Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Comparison of techniques for measuring +Gz tolerance in man

Two objective methods and one subjective method for measuring +Gz tolerance (inertial vector in a head-to-foot direction) were compared on the human centrifuge. Direct eye-level blood pressure (Pa), blood flow velocity in the superficial temporal artery (Qta), and subjective visual symptoms were used to determine tolerance to rapid-onset acceleration (1 G/s) on the USAFSAM human centrifuge. Seven 'relaxed' subjects with extensive centrifuge experience were exposed to gradually increasing +Gz plateaus until the subject reported 100% loss of peripheral centrifuge gondola lights (PLL) and 50% loss of central light (CLD); viz., blackout. Zero forward Qta occurred 6 s (range 4-9 s) before subjective blackout and when mean eye-level blood pressure had reached 20 + or - 1 mm Hg (SE). The results of this study indicate that flow changes in the superficial temporal artery reflect flow changes in the retinal circulation during +Gz stress.

Krutz, R. W., Jr.↗

Techniques for measuring bulk gas-motions from satellites

There is a growing appreciation for the dynamic nature of the upper atmosphere. This paper is concerned principally with discussing the methods for making in-situ measurements of the ambient gas velocities from satellites. Both neutral and ion instrumentation is discussed, but most attention is paid to the ion sensors on Atmosphere-Explorer-C, which are now providing the first detailed three-dimensional gas-velocity measurements from a satellite. While some data are presented, emphasis is placed on experimental difficulties and possible ways of alleviating these problems. It seems reasonable to expect that both neutral and ion gas velocities will be measured to an accuracy of the order of 20 m/s in future satellites, provided that a star tracker is available for the determination of vehicle attitude. The possible exception to this is the ram component of the neutral-gas velocity vector, for which no proven instrumentation yet exists.

Hanson, W. B.↗

Optical technique for measurement of random water wave surfaces

An optical system using the refraction of a vertical light ray has been developed for measuring the slope of random wind-generated water waves. The basic elements of the system are photovoltaic cells which are connected to individual amplifiers so that when the refracted light beam is incident on a cell, the output of the cell is amplified and then supplied as input to a comparator. The comparator then provides a specified voltage output, independent of the incident light intensity, as long as it is above a designated background value. The comparators are designed to give output voltages comparable with standard TTL. This arrangement provides a high signal from the cell when it experiences incident light, and a low signal when there is only background light, with the high and low signals at TTL voltage levels.

Sorrell, F. Y.↗

Experimental verification of the technique for measurement of ablation on the GASJET nose tip

The GASJET nose tip is proposed to reduce the erosion at the apex of a missile nose flying at hypersonic speeds through a rain storm as it reenters the atmosphere. A forward facing sonic jet is directed through the tip introducing a secondary counter-flow which displaces the bow shock and blankets the tip with a protective layer of relatively cool gas. Wind tunnel experiments are described which proved the validity of measuring nose recession in flight by recording the pressure in the blast tube supplying the GASJET.

Donohoe, J. C.↗

Extinction-sedimentation inversion technique for measuring size distribution of artificial fogs

In measuring the size distribution of artificial fog particles, it is important that the natural state of the particles not be disturbed by the measuring device, such as occurs when samples are drawn through tubes. This paper describes a method for carrying out such a measurement by allowing the fog particles to settle in quiet air inside an enclosure through which traverses a parallel beam of light for measuring the optical depth as a function of time. An analytic function fit to the optical depth time decay curve can be directly inverted to yield the size distribution. Results of one such experiment performed on artificial fogs are shown as an example. The forwardscattering corrections to the measured extinction coefficient are also discussed with the aim of optimizing the experimental design so that the error due to forwardscattering is minimized.

Deepak, A.↗

Electron emission from nickel-alloy surfaces in cesium vapor

An experimental apparatus and measurement techniques are described for measuring the thermionic emission from cesium-activated materials having adequate high-temperature properties such as creep strength and corrosion resistance, which might ultimately reduce the cost of thermionic converters. The electron emission characteristics are measured for nickel, Inconel 600, and Hastelloy X probes with a 412 K cesium reservoir. It is found that the nickel alloys exhibit a peak electron emission 1.4 to 2.1 times greater than pure nickel. Both the Inconel and the Hastelloy samples have work functions of 1.64 eV at peak emission. The minimum cesiated work functions are estimated to be 1.37 eV for Inconel at a probe temperature of 750 K and 1.4 eV for Hastelloy at a probe temperature of 665 K. The bare work functions for both alloys is estimated to be about the same as for pure nickel, 4.8 eV.

