful. Many technologies have been proposed for hydrogen storage; however, these technologies need to be analyzed as they apply to an actual site. The physical infrastructure and hydrogen use cases for the Port will be analyzed, and a risk assessment for compressed hydrogen, liquified hydrogen, and Liquid Organic Hydrogen Carrier (LOHC) storage will be performed. These risk assessments will be useful for understanding how each of these technologies would perform in terms of facility and public safety. The operating states of the proposed hydrogen systems at the Port will be analyzed and incorporated into the storage risk assessment. Scalability will also be analyzed to understand how future port uses would affect the overall risk assessment. Finally, using the risk assessment as a tool to inform engagement and to gain stakeholder acceptance will be explored.

08 HYDROGEN↗

Near-Term Electricity Requirement and Emission Implications for Sustainable Aviation Fuel Production with CO 2 -to-Fuels Technologies

Aviation contributed approximately 10% of the U.S. transportation sector's greenhouse gas (GHG) emissions and about 3% of the nation's total GHG production before the coronavirus disease (COVID-19) pandemic (EPA 2022). Unlike the ground transportation sector, which can be decarbonized by using batteries and hydrogen fuel cell powertrain technologies, the technical and economic challenges of aviation electrification open the opportunity for CO 2 utilization (CO2U) using clean power sources. The U.S. government set a goal to produce 3 billion gallons per year of sustainable aviation fuels (SAF) by 2030 and scale up the production to 35 billion gallons per year by 2050 (Bioenergy Technologies Office 2022). In this report, we examine three potential locations, in California, Iowa, and Louisiana, for SAF production using two production pathways that are expected to be available by 2030. We analyze the electricity cost to satisfy 10% of the SAF production potential for the select locations. Specifically, we consider (1) retail electricity cost from the default local utility in each location; (2) physical power purchase agreement (PPA) for renewable power and battery storage hybrid systems with preset prices; (3) financial PPA from a dedicated renewable plant; and (4) estimated real-time pricing (RTP) from the wholesale power market with utility delivery adders. Retail rates are available for the three potential locations; however, the developer should negotiate with the local utility in Iowa for new tariff riders, because the load of the proposed SAF plant (1.4 GW) is significantly higher than the current industrial tariff structure requirement (200 kW). The developers are not able to claim federal credits (i.e., the Inflation Reduction Act of 2022) when sourcing electricity from local utilities. Developers could consider prioritizing physical and financial PPAs as purchase options. While physical PPAs can be imported out of state, this structure imposes availability issues as developers must locate in the same electricity grid regions. Financial PPAs do not have the same location restrictions and provide the same cost savings as physical PPAs, but financial PPAs impose financial risks in the event of system curtailment and grid interruption. RTPs are available for customers in California with flexible load and hourly load management capability; however, utilities in our studied regions in Louisiana and Iowa only offer time-of-use and curtailment programs to incentivize lower energy usage in peak hours. These utilities do not currently offer RTP programs, and the developer may need to have further negotiations with the local utilities to access RTP programs. The results show that purchased electricity prices may range from 2.6 cents/kWh to 7.1 cents/kWh for the three studied plants.

02 PETROLEUM↗

Advancing Concentrating Solar Thermal Modeling Using System Advisor Model (SAM)

Concentrating solar thermal (CST) technologies play a critical role in enabling dispatchable power and high-temperature industrial heat applications. Accurate and flexible modeling tools are essential for evaluating system performance, guiding technology research and development, and informing investment decisions. The National Laboratory of the Rockies's System Advisor Model (SAM) is a widely used techno-economic simulation platform for CST systems, providing detailed performance and financial modeling capabilities for multiple CST system configurations. SAM integrates physics-based performance models with financial analysis to simulate the behavior of complex energy systems under realistic operating conditions. For CST technologies (including tower, parabolic trough, and linear Fresnel), SAM enables hourly simulations using site-specific weather data that ensure feasible operating conditions and convergence of mass and energy between core system components (i.e., solar field, receiver, thermal energy storage, and power cycle). These capabilities allow researchers and developers to evaluate annual energy production, capacity factors, levelized cost of energy (LCOE), and system dispatch strategies. A key advantage of SAM lies in its flexibility for parametric analysis and large-scale computational studies. Users can vary system design parameters such as heliostat field layout, receiver dimensions, thermal energy storage capacity, power block sizing, and installation cost assumptions to investigate their impact on system performance and financial metrics. When combined with automated scripting through LK, SDKTool, or Python interfaces, SAM enables high-throughput simulation workflows that support sensitivity analysis, technology benchmarking, and optimization studies. These approaches are particularly valuable for next-generation CST concepts, where design spaces are large and system interactions are complex. Another important capability of SAM is its support for dispatch optimization and thermal energy storage modeling, which are central to the value proposition of CST technologies. The ability to simulate integrated storage and flexible power generation allows researchers to explore strategies that maximize grid value, improve capacity utilization, and enhance integration with variable resources such as photovoltaic and wind generation. This poster will present an overview of SAM's thermal system modeling capabilities including concentrating solar. Additionally, we will highlight new feature developments including: 1) implementing Google's OR-Tools optimization platform for faster and more robust dispatch optimization, 2) developing a new power load following controller for modeling behind-the-meter applications, 3) enabling direct modeling of CSP-PV hybrid systems with the inclusion of battery storage, and 4) developing a multi-receiver falling particle Gen3 system model.

