Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Colloid Rates of Radionuclides in Cooling Water of the 120-GeV Proton Accelerator Facilities at Fermilab - Paper 58

Cooling water systems for high-energy accelerators are typically equipped with a deionizer to keep water pure for accelerator materials and to remove radionuclides for radioactivity control. Although the deionizers are expected to collect the entire radionuclides, more radioactivity than expected remains in the cooling water in typical cooling water operations at J-PARC and the Tsukuba Campus of High Energy Accelerator Research Organization (KEK), Japan. For example, specific activity of {sup 7}Be in the cooling water for magnetic horns at the J-PARC Neutrino Experimental Facility was observed to be comparable to the limit of {sup 7}Be activity for drain (30 Bq/mL) after enough deionization duration. Removing this activity from the cooling water is an important problem that must be solved before the water can be released into the environment. In our previous study, it was found that some radionuclides had weak retention on ion-exchange resins in the cooling water deionizer system for the K2K target and magnetic horns at the 12-GeV proton accelerator in KEK, Japan. Incomplete adsorption in the deionizer was attributed to colloid formation. Therefore, understanding the colloid formation of radionuclides in cooling water is important for understanding the activity remaining in the cooling water. Colloid formation in water under high-intensity radiation fields has been investigated by previous irradiation experiments. Under 120-GeV proton irradiation of Cu foils in water, it was found that the colloid formation rates of Mg, Mn, Co, Ni, and Cu isotopes and those of {sup 7}Be, {sup 24}Na, {sup 42}K, and {sup 43}K were approximately 30% and 1.8-3.9%, respectively. Sc, Cr, and Fe isotopes were missing from the water. In the photon irradiation of water in a Cu tube using Bremsstrahlung from an electron linear accelerator and a {sup 60}Co γ-ray source at Kyoto University Research Reactor Institute, we observed Cu colloid formation in consequence of the corrosion of Cu. It is possible that radionuclides attach to the colloids formed by the corrosion of accelerator materials and pass through the deionizer. To enhance the understanding of the behavior of radionuclides in cooling water in a high-energy accelerator environment, we investigated the colloid formation of radionuclides in cooling waters at the 120-GeV proton accelerator facilities at Fermilab, USA. We have already reported the previous results of specific activities of γemitting radionuclides and {sup 3}H in water samples collected from eight cooling water systems. Following the previous study, this paper is concerned with the measurement of colloid formation rates of radionuclides in cooling waters. (authors)

43 PARTICLE ACCELERATORS↗

Analysis of a Linear System for Variable-Thrust Control in the Terminal Phase of Rendezvous

A linear system for applying thrust to a ferry vehicle in the 3 terminal phase of rendezvous with a satellite is analyzed. This system requires that the ferry thrust vector per unit mass be variable and equal to a suitable linear combination of the measured position and velocity vectors of the ferry relative to the satellite. The variations of the ferry position, speed, acceleration, and mass ratio are examined for several combinations of the initial conditions and two basic control parameters analogous to the undamped natural frequency and the fraction of critical damping. Upon making a desirable selection of one control parameter and requiring minimum fuel expenditure for given terminal-phase initial conditions, a simplified analysis in one dimension practically fixes the choice of the remaining control parameter. The system can be implemented by an automatic controller or by a pilot.

Hord, Richard A.↗

Propagation and stability characteristics of a 500-m-long laser-based fiducial line for high-precision alignment of long-distance linear accelerators

A laser-based alignment system with a He-Ne laser has been newly developed in order to precisely align accelerator units at the KEKB injector linac. The laser beam was first implemented as a 500-m-long fiducial straight line for alignment measurements. We experimentally investigated the propagation and stability characteristics of the laser beam passing through laser pipes in vacuum. The pointing stability at the last fiducial point was successfully obtained with the transverse displacements of ±40 μm level in one standard deviation by applying a feedback control. This pointing stability corresponds to an angle of ±0.08 μrad. This report contains a detailed description of the experimental investigation for the propagation and stability characteristics of the laser beam in the laser-based alignment system for long-distance linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Orbit And Dispersion Correction Scheme for the PEP II

To achieve optimum luminosity in a storage ring it is vital to control the residual vertical dispersion. In the original PEP storage ring, a scheme to control the residual dispersion function was implemented using the ring orbit as the controlling element. The 'best' orbit not necessarily giving the lowest vertical dispersion. A similar scheme has been implemented in both the on-line control code and in the simulation code LEGO. The method involves finding the response matrices (sensitivity of orbit/dispersion at each Beam-Position-Monitor (BPM) to each orbit corrector) and solving in a least squares sense for minimum orbit, dispersion function or both. The optimum solution is usually a subset of the full least squares solution. A scheme of simultaneously correcting the orbits and dispersion has been implemented in the simulation code and on-line control system for PEP-II. The scheme is based on the eigenvector decomposition method. An important ingredient of the scheme is to choose the optimum eigenvectors that minimize the orbit, dispersion and corrector strength. Simulations indicate this to be a very effective way to control the vertical residual dispersion.

