Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

High-performance organic photodetectors enabled by a refined fibrillar multiphase morphology

Film morphology of donor:acceptor blend layers plays a critical role in photon-to-current efficiency and dark/noise current of organic photodetectors (OPDs). One effective approach to manipulate crystallization and mesoscale phase separation of such blend layers is sequential casting (SC). However, the guiding strategies to control the morphology and the impacts on OPD performance of the SC films remain elusive, as the film structural evolution during SC is different from conventional blend casting (BC). In this report a refined fibrillar multiphase morphology is demonstrated by SC in an NT812:IEICO-4F blend film, where the high-quality IEICO-4F crystallites infiltrate the robust NT812 fibril network from the surface to the bulk. Such a morphology leads to improved charge generation and collection, reduced trap states, and enhanced charge block capability of resultant device, enabling simultaneous achievement of high external quantum efficiency and low dark/noise current. A maximum special detectivity of 5 × 10 13 Jones is achieved at 860 nm under –0.1 V, which is among the highest detectivities for vis-to-NIR OPDs. The linear dynamic range and response speed are also improved. Such enhancements are parallelly observed from OPD devices based on other blend systems with similar fibrillar refinement, which provides guidelines for film structure manipulation towards high OPD performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SPE-IMS-MS: An automated platform for sub-sixty second surveillance of endogenous metabolites and xenobiotics in biofluids

Characterization of endogenous metabolites and xenobiotics is essential to deconvoluting the genetic and environmental causes of disease. However, surveillance of chemical exposure and disease-related changes in large cohorts requires an analytical platform that offers rapid measurement, high sensitivity, efficient separation, broad dynamic range, and application to an expansive chemical space. Here in this article, we present a novel platform for small molecule analyses that addresses these requirements by combining solid-phase extraction with ion mobility spectrometry and mass spectrometry (SPE-IMS-MS). This platform is capable of performing both targeted and global measurements of endogenous metabolites and xenobiotics in human biofluids with high reproducibility (CV ≤ 3%), sensitivity (LODs in the pM range in biofluids) and throughput (10-s sample-to-sample duty cycle). We report application of this platform to the analysis of human urine from patients with and without type 1 diabetes, where we observed statistically significant variations in the concentration of disaccharides and previously unreported chemical isomers. Lastly, this SPE-IMS-MS platform overcomes many of the current challenges of large-scale metabolomic and exposomic analyses and offers a viable option for population and patient cohort screening in an effort to gain insights into disease processes and human environmental chemical exposure.

59 BASIC BIOLOGICAL SCIENCES↗

Measuring and predicting sooting tendencies of oxygenates, alkanes, alkenes, cycloalkanes, and aromatics on a unified scale

Databases of sooting indices, based on measuring some aspect of sooting behavior in a standardized combustion environment, are useful in providing information on the comparative sooting tendencies of different fuels or pure compounds. However, newer biofuels have varied chemical structures including both aromatic and oxygenated functional groups, which expands the chemical space of relevant compounds. In this work, we propose a unified sooting tendency database for pure compounds, including both regular and oxygenated hydrocarbons, which is based on combining two disparate databases of yield-based sooting tendency measurements in the literature. Unification of the different databases was made possible by leveraging the greater dynamic range of the color ratio pyrometry soot diagnostic. This unified database contains a substantial number of pure compounds (≥ 400 total) from multiple categories of hydrocarbons important in modern fuels and establishes the sooting tendencies of aromatic and oxygenated hydrocarbons on the same numeric scale for the first time. Then, using this unified sooting tendency database, we have developed a predictive model for sooting behavior applicable to a broad range of hydrocarbons and oxygenated hydrocarbons. The model decomposes each compound into single-carbon fragments and assigns a sooting tendency contribution to each fragment based on regression against the unified database. The model’s predictive accuracy (as demonstrated by leave-one-out cross-validation) is comparable to a previously developed, more detailed predictive model. The fitted model provides insight into the effects of chemical structure on soot formation, and cases where its predictions fail reveal the presence of more complicated kinetic sooting mechanisms. Our work will therefore enable the rational design of low-sooting fuel blends from a wide range of feedstocks and chemical functionalities.

