Search NASA⌕ Search

SEARCH · Search NASA

Results for “Active Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

MAGNETIC RECONNECTION ALONG QUASI-SEPARATRIX LAYERS AS A DRIVER OF UBIQUITOUS ACTIVE REGION OUTFLOWS

Hinode's EUV Imaging Spectrometer (EIS) has discovered ubiquitous outflows of a few to 50 km s{sup -1} from active regions (ARs). These outflows are most prominent at the AR boundary and appear over monopolar magnetic areas. They are linked to strong non-thermal line broadening and are stronger in hotter EUV lines. The outflows persist for at least several days. Using Hinode EIS and X-Ray Telescope observations of AR 10942 coupled with magnetic modeling, we demonstrate that the outflows originate from specific locations of the magnetic topology where field lines display strong gradients of magnetic connectivity, namely quasi-separatrix layers (QSLs), or in the limit of infinitely thin QSLs, separatrices. We found the strongest AR outflows to be in the vicinity of QSL sections located over areas of strong magnetic field. We argue that magnetic reconnection at QSLs separating closed field lines of the AR and either large-scale externally connected or 'open' field lines is a viable mechanism for driving AR outflows which are likely sources of the slow solar wind.

79 ASTRONOMY AND ASTROPHYSICS↗

FY20 Report for Instrumentation Development for the Transient Testing Program

This yearly report provides a summary of accomplishments carried out under funding from the Department of Energy (DOE) Nuclear Technology Research and Development (NTRD) program for in-pile instrumentation supporting the transient testing program in FY20. These activities were performed in support of cross-cutting transient testing experiment objective. In this year, specific instrument R&D has been a lesser priority to years past, with complementary instrumentation R&D being ramped up under the DOE Advanced Sensors and Instrumentation Program. The primary focus of the work in FY20 pertain to defining a process and system, developed over the past several years, for developing, qualifying, and deploying instrumentation in in-pile experiments. The purpose of this report is to provide a summary of these outcomes and be a reference for researchers that are interested in developing in-pile instrumentation, with a particular emphasis on the Transient Reactor Test (TREAT) facility for deployment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the Probing In-Situ with Neutron and Gamma Rays (PING) Instrument for Planetary Science Applications

The Probing In situ with Neutrons and Gamma rays (PING) instrument is a promising planetary science application of the active neutron-gamma ray technology that has been used successfully in oil field well logging and mineral exploration on Earth for decades. Similar techniques can be very powerful for non-invasive in situ measurements of the subsurface elemental composition on other planets. The objective of our active neutron-gamma ray technology program at NASA Goddard Space Flight Center (NASA/GSFC) is to bring instruments using this technology to the point where they can be flown on a variety of surface lander or rover missions to the Moon, Mars, Venus, asteroids, comets and the satellites of the outer planets. PING combines a 14 MeV deuterium-tritium pulsed neutron generator with a gamma ray spectrometer and two neutron detectors to produce a landed instrument that can determine the elemental composition of a planet down to 30 - 50 cm below the planet's surface. The penetrating nature of.5 - 10 MeV gamma rays and 14 MeV neutrons allows such sub-surface composition measurements to be made without the need to drill into or otherwise disturb the planetary surface, thus greatly simplifying the lander design. We are currently testing a PING prototype at a unique outdoor neutron instrumentation test facility at NASA/GSFC that provides two large (1.8 m x 1.8 m x.9 m) granite and basalt test formations placed outdoors in an empty field. Since an independent trace elemental analysis has been performed on both the Columbia River basalt and Concord Gray granite materials, these samples present two known standards with which to compare PING's experimentally measured elemental composition results. We will present experimental results from PING measurements of both the granite and basalt test formations and show how and why the optimum PING instrument operating parameters differ for studying the two materials.