Manda, M.↗

A technique for measuring in situ size distribution of aerosols

A multistage cascade impactor instrument employing piezoelectric crystals for real-time aerosol size distribution measurements is described in this paper. The instrument measures the aerosol mass concentration as a function of particle size in 10 size intervals ranging from 0.05 micrometers to 25 micrometers in diameter. The particles are then analyzed for elemental composition and morphology by means of scanning electron microscopy (SEM). Examples of particle size distributions in rocket motor exhaust plumes measured with the instrument are presented together with the elemental composition and morphology obtained by SEM.

Woods, D. C.↗

A two satellite technique for measuring atmospheric surface pressure

A two-satellite system configuration is designed in which one satellite transmits a signal which is reflected from the sea surface and received by the other satellite. The time delay of the signal is measured. By selecting the geometry such that the signal path makes a small grazing angle with the sea surface, the amount of troposphere passed through and hence the magnitude of the tropospheric effect is maximized; requirements on timing accuracy are thus relaxed. The vacuum path length of the radar signals must be subtracted from the measured path length in order to compute the tropospheric effect, which is highly correlated to the atmospheric surface pressure. This is done by measuring the time delays along three additional paths. The use of an operational constellation of several satellites further decreases sensitivity to geoidal errors.

Goldfinger, A. D.↗

A Scanning laser-velocimeter technique for measuring two-dimensional wake-vortex velocity distributions

A rapid scanning two dimensional laser velocimeter (LV) has been used to measure simultaneously the vortex vertical and axial velocity distributions in the Langley Vortex Research Facility. This system utilized a two dimensional Bragg cell for removing flow direction ambiguity by translating the optical frequency for each velocity component, which was separated by band-pass filters. A rotational scan mechanism provided an incremental rapid scan to compensate for the large displacement of the vortex with time. The data were processed with a digital counter and an on-line minicomputer. Vaporized kerosene (0.5 micron to 5 micron particle sizes) was used for flow visualization and LV scattering centers. The overall measured mean-velocity uncertainity is less than 2 percent. These measurements were obtained from ensemble averaging of individual realizations.

Gartrell, L. R.↗

Investigation of remote sensing techniques of measuring soil moisture

Major activities described include development and evaluation of theoretical models that describe both active and passive microwave sensing of soil moisture, the evaluation of these models for their applicability, the execution of a controlled field experiment during which passive microwave measurements were acquired to validate these models, and evaluation of previously acquired aircraft microwave measurements. The development of a root zone soil water and soil temperature profile model and the calibration and evaluation of gamma ray attenuation probes for measuring soil moisture profiles are considered. The analysis of spatial variability of soil information as related to remote sensing is discussed as well as the implementation of an instrumented field site for acquisition of soil moisture and meteorologic information for use in validating the soil water profile and soil temperature profile models.

Newton, R. W.↗

Techniques for measurements of horizontal and vertical velocities

Spectrum analysis and correlation methods used to measure the horizontal and vertical velocities of radar echo signals are examined mathematically. Topics include scattering/reflection geometry, monostatic versus bistatic operation, spaced antenna measurements, radar interferometry and the Doppler method. Vertical velocity determination, optimum pointing angles, and time resolution for periodic variations are also investigated.

Rottger, J.↗

A new technique for measuring sputtering yields at high energies

The use of thin, self-supporting carbon catcher foils allows one to measure sputtering yields in a broad range of materials with high sensitivity. Analyzing the foils with Rutherford forward scattering, sputtered Al, Si and P surface densities down to 5 x 10 to the 13th per sq cm with uncertainties of about 20 percent have been measured.

Qiu, Y.↗

Assessment of Techniques for Measuring Tropospheric H Sub x O Sub y

In its continuing efforts to direct its applications programs towards relevant national needs, NASA is conducting the Tropospheric Chemistry Program, the long-range objective of which is to apply NASA's space technology to assess and predict human impact on the troposphere, particularly on the regional to global scale. One area of required research is instrumentation development, which is aimed at improving the capability to measure important trace gases and aerosols which are key species in the major atmospheric biogeochemical cycles. To focus on specific needs, the Instrumentation Worksphop for H(x)O(y) Tropospheric Species was conducted in August 1982. The workshop discussed current measurement needs and instrument capabilities for H(x)O(y) species, including OH, HO2, and H2O2. The workshop activities and conclusions are documented.