09 BIOMASS FUELS↗

Dielectric-barrier-discharge plasma-assisted hydrogen diffusion flame. Part 1: Temperature, oxygen, and fuel measurements by one-dimensional fs/ps rotational CARS imaging

One-dimensional hybrid fs/ps CARS imaging provides single-laser-shot measurements of temperature, oxygen, and hydrogen in a plasma-assisted hydrogen diffusion flame. The coaxial dielectric-barrier-discharge burner collapses the Re ~50 hydrogen diffusion flame to within ~5 mm of the burner surface at an applied AC potential of 8.75 kV at 18 kHz, coinciding nicely with the full spatial extent of the 1D CARS measurements. Translating the burner through the measurement volume allowed for measurements at numerous radial locations in increments of 1 mm with a resolution of 140 µm × 30 µm × 600 µm, sufficient to resolve spatial gradients in this unsteady flame. Longer probe delays, required for improved dynamic range in regions of high temperature fluctuations, proved difficult to model as a result of a nontrivial decay in the O 2 Raman coherence arising from complexities associated with the triplet ground electronic state of the O 2 molecule. Oxygen linewidths were treated empirically using the observed O 2 coherence decay in spectra acquired from the product gases of lean, near-adiabatic H 2 /air flames stabilized on a Hencken flat-flame burner. While still leading to errors up to 10% at worst, the empirically determined Raman linewidth factors eliminated any systematic error in the O 2 /N 2 measurements with probe delay. Temperature measurements in the Hencken Burner flames proved to be insensitive to probe pulse delay, providing robust thermometry. Here, demonstration of this technique in both the canonical Hencken burner flames and a new DBD burner validates its effectiveness in producing multiple spatially resolved measurements in combustion environments. Measurements in the DBD burner revealed an unsteady, counterflow flattened flame structure near the fuel orifice which became unsteady as the reaction zone curves towards the surface for larger radial positions. Lastly, fluctuations in the fuel concentration were largest at the source, as the large, plasma-generated, unsteady external toroidal vortex that dominates the transport in this flame provides enhanced ventilation of the flame surface in close proximity to the fuel tube.

42 ENGINEERING↗

Flow pattern changes influenced by variation of viscosities of a heterogeneous gas-liquid mixture flow in a vertical channel

In the steady-state flow of a heterogeneous mixture such as an air-liquid mixture, the velocity and void fraction are space- and time-dependent parameters. These parameters are the most fundamental in the analysis and description of a multiphase flow. The determination of flow patterns in an objective way is extremely critical, since this is directly related to sudden changes in spatial and temporal changes of the random like characteristic of concentration. Flow patterns can be described by concentration signals in time, amplitude, and frequency domains. Despite the vital importance and countless attempts to solve or incorporate the flow pattern phenomena into multiphase models, it has still been a very challenging topic in the scientific community since the 1940's and has not yet reached a satisfactory solution. This paper reports the experimental results of the impact of fluid viscosity on flow patterns for two-phase flow. Two-phase flow was created in laboratory equipment using air and liquid as phase medium. The liquid properties were changed by using variable concentrations of glycerol in water mixture which generated a wide-range of dynamic viscosities ranging from 1 to 1060 MPa s. The in situ spatial concentration vs. liquid viscosity and airflow velocity of two-phase flow in a vertical ID=50.8 mm pipe were measured using two concomitant computer-aided measurement systems. After acquiring data, the in situ special concentration signals were analyzed in time (spatial concentration and RMS of spatial concentration vs. time), amplitude (PDF and CPDF), and frequency (PSD and CPSD) domains that documented broad flow pattern changes caused by the fluid viscosity and air velocity changes. (author)

42 ENGINEERING↗

Application of modern autoradiography to nuclear forensic analysis

Modern autoradiography techniques based on phosphorimaging technology using image plates (IPs) and digital scanning can identify heterogeneities in activity distributions and reveal material properties, serving to inform subsequent analyses. Here, we have adopted these advantages for applications in nuclear forensics, the technical analysis of radioactive or nuclear materials found outside of legal control to provide data related to provenance, production history, and trafficking route for the materials. IP autoradiography is a relatively simple, non-destructive method for sample characterization that records an image reflecting the relative intensity of alpha and beta emissions from a two-dimensional surface. Such data are complementary to information gathered from radiochemical characterization via bulk counting techniques, and can guide the application of other spatially resolved techniques such as scanning electron microscopy (SEM) and secondary ion mass spectrometry (SIMS). IP autoradiography can image large 2-dimenstional areas (up to 20 × 40 cm), with relatively low detection limits for actinides and other radioactive nuclides, and sensitivity to a wide dynamic range (10 5 ) of activity density in a single image. Distributions of radioactivity in nuclear materials can be generated with a spatial resolution of approximately 50 μm using IP autoradiography and digital scanning. While the finest grain silver halide films still provide the best possible resolution (down to ~10 μm), IP autoradiography has distinct practical advantages such as shorter exposure times, no chemical post-processing, reusability, rapid plate scanning, and automated image digitization. Sample preparation requirements are minimal, and the analytical method does not consume or alter the sample. These advantages make IP autoradiography ideal for routine screening of nuclear materials, and for the identification of areas of interest for subsequent micro-characterization methods. Here in this article we present a summary of our setup, as modified for nuclear forensic sample analysis and related research, and provide examples of data from select samples from the nuclear fuel cycle and historical nuclear test debris.

