Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Detector Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Post Launch Calibration and Testing of the Advanced Baseline Imager on the GOES-R Satellite

The Geostationary Operational Environmental Satellite R (GOES-R) series is the planned next generation of operational weather satellites for the United States National Oceanic and Atmospheric Administration. The first launch of the GOES-R series is planned for October 2016. The GOES-R series satellites and instruments are being developed by the National Aeronautics and Space Administration (NASA). One of the key instruments on the GOES-R series is the Advance Baseline Imager (ABI). The ABI is a multi-channel, visible through infrared, passive imaging radiometer. The ABI will provide moderate spatial and spectral resolution at high temporal and radiometric resolution to accurately monitor rapidly changing weather. Initial on-orbit calibration and performance characterization is crucial to establishing baseline used to maintain performance throughout mission life. A series of tests has been planned to establish the post launch performance and establish the parameters needed to process the data in the Ground Processing Algorithm. The large number of detectors for each channel required to provide the needed temporal coverage presents unique challenges for accurately calibrating ABI and minimizing striping. This paper discusses the planned tests to be performed on ABI over the six-month Post Launch Test period and the expected performance as it relates to ground tests.

Instrument↗

Advances in Small Pixel TES-Based X-Ray Microcalorimeter Arrays for Solar Physics and Astrophysics

We are developing small-pixel transition-edge-sensor (TES) for solar physics and astrophysics applications. These large format close-packed arrays are fabricated on solid silicon substrates and are designed to accommodate count-rates of up to a few hundred counts/pixel/second at a FWHM energy resolution approximately 2 eV at 6 keV. We have fabricated versions that utilize narrow-line planar and stripline wiring. We present measurements of the performance and uniformity of kilo-pixel arrays, incorporating TESs with single 65-micron absorbers on a 7s-micron pitch, as well as versions with more than one absorber attached to the TES, 4-absorber and 9-absorber "Hydras". We have also fabricated a version of this detector optimized for lower energies and lower count-rate applications. These devices have a lower superconducting transition temperature and are operated just above the 40mK heat sink temperature. This results in a lower heat capacity and low thermal conductance to the heat sink. With individual single pixels of this type we have achieved a FWHM energy resolution of 0.9 eV with 1.5 keV Al K x-rays, to our knowledge the first x-ray microcalorimeter with sub-eV energy resolution. The 4-absorber and 9-absorber versions of this type achieved FWHM energy resolutions of 1.4 eV and 2.1 eV at 1.5 keV respectively. We will discuss the application of these devices for new astrophysics mission concepts.

Bandler, S. R.↗

Diamond and SiC Detectors for Rare Event Searches

In recent years, there has been increasing interest in developing detectors which are sensitive to sub-GeV dark matter and low-energy events from coherent neutrino scattering. Due to carbon’s light atomic weight and its tendency to form crystals with high-energy, long-lived phonon modes, carbon-based crystals (including diamond and silicon carbide (SiC)) present themselves as natural target materials for scattering-based searches in this regime. Here, we present our preliminary results in adapting our TES-based detectors to these substrates, specifically 4-H SiC and polycrystalline diamond. We focus on our fabrication efforts, specifically tuning the transition temperature (T C ) of tungsten films sputtered on these materials, as well as our advancement toward fabricating and testing devices on these substrates.

47 OTHER INSTRUMENTATION↗

A 5- μ m pitch charge-coupled device optimized for resonant inelastic soft X-ray scattering

Here, we have developed a charge-coupled device (CCD) with 5 μm × 45 μm pixels on high-resistivity silicon. The fully depleted 200 μm-thick silicon detector is back-illuminated through a 10 nm-thick in situ doped polysilicon window and is thus highly efficient for soft through > 8 keV hard X-rays. The device described here is a 1.5 megapixel CCD with 2496 × 620 pixels. The pixel and camera geometry was optimized for Resonant Inelastic X-ray Scattering (RIXS) and is particularly advantageous for spectrometers with limited arm lengths. In this article, we describe the device architecture, construction and operation, and its performance during tests at the Advance Light Source (ALS) 8.0.1 RIXS beamline. The improved spectroscopic performance, when compared with a current standard commercial camera, is demonstrated with a ~280 eV (C K ) X-ray beam on a graphite sample. Readout noise is typically 3-6 electrons and the point spread function for soft C K X-rays in the 5 μm direction is 4.0 μm ± 0.2 μm. Finally, the measured quantum efficiency of the CCD is greater than 75% in the range from 200 eV to 1 keV.

