A small, single stage orifice pulse tube cryocooler demonstration

This final report summarizes and presents the analytical and experimental progress in the present effort. The principal objective of this effort was the demonstration of a 0.25 Watt, 80 Kelvin orifice pulse tube refrigerator. The experimental apparatus is described. The design of a partially optimized pulse tube refrigerator is included. The refrigerator demonstrates an ultimate temperature of 77 K, has a projected cooling power of 0.18 Watts at 80 K, and has a measured cooling power of 1 Watt at 97 K, with an electrical efficiency of 250 Watts/Watt, much better than previous pulse tube refrigerators. A model of the pulse tube refrigerator that provides estimates of pressure ratio and mass flow within the pulse tube refrigerator, based on component physical characteristics is included. A model of a pulse tube operation based on generalized analysis which is adequate to support local optimization of existing designs is included. A model of regenerator performance based on an analogy to counterflow heat exchangers is included.

Hendricks, John B.↗

An Emergent Conductivity Relationship for Water Flow Based on Minimized Dissipation: From Landscapes to Unsaturated Soils

Optimality principles have been widely used in many areas. Based on an optimality principle that a flow field will tend toward a minimum in the energy dissipation rate, this work shows that there exists a unified form of conductivity relationship for two different flow systems: landscapes and unsaturated soils. The conductivity, the ratio of water flux to water head (energy) gradient, is a power function of water flux where the exponent value is system dependent. This relationship indicates that to minimize energy dissipation rate for a whole system, water flow has a small resistance (or a large conductivity) at a location of large water flux. Empirical evidence supports validity of the relationship for landscape and unsaturated soils (under gravity dominated conditions). Especially, it is of interest that according to this relationship, hydraulic conductivity for gravity-dominated unsaturated flow, unlike that defined in the classic theories, depends on not only capillary pressure (or saturation), but also the water flux. Use of the optimality principle allows for determining useful results that may be applicable to a broad range of areas involving highly non-linear processes and may not be possible to obtain from classic theories describing water flow processes.

54 ENVIRONMENTAL SCIENCES↗

FLOWERS AEP: An Analytical Model for Wind Farm Layout Optimization

Annual energy production (AEP) is commonly used in objective functions for wind farm layout optimization. AEP is proportional to wind farm power production integrated over an annual distribution of free-stream wind conditions. Physics-based estimates of wind farm power production typically rely on low-fidelity engineering wake models that approximate the steady-state wind farm flow field. AEP estimates are then obtained by performing independent simulations for discrete wind conditions and using rectangular quadrature to account for each condition's expected frequency of occurrence. Depending on the number of simulated discrete wind conditions, this numerical integral could be hampered by poor accuracy or high computational costs. The FLOWERS AEP model instead poses an analytical integral of the engineering wake model over the variable wind conditions, yielding a closed-form, analytical function for wind farm AEP. This paper derives the analytical functions for FLOWERS AEP and its derivatives with respect to turbine position, which are useful for gradient-based wind farm layout optimization, in nondimensional form. We then analyze the benefits of the FLOWERS AEP model over conventional reference models, focusing on its low cost, adequate wake loss predictions, and smooth design space. Although the FLOWERS approach is found to predict the exact value of AEP with some error relative to the reference model (within 14% on average), it dramatically reduces computation time by an order of magnitude, produces a qualitatively similar design space at relatively low resolution, and yields comparable optimal layouts. This significant speed improvement is critical in layout optimization applications, where determining an optimal layout in an efficient manner is more important than precise AEP prediction.