07 ISOTOPE AND RADIATION SOURCES↗

Development of intelligent control module for the J-TEXT electron cyclotron emission imaging system

An Electron Cyclotron Emission Imaging (ECEI) system has been developed on the J-TEXT tokamak and employed for the multi-dimensional electron temperature fluctuation imaging measurement in 2019 campaign. The intelligent control module has been developed and been used to flexibly setup the 256-channel ECEI system configurations for different plasma scenarios. The adjustments of key parameters are merged in this module including size and position of the geometric observation window, and the dynamic range of the signal and image resolution. The user-friendly interface is also developed for the tokamak operator to set the ECEI system focusing on physics interested region. Furthermore, this module is installed close to the diagnostic system around the J-TEXT tokamak, which can be remotely controlled by authorized operators in the control room. It significantly improves ECEI flexibility and stability, and also keeps the operation technician away from the harsh radiation environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FT-ICR MS optimization for the analysis of intact proteins

Fourier-transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) remains the technique of choice for the analysis of intact proteins from complex biological systems, i.e. top-down proteomics. Recently, we have implemented a compensated open cylindrical ion trapping cell into a 12 T FT-ICR mass spectrometer. This new cell has previously demonstrated improved sensitivity, dynamic range, and mass measurement accuracy for the analysis of relatively small tryptic peptides. These improvements are due to the improved trapping potential of the cell which is significantly closer to the ideal harmonic trapping potential. Here we report the instrument optimization for the analysis of large macro-molecular ions, such as proteins. Also, presented are first principle theoretical considerations to account for different optimum conditions for the analysis of large macro-molecules. The proposed high energy ion loss mechanism is further supported by experimental results of bovine ubiquitin and serum albumin. We find that the analysis of large macro-molecules can be significantly improved by the further reduction of pressure in the ion trapping cell. This will reduce the impact of the high energy ion loss mechanism and enable increased sensitivity and mass measurement accuracy to be realized without compromising resolution. Further, these results appear to be applicable to FTMS in general, and the high energy ion loss mechanism applies to Orbitrap mass analyzers as well.

59 BASIC BIOLOGICAL SCIENCES↗

A Conceptual Approach for FT-ICR cell Harmonization Utilizing External Shim Electrodes

A key component of FT-ICR mass spectrometers is the trapped ion cell, where analyte ions are confined for excitation and detection. Recent advances in superconducting magnet technology make possible the construction of magnets with higher magnetic fields and regions of improved homogeneity, setting the stage for major advances in FT-ICR performance metrics. In particular, fitting next generation superconducting magnets with ICR cells incorporating harmonic trapping electric fields, suitably configured with electrodes for manipulating and detecting ions, will simultaneously improve resolving power, mass measurement accuracy, dynamic range and sensitivity of FT-ICR MS. Here, a focused conceptual approach for achieving cell harmonization is presented, using as a metric, the spatial uniformity of the radial electric field divided by radius. This new concept for cell harmonization utilizing external shims and two proof-of-principle examples for externally shimmed cell configurations developed using 3D potential calculations are described. These designs are based on a series of external electrodes that serve to generate the trapping potential and are electrically de-coupled from the detection and excitation electrodes. A nearly ideal 3D quadrupolar potential is achieved throughout the cell volume while simplifying electrical and mechanical connections for FT-ICR cells.

Environmental Molecular Sciences Laboratory↗

Development and characterization of an aerosol-generated multi-method analytical particle test material

Ceria (CeO 2 ) particles with low to ultra-low loading of nickel dopant were produced using an aerosol-based, droplet-to-particle synthesis via an in-line calcination technique. This aerosol-based synthesis method enables the production of particles with a monodisperse size distribution. These produced and well-characterized, multi-element, ceria-based particles demonstrate a material exemplar for multi-method analytical testing. They were prepared from a cerium nitrate feedstock where low loading nickel dopant was added at target Ni/(Ni + Ce) atomic percents of 1 %, 0.1 %, and 0.01 %, using a nickel nitrate spike. This methodology proved to produce ceria particles doped with a dynamic range of low to ultra-low loadings of nickel over a 24-h period, with consistent size distribution, morphology, and composition. The successful incorporation of nickel was demonstrated with bulk and single particle inductively coupled plasma mass spectroscopy and revealed notable particle-to-particle elemental homogeneity. X-ray photoelectron spectroscopy demonstrated the presence of a high concentration of nickel dopant incorporated preferentially toward the surface of the particles, and that this dopant aided oxidation of surface Ce(III) atoms to Ce(IV). These particle test materials were then validated through X-ray absorption near edge spectroscopy, comparing the ultra-low 0.01 % Ni and low 1 % Ni-doped ceria samples. This revealed a more-reduced oxidation state of the nickel with an increase in dopant concentration. Finally, this work demonstrates a synthesis and systematic characterization scheme to produce multi-method analytical test particulates.

