Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Incentive-Based Control and Coordination of Distributed Energy Resources. Final Report

The rapid growth of low-inertia renewable energy resources represents an immense opportunity for the U.S. to minimize its carbon footprint, while presenting a challenge for system operators as traditional “spinning” generation resources are displaced. This transformation requires solutions to robustly and cost-effectively manage dynamic changes on the grid while ensuring quality of service. There is growing recognition that distributed energy resources (DERs – loads, distributed generation, storage, electric vehicles, etc.) represent a great potential to perform this function. This report details a scalable hierarchical control strategy for coordinating thousands of heterogeneous DERs in order to provide three ancillary gird services: 1) frequency response, a rapid (within 2 seconds) service used to maintain the grid at 60 Hz; 2) regulation response, a larger response used to balance on-going differences in supply and demand on the grid; and, 3) ramping reserve, used to bring on capacity to replace lost generation. The developed control architecture consists of 1) a Distribution Reliability Coordinator (DRC), 2) aggregator controllers, and finally, 3) DER controllers. The DRC coordinates all the flexible loads and distributed energy resources on the distribution system and bids the aggregate flexibility into the wholesale market. The DRC also performs resource allocation (deciding how the flexible devices on the distribution system will be dispatched) to meet the requirements for each of the three ancillary services. The aggregators control a collection of devices that are geographically co-located and provide a platform to aggregate their flexibility and mitigate uncertainty associated with a single flexible load by managing a large aggregation of similar loads (so that any stochastic effects average out). Finally, DER controllers (for example, thermostats for air conditioners, chargers for electric vehicles) adjust the power consumption of individual devices to ensure accurate and reliable delivery of the requested grid services. Evaluation and validation of this approach was conducted with a mixture of simulation and hardware testing for a range of DERs in residential (air conditioners and water heaters), commercial HVAC (ventilation fans and central chiller plants), and micro-grids (battery energy storage, solar PV etc.). This culminated in DER hardware and simulation models operating in conjunction with grid simulations as part of a large scale federated test-bed demonstration. Simulations of over 10,000 controllable residential devices (a combination of air conditioners, water heaters, batteries, and electric vehicles) demonstrated that this advanced control approach could simultaneously meet all three grid services. Furthermore, hardware-in-the-loop testing was performed with operational micro-grid and commercial building HVAC equipment. The micro-grid equipment (representing PV, battery storage, and back-up generators) demonstrated the ability to meet all frequency response requirements (except ramping time). The commercial building HVAC ventilation equipment successfully provided the regulating response service. An Industry Advisory Board (IAB) was formed and engaged throughout the project to get feed-back on project risks and potential commercialization barriers. Their input was invaluable in identify key risks stemming from regulatory and market access challenges, financial risks from under-performance, and competitive threats from utility-scale solutions such as integrated storage. A phased commercialization plan was developed that addresses continued risk reduction (value proposition refinement and performance uncertainty assessments), piloting through field demonstrations with key stakeholders, and finally, deployment as an emerging standard for DER control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrolyte and Cutoff Potential Effects on Cycle Life of Li4Ti5O12/LiNi0.9Mn0.1O2 Batteries for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) is a stationary battery energy storage system that is connected to the electrical distribution system on the customer's side of the utility's service meter. BTMS systems are used to store electrical energy from the grid as well as inconstant, renewable energy, such as local solar and wind generation. A successful BTMS system will allow the customer to pair their energy generation and storage to optimize electrical consumption from the grid, improving reliability and minimizing cost. For BTMS applications, batteries must be designed and optimized with different set of criteria from other leading segments of the Li-ion battery market, like transportation, due the system being stationary and proximal to the residential or commercial building it's benefitting. BTMS applications prioritize safety, cost (low/no-critical materials), reliability (20-year calendar life), and durability (10,000 cycle life), while having the ability to (minimally) compromise energy density and rate capability. Lithium titanate (Li4Ti5O12-, LTO) is a promising anode candidate for BTMS applications due to its high safety and capacity retention, while maintaining a reasonable 160 mAhg-1 reversable capacity and composition of relatively abundant materials. (1) Specifically, LTO has a high working voltage which helps to prevent Li dendrite formation, improving safety. Furthermore, LTO also has negligible lithiation-based volume change, leading to less mechanical pulverization, or loss of active material, upon cycling. For the cathode, materials with little or no Co are of high interest due to the high cost and low abundance of Co. LiMn2O4 (LMO) has been paired with LTO for BTMS applications in the past due to its safety, low cost (abundancy), and reasonably high operating voltage. (2-4) However, the low capacity of LMO limits energy density and specific energy. While not the highest priority for BTMS applications, increasing energy density will enable deployment in space constrained BTMS applications and decrease total cost. LiNi0.9Mn0.1O2 (LN-MO) is a recently developed material with promise due to its high operating voltage and relatively low price. (5) However, Ni-rich layered oxides, including LNMO, tend to struggle with capacity retention during high-voltage cycling due to mechanical pulverization, irreversible phase transitions, and unstable solid-electrolyte interphase. The study presented here focuses on building an understanding of how electrolyte solvent and varied cutoff potentials will impact the cycle life of LTO/LN-MO cells. Specifically, a comparison is provided between ethylene carbonate (EC), ethyl methyl carbonate (EMC), fluoroethylene carbonate (FEC), and Gen2 electrolyte solvents with 1M Lithium hexafluorophosphate (LiPF6) salt, cycling to two upper termination potentials, 2.6V and 2.7V. Electrochemical testing and diagnostics (e.g., differential capacity analysis, area specific impedance, constant voltage hold, and rate capability) and post-mortem characterization will be used to understand the aging behavior and failure mechanisms of the 8 cell combinations (four electrolytes and two voltage cutoffs). Cells with FEC electrolyte showed a lower initial capacity compared to cells with Gen2, EMC, and EC cycling at both voltages; however, the cells with FEC showed consistent trends in capacity retention with 2.6V and 2.7V termination potentials, while the cells with the other electrolytes showed much higher rates of capacity loss when cycling to the higher voltage. These results indicate that FEC may play a role in improving durability of high-voltage, Ni-rich electrode systems for use in high-cycle applications, such as BTMS.

