Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Ultra-short channel GaN high electron mobility transistor-like Gunn diode with composite contact

We present a numerical analysis on an ultra-short channel AlGaN/GaN HEMT-like planar Gunn diode based on the velocity-field dependence of two-dimensional electron gas (2-DEG) channel accounting for the ballistic electron acceleration and the inter-valley transfer. In particular, we propose a Schottky-ohmic composite contact instead of traditional ohmic contact for the Gunn diode in order to significantly suppress the impact ionization at the anode side and shorten the “dead zone” at the cathode side, which is beneficial to the formation and propagation of dipole domain in the ultra-short 2-DEG channel and the promotion of conversion efficiency. The influence of the surface donor-like traps on the electron domain in the 2-DEG channel is also included in the simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Signatures of clumpy dark matter in the global 21 cm background signal

We examine the extent to which the self-annihilation of supersymmetric neutralino dark matter, as well as light dark matter, influences the rate of heating, ionization, and Lyman-{alpha} pumping of interstellar hydrogen and helium and the extent to which this is manifested in the 21 cm global background signal. We fully consider the enhancements to the annihilation rate from dark matter halos and substructures within them. We find that the influence of such structures can result in significant changes in the differential brightness temperature, {delta}T{sub b}. The changes at redshifts z<25 are likely to be undetectable due to the presence of the astrophysical signal; however, in the most favorable cases, deviations in {delta}T{sub b}, relative to its value in the absence of self-annihilating dark matter, of up to {approx_equal}20 mK at z=30 can occur. Thus we conclude that, in order to exclude these models, experiments measuring the global 21 cm signal, such as EDGES and CORE, will need to reduce the systematics at 50 MHz to below 20 mK.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-D-209-01: Can Fluoroscopic Air-Kerma Rates Be Reliably Measured with Solid-State Meters?

Purpose: Ionization chambers remain the standard for calibration of air-kerma rate measuring devices. Despite their strong energy-dependent response, solid state radiation detectors are increasingly used, primarily due to their efficiency in making standardized measurements. To test the reliability of these devices in measuring air-kerma rates, we compared ion chambers measurements with solid-state measurements for various mobile fluoroscopes operated at different beam qualities and air-kerma rates. Methods: Six mobile fluoroscopes (GE OEC models 9800 and 9900) were used to generate test beams. Using various field sizes and dose rate controls, copper attenuators and a lead attenuator were placed at the image receptor in varying combinations to generate a range of air-kerma rates. Air-kerma rates at 30 centimeters from the image receptors were measured using two 6-cm{sup 3} ion chambers with electrometers (Radcal, models 1015 and 9015) and two with solid state detectors (Unfors Xi and Raysafe X2). No error messages occurred during measurements. However, about two months later, one solid-state device stopped working and was replaced by the manufacturer. Two out of six mobile fluoroscopic units were retested with the replacement unit. Results: Generally, solid state and ionization chambers agreed favorably well, with two exceptions. Before replacement of the detector, the Xi meter when set in the “RF High” mode deviated from ion chamber readings by factors of 2 and 10 with no message indicating error in measurement. When set in the “RF Low” mode, readings were within −4% to +3%. The replacement Xi detector displayed messages alerting the user when settings were not compatible with air-kerma rates. Conclusion: Air-kerma rates can be measured favorably well using solid-state devices, but users must be aware of the possibility that readings can be grossly in error with no discernible indication for the deviation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling the gain of inner-shell X-ray laser transitions in neon, argon, and copper driven by X-ray free electron laser radiation using photo-ionization and photo-excitation processes