36 MATERIALS SCIENCE↗

A method to improve the sensitivity of neutron porosity measurement based on D-T source

Compensated porosity logging tool utilizing deuterium-tritium (D-T) source shows a lower sensitivity to the variation of formation porosity compared with that adopting Am-Be source. In order to improve the sensitivity, the factors of an infinite homogeneous formation influencing slowing-down length and the near to far counts ratio are analyzed in this paper. Then Monte Carlo simulation method is used to build well logging models to study the responses of a neutron porosity logging tool to hydrogen index and formation density. It shows that in addition to hydrogen index, the variation of the density also has a great impact on slowing-down length and the ratio which reduces the response sensitivity to porosity. A new model depicts the relationship between the count ratio and porosity is proposed. Finally, when the model is used to process the measured ratio, the ratio shows improved dynamic range and sensitivity to porosity compared with the values without processing.

47 OTHER INSTRUMENTATION↗

Observations of Ag diffusion in ion implanted SiC

The nature and magnitude of Ag diffusion in SiC has been a topic of interest in connection with the performance of tristructural isotropic (TRISO) coated particle fuel for high temperature gas-cooled nuclear reactors. Ion implantation diffusion couples have been revisited to continue developing a more complete understanding of Ag fission product diffusion in SiC. Ion implantation diffusion couples fabricated from single crystal 4H-SiC and polycrystalline 3C-SiC substrates and exposed to 1500–1625°C, were investigated in this study by transmission electron microscopy and secondary ion mass spectrometry (SIMS). The high dynamic range of SIMS allowed for multiple diffusion régimes to be investigated, including enhanced diffusion by implantation-induced defects and grain boundary (GB) diffusion in undamaged SiC. Lastly, estimated diffusion coefficients suggest GB diffusion in bulk SiC does not properly describe the release observed from TRISO fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthesis of Sb{sub 2}S{sub 3} nanowall arrays for high performance visible light photodetectors

Highlights: • Sb{sub 2}S{sub 3} nanowall arrays have been synthesized via a facile polyol refluxing process. • We fabricated Sb{sub 2}S{sub 3} rigid and flexible photodetectors successfully. • The photoelectric properties were studied upon visible light irradiation. • The rigid photodetector exhibit excellent photoconductive performance. - Abstract: By using a facile polyol and template-free refluxing process, we report the successful synthesis of Sb{sub 2}S{sub 3} nanowall arrays (NWAs) on the surface of FTO substrate. The as-synthesized samples were characterized by SEM, TEM, XRD and UV–vis DRS. The NWAs-based photodetector exhibits linear photocurrent characteristics, high stability, excellent reproducible properties, low LDR (linear dynamic range) value of 8.6 dB, fast response time of 0.52 s and recovery time of 1.11 s. The flexible photodetector was also fabricated by simply transferring the NWAs to a transparent PET substrate; it revealed good flexibility and stability. Our results imply that Sb{sub 2}S{sub 3} NWAs are prospective candidates for high-performance nanoscale optoelectronic devices.

36 MATERIALS SCIENCE↗

Electrochromic mirror using viologen-anchored nanoparticles

Highlights: • Three types of ECM device were fabricated using viologen-anchored ECDs. • The devices were investigated according to their optical structures. • The anti-reflection material affects the reflectance and the coloration efficiency. • The device design of ECMs is a crucial factor for clear reflected images. - Abstract: Electrochromic mirrors (ECMs) that are used in automobile mirrors need to have high reflectance, a high contrast ratio, and a clear image. In particular, it is critical that distortions of clear images are minimized for safety. Therefore, an ECM is fabricated using viologen-anchored nanoparticles and a magnesium fluoride (MgF{sub 2}) layer with an anti-reflection function. The ECM has approximately 30.42% in the reflectance dynamic range and 125 cm{sup 2}/C high coloration efficiency.

