Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

High-resolution x-ray radiography with Fresnel zone plates on the University of Rochester’s OMEGA Laser Systems

Experiments performed at the Laboratory for Laser Energetics with a continuous-wave (cw) x-ray source and on the OMEGA and OMEGA EP Laser Systems have utilized a Fresnel zone plate (FZP) to obtain x-ray images with a spatial resolution as small as ~1.5 μm. Such FZP images were obtained with a charge-coupled device or a framing camera at energies ranging from 4.5 keV to 6.7 keV using x-ray line emission from both the cw source and high-intensity, laser-beam–illuminated metal foils. In all cases, the resolution test results are determined from patterns and grids backlit by these sources. Here, the resolutions obtained are shown to be due to a combination of the spectral content of the x-ray sources and detector resolution limited by the magnification of the images (14× to 22×). High-speed framing cameras were used to obtain FZP images with frame times as short as ~30 ps. Double-shell implosions on OMEGA were backlit by laser-irradiated Fe foils, thus obtaining a framing-camera–limited, FZP-image resolution of ~3 μm–4 μm.

47 OTHER INSTRUMENTATION↗

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

AUTOMATED DETERMINATION OF [Fe/H] AND [C/Fe] FROM LOW-RESOLUTION SPECTROSCOPY

We develop an automated spectral synthesis technique for the estimation of metallicities ([Fe/H]) and carbon abundances ([C/Fe]) for metal-poor stars, including carbon-enhanced metal-poor stars, for which other methods may prove insufficient. This technique, autoMOOG, is designed to operate on relatively strong features visible in even low- to medium-resolution spectra, yielding results comparable to much more telescope-intensive high-resolution studies. We validate this method by comparison with 913 stars which have existing high-resolution and low- to medium-resolution to medium-resolution spectra, and that cover a wide range of stellar parameters. We find that at low metallicities ([Fe/H] {approx}<-2.0), we successfully recover both the metallicity and carbon abundance, where possible, with an accuracy of {approx}0.20 dex. At higher metallicities, due to issues of continuum placement in spectral normalization done prior to the running of autoMOOG, a general underestimate of the overall metallicity of a star is seen, although the carbon abundance is still successfully recovered. As a result, this method is only recommended for use on samples of stars of known sufficiently low metallicity. For these low-metallicity stars, however, autoMOOG performs much more consistently and quickly than similar, existing techniques, which should allow for analyses of large samples of metal-poor stars in the near future. Steps to improve and correct the continuum placement difficulties are being pursued.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of SXR/EUV radiation of exploded foils and wires with spectral, spatial and temporal resolution simultaneously on KING electric discharge facility.

The results of studies of the soft X-ray and extreme ultraviolet (SXR/EUV) radiation of thin flat aluminum foils and wires under the explosion in an electric discharge on the compact high-current KING generator are presented. These studies were based on the SXR/EUV spectroscopy with a spectral resolution of 6 Å, a temporal resolution of 5 ns and a spatial resolution of 200 μm. To study the plasma radiation of exploded foils and wires in the SXR/EUV range, we used a transmission diffraction grating spectrograph which in combination with two additional slits provided spectral and spatial resolution. The spectrograph was coupled with a 4-frame recorder based on a microchannel plate for providing temporal resolution. The analysis and comparison of the spectral, spatial, temporal, and energy characteristics of the SXR/EUV radiation of plasma formed under the explosion of foils and wires of a similar mass made of aluminum was carried out. Here, the spectra were calculated as well and the plasma parameters and their changes in time and space were estimated on the basis of these calculations and comparison with relevant experimental results. Experiments have shown that when foils explode, a single intense source of SXR/EUV radiation is formed with radiated energy in the range of 10-20 J and a power of up to 100 MW in the quantum energy range from 30 to 250 eV. At the same time, the radiation power under the explosion of foils turned out to be about twice above the power under the explosion of wires of comparable mass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive resolution simulation of salt solutions