Using an X-ray free electron laser (XFEL) at 960 eV to photo-ionize the 1s electron in neutral neon followed by lasing on the 2p-1s transition in singly-ionized neon, an inner-shell X-ray laser was demonstrated at 849 eV in singly-ionized neon gas several years ago. It took decades to demonstrate this scheme, because it required a very strong X-ray source that could photo-ionize the 1s (K shell) electron in neon on a timescale comparable to the intrinsic Auger lifetime in neon of 2 fs. In this paper, we model the neon inner shell X-ray laser under similar conditions to those used in the XFEL experiments at the SLAC Linac Coherent Light Source (LCLS), and show how we can improve the efficiency of the neon laser and reduce the drive requirements by tuning the XFEL to the 1s-3p transition in neutral neon in order to create gain on the 2p-1s line in neutral neon. We also show how the XFEL could be used to photo-ionize L-shell electrons to drive gain on n = 3–2 transitions in singly-ionized Ar and Cu plasmas. These bright, coherent, and monochromatic X-ray lasers may prove very useful for doing high-resolution spectroscopy and for studying non-linear process in the X-ray regime.

36 MATERIALS SCIENCE↗

Breakdown assisted by a novel electron drift injection in the J-TEXT tokamak

A novel electron drift injection (EDI) system aiming to improve breakdown behavior has been designed and constructed on the Joint Texas EXperiment Tokamak Tokamak. Electrons emitted by the system undergo the E×B drift, ∇B drift and curvature drift in sequence in order to traverse the confining magnetic field. A local electrostatic well, generated by a concave-shaped plate biased more negative than the cathode, is introduced to interrupt the emitted electrons moving along the magnetic field line (in the parallel direction) in an attempt to bring an enhancement of the injection efficiency and depth. A series of experiments have demonstrated the feasibility of this method, and a penetration distance deeper than 9.5 cm is achieved. Notable breakdown improvements, including the reduction of breakdown delay and average loop voltage, are observed for discharges assisted by EDI. The lower limit of successfully ionized pressure is expanded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation of normal-conducting rf cavities in multi-Tesla magnetic fields for muon ionization cooling: A feasibility demonstration

Ionization cooling is the preferred method for producing bright muon beams. This cooling technique requires the operation of normal conducting, radio-frequency (rf) accelerating cavities within the multi-tesla fields of dc solenoid magnets. Under these conditions, cavities exhibit increased susceptibility to rf breakdown, which can damage cooling channel components and imposes limits on channel length and transmission efficiency. We report, for the first time, stable high-vacuum, normal-conducting cavity operation at gradients of 50 MV / m in an external magnetic field of three tesla, through the use of beryllium cavity elements. This eliminates a significant technical risk that has previously been inherent in ionization cooling channel designs.

