Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Effect of Fuel Reactivity and End-Gas Temperature on Autoignition and Flame Propagation Rate in Primary Reference Fuel Mixtures at Elevated Temperature and Pressure

Knock in spark-ignited (SI) engines is initiated by autoignition in the unburned gases upstream of spark-ignited, propagating, turbulent premixed flames. In this study, knock propensity of SI fuels was quantified via observations of end-gas autoignition (EGAI) in unburned gases upstream of laser-ignited, premixed flames at elevated pressures and temperatures in a rapid compression machine. Stoichiometric primary reference fuel (n-heptane/isooctane) blends of varying reactivity were ignited using an Nd:YAG laser over a range of compressed temperatures and pressures, all in excess of 691 K and 18.8 bar. High-speed pressure measurements and schlieren images indicated the presence of EGAI in the unburned gases upstream of spherical, outwardly propagating flames. The fraction of the total heat release attributed to EGAI was found to vary with fuel reactivity and the time-integrated temperature of the end-gas prior to ignition. Flame propagation rates, measured using schlieren imaging, did not vary strongly with fuel reactivity but were affected by turbulence caused by variation in piston timing. Under conditions of low turbulence, measured flame propagation rates agreed with one-dimensional premixed laminar flame speed computations performed at the same conditions.

End-Gas Autoignition, Engine Knock, Rapid Compress↗

Ultrasonic Testing (UT) and Computed Tomography (CT) Comparative Scanning of Proposed Additive Manufacturing Reference Standard

This report presents qualitative results of ultrasonic full matrix capture/total focusing method (FMC/TFM) scanning of two series of blocks, additively manufactured by powder bed fusion, containing a variety of internal features and structures that would not be achievable by conventional manufacturing techniques. The purpose of the first series of additively manufactured (AM) blocks was to explore the possibility of building calibration blocks for FMC/TFM ultrasonic testing (UT). It was confirmed that AM is a suitable candidate for generation of unusual and novel reflector forms, such as rotating slots, purposely embedded voids, and tapering holes, and that FMC/TFM was very capable of characterizing them. The intended use of the second series of AM blocks was as UT reference blocks to characterize the AM process quality or the interrogating UT technique. The larger block in this series was scanned from multiple faces, using multiple UT methods (conventional UT and FMC/TFM) and X-ray computed tomography for comparative purposes. The performance of each method was quantified by a metric corresponding to the detection limit of each feature, and the quantitative results are discussed.

36 MATERIALS SCIENCE↗

Photovoltaic (PV) Quick Reference Guide

This Photovoltaic (PV) and Energy Storage System (EES) Quick Reference Guide is for inspectors inspecting projects permitted with SolarAPP+.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Reference electrode and electrochemical monitoring system

A reference electrode includes a metal body, a lead disposed within the metal body, an insulator disposed between the lead and the metal body, the insulator including a ceramic material, and a porous metal chamber coupled to the metal body, the lead extending into the porous metal chamber. The porous metal chamber is configured to maintain an electrolyte solution within the porous metal chamber to establish a redox couple with the lead.

Burak, Adam↗

Method for simultaneous characterization and expansion of reference libraries for small molecule identification

A variational autoencoder (VAE) has been developed to learn a continuous numerical, or latent, representation of molecular structure to expand reference libraries for small molecule identification. The VAE has been extended to include a chemical property decoder, trained as a multitask network, to shape the latent representation such that it assembles according to desired chemical properties. The approach is unique in its application to metabolomics and small molecule identification, focused on properties that are obtained from experimental measurements (m/z, CCS) paired with its training paradigm, which involves a cascade of transfer learning iterations. First, molecular representation is learned from a large dataset of structures with m/z labels. Next, in silico property values are used to continue training. Finally, the network is further refined by being trained with the experimental data. The trained network is used to predict chemical properties directly from structure and generate candidate structures with desired chemical properties. The network is extensible to other training data and molecular representations, and for use with other analytical platforms, for both chemical property and feature prediction as well as molecular structure generation.