36 MATERIALS SCIENCE↗

Multimode scanning X-ray diffraction microscopy for diamond anvil cell experiments

We have designed and implemented a new experimental system for fast mapping of crystal structures and other structural features of materials under high pressure at the High Pressure Collaborative Access Team, Sector 16 of the Advanced Photon Source. The system utilizes scanning X-ray diffraction microscopy (SXDM) and is optimized for use with diamond anvil cell devices. In SXDM, the X-ray diffraction (XRD) is collected in a forward scattering geometry from points on a two-dimensional grid by fly-scanning the sample with respect to a micro-focused X-ray beam. The recording of XRD is made during the continuous motion of the sample using a fast (millisecond) X-ray area detector in synchrony with the sample positioners, resulting in a highly efficient data collection for SXDM. A new computer program, X-ray Diffractive Imaging (XDI), has been developed with the SXDM system. The XDI program provides a graphical interface for constructing and displaying the SXDM images in several modes: (1) phase mapping based on structural information, (2) pressure visualization based on the equation of state, (3) microstructural features mapping based on peak shape parameters, and (4) grain size and preferred-orientation based on peak shape parameters. The XDI is a standalone program and can be generally used for displaying SXDM images. Two examples of iron and zirconium samples under high pressure are presented to demonstrate the applications of SXDM. Published under license by AIP Publishing.

47 OTHER INSTRUMENTATION↗

Laser Energy Monitor for Triple-Pulse 2-μm IPDA Lidar Application

Integrated path differential absorption (IPDA) lidar is an active remote sensing technique for monitoring different atmospheric species. The technique relies on wavelength differentiation between strong and weak absorbing features normalized to the transmitted energy. An advanced 2-μm triple-pulse IPDA lidar was developed at NASA Langley Research Center for active sensing of carbon dioxide and water vapor simultaneously. The IPDA transmitter produces three successive laser pulses separated by a short interval (200 μs) with a repetition rate of 50Hz. Measurement of laser pulse energy accurately is a prerequisite for the retrieval of gas mixing ratios from IPDA. The design and calibration of a 2-μm triple-pulse laser energy monitor are presented. Due to the short interval between the three transmitted pulses, conventional thermal energy monitors underestimate the total transmitted energy. The design is based on a high speed, extended range InGaAs pin quantum detector suitable for separating the three pulse events. Pulse integration is applied for converting the detected pulse power into energy. The results obtained from the laser energy monitor were compared to an ultra-fast energy-meter reference for energy scaling and verification. High correlations between the pin energy monitor and the total transmitted energy were obtained. The objective of this development is to reduce measurement biases and errors using the triple-pulse IPDA technique.

Refaat, Tamer F.↗

AN ADVANCED ULTRASONIC WAVEGUIDE CONCEPT FOR SPATIALLY DISTRIBUTED MONITORING OF IN-CORE TEMPERATURES

Critical process temperatures in a reactor core are conventionally measured using either resistance temperature detectors or thermocouples, both of which exhibit performance degradation at the temperature ranges of advanced reactors. Ultrasonic thermometry (UT) has long been offered as an alternative, potentially robust measurement option. With emerging interest in advanced reactors and a trend toward extracting more information from the core and the connected heat transport systems, UT is again considered a potential measurement method. Conventionally, acoustic waveguides employ simple notches at a measurement point to reflect incident waves. However, this approach results in rapid attenuation of acoustic energy as the wave crosses notches, as some fraction of its energy is reflected while the rest is transmitted. This research addresses this fundamental issue. This paper reports on the development of an ultrasonic waveguide concept that exploits the constructive interference of wave dynamics. The waveguide uses acoustic filters at the measurement zones that exhibit very high transmittance or reflectance as a function of interrogation frequency. Preliminary results will be discussed.