We present an adaptive resolution simulation of aqueous salt (NaCl) solutions at ambient conditions using the adaptive resolution scheme. Our multiscale approach concurrently couples the atomistic and coarse-grained models of the aqueous NaCl, where water molecules and ions change their resolution while moving from one resolution domain to the other. We employ standard extended simple point charge (SPC/E) and simple point charge (SPC) water models in combination with AMBER and GROMOS force fields for ion interactions in the atomistic domain. Electrostatics in our model are described by the generalized reaction field method. The effective interactions for water–water and water–ion interactions in the coarse-grained model are derived using structure-based coarse-graining approach while the Coulomb interactions between ions are appropriately screened. To ensure an even distribution of water molecules and ions across the simulation box we employ thermodynamic forces. We demonstrate that the equilibrium structural, e.g. radial distribution functions and density distributions of all the species, and dynamical properties are correctly reproduced by our adaptive resolution method. Our multiscale approach, which is general and can be used for any classical non-polarizable force-field and/or types of ions, will significantly speed up biomolecular simulation involving aqueous salt.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-resolution mountain topography can inform global snow vulnerability estimates

Snow is changing globally. Computationally intensive snow reanalysis products and downscaled climate model projections allow for the estimation of historical and projected changes in snow over ∼4–10 km resolutions, but these resolutions are coarse relative to the scales needed for water supply and flood planning. Fine-scale digital elevation models (DEMs) are widely available but are underutilized to make first-order assessments of snow vulnerability. Here, we leverage DEMs at a 7.5 arc s (∼250 m) resolution, combining these with historical freezing level height estimates from ERA-5 to derive estimates of changes in the snow-receiving area (SRA) and its variability across global mountain ranges. Results show estimated SRA declines in 29% (1.9 million km2) of the global mountain area from 1982–2020; 66% of the mountainous areas had no change over the historical period. At +1.5 °C of warming relative to the pre-industrial control, global mountain SRA would decline by 9.5% (1.0 million km2) relative to recent conditions. This loss would be approximately doubled with +2 °C of warming. In a +4 °C warming scenario, an additional 34% (3.6 million km2) of SRA would be lost beyond the +2 °C case. Across individual mountain ranges, SRA losses can occur nonlinearly with warming, with some locations that have historically had relatively minor SRA losses at risk of substantially larger losses in warmer climates. Analysis using coarser-resolution DEMs can underestimate or overestimate SRA and its rate of loss, with the largest impacts in relatively warm, low-elevation mountain ranges. Results of this work provide estimates of projected loss in SRA at policy-relevant warming levels; inform the resolutions needed for process-based snow modeling; identify snow vulnerability hotspots; and provide a new integrated approach to snow vulnerability assessment that is achievable at global scales and highlights potential nonlinearities from recent trends to a variety of future warming scenarios.

climate, mountains↗

The Potential for Bayesian Compressive Sensing to Significantly Reduce Electron Dose in High Resolution STEM Images

The use of high resolution imaging methods in the scanning transmission electron microscope (STEM) is limited in many cases by the sensitivity of the sample to the beam and the onset of electron beam damage (for example in the study of organic systems, in tomography and during in-situ experiments). To demonstrate that alternative strategies for image acquisition can help alleviate this beam damage issue, here we apply compressive sensing via Bayesian dictionary learning to high resolution STEM images. These experiments successively reduce the number of pixels in the image (thereby reducing the overall dose while maintaining the high resolution information) and show promising results for reconstructing images from this reduced set of randomly collected measurements. We show that this approach is valid for both atomic resolution images and nanometer resolution studies, such as those that might be used in tomography datasets, by applying the method to images of strontium titanate and zeolites. As STEM images are acquired pixel by pixel while the beam is scanned over the surface of the sample, these post acquisition manipulations of the images can, in principle, be directly implemented as a low-dose acquisition method with no change in the electron optics or alignment of the microscope itself.

compressive sensing↗

Quantifying resolution in cosmological N- body simulations using self-similarity

ABSTRACT We demonstrate that testing for self-similarity in scale-free simulations provides an excellent tool to quantify the resolution at small scales of cosmological N-body simulations. Analysing two-point correlation functions measured in simulations using abacus , we show how observed deviations from self-similarity reveal the range of time and distance scales in which convergence is obtained. While the well-converged scales show accuracy below 1 per cent, our results show that, with a small force softening length, the spatial resolution is essentially determined by the mass resolution. At later times, the lower cut-off scale on convergence evolves in comoving units as a−1/2 (a being the scale factor), consistent with a hypothesis that it is set by two-body collisionality. A corollary of our results is that N-body simulations, particularly at high red-shift, contain a significant spatial range in which clustering appears converged with respect to the time-stepping and force softening but has not actually converged to the physical continuum result. The method developed can be applied to determine the resolution of any clustering statistic and extended to infer resolution limits for non-scale-free simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Avalanche statistics from data with low time resolution