Parsons, A.↗

Perseverance Rover’s Robotic Arm and Turret Mounted Instruments’ Surface Commissioning

The Robotic Arm (RA) on the Perseverance rover is an integral component of the Sampling and Caching System necessary for completing the science goals of the Mars 2020 mission. While the Perseverance rover was based on the Curiosity rover which landed in 2012, the Robotic Arm was redesigned to carry a much larger turret with a new suite of payloads. Shortly after Perseverance landed in Jezero Crater, a series of checkouts was completed with the RA during the first 100 sols of the mission in order to ensure proper functionality of the RA and the instruments mounted on the turret. This period of time in the mission was called Surface Operations Transition (SOX). The objective of SOX was to systematically execute checkout activities for all the basic functionality so that the RA and instruments, as well as other rover components, could be released for scientific exploration.RA activities during SOX can be divided into a few different categories: Mechanism Checkouts, Rover Visual Inspections, Performance Characterization, and Instrument Functional Checkouts. Many of these checkouts built off of each other such that each subsequent activity would verify incrementally complex functionality. Many of the defined activities were executed several times throughout the development of the rover and served as a check that the RA’s performance is consistent with testing on Earth. Other activities were developed uniquely for SOX to respond to challenges discovered during development. They were designed to be verifiable without the help of ground support equipment or previous executions on the flight hardware to compare against.This paper discusses the formulation and conception of the various RA SOX checkout activities, verification and testing required to certify them for flight, execution of the activities on Mars, issues encountered, and finally results and findings as the mission transitioned to nominal science operations. We will be presenting the results and analysis using downlinked imaging and data from the flight vehicle to show how we verified the performance of the Robotic Arm and the turret mounted instruments in order to transition to science operations with a clean bill of health.

Edgett, Kenneth↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

Ames collaborative study of cosmic ray neutrons

The results of a collaborative study to define both the neutron flux and the spectrum more precisely and to develop a dosimetry package that can be flown quickly to altitude for solar flare events are described. Instrumentation and analysis techniques were used which were developed to measure accelerator-produced radiation. The instruments were flown in the Ames Research Center high altitude aircraft. Neutron instrumentation consisted of Bonner spheres with both active and passive detector elements, threshold detectors of both prompt-counter and activation-element types, a liquid scintillation spectrometer based on pulse-shape discrimination, and a moderated BF3 counter neutron monitor. In addition, charged particles were measured with a Reuter-Stokes ionization chamber system and dose equivalent with another instrument. Preliminary results from the first series of flights at 12.5 km (41,000 ft) are presented, including estimates of total neutron flux intensity and spectral shape and of the variation of intensity with altitude and geomagnetic latitude.

Hewitt, J. E.↗

Modeling fault diagnosis as the activation and use of a frame system

Twenty pilots with instrument flight ratings were asked to perform a fault-diagnosis task for which they had relevant domain knowledge. The pilots were asked to think out loud as they requested and interpreted information. Performances were then modeled as the activation and use of a frame system. Cognitive biases, memory distortions and losses, and failures to correctly diagnose the problem were studied in the context of this frame system model.

Smith, Philip J.↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

NOAA-20 VIIRS on-Orbit Calibration Improvements

The NOAA-20 (N-20) VIIRS has successfully operated for more than two years since its launch in November 2017. Shortly after completing its initial instrument check-outs and post-launch testing (PLT) activities, the N-20 VIIRS sensor data records (SDR) achieved the beta, provisional, and validated maturity status in January, February, and April 2018, respectively. In this paper, we briefly describe the instrument on-orbit operation and calibration activities, provide an overall assessment of its on-orbit performance, and discuss the methodologies developed to maintain and improve sensor calibration and data quality. As illustrated in this paper, the N-20 VIIRS continues to perform with excellent stability, allowing high-quality environmental data records (EDR) to be generated from its well-calibrated SDR.

NOAA-20↗

Droplet activation, separation, and compositional analysis: Laboratory studies and atmospheric measurements

Droplets produced in a cloud condensation nucleus chamber as a function of supersaturation have been separated from unactivated aerosol particles using counterflow virtual impaction. Residual material after droplets were evaporated was chemically analyzed with an Aerodyne Aerosol Mass Spectrometer and the Particle Analysis by Laser Mass Spectrometry instrument. Experiments were initially conducted to verify activation conditions for monodisperse ammonium sulfate particles and to determine the resulting droplet size distribution as a function of supersaturation. Based on the observed droplet size, the counterflow virtual impactor cut-size was set to differentiate droplets from unactivated interstitial particles. Validation experiments were then performed to verify that only droplets with sufficient size passed through the counterflow virtual impactor for subsequent analysis. A two-component external mixture of monodisperse particles was also exposed to a supersaturation which would activate one of the types (ammonium sulfate) but not the other (polystyrene latex spheres). The mass spectrum observed after separation indicated only the former, validating separation of droplets from unactivated particles. Results from atmospheric measurements using this technique indicate that aerosol particles often activate predominantly as a function of particle size. Chemical composition is not irrelevant, however, and we observed enhancement of sulfate in droplet residuals using single particle analysis.

