Search NASASearch

SEARCH · Search NASA

Results for “Reduced-Order Models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,385 records · Page 47

General Purpose Data-Driven System Monitoring for Space Operations

Modern space propulsion and exploration system designs are becoming increasingly sophisticated and complex. Determining the health state of these systems using traditional methods is becoming more difficult as the number of sensors and component interactions grows. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. The Inductive Monitoring System (IMS) is a data-driven system health monitoring software tool that has been successfully applied to several aerospace applications. IMS uses a data mining technique called clustering to analyze archived system data and characterize normal interactions between parameters. This characterization, or model, of nominal operation is stored in a knowledge base that can be used for real-time system monitoring or for analysis of archived events. Ongoing and developing IMS space operations applications include International Space Station flight control, satellite vehicle system health management, launch vehicle ground operations, and fleet supportability. As a common thread of discussion this paper will employ the evolution of the IMS data-driven technique as related to several Integrated Systems Health Management (ISHM) elements. Thematically, the projects listed will be used as case studies. The maturation of IMS via projects where it has been deployed, or is currently being integrated to aid in fault detection will be described. The paper will also explain how IMS can be used to complement a suite of other ISHM tools, providing initial fault detection support for diagnosis and recovery.

Satellites

Ion Transport in Concentrated Crosslinked Solid Polymer Electrolytes

Crosslinking polymers is a common approach to create mechanically stable solid materials such as polymer electrolytes for lithium batteries. In conventional liquid electrolytes, the solvent molecules move freely to accommodate the field-induced motion of ions. However, in crosslinked polymer electrolytes, the rearrangement of polymer segments is constrained by the deformation limits of the network. Herein, we develop a new transport model that accounts for both the formation of concentration gradients and the elasticity of the electrolyte. The elasticity is incorporated by adding an additional term related to the entropy of crosslinked strands to the electrochemical potential of the salt. The resulting Crosslink Model contains two adjustable parameters: $\mathcal{N}$, the average number of monomers in a strand, and λ crit , the maximum strain the network can sustain. These solid-like constraints produce singularities in the governing transport equations, fundamentally altering the concentration profiles. Plateaus in salt concentrations emerge near the electrodes, and network elasticity introduces a strain overpotential. When compared to a Baseline Model ($\mathcal{N}$ → ∞, equivalent to concentrated solution theory), which predicts steepest gradients near the electrodes, both models yield similar current–voltage relationships. Model predictions are compared to electrochemical data for a poly(ethylene oxide)-based crosslinked polymer electrolyte.

Patel, Vivaan [University of California, Berkeley,

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Superdiffusion resilience in Heisenberg chains with two-dimensional interactions on a quantum processor

Superdiffusive spin transport in the one-dimensional (1D) Heisenberg model is a key theoretical discovery in nonequilibrium quantum many-body physics. Although extensively studied in 1D systems, the breakdown and sustenance of superdiffusion in two-dimensional (2D) lattices with integrability-breaking terms, as found in real materials, remains an open question. To address this, we develop a toy model that extends the 1D Heisenberg model with a representative set of 2D interaction types and tunable strengths. Our model exhibits varying degrees of superdiffusion breakdown depending on the interaction type, spanning ballistic to diffusive regimes. We establish and justify a hierarchy of 2D interactions based on their resilience against superdiffusion breakdown: Heisenberg >𝑋⁢𝑋 > Ising. This precise control over the superdiffusive behavior also enables rigorous benchmarking of quantum hardware, and our simulations on IBM's Heron devices confirm the hardware's ability to accurately capture these many-body nonequilibrium phenomena. Overall, our results are relevant not only to simulating superdiffusion in real materials, such as the 1D Heisenberg compound KCuF3, which contains modest nonintegrable 2D terms, but also to extending superdiffusive behavior to larger 2D qubit lattices and other 2D materials.