Colby, Sean M.↗

A Non-Destructive Investigation of Plutonium Reference Items Used for Calibration

The calibration of Non-Destructive Assay (NDA) equipment relies on the availability of certified items of known content and construction. Increasing use is being made of calculational tools to create calibration data and so representative standards are no longer always needed. However, even with this approach it is invaluable to benchmark the tools against the measured response under well known conditions and to apply the Measured: Calculated ratio as a scaling factor. Reference sources for Pu are typically doubly encapsulated for safety reasons and contain Pu of well known chemical form, elemental composition, relative isotopic composition and mass. Destructive analysis techniques are used to characterize the materials and so these attributes are usually known with far greater accuracy than that achievable by the NDA methods to which they are being applied. Construction details are also usually provided in order to permit attenuation and related factors to be estimated. This work concerns the empirical investigation of a set of encapsulated PuO{sub 2} powder standards. The characterization and fabrication of the items is adequately documented with the exception of fill height. The fill height governs the powder density and in turn both the self attenuation of photons and the self multiplication of neutrons, consequently this is an important omission. Initially the location and dimensions of the internal plunger cup was used as a basis to estimate the packing density, but later records of plunger positions made at the time of filling were found and significant revisions followed. As a consequence of discrepancies observed in measurements designed to evaluate a new lump correction algorithm we were led to investigate the powder density and distribution directly by gamma-ray scanning. In some cases this resulted in revised density estimates. Equally importantly it was discovered that for the smallest mass items, the powder was not held fixed in the form of a uniform disc by the spring loaded plunger but rather could flow inside the inner capsule. In this paper we describe the nature of the investigation, report the salient findings and explain the implications for modeling the sources for the calibration of NDA equipment. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Towards a reference numerical scheme using MCNPX for PWR control rod tip fluence estimations

Recent occurrences of cracks and fissures on the cladding tubes of PWR control rod (CR) fingers employed in the Swiss reactors prompted the need to develop more reliable analytical methods for CR tip fluence estimations. To partly address this need, a deterministic methodology based on SIMULATE-3/CASMO-4 was in recent years developed at PSI. Although this methodology has already been applied for independent support to licensing issues related to CR lifetime, two main questions are currently being the center of attention for further enhancements. First, the methodology relies on several assumptions that have so far not been verified. Secondly, an assessment of the achieved accuracy has not been addressed. In an attempt to answer both these open questions, it was considered appropriate to develop an alternative computational scheme based on the stochastic MCNPX code with the objective to provide reference numerical solutions. This paper presents the first steps undertaken in that direction. To start, a methodology for a volumetric neutron source transfer to full core MCNPX models with detailed CR as well as axial reflector representations is established. On this basis, the assumptions of the deterministic methodology are studied for selected CR configurations for two Beginning-of-Life cores by comparing the spatial neutron flux distributions obtained with the two approaches for the entire spectrum. Finally, for the high-energy range (E> 1 MeV) and for a few CRs, the new MCNPX scheme is applied to estimate the accumulated fluence over one real operated cycle and the results are compared with the deterministic approach. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

DOMINO: A fast 3D cartesian discrete ordinates solver for reference PWR simulations and SPN validation

As part of its activity, EDF R and D is developing a new nuclear core simulation code named COCAGNE. This code relies on DIABOLO, a Simplified PN (SPN) method to compute the neutron flux inside the core for eigenvalue calculations. In order to assess the accuracy of SPN calculations, we have developed DOMINO, a new 3D Cartesian SN solver. The parallel implementation of DOMINO is very efficient and allows to complete an eigenvalue calculation involving around 300 x 10{sup 9} degrees of freedom within a few hours on a single shared-memory supercomputing node. This computation corresponds to a 26-group S{sub 8} 3D PWR core model used to assess the SPN accuracy. At the pin level, the maximal error for the SP{sub 5} DIABOLO fission production rate is lower than 0.2% compared to the S{sub 8} DOMINO reference for this 3D PWR core model. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Combined Effort to De-Inventory the New Brunswick Laboratory of Plutonium Certified Reference Materials - 20504