54 ENVIRONMENTAL SCIENCES↗

Solar flare hard and soft x ray relationship determined from SMM HXRBS and BCS data

The exact nature of the solar flare process is still somewhat a mystery. A key element to understanding flares if the relationship between the hard x rays emitted by the most energetic portions of the flare and the soft x rays from other areas and times. This relationship was studied by comparing hard x ray light curved from the Hard X-Ray Burst Spectrometer (HXRBS) with the soft x ray light curve and its derivation from the Bent Crystal Spectrometer (BCS) which is part of the X-Ray Polychrometer (XRP), these instruments being on the Solar Maximum Mission spacecraft (SMM). Data sample was taken from flares observed with the above instruments during 1980, the peak of the previous maximum of solar activity. Flares were chosen based on complete coverage of the event by several instruments. The HXRBS data covers the x ray spectrum from about 25 keV to about 440 keV in 15 spectral channels, while the BCS data used covers a region of the Spectrum around 3 angstroms including emission from the Ca XIX ion. Both sets of data were summed over their spectral ranges and plotted against time at a maximum time resolution of around 3 seconds. The most popular theory of flares holds that a beam of electrons produces the hard x rays by bremsstrahlung while the soft x rays are the thermal response to this energy deposition. The question is whether the rate of change of soft x ray emission might reflect the variability of the electron beam and hence the variability of the hard x rays. To address this, we took the time derivative of the soft x ray light curve and compared it to the hard flares, 12 of them showed very closed agreement between the soft x ray derivative and the hard x ray light curve. The other five did not show this behavior but were similar to each other in general soft x ray behavior. Efforts to determine basic differences between the two kinds of flares continue. In addition the behavior of soft x ray temperature of flares was examined.

Toot, G. David↗

Sequential Learning with Active Partial Labeling for Building Metadata

Modern buildings are instrumented with thousands of sensing and control points. The ability to automatically extract the physical context of each point, e.g., the type, location, and relationship with other points, is the key to enabling building analytics at scale. However, this process is costly as it usually requires domain expertise with a deep understanding of the building system and its point naming scheme. In this study, we aim to reduce the human effort required for mapping sensors to their context, i.e., metadata mapping. We formulate the problem as a sequential labeling process and use the conditional random field to exploit the regular and dependent structures observed in the metadata. We develop a suite of active learning strategies to adaptively select the most informative subsequences in point names for human labeling, which significantly reduces the inputs from domain experts.We evaluated our approach on three different buildings and observed encouraging performance in metadata mapping from the proposed solution.

99 GENERAL AND MISCELLANEOUS↗

Topological Characterization of Coordination-Driven Self-assembly Complexes: Applications of Ion Mobility-Mass Spectrometry

Coordination-driven self-assembly (CDSA) is increasingly used to synthesize coordination complexes containing metal-centered electron acceptors and typically nitrogen-containing electron donors. Characterization of the structures obtained from CDSA via crystallographic or spectroscopic means is limited due to difficulties in forming single crystals for X-ray studies and overlapping precursor and product signals in NMR. Here, we employ ion mobility-mass spectrometry (IM-MS), which provides a direct measure of size and shape of the CDSA complexes, to study the intact reaction products of a rhomboid-shaped complex. This approach negates the need for product isolation and crystallization and allows for tracking of the product distribution as a function of time. A potential challenge of IM-MS is that the size/shape of the observed CDSA complexes can vary with internal energy; however, we show that proper tuning of the instrument reduces the effects of collisional activation thereby allowing for retention of ion conformations that reflect solution-phase ion structures. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The CMS Outer Tracker for the High-Luminosity LHC

The era of High-Luminosity Large Hadron Collider will pose unprecedented challenges for detector design and operation. The planned luminosity of the upgraded machine is 5– 7.5×10$^{34}$ cm$^{-2}$s$^{-1}$ , reaching an integrated luminosity of 3000–4000 fb$^{-1}$ by the end of 2039. The CMS Tracker detector will have to be replaced in order to fully exploit the delivered luminosity and cope with the demanding operating conditions. The new detector will provide robust tracking as well as input for the first level trigger. This report is focusing on the replacement of the CMS Outer Tracker system, describing new layout and technological choices together with some highlights of research and development activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MAPPING THE DISTRIBUTION OF ELECTRON TEMPERATURE AND Fe CHARGE STATES IN THE CORONA WITH TOTAL SOLAR ECLIPSE OBSERVATIONS