Cetiner, Nesrin↗

Fuel Cycle Research & Development Technical Monthly – May 2012

Management and Integration LANL - Initial coordination meetings with NE and NA-20 were held the first week of May. Additional meetings, to include NA-82 and the new Proliferation and Terrorism Risk Assessment task are scheduled for June. Work package planning as part of the NTD transition is ongoing. Microcalorimetry LANL - Some parts to attempt repair of a malfunctioning water chiller that has been holding up work on the current detector array have arrived. We will attempt to begin running the compressor/cryostat next week to resume work on commissioning the detector array. We have also been working on a backup plan to temporarily move our system to a different lab space. Completed data analysis and prepared a paper summarizing Pu measurements for peer-review journal. Two members of our team presented work at the SORMA West 2012 conference. Completed data analysis and prepared a milestone report summarizing the development of Monte Carlo tools to study systematic errors. Electrochemical Sensor INL - The second sensor test was stopped short due to the work stand-down. Some activities related to this work have resumed, but not all. The sensor used during the second test was removed from the furnace and it showed cracks and later crumbled when being rinsed for sample preparation. The sensor material will be submitted to SEM analysis once work is resumed in the facilities where analysis is performed. A third sensor test has started. Tests with different arrangements will continue and will be oriented based on post-test analysis of the first three sensor tests. Materials with different annealing temperatures will also be prepared for analysis. Lead slowing down spectrometer LANL - Continued work on perturbation method for LSDS analysis. We are running simulations to delineate issues and are checking additional data libraries to see whether there are differences in simulation results. Electrochemical sensor INL - The second sensor test was stopped short due to the work stand-down. Some activities related to this work have resumed, but not all. The sensor used during the second test was removed from the furnace and it showed cracks and later crumbled when being rinsed for sample preparation. The sensor material will be submitted to SEM analysis once work is resumed in the facilities where analysis is performed. A third sensor test has started. Tests with different arrangements will continue and will be oriented based on post-test analysis of the first three sensor tests. Materials with different annealing temperatures will also be prepared for analysis. Fast Neutron Multiplicity analysis INL - The University of Michigan team continues its work on the post-experiment analysis of the validation data from JRC ISPRA, as well as scoping studies using the simulation tool MCNPX-PoliMi. At INL, our new staff member working on this project is now working to model performance capabilities for the fast-neutrons scintillator design concepts. At INL our primary analysis approach is focused on the Feynman mean-to-variance approach. At the University of Michigan, the primary analysis approach is multiplicity coincidence analysis. Fast Neutron Imaging to Quantify Nuclear Materials ORNL - Completed additional measurements of the two 'trainer' configurations as well as calibration measurements with sources on an x-y stage. The imager was shipped to Pantex for an NA-22 obligation at the end of May. Lead Slowing Down Spectrometer LANL - Continued to look into He4 detector. A Swiss company was located that makes He4 detectors and associated electronics. Had a teleconference with them to assess the possible help we can get from them. We are also looking in to constructing one locally. Ongoing perturbation calculations are providing information on the fundamental systematic error limits of LSDS. In order to achieve separating the contribution of Pu and 235U to the signal, there will need to be tight controls on systematic errors. Multi-isotope Process Monitor PNNL - Attended a training call in advanced multivariate classification and analysis methods. These methods were applied to the multivariate analysis of fuel characteristics based on simulated gamma. Work continued on a computational framework to quantify the impact of gamma-ray counting statistical precision on principal component regression (PCR) analysis of a multi-component (i.e. multi-isotope) gammaray spectrum. Tests of the simulation framework are anticipated to begin in early June. Development of a proposal to instrument H-Canyon is being prepared in conjunction with SRNL and the NNSA's NGSI program is ongoing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RadLab: A Comprehensive Database and Graphical and Programming Interfaces for Space Radiation Data