To de-inventory plutonium Certified Reference Materials standards (CRMs) from the New Brunswick National Laboratory (NBL), the Argonne National Laboratory (ANL) and Savannah River National Laboratory (SRNL) formed a unique team. This teaming arrangement leveraged the different capabilities and expertise of both laboratories, helping to ensure the effort would be performed both safely and cost-effectively. With the NBL then physically housed on the ANL site, ANL served as the host-site, providing the necessary facilities and support services (e.g., supplying everything from hoods, loading equipment, and scales to Health Physics supports). From a packaging perspective, ANL's responsibilities focused mainly on characterizing and preparing the contents for shipment, followed by performing the Shipper of Record activities. With SRNL being the Package Design Authority of the 9978, the Type B packaging used for this effort, SRNL's scope included developing a Safety Analysis Report in Packaging (SARP) Letter Amendment to add the CRMs as authorized contents to the 9978. Recognizing competency, ANL prodigiously tasked SRNL to perform the actual loading of the CRMs into the 9978s, while physically on the ANL site. This paper details five different aspects of this effort. They are: 1. Characterization/validation of the CRM contents. 2. Development of the 9978 SARP Letter Amendment for the content change. 3. Development of the nitrogen inerting method to address SARP identified potential flammability concerns. 4. Renewal of the SRNL 9978 loading procedure. 5. Performance of the actual work execution activities. In 2017, the first nine packages were successfully loaded and shipped from NBL, while in 2019, the last ten were successfully loaded and planned for shipment. Without ANL leveraging SRNL's strengths, the de-inventorying of NBL of its plutonium CRMs would have likely taken many years longer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Implementation and Validation of Reference Sensitivity Profile Calculations in TRIPOLI 4 - 14247

In current neutron transport calculations, particularly on continuous-energy Monte-Carlo codes, the major source of uncertainty is coming from nuclear data. In order to improve nuclear data evaluations, integral experiments are used. Feedback is then precisely obtained by re-estimating cross-section levels and correlations according to their sensitivity. k{sub eff}-sensitivity coefficients are traditionally obtained using deterministic codes since hands-on methods were not yet implemented in continuous energy Monte Carlo codes. In this paper, an Iterated-Fission-Probability-based method newly developed in the continuous energy Monte Carlo code TRIPOLI-4 will be used to calculate sensitivity coefficient breakdown on isotopes and reactions and results will be compared to those of ERANOS deterministic code. Objective is twofold: to show the reliability of the new TRIPOLI-4 method and to identify where and why profiles are slightly different. Sensitivity profiles, forward and adjoint fluxes are thus meticulously compared using a fine 1968-group energy structure. An OECD international benchmark (Uncertainty Analysis for Criticality Safety Assessment - UACSA - Phase III) is taken as working example to enforce validation and to compare to independent results (e.g. MCNP-6). This benchmark is constituted of two bare spheres filled with homogeneous mixture of uranium and polyethylene (respectively 2% and 50% U-235 enrichments) and gives an overview of issues encountered in thermal reactor cores. Several energy-group structures (1968G, 172G, 33G) are also tested in ERANOS to identify multi-group and implicit effects. Lessons learnt are that continuous Monte Carlo methods seem to be mature and compare well with deterministic codes. Only damper the U-238 elastic - and on certain conditions the U-238 capture - sensitivity coefficient for which difference can reach 30% between TRIPOLI-4 and ERANOS. Indeed concerning U-238, implicit effects are emphasized and multi-group theory remains limited by hypothesis; even a 1968-group structure is not refined enough to properly calculate U-238 elastic scattering k{sub eff}-sensitivity. This reference 3D continuous-energy sensitivity capability in TRIPOLI4-IFP will be extensively used in the uncertainty automated tool RIB of the French Criticality-Safety package CRISTAL. (authors)

