Search NASA⌕ Search

SEARCH · Search NASA

Results for “wind integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Hybrid renewable energy systems: the value of storage as a function of PV-wind variability

As shares of variable renewable energy (VRE) on the electric grid increase, sources of grid flexibility will become increasingly important for maintaining the reliability and affordability of electricity supply. Lithium-ion battery energy storage has been identified as an important and cost-effective source of flexibility, both by itself and when coupled with VRE technologies like solar photovoltaics (PV) and wind. In this study, we explored the current and future value of utility-scale hybrid energy systems comprising PV, wind, and lithium-ion battery technologies (PV-wind-battery systems). Using a price-taker model with simulated hourly energy and capacity prices, we simulated the revenue-maximizing dispatch of a range of PV-wind-battery configurations across Texas, from the present through 2050. Holding PV capacity and point-of-interconnection capacity constant, we modeled configurations with varying wind-to-PV capacity ratios and battery-to-PV capacity ratios. We found that coupling PV, wind, and battery technologies allows for more effective utilization of interconnection capacity by increasing capacity factors to 60%–80%+ and capacity credits to close to 100%, depending on battery capacity. We also compared the energy and capacity values of PV-wind and PV-wind-battery systems to the corresponding stability coefficient metric, which describes the location-and configuration-specific complementarity of PV and wind resources. Our results show that the stability coefficient effectively predicts the configuration-location combinations in which a smaller battery component can provide comparable economic performance in a PV-wind-battery system (compared to a PV-battery system). These PV-wind-battery hybrids can help integrate more VRE by providing smoother, more predictable generation and greater flexibility.

14 SOLAR ENERGY↗

Laboratory demonstration of the prediction of wind-blown turbulence by adaptive optics at 8 kHz with use of LQG control

The low-latency adaptive optical mirror system (LLAMAS) is designed to push the limits on achievable latencies and frame rates. It has 21 subapertures across its pupil. Here, a reformulated version of the linear quadratic Gaussian (LQG) method predictive Fourier control is implemented in LLAMAS; for all modes, it takes just 30 µs to compute. In the testbed, a turbulator mixes hot and ambient air to produce wind-blown turbulence. Wind prediction clearly improves correction when compared to an integral controller. Closed-loop telemetry shows that wind-predictive LQG removes the characteristic “butterfly” and reduces temporal error power by up to a factor of three for mid-spatial frequency modes. Strehl changes seen in focal plane images are consistent with telemetry and the system error budget.

47 OTHER INSTRUMENTATION↗

The integration of remote sensing data into global weather prediction, wave forecasting, and ocean circulation computer based systems

Data from infrared imaging systems and satellite infrared spectrometer (SIRS) for determining sea surface temperature and the atmospheric structure in cloudless areas over the oceans are discussed. Although some interpretations differ, it is clear that simultaneous measurements of radar sea return and passive microwave temperature will provide estimates of the wind speed, and perhaps wind direction, over the oceans, especially in cloudless areas, for a wide range of wind speeds. The problem of integrating the data that would be obtained by a spacecraft, especially one with a combination radar-radiometer, into global analysis procedures for meteorological, wave, and oceanographic predictions is described.

Pierson, W. J., Jr.↗

Planar Transformer With Asymmetric Integrated Leakage Inductance Using Horizontal Air Gap

This article presents a novel planar-based transformer winding and core structure with controllable leakage inductance generation for integrated magnetics applications. As a result of limitations in integrated magnetics from the literature, a new approach is proposed utilizing semi-interleaved windings and controllable leakage via a leakage flux core leg featuring a horizontal air gap. Here, the proposed transformer design is analyzed via detailed reluctance modeling to determine closed-form equations for the magnetizing and asymmetrically distributed leakage inductances. Next, a genetic-algorithm-based multiobjective design optimization problem is developed, seeking to minimize the core and winding losses of the proposed transformer subject to a set of parametric and geometric constraints in a dc-ac dual-active-bridge topology for microinverter applications. The optimization was extended to include other integrated magnetic structures from the literature, where it is determined that the proposed transformer is superior from the perspectives of efficiency, footprint area, and parasitic capacitance. Based on the results of the optimization analysis, two designs with theoretical transformer California Energy Commission (CEC) efficiency drops (i.e., CEC efficiency reduction specifically due to the transformer loss mechanisms) of 1.19% and 0.83% were fabricated and evaluated for electrical and thermal performance in the proposed 40 V, 400 W microinverter.