Extracting avalanche distributions from experimental microplasticity data can be hampered by limited time resolution. We compute the effects of low time resolution on avalanche size distributions and give quantitative criteria for diagnosing and circumventing problems associated with low time resolution. We show that traditional analysis of data obtained at low acquisition rates can lead to avalanche size distributions with incorrect power-law exponents or no power-law scaling at all. Furthermore, we demonstrate that it can lead to apparent data collapses with incorrect power-law and cutoff exponents. We propose new methods to analyze low-resolution stress-time series that can recover the size distribution of the underlying avalanches even when the resolution is so low that naive analysis methods give incorrect results. We test these methods on both downsampled simulation data from a simple model and downsampled bulk metallic glass compression data and find that the methods recover the correct critical exponents.

97 MATHEMATICS AND COMPUTING↗

Deep Learning Super-Resolution X-Ray Computed Tomography Algorithms for Additive Manufacturing

Industrial X-ray computed tomography (XCT) is a nondestructive method for inspection and characterization of additively manufactured (AM) materials and parts. In practice, the resolution of XCT can be limited by factors such as detector binning, restricted field of view for large-scale objects, system blur, motion during scanning, and acquisition settings. These limitations can reduce the detectability of critical flaws such as pores, cracks, and lack of fusion. Super-resolution (SR) techniques offer a promising solution for improving the effective resolution and image quality of XCT reconstructions without the need for expensive hardware upgrades or laborious, time-consuming scans. In particular, deep learning-based SR methods have garnered attention in recent years as powerful tools for reconstructing high-resolution volumes from low-resolution inputs. In this work, a novel deep learning-based SR method is proposed for XCT scans of AM parts, and compared against several existing state-of-the-art (SOTA) methods. The proposed method, Simurgh-SR, is built on the pre-existing Simurgh framework and consists of a 2.5D U-Net trained to map low-quality inputs containing noise and artifacts to high-quality reconstructions characterized by higher flaw contrast, better noise texture, and reduced artifacts. The experimental results demonstrate superior performance of Simurgh-SR in performing 4× SR on real industrial XCT scans of thick 316L components, enhancing the structural similarity score and peak signal-to-noise ratio (>7dB) compared to the LR counterpart while improving the F1-score for flaw detection by more than 2.3× when compared to alternative SOTA SR methods. This improvement enables more accurate and significantly faster characterization of metal AM components. Additionally, Simurgh-SR was trained for both 2X and 4X SR and performs effectively at both levels, enabling the use of a single model for various SR factors.