43 PARTICLE ACCELERATORS↗

Drug discovery efforts at George Mason University

With over 39,000 students, and research expenditures in excess of $200 million, George Mason University (GMU) is the largest R1 (Carnegie Classification of very high research activity) university in Virginia. Mason scientists have been involved in the discovery and development of novel diagnostics and therapeutics in areas as diverse as infectious diseases and cancer. Below are highlights of the efforts being led by Mason researchers in the drug discovery arena. To enable targeted cellular delivery, and non-biomedical applications, Veneziano and colleagues have developed a synthesis strategy that enables the design of self-assembling DNA nanoparticles (DNA origami) with prescribed shape and size in the 10 to 100 nm range. The nanoparticles can be loaded with molecules of interest such as drugs, proteins and peptides, and are a promising new addition to the drug delivery platforms currently in use. The investigators also recently used the DNA origami nanoparticles to fine tune the spatial presentation of immunogens to study the impact on B cell activation. These studies are an important step towards the rational design of vaccines for a variety of infectious agents. To elucidate the parameters for optimizing the delivery efficiency of lipid nanoparticles (LNPs), Buschmann, Paige and colleagues have devised methods for predicting and experimentally validating the pKa of LNPs based on the structure of the ionizable lipids used to formulate the LNPs. These studies may pave the way for the development of new LNP delivery vehicles that have reduced systemic distribution and improved endosomal release of their cargo post administration. To better understand protein-protein interactions and identify potential drug targets that disrupt such interactions, Luchini and colleagues have developed a methodology that identifies contact points between proteins using small molecule dyes. The dye molecules noncovalently bind to the accessible surfaces of a protein complex with very high affinity, but are excluded from contact regions. When the complex is denatured and digested with trypsin, the exposed regions covered by the dye do not get cleaved by the enzyme, whereas the contact points are digested. The resulting fragments can then be identified using mass spectrometry. The data generated can serve as the basis for designing small molecules and peptides that can disrupt the formation of protein complexes involved in disease processes. For example, using peptides based on the interleukin 1 receptor accessory protein (IL-1RAcP), Luchini, Liotta, Paige and colleagues disrupted the formation of IL-1/IL-R/IL-1RAcP complex and demonstrated that the inhibition of complex formation reduced the inflammatory response to IL-1B. Working on the discovery of novel antimicrobial agents, Bishop, van Hoek and colleagues have discovered a number of antimicrobial peptides from reptiles and other species. DRGN-1, is a synthetic peptide based on a histone H1-derived peptide that they had identified from Komodo Dragon plasma. DRGN-1 was shown to disrupt bacterial biofilms and promote wound healing in an animal model. The peptide, along with others, is being developed and tested in preclinical studies. Other research by van Hoek and colleagues focuses on in silico antimicrobial peptide discovery, screening of small molecules for antibacterial properties, as well as assessment of diffusible signal factors (DFS) as future therapeutics. The above examples provide insight into the cutting-edge studies undertaken by GMU scientists to develop novel methodologies and platform technologies important to drug discovery.

59 BASIC BIOLOGICAL SCIENCES↗

Hydrophobic Treatment Enabling Analysis of Wettable Surfaces using a Liquid Microjunction Surface Sampling Probe/Electrospray Ionization-Mass Spectrometry System

An aerosol application procedure involving one or more commercially available silicone based products was developed to create hydrophobic surfaces that enable analysis of otherwise wettable, absorbent surfaces using a liquid microjunction surface sampling probe/electrospray ionization mass spectrometry system. The treatment process resulted in a hydrophobic surface that enabled formation of the requisite probe - to - surface liquid microjunction for sampling and allowed efficient extraction of the analytes from the surface, but did not contribute significant chemical background in the mass spectra. The utility of this treatment process was demonstrated with the treatment of wettable high performance thin layer chromatography plates, post plate development, and their subsequent analysis with the sampling probe. The surface treatment process for different surface types was described and explained and the effectiveness of the treatment and subsequent analysis was illustrated using alkaloids from Goldenseal (Hydrastis canadensis) root separated on a normal phase silica gel 60 F254S plate and peptides from protein tryptic digests separated on a Protochrom HPTLC Silica gel 60 F254S plate and a Protochrom HPTLC cellulose sheet. This simple surface treatment process significantly expands the analytical surfaces that can be analyzed with the liquid microjunction surface sampling probe, and therefore, also expands the analytical utility of this liquid extraction based surface sampling approach.

Walworth, Matthew J↗

Ab-initio study of donor-acceptor codoping for n-type CuO

Single n-type dopant in CuO has either a deep donor level or limited solubility, inefficient in generating free electrons. We have performed ab-initio study of the donor-acceptor codoping to obtain n-type CuO. Our results show that N codoping can slightly improve the donor level of Zr and In by forming shallower n-type complexes (Zr{sub Cu}-N{sub O} and 2In{sub Cu}-N{sub O}), but their formation energies are too high to be realized in experiments. However, Li codoping with Al and Ga is found to be relatively easy to achieve. 2Al{sub Cu}-Li{sub Cu} and 2Ga{sub Cu}-Li{sub Cu} have shallower donor levels than single Al and Ga by 0.14 eV and 0.08 eV, respectively, and their formation energies are reasonably low to act as efficient codopants. Moreover, Li codoping with both Al and Ga produce an empty impurity band just below the host conduction band minimum, which may reduce the donor ionization energy at high codoping concentrations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NOTHING TO HIDE: AN X-RAY SURVEY FOR YOUNG STELLAR OBJECTS IN THE PIPE NEBULA