42 ENGINEERING↗

Reliability‐based layout optimization in offshore wind energy systems

Abstract Existing methods for optimizing wind array layouts typically use power or cost objectives and rarely consider reliability‐based objectives. Component and system failure rates, however, are dependent on location‐specific wind conditions, are influenced by array layout and wake interactions, and have a direct and significant impact on capital costs, operational costs, and power production. Although wind power plant models exist that calculate wind loads with sufficient resolution to capture component loading dynamics from wind conditions, they are computationally expensive and thus not suitable for research applications requiring many evaluations, particularly optimization. This study describes the development of computationally efficient, reliability‐based layout optimization methods, enabling us to explore the relationship between component reliability and layout optimization. These methods include the surrogate modeling of the planet bearing life based on varying wind conditions simulated in FAST.Farm and the formulation of reliability‐based objectives based on failure cost and power production models. Through demonstration of this method, we explore how wind conditions, objective functions, and capacity density influence reliability‐based layout optimization. Results indicate that considering reliability alongside power production can reduce failure costs associated with replacement costs and downtime while maintaining or improving power production. Our conclusions highlight the opportunity for wind power plant developers to integrate reliability and operational expenditures alongside performance and capital expenditure objectives in plant design and development to improve plant performance and costs.

17 WIND ENERGY↗

Wind Turbine Contingency Control Through Generator De-Rating

Maximizing turbine up-time and reducing maintenance costs are key technology drivers for wind turbine operators. Components within wind turbines are subject to considerable stresses due to unpredictable environmental conditions resulting from rapidly changing local dynamics. In that context, systems health management has the aim to assess the state-of-health of components within a wind turbine, to estimate remaining life, and to aid in autonomous decision-making to minimize damage to the turbine. Advanced contingency control is one way to enable autonomous decision-making by providing the mechanism to enable safe and efficient turbine operation. The work reported herein explores the integration of condition monitoring of wind turbines with contingency control to balance the trade-offs between maintaining system health and energy capture. The contingency control involves de-rating the generator operating point to achieve reduced loads on the wind turbine. Results are demonstrated using a high fidelity simulator of a utility-scale wind turbine.

condition monitoring↗

Results of winglet development studies for DC-10 derivatives

The results of investigations into the application of winglets to the DC-10 aircraft are presented. The DC-10 winglet configuration was developed and its cruise performance determined in a previous investigation. This study included high speed and low speed wind tunnel tests to evaluate aerodynamic characteristics, and a subsonic flutter wind tunnel test with accompanying analysis and evaluation of results. Additionally, a configuration integration study employed the results of the wind tunnel studies to determine the overall impact of the installation of winglets on the DC-10 aircraft. Conclusions derived from the high speed and low speed tests indicate that the winglets had no significant effects on the DC-10 stability characteristics or high speed buffet. It was determined that winglets had a minimal effect on aircraft lift characteristics and improved the low speed aircraft drag under high lift conditions. The winglets affected the DC-10 flutter characteristics by reducing the flutter speed of the basic critical mode and introducing a new critical mode involving outer wing torsion and longitudinal bending. The overall impact of winglets was determined to be of sufficient benefit to merit flight evaluation.

Shollenberger, C. A.↗

The Langley Wind Tunnel Enterprise

After 4 years of existence, the Langley WTE is alive and growing. Significant improvements in the operation of wind tunnels have been demonstrated and substantial further improvements are expected when we are able to truly address and integrate all the processes affecting the wind tunnel testing cycle.