Rahman, Obaid [ORNL] (ORCID:0000000277810840)↗

Next generation of extreme-resolution electron beam lithography

In top down nanofabrication research facilities around the world, the direct-write high-resolution patterning tool of choice is overwhelmingly electron beam lithography. Remarkably small features can be written in a variety of polymeric resists [V. R. Manfrinato et al., Nano Lett. 14, 4406 (2014); V. R. Manfrinato, A. Stein, L. Zhang, Y. Nam, K. G. Yager, E. A. Stach, and C. T. Black, Nano Lett. 17, 4562 (2017)]. However, this technology, which in this article the authors will refer to as conventional electron beam lithography (CEBL), is reaching its practical resolution and precision limits [V. R. Manfrinato et al., Nano Lett. 14, 4406 (2014)]. Hydrogen depassivation lithography (HDL) [J. N. Randall, J. W. Lyding, S. Schmucker, J. R. Von Ehr, J. Ballard, R. Saini, and Y. Ding, J. Vac. Sci. Technol. B 27, 2764 (2009); J. N. Randall, J. B. Ballard, J. W. Lyding, S. Schmucker, J. R. Von Ehr, R. Saini, H. Xu, and Y. Ding, Microelectron. Eng. 87, 955 (2010)] is a different version of electron beam lithography that is not limited in resolution and precision in the way that CEBL is. It uses a cold field emitter, a scanning tunneling microscope (STM) tip, to deliver a small spot of electrons on a Si (100) 2 × 1 H-passivated surface to expose a self-developing resist that is a monolayer of H adsorbed to the Si surface. Subnanometer features [S. Chen, H. Xu, K. E. J. Goh, L. Liu, and J. N. Randall, Nanotechnology 23, 275301 (2012)], and even the removal of single H atoms can be routinely accomplished [M. A. Walsh and M. C. Hersam, Annu. Rev. Phys. Chem. 60, 193 (2009)]. It is known that the H desorption process at low biases is a multielectron process [E. Foley, A. Kam, J. Lyding, and P. Avouris, Phys. Rev. Lett. 80, 1336 (1998)], but the tunneling distribution of the electrons from the STM tip to the Si surface lattice is not known. The authors have developed a simple model that demonstrates that the combination of two highly nonlinear processes creates a much higher contrast exposure mechanism than CEBL. Currently, HDL has been used almost exclusively on the Si (100) surface and has a limited number of pattern transfer techniques including Si and Ge patterned epitaxy, selective atomic layer deposition of TiO2 followed by reactive ion etching [J. B. Ballard, T. W. Sisson, J. H. G. Owen, W. R. Owen, E. Fuchs, J. Alexander, J. N. Randall, and J. R. Von Ehr, J. Vac. Sci. Technol. B 31, 06FC01 (2013)], and selective deposition of dopant atoms for quantum devices and materials [Workshop on 2D Quantum MetaMaterials held at NIST, Gaithersburg, MD, April 25–26, 2018, edited by J. Owen and W. P. Kirk]. While the throughput of HDL is very low, going parallel in a big way appears promising [J. N. Randall, J. H. G. Owen, J. Lake, R. Saini, E. Fuchs, M. Mahdavi, S. O. R. Moheimani, and B. C. Schaefer, J. Vac. Sci. Technol. B 36, 6 (2018)]. However, the most exciting aspect of HDL is its atomic-scale resolution and precision, which is key to nanoscale research. The authors see HDL emerging as the ultimate high-resolution patterning tool in top down nanofabrication research facilities.

42 ENGINEERING↗

NACHOS, a CubeSat-based high-resolution UV-Visible hyperspectral imager for remote sensing of trace gases: system overview and science objectives

Here, the Nano-satellite Atmospheric Chemistry Hyperspectral Observation System (NACHOS) is a high-throughput (f/2.9), high spectral resolution (~1.3 nm optical resolution, 0.6 nm sampling) Offner-design hyperspectral imager operating in the 300-500 nm spectral region. The 1.5U instrument payload (1U optical system, 0.5U electronics module) is hosted by a 1.5U LANL-designed CubeSat bus to comprise a 3U complete satellite. Spectroscopically similar to NASA’s Ozone Monitoring Instrument (OMI), which provides wide-field global mapping of ozone and other gases at coarse spatial resolution, NACHOS fills the complementary niche of targeted measurements at much higher spatial resolution. With 350 across-track spatial pixels and a 15-degree across-track field of view, NACHOS will provide spectral imaging at roughly 0.4 km per pixel from 500 km altitude. NACHOS incorporates highly streamlined gas-retrieval algorithms for rapid onboard processing, alleviating the need to routinely downlink massive hyperspectral data cubes. We will discuss the instrument design, challenges in achieving mechanical robustness to launch vibration in such a compact instrument, the onboard calibration system, and gas-retrieval data downlink strategy. We will also discuss potential science missions, including monitoring of NO 2 as an easily detected proxy for anthropogenic fossil-fuel greenhouse gases, monitoring lowlevel SO 2 degassing at pre-eruptive volcanoes, H 2 CO from wildfires, and characterization of aerosols. The long-term vision is for a many-satellite constellation that could provide both high spatial resolution and frequent revisits for selected targets of interest. As an initial technology demonstration of this vision, the NACHOS project is currently slated to launch two CubeSats in early 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-296: Dosimetric Analysis of Small Animal Image-Guided Irradiator Using High Resolution Optical CT Imaging of 3D Dosimeters