17 WIND ENERGY↗

A one-dimensional transient model of a single-stage, downward-firing entrained-flow gasifier

The integrated gasification combined cycle (IGCC) technology has emerged as an attractive alternative to conventional coal-fired power plant technology due to its higher efficiency and cleaner environmental performance especially with the option of CO{sub 2} capture and sequestration. The core unit of this technology is the gasifier whose optimal performance must be understood for efficient operation of IGCC power plants. This need has led a number of researchers to develop gasifier models of varying complexities. Whereas high-fidelity CFD models can accurately predict most key aspects of gasifier performance, they are computationally expensive and typically take hours to days to execute on high-performance computers. Therefore, faster one-dimensional (1D) partial differential equation (PDE)-based models are required for use in dynamic simulation studies, control system analysis, and training applications. A number of 1D gasifier models can be found in the literature, but most are steady-state and have limited application in the practical operation of the gasifier. As a result, 1D PDE-based dynamic models are needed to further study and predict gasifier performance under a wide variety of process conditions and disturbances. In the present study, a 1D transient model of a single-stage downward flow GE/Texaco-type gasifier has been developed. The model comprises mass, momentum and energy balances for the gas and solid phases. The model considers the initial gasification processes of water evaporation and coal devolatilization. In addition, the key heterogeneous and homogeneous chemical reactions have been modeled. The resulting time-dependent PDE model is solved using the well-known method of lines approach in Aspen Custom Modeler®, whereby the PDEs are discretized in the spatial domain and the resulting differential algebraic equations (DAEs) are then solved to obtain the transient response. The transient response of various gasifier performance parameters to certain disturbances commonly encountered in the real world operation of commercial IGCC plants will be presented. These disturbances include ramp and step changes in input variables such as coal flow rate, oxygen-to-coal ratio and water-to-coal ratio, among others. Comparison of gasifier model predictions to available dynamic data will also be discussed.

97 MATHEMATICS AND COMPUTING↗

Optimization of current waveform tailoring for magnetically driven isentropic compression experiments

The Thor pulsed power generator is being developed at Sandia National Laboratories. The design consists of up to 288 decoupled and transit time isolated capacitor-switch units, called “bricks,” that can be individually triggered to achieve a high degree of pulse tailoring for magnetically driven isentropic compression experiments (ICE) [D. B. Reisman et al., Phys. Rev. Spec. Top.–Accel. Beams 18, 090401 (2015)]. The connecting transmission lines are impedance matched to the bricks, allowing the capacitor energy to be efficiently delivered to an ICE strip-line load with peak pressures of over 100 GPa. Thor will drive experiments to explore equation of state, material strength, and phase transition properties of a wide variety of materials. We present an optimization process for producing tailored current pulses, a requirement for many material studies, on the Thor generator. This technique, which is unique to the novel “current-adder” architecture used by Thor, entirely avoids the iterative use of complex circuit models to converge to the desired electrical pulse. We begin with magnetohydrodynamic simulations for a given material to determine its time dependent pressure and thus the desired strip-line load current and voltage. Because the bricks are connected to a central power flow section through transit-time isolated coaxial cables of constant impedance, the brick forward-going pulses are independent of each other. We observe that the desired equivalent forward-going current driving the pulse must be equal to the sum of the individual brick forward-going currents. We find a set of optimal brick delay times by requiring that the L{sub 2} norm of the difference between the brick-sum current and the desired forward-going current be a minimum. We describe the optimization procedure for the Thor design and show results for various materials of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advantages of the diffuser-augmented wind turbine

Performance optimization for a wind turbine is realized by using a shrouded diffuser to produce up to twice the power of unshrouded turbines of the same diameter. The diffuser converts the kinetic energy of the flow downstream of the rotor into a pressure rise and thus makes it possible for the rotor to capture airflow from a free stream tube area that is greater than that from the rotor itself. The flow velocity through the shrouded rotor is 20 to 60 percent greater than the free wind velocity as opposed to 67 percent less for the unshrouded case. The diffuser also makes it possible to accommodate very high wind speeds without the need of variable pitch in the rotor blades.