RadLab, a component of the NASA Open Science Data Repository (OSDR), is a database of radiation measurements from multiple instruments and spacecraft that provides visual and programmatic interfaces for interrogation and retrieval of these data. The attributes of data available through RadLab include spacecraft, types of radiation sensing instruments, locations within the spacecraft (e.g. ISS modules), associated celestial bodies, trajectories, and spacecraft coordinates; the primary type of data is the absorbed dose rate, as well as flux and dose equivalent rate where available. The application programming interface (API) implements a request syntax for retrieval of timestamped data filtered by various combinations of such attributes; the graphical user interface (GUI) extends this functionality with visualizations (time series plots, comparison plots, geospatial visualizations) which provide easy means to assess data availability, iteratively refine search parameters, interactively inspect the data, and export target data subsets. Datasets are continuously being added to the RadLab database as part of the rolling release process. Investigators from multiple countries, including the US, Canada, Germany, Bulgaria, Hungary, Italy, Japan, Russia and the Czech Republic, have committed to provide data from their instruments in and beyond low Earth orbit. The current release contains datasets provided by US and international collaborators and includes readings from multiple modules of the ISS, the BioSentinel CubeSat, Chang’e 4, the Lunar Reconnaissance Orbiter, the ExoMars Orbiter, and the Curiosity rover. Datasets are associated with respective RadLab knowledgebase articles which include instrument descriptions and provide bibliographical references. RadLab aims to provide a comprehensive, dynamic compendium of space radiation data, enabling the scientific community to perform analyses of data from multiple detectors and to determine the radiation environment of research missions and experiments. Some of its applications include inference of absorbed radiation dose for NASA GeneLab payloads, and training predictive models as part of the 2024 FDL-X challenge. The platform is actively expanding and seeking additional data, with plans to also cover past (e.g. Shuttle, Mir) and future (e.g. Artemis) missions. The RadLab Working Group has been created to aid in this process as well as to foster collaborations among data contributors and users, to develop standards for data harmonization, and to guide the development of the platform, with the goal to establish the use of RadLab in space radiation research and to advance our understanding of the radiation environment in outer space.

Kirill Grigorev↗

RadLab: A Comprehensive Database and Graphical and Programming Interfaces for Space Radiation Data

RadLab, a component of the NASA Open Science Data Repository (OSDR), is a database of radiation measurements from multiple instruments and spacecraft that provides visual and programmatic interfaces for interrogation and retrieval of these data. The attributes of data available through RadLab include spacecraft, types of radiation sensing instruments, locations within the spacecraft (e.g. ISS modules), associated celestial bodies, trajectories, and spacecraft coordinates; the primary type of data is the absorbed dose rate, as well as flux and dose equivalent rate where available. The application programming interface (API) implements a request syntax for retrieval of timestamped data filtered by various combinations of such attributes; the graphical user interface (GUI) extends this functionality with visualizations (time series plots, comparison plots, geospatial visualizations) which provide easy means to assess data availability, iteratively refine search parameters, interactively inspect the data, and export target data subsets. Datasets are continuously being added to the RadLab database as part of the rolling release process. Investigators from multiple countries, including the US, Canada, Germany, Bulgaria, Hungary, Italy, Japan, Russia and the Czech Republic, have committed to provide data from their instruments in and beyond low Earth orbit. The current release contains datasets provided by US and international collaborators and includes readings from multiple modules of the ISS, the BioSentinel CubeSat, Chang’e 4, the Lunar Reconnaissance Orbiter, the ExoMars Orbiter, and the Curiosity rover. Datasets are associated with respective RadLab knowledgebase articles which include instrument descriptions and provide bibliographical references. RadLab aims to provide a comprehensive, dynamic compendium of space radiation data, enabling the scientific community to perform analyses of data from multiple detectors and to determine the radiation environment of research missions and experiments. Some of its applications include inference of absorbed radiation dose for NASA GeneLab payloads, and training predictive models as part of the 2024 FDL-X challenge. The platform is actively expanding and seeking additional data, with plans to also cover past (e.g. Shuttle, Mir) and future (e.g. Artemis) missions. The RadLab Working Group has been created to aid in this process as well as to foster collaborations among data contributors and users, to develop standards for data harmonization, and to guide the development of the platform, with the goal to establish the use of RadLab in space radiation research and to advance our understanding of the radiation environment in outer space.