Paulson, John W., Jr.↗

Forecasting Wind and Solar Generation: Improving System Operations, Greening the Grid (Spanish Version)

This document is the Spanish version of 'Greening the Grid- Forecasting Wind and Solar Generation Improving System Operations'. It discusses improving system operations with forecasting with and solar generation. By integrating variable renewable energy (VRE) forecasts into system operations, power system operators can anticipate up- and down-ramps in VRE generation in order to cost-effectively balance load and generation in intra-day and day-ahead scheduling. This leads to reduced fuel costs, improved system reliability, and maximum use of renewable resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mexico Clean Energy Report

This report provides an assessment of Mexico's clean energy resource potential and pathways for rapidly deploying renewable energy technologies to enable Mexico to reach its goal of 35% renewable energy by 2024 within the current legal and regulatory framework. An appendix to the report includes the results of the 2024 Renewable Energy Integration Study, and technology chapters on wind, solar, geothermal, hydropower, transport electrification, and green hydrogen, detailing current state, resource potential, and deployment opportunities and recommendations. Additional sections include transmission, a section on the challenges and solutions for the integration of variable generation resources, and a summary of benefits.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Concept selection, optimization, and preliminary design of large wind generators

The development of the conceptual design of high (1000 kW, 18 mph mean wind speed site) and low (100 kW, 12 mph site) power wind generator systems to be integrated into a standard electric utility is discussed. Analyses leading to the selection of the rotor and tower design are outlined. The 1000 kW system selected for further development utilizes an all composite rotor blade design and a steel shell tower. The projected energy cost is 3.5 cents/kW hr. Results of optimization of the rated power, site wind speed, and rated wind speed parameters are summarized.

Meier, R. C.↗

Impact of Generator Flexibility on Electric System Costs and Integration of Renewable Energy

Flexibility of traditional generators plays an important role in accommodating the increased variability and uncertainty of wind and solar on the electric power system. Increased flexibility can be achieved with changes to operational practices or upgrades to existing generation. One challenge is in understanding the value of increasing flexibility, and how this value may change given higher levels of variable generation. This study uses a commercial production cost model to measure the impact of generator flexibility on the integration of wind and solar generators. We use a system that is based on two balancing areas in the Western United States with a range of wind and solar penetrations between 15% and 60%, where instantaneous penetration of wind and solar is limited to 80%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of dynamic testing of full-scale wind turbine drivetrains with hardware-in-the-loop

Dynamometer testing of full-scale wind turbine drivetrains involves subjecting integrated components to extreme static loads, fatigue loads, or dynamic loads to replicate field conditions. This paper provides a detailed evaluation of the uncertainty and errors in applied loads and measured responses, and their magnitude relative to established repeatability bounds for a drivetrain subjected to static and dynamic loads on the 7.5 MW test bench at the Clemson University Wind Turbine Drivetrain Testing Facility. An ideal drivetrain simulation model is utilized to isolate the influence of load tracking errors on test article responses. It is shown that the test article response variations are mainly driven by run out and clearances inherent to the drivetrain. For the dynamic profiles, the load tracking errors are within acceptable limits. Furthermore, a frequency analysis is used to show that the test bench controller tracking performance is acceptable for profiles with frequency content up to 1.5 Hz.

17 WIND ENERGY↗

Numerical study of 1-D, 3-vector component, thermally-conductive MHD solar wind

In the present study, transient, 1-dimensional, 3-vector component MHD equations are used to simulate steady and unsteady, thermally conductive MHD solar wind expansions between the solar surface and 1 AU (astronomical unit). A variant of SIMPLE numerical method was used to integrate the equations. Steady state solar wind properties exhibit qualitatively similar behavior with the known Weber-Davies Solutions. Generation of Alfven shock, in addition to the slow and fast MHD shocks, was attempted by the boundary perturbations at the solar surface. Property changes through the disturbance were positively correlated with the fast and slow MHD shocks. Alfven shock was, however, not present in the present simulations.