43 PARTICLE ACCELERATORS↗

Design, Development and Testing Plan for Energy Efficiency Algorithms Related to Building-Integrated Cooling, Heating, and Power Systems

Building-integrated cooling, heating and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. It is estimated that the total CHP technical potential in the commercial building sector is approximately 76 GW, but only a small fraction of it is actually deployed. Advanced control and monitoring systems that realize the full potential of these CHP systems can transform this capacity into an asset for both the owner and the grid and also accelerate the adoption of these systems in the building sector. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. It has been demonstrated by several studies that as much as 30% of building energy use is wasted. Much of the waste results from the inability to anticipate load variations (design day vs. non-design day operations; diurnal variation of loads), identify improper operation, and efficiently operate, control and maintain building systems. Moreover, many buildings, even those with adequate control infrastructure, lack knowledgeable staff to operate and maintain energy systems. Operators of buildings with CHP systems will constantly need to make tradeoffs (economic dispatch) between onsite power generation and purchasing power, between onsite heat production from distributed generation versus heating/cooling from conventional systems, and different passive and active load management measures. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of a clean, efficient, reliable and affordable next-generation integrated energy systems. This report lists the components for which PM, real-time CxV and AFDD algorithms will be developed, how the algorithms will be tested, and metrics that will be used to validate the algorithms and easy of deployment. Deployment of these algorithms in the field will result in savings reduction in energy consumption of between 10% and 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical simulation of the dynamics of a liquid crystal in the case of plane strain using GPUs

Parallel computational algorithm is worked out for numerical implementation of two-dimensional dynamic model of a liquid crystal, which takes into account the mutual influence of three physical effects – transfer of acoustic energy due to translational motion, viscoelastic rotation of the particles under the action of tangential stresses, anisotropic thermal expansion and compression. The algorithm is based on the Godunov gap decay method, the Ivanov scheme with controlled dissipation of energy and the splitting method with respect to spatial variables. The CUDA technology for computer systems with graphic accelerators is used. Results of computations demonstrating the efficiency of proposed method and algorithm are represented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

43 PARTICLE ACCELERATORS↗

Experimental Results from Droop Compensation for the High Voltage Converter Modulators

The High Voltage Convertor Modulators are used to power the RF klystrons used throughout the linear accelerator at the Spallation Neutron Source. The output voltage of the modulator has significant voltage droop and ripple which, combined with low level RF system limitations, affect performance and stability of the accelerator cavities. In conjunction with the progress in the development of the new controller, different modulation techniques were implemented and studied on the test modulator. This paper discusses experimental results from implementation of different modulation schemes has on the modulator output voltage pulse. Thermal measurements were carried out to determine the effect of these modulations schemes on long term reliability of the modulator. Future plans are also discussed.

Accelerators↗

Field Insights: Strengthening Digital Assurance Through On-Site Network Monitoring

The accelerating deployment of digital energy infrastructure, ranging from inverter-based resources (IBRs), battery energy storage systems (BESS), to advanced grid control platforms, has brought unprecedented visibility, flexibility, and efficiency to the electric grid. However, this digital transformation also introduces new cybersecurity challenges, particularly in the form of supply chain risks and operational blind spots at the grid edge. Over the past year, the Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (CESER), through its Rapid Risk Assessment initiative, along with the Grid Deployment Office (GDO), through its Technical Assistance for Digital Assurance (TADA) initiative, have supported a series of on-site network engagements led by Idaho National Laboratory (INL). These engagements, conducted in partnership with asset owners across the country, have focused on identifying real-world vulnerabilities and misconfigurations in operational environments, many of which are not detectable through remote assessments or traditional compliance audits. The goal of this report is to distill key findings and lessons learned during network hunt engagements from INL’s fiscal year (FY) 2024 - 2025. It is intended to help asset owners—regardless of their participation in the program—better understand the evolving threat landscape and adopt practical measures to secure their digital energy infrastructure.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Low acceleration solid propellant rocket ignition study

A study was conducted to develop a solid-propellant rocket igniter system that would build up thrust at a controlled rate of less than 0.2 G/sec. The system consisted of a long burning, regressive burning, controlled flow igniter and an inhibited progressive burning surface in the main rocket motor. The igniter performed the dual role of igniting, under vacuum backpressure and low L* (motor free volume/nozzle throat area ratio) conditions, the nonrestricted portion of the propellant and providing the mass addition necessary to sustain combustion until the propellant burning area had increased sufficiently to provide a stable motor-chamber pressure. Two series of tests were conducted with existing small test motor hardware to: (1) demonstrate the feasibility of the concept, (2) determine the important parameters governing the system, and (3) obtain design guidelines for future scaled-up motor tests. A quasi-steady-state mass balance for the ignition system was written and programmed for use as a motor design tool.