The inference of electron temperature from the ratio of the intensities of emission lines in the solar corona is valid only when the plasma is collisional. Once collisionless, thermodynamic ionization equilibrium no longer holds, and the inference of an electron temperature and its gradient from such measurements is no longer valid. At the heliocentric distance where the transition from a collision-dominated to a collisionless plasma occurs, the charge states of different elements are established, or frozen-in. These are the charge states which are subsequently measured in interplanetary space. We show in this study how the 2006 March 29 and 2008 August 1 eclipse observations of a number of Fe emission lines yield an empirical value for a distance, which we call R{sub t} , where the emission changes from being collisionally to radiatively dominated. R{sub t} ranges from 1.1 to 2.0 R{sub sun}, depending on the charge state and the underlying coronal density structures. Beyond that distance, the intensity of the emission reflects the distribution of the corresponding Fe ion charge states. These observations thus yield the two-dimensional distribution of electron temperature and charge state measurements in the corona for the first time. The presence of the Fe X 637.4 nm and Fe XI 789.2 nm emission in open magnetic field regions below R{sub t} , such as in coronal holes and the boundaries of streamers, and the absence of Fe XIII 1074.7 nm and Fe XIV 530.3 nm emission there indicate that the sources of the solar wind lie in regions where the electron temperature is less than 1.2 x 10{sup 6} K. Beyond R{sub t} , the extent of the Fe X [Fe{sup 9+}] and Fe XI emission [Fe{sup 10+}], in comparison with Fe XIII [Fe{sup 12+}] and Fe XIV [Fe{sup 13+}], matches the dominance of the Fe{sup 10+} charge states measured by the Solar Wind Ion Composition Spectrometer, SWICS, on Ulysses, at -43{sup 0} latitude at 4 AU, in March-April 2006, and Fe{sup 9+} and Fe{sup 10+} charge states measured by SWICS on the Advanced Composition Explorer, ACE, in the ecliptic plane at 1 AU, at the time of both eclipses. The remarkable correspondence between these two measurements establishes the first direct link between the distribution of charge states in the corona and in interplanetary space.

79 ASTRONOMY AND ASTROPHYSICS↗

DIRECT OBSERVATIONAL EVIDENCE OF FILAMENT MATERIAL WITHIN INTERPLANETARY CORONAL MASS EJECTIONS

Coronal mass ejections (CMEs) are explosive events that escape the Sun's corona carrying solar material and energy into the heliosphere. The classic picture of a CME observed in the corona presents a 'three-part structure', including a bright front at the leading edge indicating dense plasma, a low-density cavity, the possible signature of an embedded magnetic flux rope, and the so-called core, a high-density region observed to be associated with an erupting filament. Although there are experimental analogs to the first two parts of the CME when observed in situ, there are only a handful of in situ observations of cold, filament-type plasma. This has been a source of major uncertainty and qualitative disagreement between remote and in situ observations of these ejecta. We present the first comprehensive and long-term survey of such low charge states observed by the Advanced Composition Explorer Solar Wind Ion Composition Spectrometer, using a novel data analysis process developed to identify ions with low ionic charge states. Using a very stringent set of observational signatures, we find that more than 4% of detected interplanetary CMEs have significant contributions of ions with low charge states. These time periods of low-charge ions often occur concurrent with some of the hottest ions, previously interpreted to be affected by flare heating during the CME initiation.

79 ASTRONOMY AND ASTROPHYSICS↗

Online Monitoring of Induction Motors

The online monitoring of active components project, under the Advanced Instrumentation, Information, and Control Technologies Pathway of the Light Water Reactor Sustainability Program, researched diagnostic and prognostic models for alternating current induction motors (IM). Idaho National Laboratory (INL) worked with the Electric Power Research Institute (EPRI) to augment and revise the fault signatures previously implemented in the Asset Fault Signature Database of EPRI’s Fleet Wide Prognostic and Health Management (FW PHM) Suite software. Induction Motor diagnostic models were researched using the experimental data collected by Idaho State University. Prognostic models were explored in the set of literature and through a limited experiment with 40HP to seek the Remaining Useful Life Database of the FW PHM Suite.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