electrolyte↗

Real-time hybrid controls of energy storage and load shedding for integrated power and energy systems of ships

This paper presents an original energy management methodology to enhance the resilience of ship power systems. The integration of various energy storage systems (ESS), including battery energy storage systems (BESS) and super-capacitor energy storage systems (SCESS), in modern ship power systems poses challenges in designing an efficient energy management system (EMS). The EMS proposed in this paper aims to achieve multiple objectives. The primary objective is to minimize shed loads, while the secondary objective is to effectively manage different types of ESS. Considering the diverse ramp-rate characteristics of generators, SCESS, and BESS, the proposed EMS exploits these differences to determine an optimal long-term schedule for minimizing shed loads. Furthermore, the proposed EMS balances the state-of-charge (SoC) of ESS and prioritizes the SCESS’s SoC levels to ensure the efficient operation of BESS and SCESS. For better computational efficiency, we introduce the receding horizon optimization method, enabling real-time EMS implementation. Further, a comparison with the fixed horizon optimization (FHO) validates its effectiveness. Simulation studies and results demonstrate that the proposed EMS efficiently manages generators, BESS, and SCESS, ensuring system resilience under generation shortages. Additionally, the proposed methodology significantly reduces the computational burden compared to the FHO technique while maintaining acceptable resilience performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrochemical Energy Storage for Green Grid

The is a comprehensive review on the needs and potential storage technologies for electrical grid that is expected to integrate significant levels of renewables. This review offers details of the technologies, in terms of needs, status, challenges and future R&d directions.