Alagarsamy Manikandan, Keerthi Kumaran [ORNL]

High-density Boron Nitride Nanotube Composites via Surfactant-stabilized Lyotropic Liquid Crystals for Enhanced Space Radiation Shielding

Despite significant technological advancements in space exploration, human space travel and colonization remain limited by the health risks associated with space radiation. Boron nitride nanotubes (BNNTs) have been proposed as an advanced material for space applications due to their high specific strength and efficient radiation shielding capabilities. However, the practical implementation of BNNTs has been slow, primarily due to technological challenges in fabricating structural materials incorporating BNNTs. In this study, a method is presented for fabricating high-density BNNT films that are mechanically robust, exhibit high thermal conductivity, and effectively attenuate space radiation. The key advancement enabling high-density BNNT films is the successful preparation of BNNT liquid crystals (LCs), achieved through the strategic use of a commercial dodecylbenzenesulfonic acid surfactant. This surfactant ensures exceptional BNNT stability in aqueous dispersion, even at concentrations exceeding the LC phase transition threshold. Simulations, estimating the equivalent radiation dose to the human body in space, indicate that a high-density BNNT film with a surface density of 50 g cm−2 reduces the total dose equivalent rate by 56% compared to zero shielding. This enhancement would allow astronauts to extend their mission duration on the lunar surface by a factor of two.

Young-Kyeong Kim

Accelerating actinium-225 purification by high-pressure ion chromatography

Actinium-225 (t1/2 = 9.92 days) is an important radioisotope for targeted alpha therapy applications. The limited supply obtained through the decay of thorium-229 has motivated accelerator-based production routes, including irradiation of thorium targets. Irradiated targets can produce useful quantities of actinium-225, but the product requires final purification from chemically similar lanthanide contaminants. This work describes an automated high-pressure ion chromatography method for this final polishing step. The method uses a reusable strong-acid cation-exchange column bearing sulfonic acid functional groups. α-Hydroxyisobutyric acid (α-HIBA), adjusted to pH 4.3 with lithium hydroxide, complexes and elutes lanthanides, a dilute hydrochloric acid matrix-exchange step removes residual α-HIBA, and concentrated hydrochloric acid then elutes retained actinium(III). The protocol purified actinium-225 to >99% radiopurity across tracer-level samples and samples containing >150 µCi (5.6 MBq) of activity. A 10 min, 0.1 M hydrochloric acid matrix exchange substantially reduced organic eluent carryover, and in-line sodium iodide detection enabled real-time monitoring of actinium and lanthanide elution. The developed method can be completed in <1 h and provides a basis for automated purification workflows for accelerator-produced actinium-225.

Gaddis, Kevin [ORNL] (ORCID:0000000183398314)

Stoichiometry dependent properties of cerium hydride: An active learning developed interatomic potential study

Cerium hydride has a variety of interesting properties, including a known lattice contraction and densification with increasing hydrogen content. However, precise stoichiometric control is not experimentally straightforward and ab initio approaches are not computationally feasible for many properties such as melting and low temperature diffusion. Therefore, we develop a machine-learned interatomic potential for cerium hydride that is valid for H to Ce ratios from 2.0 to 3.0. A query-by-committee active learning approach is used to develop the training set. Leveraging classical molecular dynamics simulations, we assess a range of properties and provide fundamental mechanisms for the trends with stoichiometry. Finally, a majority of the properties follow the trend of lattice contraction, being governed by the stronger lattice binding induced by adding octahedral atoms.

36 MATERIALS SCIENCE

Dark matter and baryon asymmetry from monopole-axion interactions

We introduce a novel mechanism where the kinetic energy of a rotating axion can be dissipated by the interactions with dark magnetic monopoles. This mechanism leads to a framework where the QCD axion and dark monopoles account for the dark matter density, and the observed baryon asymmetry is generated through the rotating QCD axion via axiogenesis. The monopoles acquire masses from a nonzero axion field, and they can transition between different quantized dyonic levels in the presence of a rotating axion field. The axion kinetic energy is dissipated by the transition, and thus the axion abundance is depleted to the observed dark matter abundance. We predict that the axion decay constant should be below 10 9 GeV to explain the observed dark matter and baryon densities.