Oman, R. A.↗

Proposed Mars Surveyor 2001 Landing Site at 'Ibishead Peninsula', Southern Elysium Planitia

Our objective is to propose a landing site that the Mars Surveyor 2001 Lander and Curie Rover could go to on Mars that should meet the safety requirements of the spacecraft landing system and optimize surface operations (chiefly driven by power and communications requirements). This site lies between 1.5-3.5 deg S latitude, 195-198 deg W longitude, along a sharp albedo contact between the low-viscosity flow units of southern Elysium Planitia and the eroded highlands margin east of Aeolis Mensae. A relatively-bright "peninsula-like" protrusion of the eroded highlands into the south Elysium plains in this area reminds us of the head of an Ibis, and so we nickname this site "Ibishead Peninsula". This site is designed to be situated as close to a diversity of geologic units within view of the lander instruments. Based on our experience with the visibility of horizon details from the Mars Pathfinder and Viking landing sites, we stipulate that for horizon features to be resolved suitably for detailed study from the lander, they must be no more than several kilometers distant. This is so that diversity can be placed in a geologic context in a region that we feel has some exciting science potential. This objective is different from the Mars Pathfinder requirement to land at a site with a maximum chance for containing a diversity of rocks within a few tens of meters of the lander, which resulted in the selection of a "grab bag" site.

Parker, T. J.↗

Pulse Tube Coolers with an Inertance Tube: Theory, Modeling and Practice

We have studied the advantages to be gained by replacing the conventional orifice of a pulse tube cooler by an inertance tube - a long thin tube that introduces the possibility for additional phase shift between pressure and mass flow in the pulse tube section. The case for the use of an inertance tube is most clearly made with an electrical analogy where the 'inductance' added by the inertance tube allows for optimal power transfer at the cold heat exchanger. Detailed modeling of a pulse tube system with an inertance tube confirms these advantages. Comparison between a laboratory cooler with an orifice and with an inertance tube will be presented and reasons wily it is difficult to realize all the expected gain will be given.

Roach, Pat R.↗

Improving Wind Farm Dispatchability Using Model Predictive Control for Optimal Operation of Grid-Scale Energy Storage

This paper demonstrates the use of model-based predictive control for energy storage systems to improve the dispatchability of wind power plants. Large-scale wind penetration increases the variability of power flow on the grid, thus increasing reserve requirements. Large energy storage systems collocated with wind farms can improve dispatchability of the wind plant by storing energy during generation over-the-schedule and sourcing energy during generation under-the-schedule, essentially providing on-site reserves. Model predictive control (MPC) provides a natural framework for this application. By utilizing an accurate energy storage system model, control actions can be planned in the context of system power and state-of-charge limitations. MPC also enables the inclusion of predicted wind farm performance over a near-term horizon that allows control actions to be planned in anticipation of fast changes, such as wind ramps. This paper demonstrates that model-based predictive control can improve system performance compared with a standard non-predictive, non-model-based control approach. It is also demonstrated that secondary objectives, such as reducing the rate of change of the wind plant output (i.e., ramps), can be considered and successfully implemented within the MPC framework. Specifically, it is shown that scheduling error can be reduced by 81%, reserve requirements can be improved by up to 37%, and the number of ramp events can be reduced by 74%.

Halamay, Douglas↗

Numerical studies on the performance of a flow distributor in tank

Flow distributors are generally observed in several nuclear power plants. During core make-up tank (CMT) injection into the reactor, the condensation and thermal stratification are observed in the CMT, and rapid condensation disturbs the injection operation. To reduce the condensation phenomena in the tank, CMT was equipped with a flow distributor. The optimal design of the flow distributor is very important to ensure the structural integrity the CMT and its safe operation during certain transient or accident conditions. In the present study, we numerically investigated the performance of a flow distributor in tank with different shape factors such as the total number of holes, pitch-to-hole diameter ratios, diameter of the hole, and the area ratios. These data will contribute to a design of the flow distributor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Chance-Constrained System of Systems Based Operation of Power Systems