42 ENGINEERING↗

Improved Transient Stability Analysis of Multi-loop Droop-Controlled Grid Forming Inverters with Current Reference Limiter

Grid-forming control is regarded as a promising technology for achieving high levels of renewable energy integration in future power grids. To fulfill this role, grid-forming devices is expected to possess fault ride through capability. This paper focuses on the transient stability of a droop control-based grid-forming inverter that utilizes current reference saturation as a current limiting strategy. The objective of this work is to investigate the fault recovery process of the grid-forming inverter and analyze the criterion for transitioning the inverter out of the current limiting mode. The theoretical analysis in this study is validated through time-domain simulations, which compare the results obtained using the circuit current limiting method and the d-axis priority-based current limiting method. Various operational conditions are considered to comprehensively evaluate the performance of the grid-forming inverter during a three-phase short circuit scenario. The simulation results confirm the effectiveness of the proposed theoretical approach.

Lyu, Xue↗

Solvent independent reference electrodes for use with non-aqueous electrolytes

The present disclosure relates to a method for forming a reference electrode for use in electrochemical testing applications. The method may involve positioning a porous frit against one end of a hollow tube, and securing the frit and the hollow tube to one another to form an assembly. The method may further involve forming a silver sulfide coating on a silver wire to produce a silver sulfide coated silver wire. The method may further involve filling the hollow tube with a non-aqueous solution, and inserting at least a portion of the silver sulfide coated silver wire into the non-aqueous solution in the hollow tube.

Horwood, Corie↗

PID-Regulated Heating System for PIP-II Reference Line

The Proton Improvement Project-2 centers on building a new superconducting linear particle accelerator (Linac) at Fermilab. At the heart of the accelerator is the reference line, a critical system that defines the ideal path for the particle beam as it passes through magnets, RF cavities, and other beamline elements. Temperature stability is crucial for the reliable operation of RF components, such as mixers and filters. Fluctuations affect key performance parameters like conversion loss, isolation, and linearity. To mitigate any drift caused by ambient temperature changes, a heating plate assembly is utilized to maintain key components at a controlled temperature of 40°C. The system utilizes an aluminum 36”x36”x0.5” heat plate powered by a MOSFET-based control circuit, delivering approximately 460 W of thermal energy through a resistor array. Real-time temperature feedback is provided by a PT100 Resistance Temperature Detector (RTD), which interfaces with a Proportional–Integral–Derivative (PID) control algorithm to maintain closed-loop temperature regulation. The control signal actively modulates the gate voltage of an N channel MOSFET, dynamically adjusting power delivery in response to deviations from the temperature setpoint. Simulations and LTspice models validate the functionality and responsiveness of the circuit under varying conditions. The prototype has successfully demonstrated stable thermal control, paving the way for integration into the PIP-II infrastructure. The final design will feature an expanded resistor array, as well as communication with a PLC for continuous data acquisition and diagnostics. This work directly supports Fermilab’s broader mission by contributing to the stability and reliability of core accelerator systems, enhancing the precision of particle beam delivery for future physics experiments.

Mosher, Alexander [Fermilab]↗

A Sub-electron-noise Skipper-CCD Readout ASIC with Improved Channel-to-channel Isolation and an Integrated Cryogenic Voltage Reference

The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope integrators. They are capable of working from room to cryogenic temperatures, down to 84 K. The present iteration of the ASIC has been fabricated including several design updates and the addition of an on-chip voltage reference, resulting in improved performance. This work presents the main vulnerabilities solved, the changes carried out, and the resulting performance benefits. Measurements with a skipper-CCD and the ASIC at 140 K showed that the single-electron resolution can be reached by averaging the measured charge in the analog domain using the analog pile-up technique with a readout noise as low as 0.11 erms of equivalent charge for 1200 samples. The channel-to-channel crosstalk was also characterized showing values better than -62 dB.