Axions and ALPs

Development and Validation of a High-Vacuum Thermal Conductivity Testbed for Aerospace Interface Materials

Spacecraft thermal margins depend on the temperature penalty of installed interfaces, yet catalog conductivity omits bondline thickness, mating surfaces, preload, and environment. The Testbed for Advanced Interface Materials in Vacuum (TAIMV) addresses this engineering-data gap by converting ambient/vacuum temperature fields from a four-coupon stack into quantities usable in spacecraft thermal models. Its 17-node steady-state model resolves axial conduction, parasitic fixture paths, grease-filled contact, radiation, and ambient convection. Four monolithic checks gave axial heat-rate ratios of 0.90–1.02, and Braycote calibration self-recovery gave 2.20% casewise mean absolute percentage error (MAPE) and 2.85% maximum difference. With transferable fixture terms frozen, Krytox LVP tested cross-material transfer against a manufacturer-derived external relation. The six Krytox cases gave 2.28% MAPE, 5.10% maximum difference, and full-field residual root-mean-square values of 0.553 °C ambient and 1.306 °C vacuum. Installed-joint resistance spanned 6.39–7.15 × 10⁻⁴ m²·K/W for Braycote and 4.09–4.49 × 10⁻⁴ m²·K/W for Krytox, corresponding to 2.33–6.66 K per modeled interface over the tested heat-flux range. TAIMV therefore supplies directly usable installed-joint resistance and conductance, plus apparent installed conductivity and explicitly model-conditioned grease conductivity/contact terms.

heat transfer

From zonal to nodal capacity expansion planning: Spatial aggregation impacts on a realistic test-case

Solving power system capacity expansion planning (CEP) problems at realistic spatial resolutions is computationally challenging. Thus, a common practice is to solve CEP over zonal models with low spatial resolution rather than over full-scale nodal power networks. Due to improvements in solving large-scale stochastic mixed integer programs, these computational limitations are becoming less relevant, and the assumption that zonal models are realistic and useful approximations of nodal CEP is worth revisiting. Here, this work is the first to conduct a systematic computational study on the assumption that spatial aggregation can reasonably be used for ISO-scale CEP. By considering a realistic, large-scale test network based on the state of California with over 8000 buses, we find that well-designed small spatial aggregations can yield good approximations but that coarser zonal models may result in large distortions of investment decisions, e.g., capacity under-investment of up to 41% for the lowest resolution model considered.

24 POWER TRANSMISSION AND DISTRIBUTION

Li-ion Battery Aging with Hybrid Physics-Informed Neural Networks and Fleet-wide Data

In this work, we propose a hybrid model for Li-ion battery discharge and aging prediction that leverages fleet-wide data to predict future capacity drops.The model is built upon an hybrid approach merging physics-based and empirical equations, as well as neural network models in a recurrent neural network cell. The hybrid physics-informed neural network can predict voltage discharge cycles given the loading profile, and estimate the used capacity of the battery under random-loading conditions by tracking aging parameters connected to the residual capacity of the battery. By merging information on the battery aging parameters with existing fleet-wide aging data, the model can predict the future residual capacity of the battery that is being monitored, and therefore enable predictions of voltage discharge curves far ahead in the battery life cycle. We validated the approach using the NASA Prognostics Data Repository Battery data-set, which contains experimental data on Li-ion batteries discharged at random loading conditions in a controlled environment. The approach also allows the identification of discrepancies between the battery aging trend and the trend observed at the fleet level, so that batteries behaving differently from the rest of the fleet can be subject to closer monitoring and further testing to refine predictions.

PINN

Lepto-axiogenesis with light right-handed neutrinos

We study lepto-axiogenesis in theories where the right-handed neutrino is light enough that its dynamics affect the determination of the baryon asymmetry. When compared with theories of high-scale lepto-axiogenesis where the Majorana neutrino mass may be treated as an effective dimension-five operator, we find that the predicted saxion mass is lower. Two distinct scenarios emerge. In the first, processes that generate the baryon asymmetry are in equilibrium down to the mass of the right-handed neutrino. In the second, the relevant processes never reach equilibrium; the baryon number freezes in. We comment on implications for supersymmetric spectra and discuss constraints on late decays of supersymmetric relics and from dark radiation. In contrast to high-scale lepto-axiogenesis, which predicts superpartners with masses of 10–100 TeV or more, we find this scenario is consistent with a wider range of superpartner masses, all the way down to current direct search bounds.