25 ENERGY STORAGE↗

Energy Storage Sizing Taking Into Account Forecast Uncertainties and Receding Horizon Operation

Energy storage systems (ESS) have the potential to be very beneficial for applications such as reducing the ramping of generators, peak shaving, and balancing not only the variability introduced by renewable energy sources, but also the uncertainty introduced by errors in their forecasts. Optimal usage of storage may result in reduced generation costs and an increased use of renewable energy. However, optimally sizing these devices is a challenging problem. This paper aims to provide the tools to optimally size an ESS under the assumption that it will be operated under a model predictive control scheme and that the forecast of the renewable energy resources include prediction errors. A two-stage stochastic model predictive control is formulated and solved, where the optimal usage of the storage is simultaneously determined along with the optimal generation outputs and size of the storage. Wind forecast errors are taken into account in the optimization problem via probabilistic constraints for which an analytical form is derived. This allows for the stochastic optimization problem to be solved directly, without using sampling-based approaches, and sizing the storage to account not only for a wide range of potential scenarios, but also for a wide range of potential forecast errors. In the proposed formulation, we account for the fact that errors in the forecast affect how the device is operated later in the horizon and that a receding horizon scheme is used in operation to optimally use the available storage.

25 ENERGY STORAGE↗

Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

The Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems (PNNL-22010) was first issued in November 2012 as a first step toward providing a foundational basis for developing an initial standard for the uniform measurement and expression of energy storage system (ESS) performance. Based on experiences with the application and use of that document, and to include additional ESS applications and associated duty cycles, test procedures and performance metrics, a first revision of the November 2012 Protocol was issued in June 2014 (PNNL 22010 Rev. 1). As an update of the 2014 revision 1 to the Protocol, this document (the March 2016 revision 2 to the Protocol) is intended to supersede the June 2014 revision 1 to the Protocol and provide a more user-friendly yet more robust and comprehensive basis for measuring and expressing ESS performance.

25 ENERGY STORAGE↗

Deployment of Energy Storage to Improve Environmental Outcomes of Hydropower

This paper describes how the installation of energy storage systems, co-sited with hydroelectric projects, can offer both economic and environmental benefits by enabling a broader range of electricity performance, capitalizing on its flexibility and grid reliability, while mitigating critical environmental impacts or improving environmental outcomes across U.S. rivers and streams. The paper attempts to link environmental outcomes to energy storage utilization. It offers a comprehensive inventory of research-grade work, site-specific studies, policies, and pilot projects regarding energy storage and hydropower that show significant environmental implications. It provides an outline of methodologies given the known costs and attributes of storage technologies, with case study illustrations. It outlines the key components of a methodology that could be applied within the context of specific projects to reveal the environmental benefits of energy storage paired with hydropower production to properly size the storage systems to seize benefits. The actual methodology would be developed in future work. Finally, we provide a set of gaps to be addressed in future work as this important idea gains traction.

13 HYDRO ENERGY↗

Valuing the Future Electric Grid: A Bid-Based Approach

Energy storage resources (ESRs) and other zero marginal cost (ZMC) resources have unique characteristics that are not fully captured in today’s electricity planning and operations modeling tools. Because the modeling assumptions used in these tools are simplified approximations of how operations and investment decisions occur in the real-world, accurately representing cost and operational characteristics are key for determining how these resources impact price formation. Questions such as—Where should we build new transmission? Will a small modular reactor earn enough revenue to participate in the future electric grid? Is retrofitting a coal plant with carbon capture technology economically feasible?—all require accurate electricity prices, which aren’t available from today’s electricity planning and operations modeling tools. As an example, production cost models (PCMs) are heavily utilized tools that determine the cost and reliability of the electric system. However, as PCMs were developed to help thermal generators manage their fuel inventories, production cost modeling is largely based on fuel prices. Because ESRs do not incur fuel costs, they are often modeled as ZMC resources. In reality, ESRs incur opportunity costs as well as technology-specific (degradation) costs that are non-trivial to calculate but are important for price formation. In this research, we identify options to incorporate more realistic opportunity and degradation costs in ESR bidding algorithms. Expanding available bidding assumptions allows energy system modelers to develop more accurate economic valuations for ESRs, leading to more accurate price formation from leading energy system modeling tools.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Supercharge NY

The Energy Program for Innovation Clusters (EPIC) Supercharge NY enabled The Clean Fight to execute an inaugural accelerator program focused on enabling world-class, growth-stage energy storage companies to successfully scale deployments and establish domestic manufacturing pathways in New York State. The Clean Fight has developed and tested a successful accelerator model designed to reduce the barriers growth-stage climate tech companies face by collapsing the sales cycle to scaling solutions at speed. The Clean Fight’s Supercharge NY project allowed for the exploration into the understanding of New York-focused energy storage opportunities, challenges, and methods for enabling successful projects. The Clean Fight’s Supercharge NY project enabled high-touch matchmaking with industry leading customer and capital partners, technical assistance to facilitate scaling supply chain and manufacturing capacity, and access to non-dilutive funding for first-of-a-kind or demonstration projects in New York State. The results of the program provide a public benefit by accelerating deployments of energy storage to provide value-added energy services and sustainability benefits to communities while boosting economic opportunity and job creation for all.