Hoell, J. M.↗

Techniques for measuring intercepted and absorbed PAR in corn canopies

The quantity of radiation potentially available for photosynthesis that is captured by the crop is best described as absorbed photosynthetically active radiation (PAR). Absorbed PAR (APAR) is the difference between descending and ascending fluxes. The four components of APAR were measured above and within two planting densities of corn (Zea mays L.) and several methods of measuring and estimating APAR were examined. A line quantum sensor that spatially averages the photosynthetic photon flux density provided a rapid and portable method of measuring APAR. PAR reflectance from the soil (Typic Argiaquoll) surface decreased from 10% to less than 1% of the incoming PAR as the canopy cover increased. PAR reflectance from the canopy decreased to less than 3% at maximum vegetative cover. Intercepted PAR (1 - transmitted PAR) generally overestimated absorbed PAR by less than 4% throughout most of the growing season. Thus intercepted PAR appears to be a reasonable estimate of absorbed PAR.

Gallo, K. P.↗

Use of the VAD technique and measurements of momentum flux in the stratosphere at Aercibo, part 4.3A

The Arecibo 430-MHz radar was used in the velocity-azimuth display (VAD) mode to obtain radial velocity measurements at 16 azimuth directions from which the three-dimensional wind field and momentum flux can be calculated. The radar was operated on a nearly continuous basis for a seven-day period in May of 1982 and the elapsed time between start and finish of a VAD scan was approximately 35 minutes. Radial velocities were measured in the upper troposphere and lower stratosphere (6-24 km) with at height resolution of 150 meters at a zenith angle of 15 deg. Vertical and horizontal velocities are calculated from the sums and differences, respectively, of radial velocity pairs, i.e., at azimuth directions AZ and AZ + 180 degrees. Momentum flux at a particular azimuth is calculated by taking the difference between the square of radial velocities at AZ and AZ + 180 degrees. It should be noted that measurements of radial velocity pairs are not simultaneous but are time delayed by approximately 15-25 minutes. This period, the time required to rotate the antenna feed and take measurements at AZ and AZ + 180 deg, effectively limits sampling of velocities and momentum fluxes to longer period gravity waves and planetary waves.

Cornish, C. R.↗

A technique to measure the size of particles in laser Doppler velocimetry applications

A method to measure the size of particles in Laser Doppler Velocimeter (LDV) applications is discussed. Since in LDV the velocity of the flow is assocated with the velocity of particles to establish how well they follow the flow, in the present method the interferometric probe volume is surrounded by a larger beam of different polarization or wavelength. The particle size is then measured from the absolute intensity scattered from the large beam by particles crossing the fringes. Experiments using polystrene particles between 1.1 and 3.3 microns and larger glass beads are reported. It is shown that the method has an excellent size resolution and its accuracy is better than 10% for the particle size studied.

Hess, C. F.↗

Technique for measuring gas conversion factors

A method for determining hydrocarbon conversion factors for a flowmeter. A mixture of air, O2 and C sub x H sub y is burned and the partial paressure of O2 in the resulting gas is forced to equal the partial pressure of O2 in air. The flowrate of O2 flowing into the mixture is measured by flowmeter and the flowrate of C sub x H sub y flowing into the mixture is measured by the flowmeter conversion factor is to be determined. These measured values are used to calculate the conversion factor.

Singh, J. J.↗

Technique for measuring side forces on a banked aircraft with a free-swiveling nose gear

An experimental investigation was conducted at the Langley Research Center to determine a method for towing an aircraft to measure the side forces of a free-swiveling nose gear due to variations in bank angle. A F-106 aircraft and the Space Shuttle orbiter OV-101 were towed to measure side forces on full-size aircraft for bank angles up to 3 deg. These tests indicate that substantial side forces will occur if an aircraft is rolling on a runway in a banked attitude even when the nose gear is free to swivel. Corotation of a twin-tire nose gear appears to cause a substantial increase in side force due to bank angle compared with a nose gear with indepdendently rotating wheels.

Stubbs, S. M.↗