Purpose: To verify the dosimetric characteristics of a small animal image-guided irradiator using a high-resolution of optical CT imaging of 3D dosimeters. Methods: PRESAEGE 3D dosimeters were used to determine dosimetric characteristics of a small animal image-guided irradiator and compared with EBT2 films. Cylindrical PRESAGE dosimeters with 7cm height and 6cm diameter were placed along the central axis of the beam. The films were positioned between 6×6cm{sup 2} cubed plastic water phantoms perpendicular to the beam direction with multiple depths. PRESAGE dosimeters and EBT2 films were then irradiated with the irradiator beams at 220kVp and 13mA. Each of irradiated PRESAGE dosimeters named PA1, PA2, PB1, and PB2, was independently scanned using a high-resolution single laser beam optical CT scanner. The transverse images were reconstructed with a 0.1mm high-resolution pixel. A commercial Epson Expression 10000XL flatbed scanner was used for readout of irradiated EBT2 films at a 0.4mm pixel resolution. PDD curves and beam profiles were measured for the irradiated PRESAGE dosimeters and EBT2 films. Results: The PDD agreements between the irradiated PRESAGE dosimeter PA1, PA2, PB1, PB2 and the EB2 films were 1.7, 2.3, 1.9, and 1.9% for the multiple depths at 1, 5, 10, 15, 20, 30, 40 and 50mm, respectively. The FWHM measurements for each PRESAEGE dosimeter and film agreed with 0.5, 1.1, 0.4, and 1.7%, respectively, at 30mm depth. Both PDD and FWHM measurements for the PRESAGE dosimeters and the films agreed overall within 2%. The 20%–80% penumbral widths of each PRESAGE dosimeter and the film at a given depth were respectively found to be 0.97, 0.91, 0.79, 0.88, and 0.37mm. Conclusion: Dosimetric characteristics of a small animal image-guided irradiator have been demonstrated with the measurements of PRESAGE dosimeter and EB2 film. With the high resolution and accuracy obtained from this 3D dosimetry system, precise targeting small animal irradiation can be achieved.

60 APPLIED LIFE SCIENCES↗

Achieving sub-0.5-angstrom–resolution ptychography in an uncorrected electron microscope

Subangstrom resolution has long been limited to aberration-corrected electron microscopy, where it is a powerful tool for understanding the atomic structure and properties of matter. Here, we demonstrate electron ptychography in an uncorrected scanning transmission electron microscope (STEM) with deep subangstrom spatial resolution down to 0.44 angstroms, exceeding the conventional resolution of aberration-corrected tools and rivaling their highest ptychographic resolutions​. Our approach, which we demonstrate on twisted two-dimensional materials in a widely available commercial microscope, far surpasses prior ptychographic resolutions (1 to 5 angstroms) of uncorrected STEMs. We further show how geometric aberrations can create optimized, structured beams for dose-efficient electron ptychography. Our results demonstrate that expensive aberration correctors are no longer required for deep subangstrom resolution.

36 MATERIALS SCIENCE↗

2D Polyhedral Template Matching for Atomic Resolution Microscopy

SAND2024-13879O The 2D Polyhedral Template Matching for Atomic Resolution Microscopy is a suite of functions for analyzing atomic resolution electron microscopy images using the 2D polyhedral template matching (2D-PTM) method. This software analyzes atomic resolution microscopy data from electron microscopic imaging or scanning probe microscopies. The primary application is for identifying different crystal phases, crystal orientations, and defect structures obtained in such atomic resolution images. Written in MATLAB and starting from an atomic resolution image, the code identifies the positions of atomic intensity peaks. It then matches predefined structural templates to the local atomic environments. Outputs include the local structural identification, the template scaling factor and rotation angle, root-mean-squared deviation (RMSD), and centrosymmetry parameter.