We have previously analyzed sensitive mid-infrared observations to establish that the Pipe Nebula (PiN) has a very low star formation efficiency. That study focused on young stellar objects (YSOs) with excess infrared emission (i.e., protostars and pre-main-sequence stars with disks), however, and could have missed a population of more evolved pre-main-sequence stars or Class III objects (i.e., young stars with dissipated disks that no longer show excess infrared emission). Evolved pre-main-sequence stars are X-ray bright, so we have used ROSAT All-Sky Survey data to search for diskless pre-main-sequence stars throughout the PiN. We have also analyzed archival XMM-Newton observations of three prominent areas within the Pipe: Barnard 59 (B 59), containing a known cluster of YSOs; Barnard 68, a dense core that has yet to form stars; and the Pipe molecular ring, a high-extinction region in the bowl of the Pipe. We also characterize the X-ray properties of YSOs in B 59. The ROSAT and XMM-Newton data provide no indication of a significant population of more evolved pre-main-sequence stars within the Pipe, reinforcing our previous measurement of the Pipe's very low star formation efficiency.

79 ASTRONOMY AND ASTROPHYSICS↗

THERMAL AND RADIATIVE ACTIVE GALACTIC NUCLEUS FEEDBACK HAVE A LIMITED IMPACT ON STAR FORMATION IN HIGH-REDSHIFT GALAXIES

The effects of active galactic nuclei (AGNs) on their host galaxies depend on the coupling between the injected energy and the interstellar medium (ISM). Here, we model and quantify the impact of long-range AGN ionizing radiation—in addition to the often considered small-scale energy deposition—on the physical state of the multi-phase ISM of the host galaxy and on its total star formation rate (SFR). We formulate an AGN spectral energy distribution matched with observations, which we use with the radiative transfer (RT) code Cloudy to compute AGN ionization in a simulated high-redshift disk galaxy. We use a high-resolution (∼6 pc) simulation including standard thermal AGN feedback and calculate RT in post-processing. Surprisingly, while these models produce significant AGN-driven outflows, we find that AGN ionizing radiation and heating reduce the SFR by a few percent at most for a quasar luminosity (L {sub bol} = 10{sup 46.5} erg s{sup –1}). Although the circumgalactic gaseous halo can be kept almost entirely ionized by the AGN, most star-forming clouds (n ≳ 10{sup 2} {sup –} {sup 3} cm{sup –3}) and even the reservoirs of cool atomic gas (n ∼ 0.3-10 cm{sup –3})—which are the sites of future star formation (SF; 100-200 Myr), are generally too dense to be significantly affected. Our analysis ignores any absorption from a putative torus, making our results upper limits on the effects of ionizing radiation. Therefore, while the AGN-driven outflows can remove substantial amounts of gas in the long term, the impact of AGN feedback on the SF efficiency in the interstellar gas in high-redshift galaxies is marginal, even when long-range radiative effects are accounted for.

79 ASTRONOMY AND ASTROPHYSICS↗

Contrasting behavior of covalent and molecular carbon allotropes exposed to extreme ultraviolet and soft x-ray free-electron laser radiation

All carbon materials, e.g., amorphous carbon (a-C) coatings and C 60 fullerene thin films, play an important role in short-wavelength free-electron laser (FEL) research motivated by FEL optics development and prospective nanotechnology applications. We investigate responses of a-C and C 60 layers to the extreme ultraviolet (SPring-8 Compact SASE Source in Japan) and soft x-ray (free-electron laser in Hamburg) free-electron laser radiation by Raman spectroscopy, differential interference contrast, and atomic force microscopy. A remarkable difference in the behavior of covalent (a-C) and molecular ( C 60 ) carbonaceous solids is demonstrated under these irradiation conditions. Low thresholds for ablation of a fullerene crystal (estimated to be around 0.15 eV/atom for C 60 vs 0.9 eV/atom for a-C in terms of the absorbed dose) are caused by a low cohesive energy of fullerene crystals. An efficient mechanism of the removal of intact C 60 molecules from the irradiated crystal due to Coulomb repulsion of fullerene-cage cation radicals formed by the ionizing radiation is revealed by a detailed modeling.