Kirill Grigorev↗

Probing individual single atom electrocatalyst sites by advanced analytical scanning transmission electron microscopy

Single atom electrocatalysts (SAEs) are promising next-generation materials for promoting a variety of important reactions, such as the oxygen reduction, nitrogen reduction, and CO 2 reduction reactions. While bulk characterization techniques such as X-ray absorption spectroscopy and Mössbauer spectroscopy have significantly enhanced our understanding of these catalysts, direct probing of individual single metal atom sites at the atomic scale is necessary to understand local variations in the properties of these sites and accelerate design and synthesis of improved SAEs. Aberration-corrected scanning transmission electron microscopy (STEM) has become a powerful tool for providing this type of atomic-scale information about SAE metal sites. These sites are typically unstable under the electron beam, however, which, in combination with conventional acquisition methods and detectors, has limited the type and quantity of information obtainable by spectroscopic STEM techniques. Here, we map multiple individual SAE metal sites in a nitrogen-doped carbon containing atomically dispersed Fe and Re (FeReNC) at the atomic scale by direct electron detection electron energy-loss spectroscopy (EELS). Direct electron detection provides an improved signal-to-noise ratio over conventional scintillator-based detectors and enables detection and real space localization of weak signals. In addition, we demonstrate an automated method for identification of metal atom positions, placement of the probe on these sites, and simultaneous EELS and energy dispersive X-ray spectroscopic (EDS) signal acquisition. This simultaneous acquisition of EELS and EDS provides access to the composition and bonding of a wide range of SAE metal sites. In this study, focusing the probe directly on the metal sites also increases the relevant data acquisition rate by more than an order of magnitude over two-dimensional mapping, enabling improved statistical measurements of site properties. The versatility, sensitivity, and speed that these techniques provide enhances our ability to probe the local elemental and chemical environment of a large number of individual SAE metal site structures at the atomic scale, enabling an improved understanding of the variations in the local properties of these electrocatalysts to be gained. As a result, significantly increased information about individual metal sites will be available to future electrochemical studies through these techniques, accelerating the development of advanced SAEs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detector Interface for Streaming, Control, and Open-source integration (DISCO) v1.0.0

This suite consists of a multi-package ecosystem featuring detector emulators, EPICS areaDetector drivers, and remote server frameworks designed for the Advanced Light Source (ALS). Engineered for high-bandwidth devices—including VFCCD, Timepix3, Timepix4, and related pixel detectors—the software simulates hardware, wraps vendor SDKs into remote-callable servers, and integrates with open-source control systems. Key Capabilities: Distributed SDK Architecture: Server packages wrap hardware-specific SDKs, allowing areaDetector drivers to execute remote framework calls. This isolates proprietary libraries from the EPICS IOC, enhancing stability and enabling distributed computing across beamline networks. Device Support: Custom drivers for VFCCD, the Timepix family, and similar sensors optimize the data path from hardware control to high-speed transport. Full-Stack Emulation: Sophisticated emulator packages allow end-to-end pipeline testing and software development without requiring physical hardware or beam time. Integrated Workflows: Supports high-bandwidth streaming for real-time analysis and robust, metadata-rich file-based workflows (e.g., HDF5/NeXus). By standardizing interfaces across heterogeneous hardware, this suite reduces technical debt. It provides the ALS with a scalable, open-source solution to manage massive data rates within a unified control environment.