Strand, L. D.↗

Dynamic wind-tunnel tests of an aeromechanical gust-alleviation system using several different combinations of control surfaces

Some experimental results are presented from wind tunnel studies of a dynamic model equipped with an aeromechanical gust alleviation system for reducing the normal acceleration response of light airplanes. The gust alleviation system consists of two auxiliary aerodynamic surfaces that deflect the wing flaps through mechanical linkages when a gust is encountered to maintain nearly constant airplane lift. The gust alleviation system was implemented on a 1/6-scale, rod mounted, free flying model that is geometrically and dynamically representative of small, four place, high wing, single engine, light airplanes. The effects of flaps with different spans, two size of auxiliary aerodynamic surfaces, plain and double hinged flaps, and a flap elevator interconnection were studied. The model test results are presented in terms of predicted root mean square response of the full scale airplane to atmospheric turbulence. The results show that the gust alleviation system reduces the root mean square normal acceleration response by 30 percent in comparison with the response in the flaps locked condition. Small reductions in pitch-rate response were also obtained. It is believed that substantially larger reductions in normal acceleration can be achieved by reducing the rather high levels of mechanical friction which were extant in the alleviation system of the present model.

Stewart, E. C.↗

Structures: Propulsion interactions and requirements

The dynamics of the interaction of space structures and their propellant systems are outlined. Optimization for a platform type of space structure is discussed. Static and transient loads, propellant accelerations, tolerances, attitude control, and distributed thrust are considered.

Pengelley, C. D.↗

Measurement, Control and Minimization of Thermal Shift in Superconducting Devices

Superconducting (SC) magnetic and SC radiofrequency (SRF) devices designed for use in particle accelerators present challenging alignment problems. These devices are assembled and aligned at room temperature but operate at 2-4 K with thermal offsets being large relative to the desired alignment tolerances. Unique solutions have been developed for controlling and minimizing the thermal shift including utilization of materials that expand under cooling to compensate for contraction and kinematic couplings. Measurement of the thermal shift within SC devices is performed using both optical telescope and laser instruments, typically through a parallel plate vacuum glass window. This paper presents techniques developed at Argonne National Laboratory for measuring, controlling and minimizing thermal shift in SC devices at both the Advanced Photon Source (APS) and the Argonne Tandem Linear Accelerator System (ATLAS).

Jansma, William G.↗

Detection of potential space station control/structure interaction with CO-ST-IN

The NASA Lewis Research Center is concerned with the potential of interaction between space station controllers and the solar PV array structures. The models required to handle this problem are very large, and automated methods were developed for the transfer of data between structural dynamic and control system analysis software. These methods emphasize the need to achieve accurate coupled analysis results while using as small a model as possible. Specific tools which help the analyst in this regard include modal order techniques, the use of mode acceleration to calculate internal loads and stresses and the transfer of Craig-Bampton components to reduce problems associated with modal sufficiency. These techniques were applied to a space station model with 366 modes below 1 Hz. Attitude control, and alpha and beta joint control were simulated. The inclusion of alpha and beta joint controllers is important when examining overall space station dynamics. An initial choice of control parameters does indicate a potential for control/structure interaction during reboost. As expected this is exacerbated by increasing the rate gain and decreasing the hysteresis of the reaction control system (RCS) in order to improve rigid body performance.

Carney, Kelly↗

STS-1 Forward RCS Oxidizer Tank Subsystem Failure Assessment

The launch of the Space Shuttle Columbia on STS-1 marked the beginning of a new era in American spaceflight. It was the only crewed first flight of a launch vehicle to date, and was also the first crewed system to use large solid rockets as primary propulsion. A potential disaster was narrowly averted at liftoff when an ignition overpressure pulse swept up the Shuttle stack. The frequency of this transient shock wave exceeded pre-launch predictions, and resulted in high, alternating normal accelerations along the length of the vehicle. Among the results of this unexpected loading was failure of an oxidizer tank support strut in the orbiter’s forward reaction control system module, which could have led to loss of the mission, crew, and vehicle. This particular incident is investigated in more detail using classical structural mechanics, and the results are discussed to provide additional insight.

Space Shuttle↗

STS-1 Forward RCS Oxidizer Tank Subsystem Preliminary Failure Assessment

The launch of the Space Shuttle Columbia on STS-1 marked the beginning of a new era in American spaceflight. It was the only crewed first flight of a launch vehicle to date, and was also the first crewed system to use large solid rockets as primary propulsion. A potential disaster was narrowly averted at liftoff when an ignition overpressure pulse swept up the Shuttle stack. The frequency of this transient shock wave exceeded pre-launch predictions, and resulted in high, alternating normal accelerations along the length of the vehicle. Among the results of this unexpected loading was failure of an oxidizer tank support strut in the orbiter’s forward reaction control system module, which could have led to loss of the mission, crew, and vehicle. This particular incident is investigated in more detail using classical structural mechanics, and the results are discussed to provide additional insight.

Space Shuttle↗