Medlin, Douglas↗

Azimuthally averaged wind and thermodynamic structures of tropical cyclones in global climate models and their sensitivity to horizontal resolution

Characteristics of tropical cyclones (TCs) in global climate models (GCMs) are known to be influenced by details of the model configurations, including horizontal resolution and parameterization schemes. Understanding model-to-model differences in TC characteristics is a prerequisite for reducing uncertainty in future TC activity projections by GCMs. This study performs a process-level examination of TC structures in eight GCM simulations that span a range of horizontal resolutions from 1° to 0.25°. A recently developed set of process-oriented diagnostics is used to examine the azimuthally averaged wind and thermodynamic structures of the GCM-simulated TCs. Results indicate that the inner-core wind structures of simulated TCs are more strongly constrained by the horizontal resolutions of the models than are the thermodynamic structures of those TCs. As expected, the structures of TC circulations become more realistic with smaller horizontal grid spacing, such that the radii of maximum wind (RMW) become smaller, and the maximum vertical velocities occur off the center. However, the RMWs are still too large, especially at higher intensities, and there are rising motions occurring at the storm centers, inconsistently with observations. The distributions of precipitation, moisture, radiative and surface turbulent heat fluxes around TCs are diverse, even across models with similar horizontal resolutions. At the same horizontal resolution, models that produce greater rainfall in the inner-core regions tend to simulate stronger TCs. Further, when TCs are weak, the radial gradient of net column radiative flux convergence is comparable to that of surface turbulent heat fluxes, emphasizing the importance of cloud-radiative feedbacks during the early developmental phases of TCs.

54 ENVIRONMENTAL SCIENCES↗

Assessing Tropical Cyclones’ Contribution to Precipitation over the Eastern United States and Sensitivity to the Variable-Resolution Domain Extent

Tropical cyclones (TCs) can subject an area to heavy precipitation for many hours, or even days, worsening the risk of flooding, which creates dangerous conditions for residents of the U.S. East and Gulf Coasts. To study the representation of TC-related precipitation over the eastern United States in current-generation global climate models, a novel analysis methodology is developed to track TCs and extract their associated precipitation using an estimate of their dynamical outer size. This methodology is applied to three variable-resolution (VR) configurations of the Community Atmosphere Model, version 5 (CAM5), with high-resolution domains over the North Atlantic and one low-resolution conventional configuration, as well as to a combination of reanalysis and observational precipitation data. Metrics and diagnostics such as TC counts, intensities, outer storm sizes, and annual mean total and extreme precipitation are compared between the CAM5 simulations and reanalysis/observations. The high-resolution VR configurations outperform the global low-resolution configuration for all variables in the North Atlantic. Realistic TC intensities are produced by the VR configurations. The total North Atlantic TC counts are lower than observations but better than reanalysis.

54 ENVIRONMENTAL SCIENCES↗

Simulation of the Summer Monsoon Rainfall over East Asia using the NCEP GFS Cumulus Parameterization at Different Horizontal Resolutions

The most recent version of Simplified Arakawa-Schubert (SAS) cumulus scheme in National Center for Environmental Prediction (NCEP) Global Forecast System (GFS) (GFS SAS) has been implemented into the Weather and Research Forecasting (WRF) model with a modification of triggering condition and convective mass flux to become depending on model’s horizontal grid spacing. East Asian Summer Monsoon of 2006 from June to August is selected to evaluate the performance of the modified GFS SAS scheme. Simulated monsoon rainfall with the modified GFS SAS scheme shows better agreement with observation compared to the original GFS SAS scheme. The original GFS SAS scheme simulates the similar ratio of subgrid-scale precipitation, which is calculated from a cumulus scheme, against total precipitation regardless of model’s horizontal grid spacing. This is counter-intuitive because the portion of resolved clouds in a grid box should be increased as the model grid spacing decreases. This counter-intuitive behavior of the original GFS SAS scheme is alleviated by the modified GFS SAS scheme. Further, three different cumulus schemes (Grell and Freitas, Kain and Fritsch, and Betts-Miller-Janjic) are chosen to investigate the role of a horizontal resolution on simulated monsoon rainfall. The performance of high-resolution modeling is not always enhanced as the spatial resolution becomes higher. Even though improvement of probability density function of rain rate and long wave fluxes by the higher-resolution simulation is robust regardless of a choice of cumulus parameterization scheme, the overall skill score of surface rainfall is not monotonically increasing with spatial resolution.

CPS↗