14 SOLAR ENERGY↗

A multidomain global modeling technique for analysis of Space Shuttle main engine

A multidomain global modeling technique is presented. The purpose of this multidomain methodology is to simultaneously analyze the three-dimensional compressible flow field in Space Shuttle main engine components. This technique provides flexibility and modularity for individual domain and also simplifies the grid generation task for each domain. A two-way coupling procedure is adopted for exchanging interface boundary conditions. This algorithm which requires that the adjacent domains share an overlapping grid slab, is fully conservative and implicit. For non-matching grid systems and for non-overlapping interfaces, an interpolation and/or extrapolation procedure is used when transferring the interface boundary conditions at the adjacent domains. To maintain overall conservation, a flux correction method is subsequently used. The coupling procedure was verified by modeling several geometries with features similar to SSME components. Satisfactory results for all test cases were obtained. Finally, this algorithm has been applied to the SSME flow simulation.

Tam, L. T.↗

Comprehensive Solutions for Integration of Solar Resources into Grid Operations

The need for proactive closed-loop integration of uncertainty information into system operations and probability-based controls is widely recognized, but rarely implemented in system operations. Proactive integration for this project means that the information concerning expected uncertainty ranges for net load and balancing requirements, including required balancing capacity, ramping and ramp duration characteristics, will be fed back into the generation commitment and dispatch algorithms to modify their performance so that potential shortages of these characteristics can be prevented. This basic, yet important, premise is the motivating factor for this project. The achieved project goal is to demonstrate the benefit of such a system. The project quantifies future uncertainties, predicts additional system balancing needs including the prediction intervals for capacity and ramping requirements of future dispatch intervals, evaluates the impacts of uncertainties on transmission including the risk of overloads and voltage problems, and explores opportunities for intra-hour generation adjustments helping to provide more flexibility for system operators. The resulting benefits culminate in more reliable grid operation in the face of increased system uncertainty and variability caused by solar power. The project identifies that solar power does not require special separate penetration level restrictions or penalization for its intermittency. Ultimately, the collective consideration of all sources of intermittency distributed over a wide area unified with the comprehensive evaluation of various elements of balancing process, i.e. capacity, ramping, and energy requirements, help system operators more robustly and effectively balance generation against load and interchange. This project showed that doing so can facilitate more solar and other renewable resources on the grid without compromising reliability and control performance. Efforts during the project included developing and integrating advanced probabilistic solar forecasts, including distributed PV forecasts, into closed –loop decision making processes. Additionally, new uncertainty quantifications methods and tools for the direct integration of uncertainty and variability information into grid operations at the transmission and distribution levels were developed and tested. During Phase 1, project work focused heavily on the design, development and demonstration of a set of processes and tools that could reliably and efficiently incorporate solar power into California’s grid operations. In Phase 2, connectivity between the ramping analysis tools and market applications software were completed, multiple dispatch scenarios demonstrated a successful reduction of overall uncertainty and an analysis to quantify increases in system operator reliability, and the transmission and distribution system uncertainty prediction tool was introduced to system operation engineers in a live webinar. The project met its goals, the experiments prove the advancements to methods and tools, when working together, are beneficial to not only the California Independent System Operator, but the benefits are transferable to other system operators in the United States.

14 SOLAR ENERGY↗

Flexibility in 21st Century Power Systems

Flexibility of operation—the ability of a power system to respond to change in demand and supply—is a characteristic of all power systems. Flexibility is especially prized in twenty-first century power systems, with higher levels of grid-connected variable renewable energy (primarily, wind and solar). This paper summarizes the analytic frameworks that have emerged to measure this characteristic and distills key principles of flexibility for policy makers.