36 MATERIALS SCIENCE↗

First-principles ionized-impurity scattering and charge transport in doped materials

Scattering of carriers with ionized impurities governs charge transport in doped semiconductors. However, electron interactions with ionized impurities cannot be fully described with quantitative first-principles calculations, so their understanding relies primarily on simplified models. Here we show an ab initio approach to compute the interactions between electrons and ionized impurities or other charged defects. It includes the short- and long-range electron-defect (e-d) interactions on equal footing and allows for efficient interpolation of the e-d matrix elements. Here we combine the e-d and electron-phonon interactions in the Boltzmann transport equation to compute the carrier mobilities in doped silicon over a wide range of temperature and doping concentrations, seamlessly spanning the defect- and phonon-limited transport regimes. The individual contributions of the defect- and phonon-scattering mechanisms to the carrier relaxation times and mean-free paths are analyzed. Our method provides a powerful tool to study electronic interactions in doped materials. It broadens the scope of first-principles transport calculations, enabling studies of a wide range of doped semiconductors and oxides with application to electronics, energy, and quantum technologies.

36 MATERIALS SCIENCE↗

Elemental ratio measurements of organic compounds using aerosol mass spectrometry: characterization, improved calibration, and implications

Elemental compositions of organic aerosol (OA) particles provide useful constraints on OA sources, chemical evolution, and effects. The Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA elemental composition. This study evaluates AMS measurements of atomic oxygen-to-carbon (O : C), hydrogen-to-carbon (H : C), and organic mass-to-organic carbon (OM : OC) ratios, and of carbon oxidation state ( OS C ) for a vastly expanded laboratory data set of multifunctional oxidized OA standards. For the expanded standard data set, the method introduced by Aiken et al. (2008), which uses experimentally measured ion intensities at all ions to determine elemental ratios (referred to here as "Aiken-Explicit"), reproduces known O : C and H : C ratio values within 20% (average absolute value of relative errors) and 12%, respectively. The more commonly used method, which uses empirically estimated H 2 O + and CO + ion intensities to avoid gas phase air interferences at these ions (referred to here as "Aiken-Ambient"), reproduces O : C and H : C of multifunctional oxidized species within 28 and 14% of known values. The values from the latter method are systematically biased low, however, with larger biases observed for alcohols and simple diacids. A detailed examination of the H 2 O + , CO + , and CO 2 + fragments in the high-resolution mass spectra of the standard compounds indicates that the Aiken-Ambient method underestimates the CO + and especially H 2 O + produced from many oxidized species. Combined AMS–vacuum ultraviolet (VUV) ionization measurements indicate that these ions are produced by dehydration and decarboxylation on the AMS vaporizer (usually operated at 600 °C). Thermal decomposition is observed to be efficient at vaporizer temperatures down to 200 °C. These results are used together to develop an "Improved-Ambient" elemental analysis method for AMS spectra measured in air. The Improved-Ambient method uses specific ion fragments as markers to correct for molecular functionality-dependent systematic biases and reproduces known O : C (H : C) ratios of individual oxidized standards within 28% (13%) of the known molecular values. The error in Improved-Ambient O : C (H : C) values is smaller for theoretical standard mixtures of the oxidized organic standards, which are more representative of the complex mix of species present in ambient OA. For ambient OA, the Improved-Ambient method produces O : C (H : C) values that are 27% (11%) larger than previously published Aiken-Ambient values; a corresponding increase of 9% is observed for OM : OC values. These results imply that ambient OA has a higher relative oxygen content than previously estimated. The OS C values calculated for ambient OA by the two methods agree well, however (average relative difference of 0.06 OS C units). This indicates that OS C is a more robust metric of oxidation than O : C, likely since OS C is not affected by hydration or dehydration, either in the atmosphere or during analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On-chip probabilistic inference for charged-particle tracking at the sensor edge