Axions and ALPs

Project Development of an Electrochemical Denitration and Caustic Generation System for HLW Pretreatment at Hanford - 26350

An engineering-scale electrochemical processing skid is proposed to perform the denitration of Hanford tank waste, which would help to mitigate a key process concern with the direct feed processing of the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The reduction of nitrates and organic compounds in the waste feed will directly reduce hazardous NOx and ammonia gases generated during the vitrification process, which in turn will aid in addressing potential regulatory and safety challenges associated with processing large volumes of tank waste. This paper highlights the past legacy work, project layout, accomplishments from Phase 1 and research and development envisioned for Phase 2. An innovative electrochemical denitration and caustic generation (EDCGe) process was demonstrated for the pretreatment of tank waste at the Savannah River Site (SRS) in the early 2000s. The denitration electrolyzer, off-gas abatement system, and caustic generator electrolyzer are being developed with the intent that the denitration electrolyzer will convert nitrate and nitrite anions to nitrogen gas while also yielding other gaseous byproducts, which may include N2O, NH3, VOCs, and H2. The gaseous byproducts will be managed via a tandem off-gas catalyst-bed treatment system. The caustic generation electrolyzer will recycle NaOH from the feed to produce a clean caustic stream for use within the batching tanks at Hanford, aiding in the preparation of waste for WTP. The reduction in hazardous emissions and improved waste treatment processes provides a robust solution for nuclear waste management, contributing to environmental safety and regulatory compliance. The EDCGe technology is being adapted, modified, and updated for the preparation of the Direct Feed-High Level Waste (DF-HLW) flowsheet at Hanford. Phase 1 demonstrated a bench-scale proof-of-concept for reactions involving the denitration electrolyzer and gas phase abatement of ammonia. The electrochemical technology is drawing on the scientific outcomes that were reported in the legacy work. The results from Phase 1 demonstrated the viability of the EDCGe system in reducing the nitrogen species of simple non-radioactive waste simulants. Commercially available alloys used as electrode materials and membranes are being studied for the denitration and caustic generation electrolyzers. The continuation of this project holds promise for broader applications, such as energy-efficient ammonia production, and contributes significant advancements in nuclear waste management. Additional material discovery has been investigated into ceramic Na super ion conductive (NaSICON) materials and off-gas abatement catalyst discovery. NaSICON is of interest for selective transport of Na within the electrolyzers to make a clean caustic stream. Future integration and optimization efforts, informed by Phase 1 results and ongoing research, will continue to drive advancements in nuclear waste management technology. The technology developed for the EDCGe treatment of tank waste will also have broader potential to inform other fields, such as energy-efficient ammonia production, as well as ammonia abatement catalysis through the lessons learned in electrochemical nitrate reduction. The applications and benefits of this research extend beyond Hanford and the Savannah River Site, supported by a collaborative team of scientists and engineers from national labs, academia, and industry, ensuring a comprehensive approach to solving complex waste treatment challenges. The team is leveraging advanced electrochemical technologies, machine learning, novel catalysts tailored for gaseous nitrogen species, and cutting-edge reactor systems to enhance the process efficiency and effectiveness of the denitration process.

Rodene, Dylan [Savannah River National Laboratory

Polarized target nuclear magnetic resonance measurements with deep neural networks

Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.

Metrology

Evaluation of Fatigue Damage Accumulation Functions for Delamination Initiation and Propagation

The present report follows on the cohesive fatigue damage model methodology proposed in NASA-TP-2018-219838. In that report, an empirical function describing the incremental damage due to cyclic loading was used to calculate fatigue damage within a cohesive formulation. The form of the function was developed such that, when integrated at a constant stress amplitude from no damage to failure, it produces a life versus load response that is consistent with an S-N diagram. Therefore, the parameters of the damage model could be obtained by fitting the model predictions to an S-N diagram. The finite element analyses performed demonstrate that the cohesive fatigue accumulation function provides a link between the S-N diagram that describes crack initiation, and the Paris law that characterizes the rate of crack propagation. However, when the model was proposed, it was not known whether the form of the damage accumulation function associated with a desired S-N diagram is unique and, if not, if the link between S-N and the Paris law is unique and independent of the fatigue function selected. In the effort described herein, several alternative forms of the damage function that reproduce the desired features of S-N diagrams were found and evaluated. The effects of each of these functions on the predicted parameters of the Paris law and the propagation threshold are discussed. The results indicate that the predicted exponent m of the Paris law is indeed independent of the damage accumulation function. However, different functions predict different values for the pre-factor C of the Paris law. Therefore, the proper damage accumulation function must be selected by comparison with experiments. One of the new damage accumulation functions proposed herein was found to be particularly useful for analysis because of the ease with which the model parameters can be determined with a minimal amount of experimental information. The effectiveness of the proposed methodology and damage function was demonstrated by conducting analyses of a double cantilever beam test, a mixed-mode bending test, and a three-point bending test of a skin/doubler specimen. The results indicate that the same set of model parameters can provide accurate predictions of the rate of fatigue crack propagation for a variety of material interfaces, mode mixities, load levels, and stress ratios.