In this paper, a chance-constrained system of systems (SoS) based decision-making approach is presented for stochastic scheduling of power systems encompassing active distribution grids. Based on the concept of SoS, the independent system operator (ISO) and distribution companies (DISCOs) are modeled as self-governing systems. These systems collaborate with each other to run the entire power system in a secure and economic manner. Each self-governing system accounts for its local reserve requirements and line flow constraints with respect to the uncertainties of load and renewable energy resources. A set of chance constraints are formulated to model the interactions between the ISO and DISCOs. The proposed model is solved by using analytical target cascading (ATC) method, a distributed optimization algorithm in which only a limited amount of information is exchanged between collaborative ISO and DISCOs. In this paper, a 6-bus and a modified IEEE 118-bus power systems are studied to show the effectiveness of the proposed algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust online monitoring for calibration assessment of transmitters and instrumentation - 260

Robust online monitoring (OLM) technologies are expected to enable the extension or elimination of periodic sensor calibration intervals in operating and new reactors. Advances in OLM technologies will improve the safety and reliability of current and planned nuclear power systems through improved accuracy and increased reliability of sensors used to monitor key parameters. In this paper, we discuss an overview of research being performed within the Nuclear Energy Enabling Technologies (NEET)/Advanced Sensors and Instrumentation (ASI) program, for the development of OLM algorithms to use sensor outputs and, in combination with other available information, 1) determine whether one or more sensors are out of calibration or failing and 2) replace a failing sensor with reliable, accurate sensor outputs. A Gaussian Process (GP)-based uncertainty quantification (UQ) method previously developed for UQ in OLM, was adapted for this purpose. The resulting models are being evaluated for use in high-confidence signal validation for the purpose of detecting and diagnosing sensor faults, and for computing virtual sensor outputs that may be used as a temporary replacement for failing sensors. In addition to assessing sensor drift, approaches for extracting sensor response time in an automated fashion were developed, for monitoring changes in sensor response time in pressure transmitters. Such changes are also indicative of various fault modes. These algorithms were evaluated with existing measurement data from several laboratory-scale flow loops. Ongoing research in this project is focused on further evaluation of the algorithms, optimization for accuracy and computational efficiency, and integration into a suite of tools for robust OLM that are applicable to monitoring sensor calibration state in nuclear power plants. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Hierarchical VLSM-Based Demand Response Strategy for Coordinative Voltage Control between Transmission and Distribution Systems

This paper presents a two-stage hierarchical voltage-load sensitivity matrix (VLSM)-based demand response (DR) algorithm for regulating the voltage at distribution feeders while fulfilling the transmission system DR requests. This allows distributed energy resources be aggregated to provide transmission-level services without causing operational issues in the distribution grids. At the beginning of each operation interval, a transmission system controller will issue DR commands to distribution system controllers. In the first stage, the distribution system controller uses a VLSM-based dispatch algorithm to dispatch the available DR resources on the distribution feeder with an objective to minimize the total voltage deviations at the lowest cost. Then, power flow studies are conducted assuming that the DR commands have been executed. If voltage violations are detected, a second-stage VLSM-based DR dispatch will be performed to remove those violations. After that, the upper and lower DR limits calculated for the next operation interval are sent back to the transmission system controller so the transmission optimization algorithm can use them as operational constraints to make subsequent decisions. The DR resources include smart photovoltaic (PV) inverters that can curtail real power and provide reactive power support, controllable loads and capacitor banks. In conclusion, the IEEE 123-bus test system with 5-minute PV and load data is used to evaluate the performance of the algorithm. In conclusion, simulation results show that the proposed algorithm can fulfill the transmission-level DR requests while maintaining the voltage in the distribution system within limits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal electric-distribution-grid planning considering the demand-side flexibility of thermal building systems for a test case in Singapore

The planning of district-scale electric grids, i.e., distribution grids, has traditionally relied on finding the most cost-effective design such that they are able to supply the peak loads in a district. With the advent of electric demand side flexibility (DSF), there is the opportunity to reshape peak loads such that the investment cost of the electric grid decreases in exchange for a minor increase in the operation cost. This paper formulates an optimal planning approach for the electric grid at the district scale, which incorporates the DSF from thermal building systems, e.g., heating ventilation and air-conditioning (HVAC) systems. The problem is formulated as a mixed-integer linear program (MILP) and aims at minimizing the investment cost for the grid along with the operation cost of the flexible loads. This is subjected to the fixed electricity demand and thermal comfort constraints of building occupants. To this end, linear models for the thermal comfort in the buildings and the power flow in electric grid are considered. The approach is tested on a district planning test case based in Singapore, where the results show up to 30.9 % reductions in investment cost and up to 3.7 % reduction in total annualized cost. Urban planning authorities, developers and utility companies can all benefit from the presented approach to make optimized investment decisions. For building operators, the results point to the need of adopting their control systems for DSF.