21CPP↗

Parametric Geometry, Structured Grid Generation, and Initial Design Study for REST-Class Hypersonic Inlets

Computational design and analysis of three-dimensional hypersonic inlets with shape transition has been a significant challenge due to the complex geometry and grid required for three-dimensional viscous flow calculations. Currently, the design process utilizes an inviscid design tool to produce initial inlet shapes by streamline tracing through an axisymmetric compression field. However, the shape is defined by a large number of points rather than a continuous surface and lacks important features such as blunt leading edges. Therefore, a design system has been developed to parametrically construct true CAD geometry and link the topology of a structured grid to the geometry. The Adaptive Modeling Language (AML) constitutes the underlying framework that is used to build the geometry and grid topology. Parameterization of the CAD geometry allows the inlet shapes produced by the inviscid design tool to be generated, but also allows a great deal of flexibility to modify the shape to account for three-dimensional viscous effects. By linking the grid topology to the parametric geometry, the GridPro grid generation software can be used efficiently to produce a smooth hexahedral multiblock grid. To demonstrate the new capability, a matrix of inlets were designed by varying four geometry parameters in the inviscid design tool. The goals of the initial design study were to explore inviscid design tool geometry variations with a three-dimensional analysis approach, demonstrate a solution rate which would enable the use of high-fidelity viscous three-dimensional CFD in future design efforts, process the results for important performance parameters, and perform a sample optimization.

Ferlemann, Paul G.↗

Bulk Power System Flow Control

On July 28, 2023, the Federal Energy Regulatory Commission (FERC) issued Order Number 2023, targeting an improved generation-interconnection process in the United States. FERC Order No. 2023 requires transmission providers to evaluate transmission technologies, other than network expansion, that could provide system improvements and help expand bulk-power system capacity. Transmission providers must consider technologies that would fall under the category of Grid Enhancing Technologies (GETs), which provide capacity-expansion options other than conventional transmission expansion.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Virtual Synchronous Generator Control of Multi-port Autonomous Reconfigurable Solar Plants (MARS)

Multi-port autonomous reconfigurable solar power plant (MARS) is an integrated concept for integration of solar photovoltaic (PV) and energy storage systems (ESS) to transmission alternating current (ac) grid and high-voltage direct current (HVdc) links. The integrated development incorporates advanced control methods to provide enhanced grid ancillary services such as fast frequency responses and dynamic voltage support. In this paper, the virtual synchronous generator (VSG) control algorithm of MARS is discussed. The proposed VSG-based control enables enhanced synthetic inertial response and flexible frequency response characteristics of hybrid PV and ESS power plants in accordance with grid ancillary service requirements. Multi-port power electronics interface allows controlled emergency power support from MARS to local transmission ac grid and remote grid through the HVdc link. The performance of VSG control is validated using a reduced-order model of MARS in Simulink. Methods for estimating grid ancillary service capabilities of MARS are also discussed.

Pan, Jiuping↗

Community-scale interaction of energy efficiency and demand flexibility in residential buildings

Demand-side management (DSM) strategies, including energy efficiency (EE) and demand flexibility (DF), contribute to cost-effective operation of the electricity grid. From a system-level perspective, such programs reduce costs, enhance reliability, and reduce network issues. Similarly, DSM programs help participating customers reduce utility bills while maintaining occupant comfort. Understanding the relationship between EE and DF is key to realizing the full potential of DSM programs. In this study, we modeled an all-electric residential community based on a 498-home community that is planned for construction in Fort Collins, Colorado in the United States. We used this community model to study the relationship between different EE measures, including building envelope upgrades and smart appliances, and DF enabled by a home energy management system (HEMS) responding to a time-varying tariff. Various EE levels in the homes – code-minimum, zero energy ready, and even higher levels of envelope efficiency – were simulated. DF is enabled by the HEMS, which coordinates behind-the-meter resources, including flexible building loads, PV, and home battery systems, to minimize utility bills while maintaining occupant comfort. When comparing to the code-minimum homes, EE upgrades alone reduce HVAC energy use during peak hours by up to 50% and the HVAC utility bill by up to $312/year. With the addition of HEMS, the average daily peak demand can be reduced by up to 0.58 MW or 1.2 kW/home in the higher envelope efficiency homes. The combination of EE upgrades, HEMS, and home battery systems is expected to save homeowners up to $590/year while increasing community load flexibility. However, HEMS and home battery systems are less effective in increasing the DF in the more efficient homes due to the lower load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