Alcalde Bessia, Fabricio↗

A Sub-electron-noise Skipper-CCD Readout ASIC with Improved Channel-to-channel Isolation and an Integrated Cryogenic Voltage Reference

The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope integrators. They are capable of working from room to cryogenic temperatures, down to 84 K. The present iteration of the ASIC has been fabricated including several design updates and the addition of an on-chip voltage reference, resulting in improved performance. This work presents the main vulnerabilities solved, the changes carried out, and the resulting performance benefits. Measurements with a skipper-CCD and the ASIC at 140 K showed that the single-electron resolution can be reached by averaging the measured charge in the analog domain using the analog pile-up technique with a readout noise as low as 0.11 erms of equivalent charge for 1200 samples. The channel-to-channel crosstalk was also characterized showing values better than -62 dB.

Alcalde Bessia, Fabricio↗

STANDARD REFERENCE MATERIAL CHARPY TESTING FROM HIGH FLUENCE SURVEILLANCE CAPSULE

The Palisades Nuclear Generating Station included in its original surveillance program a surveillance capsule, designated A-60. The capsule was removed from its surveillance position in early 1995 and has been resident in the spent fuel pool since that time. It was harvested to perform characterization of surveillance specimens in this capsule in 2023. This capsule was irradiated to a fluence of 1.96x1020 n/cm2 (E> 1MeV) that is equivalent for more than 150 effective full power years for the current US reactor pressure vessel (RPV) fleet. This capsule contained several materials, including Charpy specimens of standard reference material (SRM) from Heavy-Section Steel Technology (HSST) A533-B Plate 01. To perform Charpy testing of this highly irradiated material, the new Charpy specimen transfer system was designed and implemented on Charpy impact testing machine in the hot cell to accommodate remote testing of these specimens. This new transfer system includes integrated environmental chamber to cool or heat Charpy specimens to the desired temperature. Testing of this highly irradiated material revealed very large shift of Charpy transition temperature, 188oC.

Sokolov, Mikhail [ORNL] (ORCID:0000000256373346)↗

ILC Reference Design And Challenges

The International Linear Collider (ILC) is a 500 GeV center-of-mass electron-positron linear collider based on 1.3 GHz superconducting rf. For the past two years, the ILC design has been developed by an international collaboration, the Global Design Effort. A draft Reference Design Report (RDR) for the ILC was released in February 2007 and, after international review, the final draft will be published in mid-July, 2007. This talk will describe the ILC design along with the outstanding R&D and engineering challenges. The next step is to complete an Engineering Design (EDR) by 2010, and plans for this phase will also be discussed.

43 PARTICLE ACCELERATORS↗

Reference reactor module for NASA's lunar surface fission power system

Surface fission power systems on the Moon and Mars may provide the first US application of fission reactor technology in space since 1965. The Affordable Fission Surface Power System (AFSPS) study was completed by NASA/DOE to determine the cost of a modest performance, low-technical risk surface power system. The AFSPS concept is now being further developed within the Fission Surface Power (FSP) Project, which is a near-term technology program to demonstrate system-level TRL-6 by 2013. This paper describes the reference FSP reactor module concept, which is designed to provide a net power of 40 kWe for 8 years on the lunar surface; note, the system has been designed with technologies that are fully compatible with a Martian surface application. The reactor concept uses stainless-steel based. UO{sub 2}-fueled, pumped-NaK fission reactor coupled to free-piston Stirling converters. The reactor shielding approach utilizes both in-situ and launched shielding to keep the dose to astronauts much lower than the natural background radiation on the lunar surface. The ultimate goal of this work is to provide a 'workhorse' power system that NASA can utilize in near-term and future Lunar and Martian mission architectures, with the eventual capability to evolve to very high power, low mass systems, for either surface, deep space, and/or orbital missions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