Mahl, Johannes [Lawrence Berkeley National Laborat↗

Modeling the Ex-core Detector Response into a Production Option in MPACT

In the past few years, the Consortium for Advanced Simulation of Light Water Reactors (CASL) has overseen a successful activity to extend the radiation transport capability from the reactor in-core geometry to the ex-core geometry by coupling the deterministic neutronics code MPACT, with the Monte Carlo code Shift. However, transient problems such as RIAs require an efficient prediction of the ex-core detector response to determine the timeframe for a reactor trip. Therefore, in addition to the high-fidelity MPACT-Shift coupled calculation, separate efforts have been made to explore simplified methods for ex-core detector response with MPACT standalone calculation. In a previous milestone L3_RTM.MCH.P17.06, several simplified methods for ex-core detector response were developed in MPACT. In particular, the double kernel method is based on the default MPACT core geometry, so extensive modeling or transport calculation with full reflector and ex-core details are not needed in this method. Since the 1-D diffusion and neutron streaming kernels are used for extended ex-core calculations, the extra computational efforts are very small. The work implemented in the current milestone provides a fully integrated option for MPACT to approximately calculate the ex-core detector response using the double kernel method. To overcome the difficulty of obtaining the consistent diffusion coefficients (these were obtained through separate CMFD calculation and edits), the 1-D diffusion solver is replaced by a 1-D Sn transport solver to compute the neutron flux at the vessel outer surface. The new VERA inputs for ex-core detector are processed in MPACT. The detector signals are linked to the SCRAM logic as an option to trip the core during transient calculation. Two sets of 3-D quarter core problems are run with MPACT standalone and VeraShift to verify the radial and axial effects on detector response by varying the moderator density and control rod position. For the cases with moderator density changes, the detector responses from MPACT are within 2 sigma error of VeraShift. For the cases at different control rod positions, the axial offsets computed from MPACT are within 2% error of VeraShift results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record↗

Modeling Chandra Space Environment

This paper describes the development of an environmental risk-mitigation tool for the Chandra X-ray Observatory's Advanced CCD Imaging Spectrometer (ACIS). Because exposure to 100-200 keV protons appears to have degraded the front-illuminated CCD's charge transfer inefficiency (CTI), an accurate tool for predicting encounters with magnetospheric regions rich in these particles is required. We implement standard models to predict bow-shock, magnetopause, and plasma-sheet boundaries. Using these models and solar-wind databases compiled from IMP-8 and ACE measurements, we then calculate the probability that Chandra is located in one of these regions, along with predicted particle flux, to arrive at appropriate safing times for the ACIS detector. Finally, we validate this tool by comparing the model's boundary-crossing and proton flux predictions with measurements from Chandra's on-board particle detector and with data from other spacecraft operating in the Earth's magnetosphere.

Blackwell, W. C.↗

Alpha-Imaging Detector System Development for Large Area Monitoring

Effective management and disposal of legacy nuclear waste are essential for ensuring safe work environments and minimizing environmental impacts. Monitoring airborne actinide contamination is particularly critical due to the high internal dose potential of alpha-emitting radionuclides. Traditional continuous air monitoring systems (CAMs) used in the industry are limited in the volume of air they can sample, potentially leading to inaccurate radiation detection over large areas. For example, in 2018, elevated levels of airborne Plutonium-239 were detected beyond the controlled areas of the Hanford Plutonium Finishing Plant, highlighting the potential risks to both plant workers and nearby residents. To address these challenges, high-efficiency particulate absorbing (HEPA) air purifiers can enhance air flow by up to 1.5 orders of magnitude, thereby increasing monitoring efficiency and providing a cost-effective solution for large-area surveillance. To quantify the activities of alpha-emitting radionuclides on HEPA filters, the Savannah River National Laboratory is developing an advanced alpha-imaging detection system. This system includes scintillating materials combined with a digital scientific camera. A significant concern in operating such a large-area airborne monitoring system is the handling of HEPA filters, which may be contaminated with radioactive particles. To mitigate these hazards, it is crucial to ensure that any contamination is securely fixed onto the filters. Efforts have been made to optimize the sensitivity of scintillator-epoxy composites and apply them to HEPA filters. These materials were characterized using fluoroscence spectroscopy. These techniques confirmed the purity of the raw materials, the dispersion of scintillators in the epoxy matrix, and the stability of their optical and structural properties post-modification. The optimal scintillator-epoxy composite was selected for use on alpha-spiked HEPA filters to evaluate the efficiency of the sprayer. HEPA filters, embedded with alpha particles collected by an air purifier deployed in an airborne radiation area, have been tested to assess detection efficiency. Future work will focus on employing multiple imaging sensors simultaneously to enhance sensitivity across different regions of the HEPA filter.

Pham, Phuong [Savannah River National Laboratory (↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Towards High-Efficiency Particle Detection Using Superconducting Microwire Arrays

We present a detailed study of an 8-channel $1\times1$~mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120~GeV hadron beam and 120~GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3~nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7~nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10~$\mu$m in situ spatial resolution. The results show a detection efficiency of 75\% and a time resolution of about 130~ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Wang, Christina [Fermilab]↗