36 MATERIALS SCIENCE↗

Scintillation, dosimeter and optical properties of MgF2 transparent ceramics doped with Gd3+

Highlights: • We have developed MgF{sub 2}:Gd{sup 3+} transparent ceramics by SPS. • The samples showed luminescence due to the 4f-4f transitions of Gd{sup 3+}. • The 1% Gd-doped sample has high TSL sensitivity equivalent to commercial personal dosimeters. - Abstract: In this study, we have developed MgF{sub 2}:Gd transparent ceramics by spark plasma sintering (SPS) and evaluated the scintillation, dosimeter and optical properties. All the sample were successfully synthesized in a transparent form with relative densities over 99% to that of the single crystal. The samples were confirmed to show scintillation, thermally-stimulated luminescence (TSL) and optically-stimulated luminescence (OSL). The origin of these emissions was due to the 4f-4f transitions of Gd{sup 3+} appearing as a single peak at 310 nm. In particular, the TSL was very sensitive to X-rays, and especially the 1% Gd-doped sample showed a sensitivity as low as 0.1 mGy. The TSL response increases monotonically with the irradiation dose, and the dynamic range was confirmed to be over 0.1–1000 mGy, which was equivalent sensitivity to that of commercial personal dosimeters.

61 RADIATION PROTECTION AND DOSIMETRY↗

Large-scale synthesis of Bi2S3 nanorods and nanoflowers for flexible near-infrared laser detectors and visible light photodetectors

Highlights: • Bi{sub 2}S{sub 3} nanorods and nanoflowers flexible laser detectors have been fabricated successfully. • The photoelectric properties were studied upon 808 nm and 980 nm laser beam irradiation. • Bi{sub 2}S{sub 3} nanorods flexible photodetector exhibits higher LDR value than other Bi{sub 2}S{sub 3} based photodetectors. - Abstract: Rod-like and flower-like bismuth sulphide semiconductor nanomaterials were large-scale synthesized and applied for flexible near-infrared laser detectors and visible light photodetectors. The nanorod-based flexible laser detectors have high photoresponse characteristics to 808 nm and 980 nm laser light, and their switching ratio were calculated to be 9.2 and 23.6 times, respectively. The flexible laser detectors exhibit good linear current characteristics, photo-sensitivity dependence of light intensity. Especially, the flexible nanorod-based photodetector has high LDR (linear dynamic range) value of 19.60 dB. Furthermore, the Bi{sub 2}S{sub 3} nanorods based visible light photodetector exhibits higher LDR value than other Bi{sub 2}S{sub 3} based photodetectors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

CALIFA, a Dedicated Calorimeter for the R{sup 3}B/FAIR

The R{sup 3}B experiment (Reactions with Relativistic Radioactive Beams) at FAIR (Facility for Antiproton and Ion Research) is a versatile setup dedicated to the study of reactions induced by high-energy radioactive beams. It will provide kinematically complete measurements with high efficiency, acceptance and resolution, making possible a broad physics program with rare-isotopes. CALIFA (CALorimeter for In-Flight detection of gamma-rays and high energy charged pArticles), is a complex detector based on scintillation crystals, that will surround the target of the R{sup 3}B experiment. CALIFA will act as a total absorption gamma-calorimeter and spectrometer, as well as identifier of charged particles from target residues. This versatility is its most challenging requirement, demanding a huge dynamic range, to cover from low energy gamma-rays up to 300 MeV protons. This fact, along with the high-energy of the beams determine the conceptual design of the detector, presented in this paper, together with the technical solutions proposed for its construction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hierarchical Trigger of the ALICE Calorimeters

The trigger of the ALICE electromagnetic calorimeters is implemented in 2 hierarchically connected layers of electronics. In the lower layer, level-0 algorithms search shower energy above threshold in locally confined Trigger Region Units (TRU). The top layer is implemented as a single, global trigger unit that receives the trigger data from all TRUs as input to the level-1 algorithm. This architecture was first developed for the PHOS high p{sub T} photon trigger before it was adopted by EMCal also for the jet trigger. TRU units digitize up to 112 analogue input signals from the Front End Electronics (FEE) and concentrate their digital stream in a single FPGA. A charge and time summing algorithm is combined with a peakfinder that suppresses spurious noise and is precise to single LHC bunches. With a peak-to-peak noise level of 150 MeV the linear dynamic range above threshold spans from MIP energies at 215 up to 50 GeV. Local level-0 decisions take less than 600 ns after LHC collisions, upon which all TRUs transfer their level-0 trigger data to the upstream global trigger module which searches within the remaining level-1 latency for high p{sub T} gamma showers (PHOS) and/or for Jet cone areas (EMCaL).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