25 ENERGY STORAGE↗

Slocum-TREC Thermal Glider

JPL is now teaming with Teledyne-Webb-Research to produce the first thermal glider that uses PCM for direct buoyancy control (not electronic pumps) and to produce all other required electricity. TWR has increased electrical production total efficiency from 0.45 to 0.61. JPL performed over 6000 cycles (2.4 years) of accelerated life testing of a piston accumulator. Design, fabrication, and testing will be performed in 2012, with deployment by Rutgers University in late 2012. The proposed goal of the ocean endurance tests was 3 months, but will be extended to at last 1 year. The piston accumulator was cycled over 6,000 times in a three-month period in order to simulate continuous glider life of about 2.4 years, The life test data suggests that we might accumulate roughly 0.5 cc of gas in the oil bladders for each cycle. PCM canisters will be fabricated with a compressed aluminum foam core, 7.5% foam selected (< 42 minutes to freeze anticipated) An Axi 5345/18 3-Phase AC alternator selected for power generation, 61% energy storage efficiency A 4-Cell A123 Energy Storage Systems battery selected for energy storage, buss voltage 14.4 to 12.5 V (13.2 V nominal) Glider deployment expected in late 2012

energy harvesting↗

Employee Spotlight: Michael Slater

This is a spotlight on an employee at Argonne National Laboratory, Michael Slater, and his research which focuses on energy storage technologies.

25 ENERGY STORAGE↗

Increasing Flexibility of ROR Hydropower Plants using "Virtual Reservoirs"

The U.S. power system is going through significant shifts in the value of energy and services, largely driven by increased generation in intermittent renewables (e.g, wind and solar). The increased utilization of these resources is shifting power markets and requiring other participants to consider changes in their operations to meet market needs. A large stock of existing run-of-river (ROR) hydropower infrastructure in the U.S. (29% of all hydropower capacity in the U.S.) is ROR, without the flexibility to regulate operations independent of daily water flows. This research is assessing the potential of integrated hybrid energy storage systems (HESS) as virtual reservoir for ROR flexibility enhancement. Different combinations of high energy storage (e.g., battery) and high power storage (e.g., flywheel, supercapacitor) devices with single/multi converter configuration are being considered for ROR integration. This poster summarizes the various ancillary services that are being investigated for all possible ROR integrated HESS configurations.

13 HYDRO ENERGY↗

A High-Performance Sintered Iron Electrode for Rechargeable Alkaline Batteries to Enable Large-Scale Energy Storage

Iron-based alkaline rechargeable batteries such as iron-air and nickel-iron batteries are particularly attractive for large-scale energy storage because these batteries can be relatively inexpensive, environment- friendly, and also safe. Therefore, our study has focused on achieving the essential electrical performance and cycling properties needed for the widespread use of iron-based alkaline batteries in stationary and distributed energy storage applications.We have demonstrated for the first time, an advanced sintered iron electrode capable of 3500 cycles of repeated charge and discharge at the 1-hour rate and 100% depth of discharge in each cycle, and an average Coulombic efficiency of over 97%. Such a robust and efficient rechargeable iron electrode is also capable of continuous discharge at rates as high as 3C with no noticeable loss in utilization. We have shown that the porosity, pore size and thickness of the sintered electrode can be selected rationally to optimize specific capacity, rate capability and robustness. As a result, these advances in the electrical performance and durability of the iron electrode enables iron-based alkaline batteries to be a viable technology solution for meeting the dire need for large-scale electrical energy storage.

25 ENERGY STORAGE↗