Han, S.↗

Reactor Subsystem Simulation for Nuclear Hybrid Energy Systems

Nuclear Hybrid Energy Systems (NHES) could be a key part of the solution to achieving energy security, may provide reliable power availability even with increasing renewable energy penetration into the power grid, and may allow repurposing excess electricity in times of low demand. Incorporating a fission-based power source in a multi-output system (electricity and process heat) can offer significant advantages over carbon-based production sources, such as coal or natural gas, including reduction in atmospheric carbon emissions. In an integrated multi-output system, thermal energy from the nuclear reactor subsystem can be diverted to industrial applications in times of low electricity demand. High temperature, high quality heat from advanced reactor designs might be used for hydrogen production or synthetic fuel production (coal-to-liquid or natural gas-to-liquid processes). Low temperature heat from advanced reactor designs or the current and future fleet of light water reactors (LWRs) might be applied to desalination processes or be stored for later use in low temperature ammonia or hydrocarbon-based thermal cycles. The NHES research team is currently developing a dynamic simulation of an integrated hybrid energy system. A detailed simulation of proposed NHES architectures will allow initial computational demonstration of a tightly coupled NHES to identify key reactor subsystem requirements, identify candidate reactor technologies for a hybrid system, and identify key challenges to operation of the coupled system. This work will provide a baseline for later coupling of design-specific reactor models through industry collaboration. The modeling capability addressed in this report focuses on the reactor subsystem simulation. Many computational tools and methods are available for modeling a nuclear reactor, power conversion systems and associated process applications. One method is to develop a single program capable of modeling the entire system. Another is to combine two or more existing computer programs, each modeling a portion of the system for which it is validated, where the programs exchange information to compute the solution. The former method requires a lengthy development and verification and validation process. The latter method leverages industry standard software to reduce development and funding requirements. Preliminary system models have been developed by Idaho National Laboratory researchers and are currently being enhanced to assess integrated system performance given multiple sources (e.g., nuclear + wind) and multiple applications (i.e., electricity + process heat). Initial efforts to integrate a Fortran-based simulation of a small modular reactor (SMR) with the balance of plant model have been completed in FY12. This initial effort takes advantage of an existing SMR model developed at North Carolina State University to provide initial integrated system simulation for a relatively low cost. The SMR subsystem simulation details are discussed in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Control and stabilization of the DOE/NASA Mod-1 two megawatt wind turbine generator

This paper describes the controls design, performance simulation process and specialized dynamic considerations for the DOE/NASA Mod 1 wind turbine generator (WTG). It shows controls, structural and utility interface considerations of the wind turbine generator and shows how a wind turbine generator can be integrated with a synchronous power system. Differences with respect to fossil or hydro generation and their implications are vital to long-term WTG reliability and availability and acceptance by utilities and consumers. The paper describes the control performance requirements to provide stable pitch and excitation control with drivetrain torsional dynamics, and the control of power swing stability and utility feeder voltage due to wind gusts.

Barton, R. S.↗

Aerodynamic Performance and Flow-Field Characteristics of Two Waverider-Derived Hypersonic Cruise Configurations

The component integration of a class of hypersonic high-lift configurations known as waveriders into hypersonic cruise vehicles was evaluated. A wind-tunnel model was developed which integrates realistic vehicle components with two waverider shapes, referred to as the straight-wing and cranked-wing shapes. Both shapes were conical-flow-derived waveriders for a design Mach number of 4.0. Experimental data and limited computational fluid dynamics (CFD) predictions were obtained over a Mach number range of 1.6 to 4.63 at a Reynolds number of 2.0 x 10(exp 6) per foot. The CFD predictions and flow visualization data confirmed the shock attachment characteristics of the baseline waverider shapes and illustrated the waverider flow-field properties. Experimental data showed that no significant performance degradations, in terms of maximum lift-to-drag ratios, occur at off-design Mach numbers for the waverider shapes and the integrated configurations. A comparison of the fully-integrated waverider vehicles to the baseline shapes showed that the performance was significantly degraded when all of the components were added to the waveriders, with the most significant degradation resulting from aftbody closure and the addition of control surfaces. Both fully-integrated configurations were longitudinally unstable over the Mach number range studied with the selected center of gravity location and for unpowered conditions. The cranked-wing configuration provided better lateral-directional stability characteristics than the straight-wing configuration.

Cockrell, Charles E., Jr.↗