Modern scientific instruments operate under increasingly extreme constraints on bandwidth, latency, and power. Inference at the sensor edge determines experimental data collection efficiency by deciding which information to save for further analysis. Particle tracking detectors at the Large Hadron Collider exemplify this challenge: pixelated silicon sensors generate rich spatiotemporal ionization patterns, yet most of this information is discarded due to data-rate limitations. Concurrently, advancements in co-design tools provide rapid turn-around for incorporating machine learning into application-specific integrated circuits, motivating designs for particle detectors with new integrated technologies. We demonstrate that neural networks embedded in the front-end electronics can infer charged-particle kinematic parameters from a single silicon layer. We regress hit positions and incident angles with calibrated uncertainties, while satisfying stringent constraints on numerical precision, latency, and silicon area. Our results establish a path toward probabilistic inference directly at the edge, opening new opportunities for intelligent sensing in high-rate scientific instruments.

Das, Arghya Ranjan [Purdue U.] (ORCID:000000018451↗

New Developments in LC-MS and Other Hyphenated Techniques

Extensive challenges faced by analytical chemists in studying real world complex samples such as biological body fluids, tissue samples, environmental and geological samples have lead to the development of advanced analytical approaches. The vast array of contemporary technologies can be categorized into two major areas: sample separation and mass spectrometry analysis. Current state-of-the-art sample separation methods include gas chromatography, high performance liquid chromatography, ultra high pressure liquid chromatography, solid phase extraction, capillary electrophoresis, and gas phase separation techniques such as ion mobility spectrometry. The recent trend in sample separation is to combine (or hyphenate) multiple techniques that employ different separation mechanisms to maximize separation efficiency. The most widely used combinations include two-dimensional gas chromatography, strong cation exchange or weak cation exchange chromatography followed by reversed-phase liquid chromatography, two-dimensional reversed-phase liquid chromatography, liquid chromatography followed by ion mobility spectrometry and two-dimensional electrophoresis techniques. The introduction of atmospheric pressure ionization techniques such as electrospray ionization and matrix assisted laser desorption ionization and variations of the two have drastically increased the impact of mass spectrometry on bioanalytical applications. Mass spectrometry itself has tremendously improved over the years in terms of sensitivity, detection limits, dynamic range and sequencing capabilities. Currently, mass spectrometers can attain zeptomolole detection limits with five orders of magnitude dynamic range. In this chapter, we summarize recent developments in hyphenated techniques and their applications to complex sample analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High order harmonic generation in dual gas multi-jets

High order harmonic generation (HHG) in gas media suffers from a low conversion efficiency that has its origins in the interaction of the atom/molecule with the laser field. Phase matching is the main way to enhance the harmonic flux and several solutions have been designed to achieve it. Here we present numerical results modeling HHG in a system of multi-jets in which two gases alternate: the first gas jet (for example Ne) generates harmonics and the second one which ionizes easier, recover the phase matching condition. We obtain configurations which are experimentally feasible with respect to pressures and dimensions of the jets.

42 ENGINEERING↗

Space-charge effects in ionization beam profile monitors

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. At high beam intensities, the space-charge forces make the measured IPM profiles significantly different from those of the beams. We analyze dynamics of the secondaries in IPMs and develop an effective algorithm to reconstruct the beam sizes from the measured IPM profiles. Efficiency of the developed theory is illustrated in application to the Fermilab 8 GeV proton Booster IPMs.

43 PARTICLE ACCELERATORS↗