Troitzsch, Sebastian↗

Optimally configuring a measurement system to detect diversions from a nuclear fuel cycle

The civilian nuclear fuel cycle is an industrial process that produces electrical power from the nuclear fission of uranium. Using a measurement system to accurately account for nuclear material, such as uranium, in a fuel cycle is important because of the possible loss or diversion of this potentially dangerous material. A measurement system is defined by a set of measurement methods, or “devices,” used to account for material flows and inventory values at specific locations in the fuel cycle. Here, we develop a simulation-optimization algorithm and an integer-programming model to find the best, or near-best, resource-limited measurement system with a high degree of confidence. The simulation-optimization algorithm minimizes a weighted sum of false positive and false negative diversion-detection probabilities while accounting for material quantities and measurement errors across a finite, discrete time horizon in hypothetical non-diversion and diversion contexts. In each time period, the estimated cumulative material unaccounted for is compared to a fixed or an optimized threshold value to assess if a “significant amount of material” is lost from a measurement system. The integer-programming model minimizes the population variance of the estimated material loss, i.e., material unaccounted for, in a measurement system. We analyze three potential problems in nuclear fuel cycle measurement systems: (i) given location-dependent device precisions, find the configuration of n devices at n locations ( n = 3) that gives the lowest corresponding objective values using the simulation-optimization algorithm and integer-programming model, (ii) find the location at which improving device precision reduces objective values the most using the simulation-optimization algorithm, and determine the effect of measurement frequency on measurement system configurations and objective values using the simulation-optimization algorithm. We obtain comparable results for each problem at least an order of magnitude faster than existing methods do. Using an optimized, rather than fixed, detection threshold in the simulation-optimization algorithm reduces the weighted sum of false positive and false negative probabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic Power Distribution System Management With a Locally Connected Communication Network

Coordinated optimization and control of distribution-level assets can enable a reliable and optimal integration of massive amount of distributed energy resources (DERs) and facilitate distribution system management (DSM). Accordingly, the objective is to coordinate the power injection at the DERs to maintain certain quantities across the network, e.g., voltage magnitude, line flows, or line losses, to be close to a desired profile. By and large, the performance of the DSM algorithms has been challenged by two factors: i) the possibly non-strongly connected communication network over DERs that hinders the coordination; ii) the dynamics of the real system caused by the DERs with heterogeneous capabilities, time-varying operating conditions, and real-time measurement mismatches. In this paper, we investigate the modeling and algorithm design and analysis with the consideration of these two factors. In particular, a game theoretic characterization is first proposed to account for a locally connected communication network over DERs, along with the analysis of the existence and uniqueness of the Nash equilibrium (NE) therein. To achieve the equilibrium in a distributed fashion, a projected-gradient-based asynchronous DSM algorithm is then advocated. The algorithm performance, including the convergence speed and the tracking error, is analytically guaranteed under the dynamic setting. In conclusion, extensive numerical tests on both synthetic and realistic cases corroborate the analytical results derived.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Target Optimization Study: Tolerance Sensitivity

A Work Package was initiated to investigate the potential for target optimization. The current design is made up of 82 disks 0.5 mm thick spaced 0.25 mm apart for helium coolant flow. This disk thickness and gap width are a result of continual increases is beam power and hence volumetric heating rate. Thickening the disks would mean higher disk temperatures, but this would be weighed against the prospect of fewer, thicker disks and wider coolant gap spaces, and the relaxed tolerances that would result. Fabrication of the target holder would be easier and less expensive, and target assembly would also be easier.

43 PARTICLE ACCELERATORS↗