DKIN/Stiffener Debonding

Fuels and Combustion Technology for Advanced Aircraft Engines [Les Propergols et les Systèmes de Combustion pour les Moteurs d'Aéronefs]

The Conference Proceedings contains the 38 papers presented at the Propulsion and Energetics Panel 81st Symposium on "Fuels and Combustion Technology for Advanced Aircraft Engines" which was held from 10th-14th May 1993, in Fiuggi, Italy. The Technical Evaluation Report and the Keynote Address are included at the beginning, and discussions follow most papers. The Symposium was arranged in the following Sessions: Technology Overview Papers (2); Modelling: Pollutant Formation (4); Modelling: Combustor Design (5); High Temperature Fuels and Fuel Systems (6); Combustion Research: Performance (6); Combustion Research: Emissions (5); Fuel Atomization: Diagnostics and Modelling (5); and Combustion Research: Flowfleld and Mixing (4). The last paper is a contribution from Russia not allocated to a session. New technologies for low NOx combustors and advanced high-pressure/high temperature cycle engines result in unique problems in design and performance. There have been significant advances in modelling and diagnostics to aid the development of these technologies. The purpose of the Symposium was to bring together experts from industry, research establishments and universities to discuss fundamental and applied research in these areas as relevant to the development of advanced gas turbine engines, to exchange practical experience and to discuss the state of the art.

Fuels for aircraft

Summary of Research Report

Ten papers, published in various publications, on buckling, and the effects of imperfections on various structures are presented. These papers are: (1) Buckling mode localization in elastic plates due to misplacement in the stiffner location; (2) On vibrational imperfection sensitivity on Augusti's model structure in the vicinity of a non-linear static state; (3) Imperfection sensitivity due to elastic moduli in the Roorda Koiter frame; (4) Buckling mode localization in a multi-span periodic structure with a disorder in a single span; (5) Prediction of natural frequency and buckling load variability due to uncertainty in material properties by convex modeling; (6) Derivation of multi-dimensional ellipsoidal convex model for experimental data; (7) Passive control of buckling deformation via Anderson localization phenomenon; (8)Effect of the thickness and initial im perfection on buckling on composite cylindrical shells: asymptotic analysis and numerical results by BOSOR4 and PANDA2; (9) Worst case estimation of homology design by convex analysis; (10) Buckling of structures with uncertain imperfections - Personal perspective.

Isaac Elishakoff

Nanoscale Compositional and Strain Gradients Enable High‐Speed and Amplitude‐Resolved Pyroelectric Sensing

The frequency response of pyroelectric sensors is fundamentally governed by thermal time constant (τth, determined by thermal mass and thermal conductance) and electrical impedance arising from film capacitance and readout circuit. Conventional bulk LiTaO3 detectors are optimized for high responsivity at low modulation frequencies (0.1-10 Hz), possessing a large τth that thermally averages rapid temperature oscillations at elevated modulation frequencies, limiting fidelity in resolving dynamic varying thermal signals. Here, compositional and strain gradients are introduced into 100-nm-thick relaxor-ferroelectric films reducing τth to ≈2 µs and producing built-in potentials (≈1.45 V or 145 kV cm-1) that enhance the pyroelectric coefficient and suppress the dielectric constant. This enables complementary dual-mode operation by enhancing current-mode electrical responsivity and improving the voltage-mode figure of merit - advantageous for superior temperature resolution (ΔTmin ≈ 30 µK). The responsivity peak shifts to near 1 kHz (>2500-times higher than conventional bulk sensors), with measurable responsivity extending to a carrier frequency of 100 kHz and amplitude-resolved detection at modulation frequencies up to 15 kHz. These results establish nanoscale internal-field engineering can reshape electro-thermal trade-off in pyroelectric thin films toward zero-bias, high-thermal-sensitivity, and amplitude-resolved thermal sensing across a wide frequency bandwidth.

Lin, Ching‐Che